A Detailed Introduction to the Basic Operation of SerialEM.

Slides:



Advertisements
Similar presentations
Creating posters and flyers Lesson -IV. Editing pictures inside Office Office 2007 has tools to edit photos and pictures in the document. Office 2007.
Advertisements

Ease of Access and Assistive Technology on Windows 7 Computer Access for Individuals with Visual Impairments.
Working with Profiles in IX1D v 3 – A Tutorial © 2006 Interpex Limited All rights reserved Version 1.0.
Microsoft® Access® 2010 Training
Using Macros, Camera Issues, and Setting Up SerialEM
Getting started with LEGO NXT Mindstorms software This is intended to be a short introduction to the LEGO Mindstorms software and programming the LEGO.
Introduction to Operation of the XL-30 Scanning Electron Microscope Tutorial # 1 Overview of XL-30 Microscope Control Program.
How to import and edit video clips in Windows Movie Maker
Computer Basics Hit List of Items to Talk About ● What and when to use left, right, middle, double and triple click? What and when to use left, right,
Operating the Harmonizer
 Use the Left and Right arrow keys or the Page Up and Page Down keys to move between the pages. You can also click on the pages to move forward.  To.
Set the Camera Options  Resolution  Focus  Exposure  Zoom  Flash  Self-Timer/Remote Control.
By Aaron Proia and Matthew Copenhaver.  For this presentation, we will be walking you through two processes that are commonly used in Photoshop.  These.
Exposure The balance of the amount of light allowed entering the photographic medium There are 3 elements used to create the desired exposure 1. ISO 2.
Windows XP Basics OVERVIEW Next.
CIS-100 Chapter 3—The Ribbon. The Ribbon When you first open Word 2007, you may be surprised by its new look. Most of the changes are in the Ribbon, the.
 Any time you half press the shutter button, the light meter activates.  As we know, it measures the light in your scene, and calculates a shutter speed.
XP New Perspectives on Microsoft Office Word 2003 Tutorial 1 1 Microsoft Office Word 2003 Tutorial 1 – Creating a Document.
XP 1 Microsoft Office Word 2003 Tutorial 1 – Creating a Document.
Low Dose Mode, Navigator, and Energy Filtering in SerialEM.
Using the Unity 98 Cordless Response System Directions : Courtesy of IHC public relations.
ABC’s of PowerPoint (Office 2007) Part 1: Basic Vocabulary Part 2: Cursors Part 3: Insert Your Text Part 4: Insert Your Pictures Part 5: Basic Tools &
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Microsoft ® Office PowerPoint ® 2003 Training Playing movies [Your company name] presents:
Operation of the S4700 FESEM
OVER EXPOSED UNDER EXPOSED? OVER AND UNDEREXPOSED: DEFINED The exposure related decision made can affect your image in a number of different ways. For.
Camera Functions Using Your Digital Camera. 1. What happens when you press the shutter button down halfway? What does macro mode allow you to do? Pressing.
Advanced Tables Lesson 9. Objectives Creating a Custom Table When a table template doesn’t suit your needs, you can create a custom table in Design view.
Working with GPS Stephen M. Kiama (MSc) [Geo-information Specialist]
Microsoft Office Word 2003 Tutorial 1 Creating a Document.
Spreadsheets in Finance and Forecasting Presentation 8: Problem Solving.
STEP 1: Determining the exact image width STEP 1: Determining the exact image width Position of X-ray Filter Position of X-ray Filter STEP 5: Crop Extra.
Shooting. Initial Camera Settings Cameras have default settings for picture quality. The school’s cameras are no exception. Camera resets to default settings.
1 CA201 Word Application Increasing Efficiency Week # 13 By Tariq Ibn Aziz Dammam Community college.
Get up to speed with the 2007 Office system The new Office: Made for you Yes, there’s a lot of change to familiar Microsoft Office programs. But it’s good.
Microsoft PowerPoint Getting Started Guide Prepared for Towson University Dr. Jeff M. Kenton Amy Chase Martin 2007.
MICROSOFT WORD GETTING STARTED WITH WORD. CONTENTS 1.STARTING THE PROGRAMSTARTING THE PROGRAM 2.BASIC TEXT EDITINGBASIC TEXT EDITING 3.SAVING A DOCUMENTSAVING.
Color Correct and Remove Keystoning A minimalist approach to photographing your art By Paul Marley.
CAD3D Project. SketchUp - Project Create a new SketchUp project called InitialsXX where the XX are your first and last initial. Use the Rectangle tool.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
XP 1 Microsoft Word 2002 Tutorial 1 – Creating a Document.
Thursday, 15 October 2015 PowerPoint Tips 3 Click your level above smart smarter smartest Press escape on the keyboard to close this presentation. This.
Windows Tutorial Common Objects ACOS: 1, 4. Using the Taskbar 1. Using the taskbar, you can switch between open programs and between open documents within.
Getting Started With AutoCAD ENGR 2 Week #1 Laboratory.
XP 1 Microsoft Access 2003 Introduction To Microsoft Access 2003.
Addison Wesley is an imprint of © 2010 Pearson Addison-Wesley. All rights reserved. Chapter 7 The Game Loop and Animation Starting Out with Games & Graphics.
Calibration & Measurements. Calibrating the System Before we can make any measurements we need to calibrate our imaging system to create real world numbers.
CREATING TEMPLATES CREATING CUSTOM CHARACTERS IMPORTING BATCH DATA SAVING DATA & TEMPLATES CREATING SERIES DATA PRINTING THE DATA.
Microscope Control Configuration This section of the QED manual will describe how to configure you Configure and Control your automated microscope. Mac.
Game Maker Terminology
PLACING AND LINKING GRAPHICS
Take a series of photos in manual mode to demonstrate an understanding of exposure and depth of field.
A skills approach © 2012 The McGraw-Hill Companies, Inc. All rights reserved. powerpoint 2010 Chapter 4 Managing and Delivering Presentations.
Camera Basics Intro to TV Production. It’s like riding a bike… You can learn to operate a camera only by doing it.
Machine Vision Introduction to Using Cognex DVT Intellect.
IT1001 – Personal Computer Hardware & system Operations Week7- Introduction to backup & restore tools Introduction to user account with access rights.
Russell Taylor. Digital Cameras Digital photography has many advantages over traditional film photography. Digital photos are convenient, allow you to.
The desktop (overview) Working with desktop icons The desktop is the main screen area that you see after you turn on your computer and log on to Windows.
Intelligent Robotics Today: Vision & Time & Space Complexity.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
Train Body The next series of slides will guide you through the construction of the train body. Start a new drawing and save it as Train Body.
Hi, I’m Michele Del Core! I’m 18 years old and photography is one of my biggest passions. Practicing and doing researches about it, I discovered that.
1 Setting Laser Power and PMT Gain Begin with laser power at 20% Set PMT gain to 6.00.
Premiere Editing, Continued
Camera Basics.
HADI Tutorial Templates
An Introduction to the Enlarger and Project 1
Aperture, Exposure and Depth of Field
Presentation transcript:

