A compact RFQ for radio isotope production in hospitals

Slides:



Advertisements
Similar presentations
Final Design of a CW Radio-Frequency Quadrupole (RFQ) for the Project X Injector Experiment (PXIE)* Abstract: The Project X Injector Experiment (PXIE)
Advertisements

Laboratori Nazionali di Legnaro (Italy) DTL design status A. Pisent.
C. Rossi – L4 Project Meeting 3 March 2011 Status and Plans of 3 MeV Test Stand.
MICE Refurbishment of CERN RF equipment for MICE M. Vretenar, CERN AB/RF.
A. Bay Beijing October Accelerators We want to study submicroscopic structure of particles. Spatial resolution of a probe ~de Broglie wavelength.
ERHIC Main Linac Design E. Pozdeyev + eRHIC team BNL.
Before aperture After aperture Faraday Cup Trigger Photodiode Laser Energy Meter Phosphor Screen Solenoids Successful Initial X-Band Photoinjector Electron.
STATUS OF THE TOP-IMPLART PROTON LINAC P. Nenzi 1, F. Ambrosini 3, A. Ampollini 1, G. Bazzano 1, F. Marracino 1, L. Picardi 1, C. Ronsivalle 1, C. Snels.
Front End Test Stand Klystron Commissioning Alan Letchford UKNF Plenary Meeting 22 nd April 2009.
FFAG Fixed Field Alternating Gradient synchrotrons, FFAGs, combine some of the main advantages of both cyclotrons and synchrotrons:  Fixed magnetic field.
The LHC: an Accelerated Overview Jonathan Walsh May 2, 2006.
SRF Results and Requirements Internal MLC Review Matthias Liepe1.
LINAC4 STATUS Alessandra M. Lombardi for the LINAC4 team 1.Motivation and goals 2.Status of Linac4 2 years after official start of the project ( )
The ISIS strong focusing synchrotron also at the Rutherford Appleton Laboratory. Note that ISIS occupies the same hall as NIMROD used to and re- uses some.
Activities of Superconducting RF Accelerators at Nanjing University Sun An Proton Linear Accelerator Institute Institute of Energy Sciences, Nanjing University.
Low Emittance RF Gun Developments for PAL-XFEL
CAS, BilbaoMueller, Ugena, Velez, Zerlauth May 31 st v0 SCC – Industrial ADS.
1 Linac4 Overview M. Vretenar, SLHC Meeting, Motivations 2.Layout 3.Main parameters 4.Schedule 5.Status.
ACCELERATING A CYCLOTRON 18 MEV PROTON BEAM BY A SCDTL LINAC Luigi Picardi, Concetta Ronsivalle (ENEA C.R. Frascati, Frascati (Roma)), Paola Panichelli,
January 5, 2004S. A. Pande - CAT-KEK School on SNS MeV Injector Linac for Indian Spallation Neutron Source S. A. PANDE.
Alexander Aleksandrov Oak Ridge National Laboratory
FFAG F ixed F ield A lternating G radient Synchrotrons A new type of particle accelerator - with a wide variety of applications Cancer Therapy and UK Activities.
Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,
PROTON LINAC FOR INDIAN SNS Vinod Bharadwaj, SLAC (reporting for the Indian SNS Design Team)
CLARA Gun Cavity Optimisation NVEC 05/06/2014 P. Goudket G. Burt, L. Cowie, J. McKenzie, B. Militsyn.
Development of The Klystrons for J-PARC Project
NEUTRINO DETECTORS Cutting-Edge Accelerator Research for a Neutrino Factory and Other Applications Ajit Kurup for the FETS and UKNF Collaborations Cutting-Edge.
Design Optimization of MEIC Ion Linac & Pre-Booster B. Mustapha, Z. Conway, B. Erdelyi and P. Ostroumov ANL & NIU MEIC Collaboration Meeting JLab, October.
