VISUALIZING ALL THE FITS: Evaluating The Quality And Precision Of Parametric Images Created From Direct Reconstruction Of PET Sinogram Data Evan D. Morris.

Slides:



Advertisements
Similar presentations
Bayesian inference Lee Harrison York Neuroimaging Centre 01 / 05 / 2009.
Advertisements

Active Appearance Models
Principal Component Analysis Based on L1-Norm Maximization Nojun Kwak IEEE Transactions on Pattern Analysis and Machine Intelligence, 2008.
Variability of PET-PIB retention measurements due to different scanner performance in multi-site trials Jean-Claude Rwigema Chet Mathis Charles Laymon.
1 Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration Joonki Noh, Jeffrey A. Fessler EECS Department, The University.
TOMOGRAPHIC IMAGE RECONSTRUCTION FOR PARTIALLY-KNOWN SYSTEMS AND IMAGE SEQUENCES M.S. Thesis Defense :Jovan Brankov.
Nonlinear Regression Ecole Nationale Vétérinaire de Toulouse Didier Concordet ECVPT Workshop April 2011 Can be downloaded at
More MR Fingerprinting
Aspects of Conditional Simulation and estimation of hydraulic conductivity in coastal aquifers" Luit Jan Slooten.
ANALYSIS OF PET STUDIES PET Basics Course 2006 Turku PET Centre Vesa Oikonen
Statistical Analysis fMRI Graduate Course October 29, 2003.
Applications of wavelets in PET modelling - a literature survey.
Statistical image reconstruction
Multiple testing Justin Chumbley Laboratory for Social and Neural Systems Research Institute for Empirical Research in Economics University of Zurich With.
Kernel Methods for De-noising with Neuroimaging Application
Imaging PET Course Layout Class + ContentDateClass Physical Principles of PET I Physical principles of MRI II Imaging applications III.
Concepts for discussion 1.synopses – don’t overdo it 2.how comfortable were you with Wagner paper, Mintun, Farde? 3.non-specific vs specific binding 4.how.
ANALYSIS OF PET STUDIES Turku PET Centre V Oikonen PET Raw Data (sinogram) Results Parametric Sinogram PET Image Parametric Image Regional TACs.
Algorithm Evaluation and Error Analysis class 7 Multiple View Geometry Comp Marc Pollefeys.
Bootstrapping a Heteroscedastic Regression Model with Application to 3D Rigid Motion Evaluation Bogdan Matei Peter Meer Electrical and Computer Engineering.
Signal and Noise in fMRI fMRI Graduate Course October 15, 2003.
Maurizio Conti, Siemens Molecular Imaging, Knoxville, Tennessee, USA
General Linear Model & Classical Inference
1 Assessment of Imprecise Reliability Using Efficient Probabilistic Reanalysis Farizal Efstratios Nikolaidis SAE 2007 World Congress.
From Localization to Connectivity and... Lei Sheu 1/11/2011.
Tracking Pedestrians Using Local Spatio- Temporal Motion Patterns in Extremely Crowded Scenes Louis Kratz and Ko Nishino IEEE TRANSACTIONS ON PATTERN ANALYSIS.
Integrative System Approaches to Medical Imaging and Image Computing Physiological Modeling In Situ Observation Robust Integration.
Coincidence to Image: PET Imaging Jennifer White Marketing Manager SNS Workshop October 13, 2003.
DTU Medical Visionday May 27, 2009 Generative models for automated brain MRI segmentation Koen Van Leemput Athinoula A. Martinos Center for Biomedical.
3D SLAM for Omni-directional Camera
Analysis of fMRI data with linear models Typical fMRI processing steps Image reconstruction Slice time correction Motion correction Temporal filtering.
EE369C Final Project: Accelerated Flip Angle Sequences Jan 9, 2012 Jason Su.
Nuclear Medicine Quality control.
Stochastic Linear Programming by Series of Monte-Carlo Estimators Leonidas SAKALAUSKAS Institute of Mathematics&Informatics Vilnius, Lithuania
Unfolding jet multiplicity and leading jet p T spectra in jet production in association with W and Z Bosons Christos Lazaridis University of Wisconsin-Madison.
2004 All Hands Meeting Analysis of a Multi-Site fMRI Study Using Parametric Response Surface Models Seyoung Kim Padhraic Smyth Hal Stern (University of.
EEG/MEG source reconstruction
Single Photon Emission Computed Tomography
PET/SPECT Phantom. Side View of Phantom Image Resolution Intrinsic resolution FWHM Intrinsic resolution FWHM Field of view Field of view Measurement:
PROCESS MODELLING AND MODEL ANALYSIS © CAPE Centre, The University of Queensland Hungarian Academy of Sciences Statistical Model Calibration and Validation.
Compartment model based analytical PET simulator for PVELab L. Balkay, I. Valastyán, M. Emri, L. Trón UDMHSC, PET Center, Debrecen, Hungary.
July 11, 2006Bayesian Inference and Maximum Entropy Probing the covariance matrix Kenneth M. Hanson T-16, Nuclear Physics; Theoretical Division Los.
Introduction In positron emission tomography (PET), each line of response (LOR) has a different sensitivity due to the scanner's geometry and detector.
The General Linear Model (for dummies…) Carmen Tur and Ashwani Jha 2009.
Impact of Axial Compression for the mMR Simultaneous PET-MR Scanner Martin A Belzunce, Jim O’Doherty and Andrew J Reader King's College London, Division.
Linearized models in PET Vesa Oikonen Turku PET Centre – Modelling workshop Modelling workshop
ISBE-AstraZeneca Strategic Alliance Project # 42 Modelling DCE-MRI Arterial Input Functions in rats Deirdre McGrath, Strategic Alliance meeting 1 st July.
Statistical Analysis An Introduction to MRI Physics and Analysis Michael Jay Schillaci, PhD Monday, April 7 th, 2007.
September 28, 2000 Improved Simultaneous Data Reconciliation, Bias Detection and Identification Using Mixed Integer Optimization Methods Presented by:
The Unscented Particle Filter 2000/09/29 이 시은. Introduction Filtering –estimate the states(parameters or hidden variable) as a set of observations becomes.
GENERATION OF PARAMETRIC IMAGES PROSPECTS PROBLEMS Vesa Oikonen Turku PET Centre
The Unscented Kalman Filter for Nonlinear Estimation Young Ki Baik.
Bayesian inference Lee Harrison York Neuroimaging Centre 23 / 10 / 2009.
Accuracy, Reliability, and Validity of Freesurfer Measurements David H. Salat
Segmentation of 3D microPET Images of the Rat Brain by Hybrid GMM and KDE Tai-Been Chen Department of Medical Imaging and Radiological Science,
Yun, Hyuk Jin. Introduction MAGNETIC RESONANCE (MR) signal intensity measured from homogeneous tissue is seldom uniform; rather it varies smoothly across.
1 C.A.L. Bailer-Jones. Machine Learning. Data exploration and dimensionality reduction Machine learning, pattern recognition and statistical data modelling.
Group Analyses Guillaume Flandin SPM Course London, October 2016
The general linear model and Statistical Parametric Mapping
Conventional Reconstruction Followed by Kinetic Modelling
20 Years of FreeSurfer PETsurfer: MRI-PET Integration using FreeSurfer Nov 17, 2017 Douglas N. Greve, Ph.D. Martinos Center for Biomedical Imaging Massachusetts.
Tianfang Li Quantitative Reconstruction for Brain SPECT with Fan-Beam Collimators Nov. 24th, 2003 SPECT system: * Non-uniform attenuation Detector.
Unfolding Problem: A Machine Learning Approach
Contrasts & Statistical Inference
Model Part – Yiming Weng
Signal and Noise in fMRI
Contrasts & Statistical Inference
Unfolding with system identification
Contrasts & Statistical Inference
COMPTON SCATTERING IN FORWARD DIRECTION
Presentation transcript:

VISUALIZING ALL THE FITS: Evaluating The Quality And Precision Of Parametric Images Created From Direct Reconstruction Of PET Sinogram Data Evan D. Morris 1, Mustafa E Kamasak 2, Bradley T. Christian 3, Tee Ean Cheng 1, Charles A. Bouman 4 1. Indiana University-Purdue University, Indianapolis, 2. Istanbul Technical University, 3. University of Wisconsin-Madison, 4. Purdue University

Dynamic PET 1.PET accumulates/averages the emissions of voxels. 2.Time resolution can be achieved by dividing data into time frames. 3.Used in imaging heart perfusion, brain activation, glucose metabolism, receptor binding 4.Time response of voxels is governed by ODEs 5.Parameters of ODEs are physiologically relevant

2-Tissue Compartment Model Typically used to describe… – Glucose metabolism imaging (FDG) – Receptor availability imaging (11C-raclopride,18F-fallypride) C P, C F, C B - Plasma, Free, and Bound tracer molar concentrations  s = (k 1, k 2, k 3, k 4 ) – kinetic parameters at voxel s Time variation of molar tracer concentrations at voxel s PET signal at voxel s,

Our Approach: Direct Parametric Image Y Notation Y - Sinogram data  - parametric image Objective Directly reconstruct  from Y Problem Nonlinear reconstruction Y k3