A Detailed Introduction to the Basic Operation of SerialEM

Image Buffers in SerialEM Images are saved in buffers, referred to as A – N Camera acquisitions and processed images go into buffer A, and the top few images are rolled into higher buffers Typical situations (enforced during tilt series) are: ABCDE…GH…ABCDE…GH… New image -> Align reference Read-in image -> (Home) (Insert) (Delete) (End) Normal operation New image -> Record reference Read-in image -> (Home) (Insert) (Delete) (End) Low dose mode ABCDEFGH…ABCDEFGH… Trial reference

Image Display Panel The available data range in the displayed image is controlled by the Black and White levels: everything outside this range is truncated To determine Black and White, it analyzes pixels in a central area and truncates a certain fraction Contrast and brightness are of limited usefulness because of this truncation Most useful option is to set “Area Fraction” to smaller value, like spot metering on smaller central area To see contrast at extreme end of range, enter image minimum as Black value or image maximum as White value Zoom pretty much takes care of itself with default settings

Microscope Status Panel Screen current is more useful than exposure time; “Float” button floats a screen meter, good when tuning scope “Dose” button floats a cumulative dose meter The Defocus is based on a microscope readout, not the actual focus on the specimen –On Tecnai, it matches TUI defocus reading, can be reset in TUI or SerialEM –On JEOL, it is arbitrary and set to zero on program startup, can be reset IS is image shift in microns, important to know on 300KV Tecnai and JEOL 2100 without high power image shift