Linac4 Status 1 M. Vretenar sLHC public event
MP - HIPPI General meeting, Abingdon October 28-30, Side Coupled Linac Design at CERN Side Coupled Linac Design at CERN M. Pasini, Abingdon September.
Radio Frequency Quadrupole
State-of-the-Art Accelerator Technology Peter McIntosh, STFC HEPTech Environmental Applications of Accelerators 9 th July 2013.
ENLIGHT,12/2/20021 Health and Science, can CERN contribute? The Mission of CERN (1954): “The Organization shall provide for collaboration among European.
Comparison of Fermilab Proton Driver to Suggested Energy Amplifier Linac Bob Webber April 13, 2007.
LINAC4 and the Upgrade of the LHC Injector Complex R. Garoby 26 February, 2013.
The International Workshop on Thin Films. Padova 9-12 Oct of slides Present Status of the World- wide Fusion Programme and possible applications.
ESGARD – OMIA 10 & 11/09/2007 JRA on Sc cavities and Cryomodule for a Pulsed proton Linac Motivation Work Packages Partners & resources R. Garoby for S.
Concept Preliminary Estimations A. Kolomiets Charge to mass ratio1/61/8 Input energy (MeV/u) Output energy (MeV/u)2.5(3.5) Beam.
BEAM DYNAMICS IN A HIGH FREQUENCY RFQ Alessandra M Lombardi S. Myers : head of office for medical applications at CERN The “750MHz” team (layout and beam.
THE LINAC4 RFQ – Experience with Design, Fabrication and Tuning C. Rossi and the RFQ Project Team GSI Review – 20 November 2013.
THE MAFF IH-RFQ TEST STAND AT THE IAP FRANKFURT A. Bechtold, J. Fischbach, D. Habs, O. Kester, M. Pasini, U. Ratzinger, J. Rehberg, M. Reichwein, A. Schempp,
PXIE RFQ Engineering Design Steve Virostek Engineering Division Lawrence Berkeley National Laboratory April 10, 2012 Project X Collaboration
High-efficiency L-band klystron development for the CLIC Drive Beam High-efficiency L-band klystron development for the CLIC Drive Beam CLIC workshop,
M. Munoz April 2, 2014 Beam Commissioning at ESS.
PXIE RFQ Design Overview Derun Li for PXIE RFQ Design Team Center for Beam Physics Accelerator and Fusion Research Division Lawrence Berkeley National.
Plans and Activities at CERN
Linac4 & SPL Status of preparation and Opportunities M. Vretenar (R
How does a klystron work? TE-MPE Section Meeting Karolina Kulesz
Present and possible future schemes for hadron therapy linacs Alberto Degiovanni for the ADAM team HG2017 Workshop , Valencia.
High efficiency work and MBK development for accelerators
Progress in the Multi-Ion Injector Linac Design
M. Migliorati, C. Vaccarezza INFN - LNF
Physics design on Injector-1 RFQ
SPES-RFQ review Introduction, general aspects
How to run ions in the future?
Part2: Cavities and Structures
Superbeams with SPL at CERN
EffiCAS Efficient Facility for Ions at CAS
CEPC RF Power Sources System
ADS Accelerator Program in China
Pulsed Ion Linac for EIC
Collective Effects and Beam Measurements in Particle Accelerators
Advanced Research Electron Accelerator Laboratory
Part2: Cavities and Structures
Physics Design on Injector I
The SPL-based Proton Driver at CERN
RF introduction Anders Sunesson RF group leader
ERL Director’s Review Main Linac
Status of the JLEIC Injector Linac Design
Multi-Ion Injector Linac Design – Progress Summary
Presentation transcript:

A compact RFQ for radio isotope production in hospitals Office for CERN Medical Applications A compact RFQ for radio isotope production in hospitals M. Vretenar for the HF-RFQ Working Group V.A. Dimov, M. Garlasché, A. Grudiev, A. Lombardi, D. Mazur, S. Mathot, E. Montesinos, M. Timmins, M. Vretenar

A long-term vision… Particle accelerators are not only scientific instruments, they are unique tools to interact with atomic nuclei and subatomic particles. The technologies related to manipulations of the atomic structure of the matter offer many opportunities for society that are only partially exploited, because of cost, of “radiophobia”, and of lack of contacts between laboratories and industry. New opportunities: cost of key technologies is decreasing, better regulation and understanding of radiation are slowly increasing the social acceptance of nuclear- related technologies, more attention is given to technology transfer from science to society. There is space for bringing more accelerator technology out of scientific laboratories to society: what is needed are compact, easy to operate, low radiation and low cost proton (and ion) accelerators able to cover several medical and industrial applications. Among the different applications, medicine has the priority. Medicine is becoming the main technology driver of 21st century (as defense was the technology driver of 20th century).

Specifications Dreaming of the pocket-size accelerator: Brings protons above Coulomb barrier Fits in your kitchen (or in a standard industrial environment) Allow you to stay in (or next to) your kitchen while it works (low radiation!) Cheap, reliable and maintenance-free AVAILABLE IN THE VIRTUAL WORLD: In “The SIMS” (life simulation video game) you can already buy: “the smallest and cheapest particle accelerator in the world. Produce new subatomic particles in the comfort and intimacy of your home. Notice: a wrong usage could destroy the planet.”

Linacs vs. cyclotrons Industrial and medical applications: standard low-energy accelerator is the cyclotron. Most of scientific applications: low-energy acceleration provided by linear accelerators. Two different (competing?) technologies coming from the same origin, the work of Ernest O. Lawrence team at Berkeley in the 30’s – great success of the cyclotron, interest for linacs came only after WWII when high RF frequencies became available. Principle Operation Focusing Extraction Beam quality RF power Cost Maintenance CYCLOTRON Cyclic (magnet based) CW Weak Lossy Average Low Higher LINAC Linear (RF based) Pulsed Strong Clean Good High High? Lower E. O. Lawrence 12 MeV section (from left, DTL1, RFQ, source) of the CERN Linac4 under commissioning at CERN. Linac4 is 80 meters, 160 MeV, 80 MEUR (500 kEUR/MeV building and infrastructure included)

Modern linacs: the RFQ Acceleration up to 5 – 10 MeV by the RFQ = Radio Frequency Quadrupole A relatively new technology (invented in Russia in the 70’s, first prototype RFQ in the USA 1980, becomes the standard low-energy linac from the 90’s). Follows the ion source and can simultaneously accelerate, focus and bunch large currents of protons and ions up to several MeV’s without beam loss and with excellent output beam quality. Reliable (one-button machine), no maintenance, but relatively high construction cost The CERN Linac4 RFQ, 0.05 to 3 MeV, 3 m. Four electrodes (“vanes”) provide a quadrupole focusing field, a sinusoidal profile machined on the vane tips provides acceleration.

Pushing the RFQ limits 1990 RFQ2 200 MHz 0.5 MeV /m Weight : 1000 kg/m Ext. diameter : 45 cm 2007 LINAC4 RFQ 352 MHz 1MeV/m Weight : 400kg/m Ext. diameter : 29 cm 2014 HF RFQ 750MHz 2.5MeV/m Weight : 100 kg/m Ext. diameter : 13 cm New development at 750 MHz Smaller, less expensive construction More cells/unit length, shorter But: Lower current capability Same range of RF power HIGHER FREQUENCY Initial RFQs in the 200 MHz frequency range Later, 400 MHz range (Linac4, 352 MHz). New frequency range 700 – 800 MHz Fabrication cost per meter about 50% at 750 MHz w.r.t. 350 MHz

Why linacs ? The HF-RFQ team at the CERN Linac2 the source of all protons for the LHC Behind the group, the Linac2 RFQ (0.09-0.75 MeV), to the right the orange DTL Tank1 (10 MeV). Note 1: in Alessandra Lombardi’s hands, a pole of the new RFQ (50 cm), providing the same energy gain of the Linac2 RFQ (1989, 1.8 m). Note 2: during the photo session, Linac2 was accelerating protons for the LHC with a peak current of 180 mA (18 mA average) present in the linac. There is no shielding towards the high-energy side. Linacs are virtually loss-free, all beam loss is concentrated in the target.