Context for Direct Reconstruction Indirect reconstruction –Reconstruct a time-sequence of PET images, and then estimate the kinetic parameters for each voxel. (O’Sullivan and Saha 1999; Zhou 1998, 1999, 2001, 2003) Semi-direct methods –Reconstruct a 4D PET image using splines in time. Then estimate kinetic parameters for each voxel. (Leahy et al. 2002; Reutter et al. 2000, 2004) –Use PCA or subspace methods. Then solve the resulting linear problem. (Wernick et al. 1997, 1999, 2000, 2002) Direct reconstruction proposed by Carson and Lange in 1985 –Proposal based on EM algorithm for tomographic component –No specific proposal for handling kinetic or prior models Direct reconstruction algorithm – (Kamasak, et al. TMI 2005) –Directly compute the image of kinetic parameters from the sinogram data. –Computes MAP estimate of parametric image using general prior model –Can also estimate blood input function

Direct Reconstruction Reconstruction is given by –Y is the sinogram data –A is the forward projection matrix (i.e., the scanner model) –F(  ) is the kinetic model (i.e., the emission image) –  is the image of kinetic parameters (i.e., the parametric images) –S (  ) is the stabilizing function (i.e., the spatial regularizing function) –Λ is the noise covariance For Poisson noise How do we compute the solution? Parametric ICD algorithm (PICD)

Parametric ICD Algorithm Computes the solution to Optimization –ICD optimization for tomographic part of problem –Nested optimization of both linear and nonlinear parts of kinetic model –Allows regularization of general nonlinear transform of parameters –Can directly reconstruction parameters that are physiologically important –Robust convergence, but to local minimum

Direct Reconstruction of Monkey Images from 18F-fallypride Data PFB K1 k2 k3 k4 K1 k4 k2 k3 BPVD

How will we use the parametric images? 1.Map the distribution of binding sites in a single subject over the whole brain. 2.Evaluate the effects of a drug or treatment on binding sites or kinetic rate constants across the whole brain – within subject comparison. 3.Compare the distributions of binding site or rate constant - between groups of subjects.

Present goal: To validate parametric images: i.Check that (kinetic) model is ‘correct’. ii.Determine accuracy of images. iii.Determine variance of images.

How good is the fit of the model to the data in sinogram space? sinogram data with line through single angle fit of events vs. distance residuals of fit vs. distance data model

How good is the fit of the model to the data in image space? This is a big visualization problem. Filtered Back-project residuals from sinogram space to image space. Correlated error -> reject model. Uncorrelated error -> accept model.

Filtered back-project residuals into image space emission image 4-param. model 2-param. model P FB K1 k2 k3 k4 PF K1 k2

Time sequence of FBP’d residuals 4-parameter model gives better fit. 2-parameter model produces spatial clusters in FBP’d residuals

Accuracy of Direct Reconstruction Simulated Rat Brain Data TRUE INDIRECT DIRECT Kamasak, et al. (2005)

Parametric imagesCoefficient of variation images Error in Direct Reconstruction Monte Carlo simulations using 18F-fallypride monkey data Parametric images (ground truth) are forward projected; Poisson noise is added to sinograms multiple times and direct reconstruction is applied to each realization.

k3 imagek3 coeff. of variation Understanding the Error Images high coeff of variation: CSF, muscle (outside skull) low coeff. of variation: striatum, cortex

Experimental Results Protocol: Bolus injection of 18F-fallypride into rhesus monkey 220 min data acquisition on Siemens HR+ (6X0.5min; 7X1min; 5X2min; 4X5min; 18X10min) Corrected for randoms, deadtime, scatter (CTI algorithm), attenuation and normalization Fourier rebinning to 2D sinograms Arterial blood samples collected throughout acquisition Plasma input function corrected for metabolites

Parametric Images of 18F-fallypride (rhesus monkey) PFB K1 k2 k3 k4 K1 k4 Parameterstrength K150 k2100 k k4100 BP0.05 VD0.1 k2 k3 Regularization BPVD Case 1

PFB K1 k2 k3 k4 Parameterstrength K150 k2100 k k4100 BP0 VD0.1 K1 k2 K3 k4 Regularization BPVD Case 2 Parametric Images of 18F-fallypride (rhesus monkey)

Selection of regularization parameters Regional estimates of binding potential ratios – gold standard. Case 2 yields best agreement with regional gold standard values.

Summary Thanks to Mike Casey and Charles Watson of CTI for scatter correction code 1.Direct reconstruction has been implemented and successfully applied to simulated and experimental PET data. 2. Appropriate (kinetic) model order can be determined by examination of filtered-back- projected residual images. 3.Variance of parametric images has been calculated and appears small in gray matter areas. 4.ROI based estimates agree with our results using appropriate regularization.

Future Work 1. Formalize a cluster-detection approach to “goodness of fit” evaluation of back-projected residuals. 2. Implement Variance Image estimation based on the Hessian matrix at each voxel. 3. Implement more general PET kinetic models into direct reconstruction 4. Apply direct reconstruction to new tracers and “calibrate” regularization for each.