Tilt Control Panel The delay time is the delay after tilting by basic increment – delay will be longer or shorter for bigger or smaller tilts Camera and Macro Tools Buttons for camera parameter setup and 5 camera acquisition modes (good for low dose) STOP is the one general stop button for all kinds of operations “Preview” morphs into “Montage” when montaging, unless low dose is on Macro buttons also morph into useful buttons during tilt series

Camera Parameter Setup Continuous acquisition is only mildly useful (no access to fast camera modes) Processing options useful for testing and troubleshooting; otherwise always use gain normalization Binning is used for speed. Tracking correlations are always binned down to 512 so there is no point taking Trials bigger than 512. A full-width image gives fastest readout per pixel; hence the wide options for fast subarea pictures A separate dark reference is kept for every binning and exposure time. –“Force new dark reference next time” is the way to remove a dark reference –Averaging dark references is helpful for a high-noise camera (not typical)

Pre-exposure Pre-exposure (drift settling) requires two shutters The Gatan shuttering mode that allows pre-exposure is inflexible and exposes specimen during readout – so SerialEM uses beam blanking to provide selected pre-exposure while blanking during readout –“Dual shuttering – minimum exposure” mode provides for this and just does beam blanking when drift settling is 0 – so it can always be used –But the camera timing must be calibrated so the beam blanking does not occur during exposure time Tietz cameras require Shutterbox II for pre-exposure to work

Image Alignment & Focus Autoalign always changes microscope image shift – “Clear alignment” undoes that “Reset Image Shift” moves the stage to keep the same specimen point centered Moving stage for mouse shifts avoids having to reset image shift –Happens automatically if option selected and movement is above either absolute (micron) or relative (fraction of field) threshold –You can do it intentionally with Shift key Trimming dark borders keeps autoalign from being thrown off by beam edge or grid bar –Used automatically in low dose and during “tasks” done at lower than working mag –Will not detect less extreme contrast differences that can throw off autoalign – alternative is to use smaller area (higher trim fraction) “Center image shift on tilt axis” will give fewer movements during tilt series but requires an offset calibration

Autofocusing with Beam Tilt Autofocus is done by taking two images with the beam tilted in opposite directions and measuring the shift between images It relies on the microscope being aligned such that the image of a specimen in the focal plane of the objective lens does not move when the beam is tilted. A Specimen in focal plane Image plane A appears here with both directions of tilt B Specimen out of focus Image plane B or C appears here depending on direction of tilt C

Focus Parameters and Operations The target is the defocus it sets to after measuring The beam tilt needs to be big enough to get good image displacements, but is limited by objective aperture Autofocus Offset lets you measure defocus at focus different from target –Can protect against correlation failures by focusing at zero –Can be used to focus at a defocus with more contrast Taking three pictures lets it subtract off drift – “Drift protection” –“Report shift and drift” takes the three pictures and just tells you the beam-induced shift and the drift –“Report on existing” reports the shift and drift from pictures just acquired “Autofocus” measures and changes to target; “Measure defocus” just measures without changing Autofocus sometimes works poorly at high tilt - “Check autofocus” assesses what fraction of a known focus change can be detected “Move Focus Center” lets you click on spot at desired focus and change focus so center of field is at that focus

File Operations You can open new image files or existing files (up to 8 now) Opening a new file brings up File Properties dialog, where you set the data type and items to save in header Anything selected for saving can be extracted with extracttilts (options -st, -ma, or -in for stage position, mag, or intensity) After opening an old file, the “Set” options can be used to change the properties that would be set in the File Properties dialog “Save to Other” and “Read from Other” can be used to save one image or read from a file without leaving it open You can save an image to a specific Z value with “Overwrite” Saving a log is useful. “Read & Append” lets you accumulate a log across several runs of the program

Camera Commands The most commonly used item in the camera menu is “Prepare Gain Reference” –Gain reference can be done at typical exposure for non-low dose work –Having lots of counts averaged (e.g., ~10 x 1/3 of dynamic range) is more important than matching the counts for actual images –Binned gain reference works for normalizing images with even binning – useful for slow 4K camera that is being used as 2K camera –If camera counts per electron is calibrated, this can do automatic dose calibration It can be useful for troubleshooting to view gain reference or dark reference of image just taken “Post-actions” controls whether image shift, mag change, or stage move are taken during camera readout –Requires correct camera timing parameters and with that, it is surprisingly robust –But it can be turned off to troubleshoot problems

Montaging – The Camera Is No Limit To start montaging, define the number of frames in X and Y in Montage Setup dialog –Parameters start at current state, based on current Record parameters –The default overlap (10%) is fine for image-shift based montage –Once data has been taken, or if you open an existing montage, most parameters in the dialog are locked After taking a montage, you will see “overview” in buffer B, a subsampled version of the whole area A (composed) image of the center is left in A for alignment Either image can be mouse-shifted “Prescan” takes a fast highly binned montage of the same area without storing it Options are mostly important when using montages as navigation maps, except: –“Change focus with height” will take each picture at same focus, but this may make it harder to correct for distortions due to magnification gradients

Image Processing In general, processing works on the active image, the processed image is put in A, and the top images are rolled Binned FFT bins the image to 512 pixels –It is faster, less noisy but only shows central part of frequency space –Probably most useful for assessing drift in image Live FFT will do FFT immediately in Continuous acquisition mode (version 2.6.4?) X-ray items are to help set up removal of X-rays in dark references and images –X-ray removal from images should only be done for low-dose images from low gain cameras where X-rays screw up tracking “Show cross-corr” will do an autoalignment with current A and align buffer images, then show correlation

Tasks Tasks are (mostly) operations required for doing tilt series, involving a sequence of stage movements and tracking images Eucentricity has two different routines –Rough eucentricity will work from 100 µm away or more in Z –Refine eucentricity does a ±24 tilt series to measure Z height with lateral offset of tilt axis taken into account and estimated also Works up to 10 µm away or more “Refine & Realign” runs it in a way that restores the image position at the end Can use result to “Set Tilt Axis Offset” Tilt axis Optic axis Specimen feature +24° -24° 0° Axis offset ΔZΔZ

Tasks #2 Walk Up goes from one tilt to another while keeping an image feature centered –“Anchor” is an image at intermediate tilt that can be a reference when coming back down in a tilt series “Reset IS & Realign” and “Reverse Tilt” keep an image feature centered when resetting image shift or reversing direction of tilt “Set Intensity” lets you change intensity based on the counts in the current image –Enter a factor to change intensity by (e.g., 0.75, 1.5) –Or enter desired counts in a Record image (e.g., 4000) “Move Beam” - if you click at the center of the beam, this will move the beam to the center of the field +

The Problem of Tilt Series Acquisition The goal in acquiring a tilt series is to have every picture centered on the same specimen feature, and at the same focus The basic sequence of operations required is thus: - Tilt to a new tilt angle - Correct change in specimen position - Correct change in specimen focus - Acquire final (“Record”) image For full automation, the desired features must stay centered during initiation and after interruptions of the series – the tasks are components for ensuring this

Approaches to Automated Tomography Traditional approach: track and focus at every tilt - Used in original Agard/Koster software and in Tietz software - May have to track at low mag: time-consuming Precalibration: take a coarse tilt series to determine X, Y, and focus, then take full tilt series without tracking or focusing - Used in new Koster software for Tecnai and in FEI software - Can be fast but is susceptible to drift and calibrations being off; hard to accommodate user intervention Z-prediction: calibrate tilt axis location and assume specimen moves in a circle around it (new Agard method) - Very fast, but many scopes do not meet the assumptions Robust prediction: predict X/Y/Z position on next tilt from changes in position on previous tilts - Must adapt to non-ideal conditions and user interventions - Goal is to achieve the reliability of traditional approach and speed of precalibration

The Robust Prediction Method in SerialEM Tilt 2Y Tilt 3Y Tilt 4Y Tilt 5Y Make and use prediction but track Rely on prediction – do not track Actual position Predicted position

Tilt Series Preliminaries Adjusting beam and exposure parameters –Tradeoff between specimen damage and signal-to-noise ratio in images and reconstruction –For plastic section work, additional constraints of dynamic range of camera and difficulty of getting drift-free high-exposure image Whether to let program start at zero or go to high tilt “manually” –“Manually” means you refine eucentricity and run walk-up –You would do this if You are not sure you can get to the highest tilt angle You may need to adjust drift settling at high tilt You are unsure of what counts you can reach at high tilt Pre-expose plastic sections to minimize shrinkage and warping during series - ~2000 electrons/Å 2

Tilt Series Setup – the Mother of All Dialogs Tilt and focus parameters are the same as the ones exposed elsewhere – there is just one underlying parameter Some choices will be set/enabled depending on whether you are at zero or already at high tilt Low mag tracking needed only if field of view = ~2 µm field (all assuming well-behaved stage)

Tilt Series Setup 2 - Intensity Control Intensity control is important because otherwise higher tilt images will have lower SNR Intensity control is complicated because it covers several situations; –You might want constant intensity if doing cosine tilting –1/cosine or 1/cosine to a power is preferred for cryo –Use a target # of counts for stained material: 1/cosine can give big variations in counts The problem with constant counts is that it may require too bright a beam at high tilt. Two solutions: –Taper counts down above an angle OK once you are familiar with usable values Use with “Do not increase intensity above value for first saved image” to protect against overconstricted beam at far end of series –Set up intensity before starting and use “Keep intensity below current value” Preferred method if you are starting at high tilt and setting up beam there Can be used even if starting at zero tilt as long as images aren’t too bright there

Tilt Series Setup 3 – Autofocus The autofocus interval sets how often it will focus anyway when predictions are reliable – 5-6° is good value Can focus every time above an angle – not really needed at end of series (should have an option to do this only at start) Checking autofocus is designed to prevent runaway focus changes if autofocus doesn’t work well enough at high tilt –You can follow the advice, i.e. adjust focus manually, and set defocus target to measured defocus value so it will stop trying to change focus –Using an autofocus offset that is the negative of the target defocus might also work –The (rare) problem usually goes away by ~50°

Tilt Series Setup 4 –Initial Actions It is good practice to have a centered image before you go into the dialog, then select the option to align to it You should refine eucentricity before a series, especially after pre- irradiating the specimen Rationale for anchor is that tracking is more likely to drift off at high tilt and is likely to be accurate below 45-50° –Aligning to an image taken during walkup at such an angle will result in desired area being centered at low tilt –There is no data loss from the misalignments at higher tilt, since the drift is lateral to the tilt axis and lost image area is not needed for backprojection You can have it take the anchor when it walks up, or you can to “Walkup & Anchor” before starting series and then select the anchor there

Tilt Series Setup 5 – Tracking Control The defaults are good for normal work (defaults? What defaults? It needs a Reset Defaults button.) “Repeat Record if percentage of field lost…” can be 5% for typical work –Make it smaller, down to 2.5%, if area of interest goes very close to borders at 0 –Make it bigger or turn it off for very high mag or low dose –Maybe make it bigger for very large montages “Get tracking image when error in X/Y prediction >” is typically 1.5%, could be bigger for high mag or low dose work to reduce tracking “Stop if Autoalign shifts more than…” is a protection against wild alignments “Get new track reference if Record alignment differs by >” is relevant if low mag tracking or low dose is in effect; could be relaxed (made bigger) for very high mag

Resuming and Backing Up a Tilt Series A series can be stopped with “End”, at the end of a cycle, or with “STOP”, right away. If you resume from the Setup dialog it goes on to the next step The Resume Dialog gives you options for resuming: –The next action is listed –You can repeat steps on the current cycle or sometimes skip steps that you have taken care of while stopped –You can shift the image in A into a new alignment and check “Use image in Buffer A as reference for alignments” If you take a new Record it automatically overwrites the previous one The Backup dialog lets you back up the tilt angle and overwrite multiple images –When you back up, it tilts the stage back, and loads the Record from that tilt into A and the image from the previous tilt into D, recreating the situation at that tilt –You can open the dialog repeatedly and go forward or backward to the desired point

Verbose Log at Start of Series

Verbose Log with Good Predictions