Technological Roadmap 1. Injector for proton therapy linac 5 MeV Low current Low duty cycle (<1%) In construction 2. Isotope production in hospitals 10 MeV Medium duty cycle (<5%) Design 3. Brachytherapy isotopes or Technetium production in dedicated centers 20 MeV Includes DTL linac High current High duty cycle (10%) Preliminary design Develop a modular high-frequency RFQ design covering 3 applications: Increasing complexity from one step to the next, will profit of experience from previous step Proton therapy RFQ at 750 MHz (submultiple of 3 GHz), others in range 700-800 MHz

RFQ for Proton therapy 2 examples of proton therapy linacs using the HF-RFQ as injector

Basic parameters Step 1 Step 2 Step 3 Application: Injector for Hadron Therapy Accelerator PET Isotope Production 99mTc Production Isotope Production for Brachytherapy Particle: p+ α / d+ Beam energy (MeV) 5 10 18 20 Accelerator length (m) 2 4 ≈10 Average current (mA) 0.015 0.02 1 ~0.1 Peak current (mA) 0.3 0.5 ~1 RF Frequency (MHz) 750 704 Duty Cycle (%) < 1 Peak RF Power (kW) 400 800 ≈1500 Note: higher current (~10 mA) can be obtained with a lower frequency RFQ (eg. 350 MHz)

The isotope RFQ system To be installed in hospitals (or movable on a lorry?) 2 (or more) movable targets. Target shielded by layers of iron and borated (6%) polyethylene, overall radius <0.9 m. Maximum calculated dose at shielding 2 mSv/h

Parameters for compact isotope RFQ system Input energy = 40 KeV Total Length = 4.0 m Output Energy = 10 MeV Frequency 750 MHz Average current = 20 mA Peak current = 500 mA Duty cycle = 4 % Peak RF power < 800 kW Total weight (RFQ): 500 kg Mains power < 65 kW Cooling ~ 100 l/min No radiation around accelerator and target. Easy operation (one button machine). High reliability Minimum footprint (15 m2) Production for PET scans of 18F and 11C

Industrial partnerships Step 1: Initial development and RFQ construction financed by CERN Office for Medical Applications. Testing and validation under partnership agreement with ADAM (Application of Detectors and Accelerators to Medicine, part of the UK Group AVO Advanced Oncotheraphy). ADAM provides the components and infrastructure for testing the RFQ with beam and will test the RFQ in front of its prototype hadron therapy linac (the LIGHT project). Step 2, isotope production: CERN is developing the design of RFQ and target shielding, and is planning innovative designs for the RF power sources. Presently looking for partners (scientific and industrial, option of using the SME instrument of Horizon 2020). Step 3, brachytherapy: to be developed in a collaborative environment (European project?). In parallel: Intellectual property related to the novel RFQ is open for licensing

RFQ Mechanical design Mechanical design and construction procedure based on the Linac4 RFQ: 4-vane structure with 2 brazing steps. Inner radius 46 mm; total weight 220 kg. Mechanical tolerances ±20 µm (cavity), ±10 µm (vane tip). Assembly tolerance for the four vanes ±15 µm. Surface finishing Ra=0.4 µm. Modular design: assembly of four 0.5 m long modules, each with 8 tuning ports and 4 combined tuner/power coupler ports. The modules differ only by the vane modulation (and for the end cells at both ends).

A small RFQ… Major Vane, rough machined Modulation test machining

Beam dynamics Compromise between transmission efficiency and acceleration per unit length; controlled beam loss at energies < 500 keV (transmission efficiency only 30%); 99.5% of the lost particles have an energy below 100 keV. Controlled particle loss: The design is such that particles that could be lost at high energy are instead eliminated at low energy, below the activation threshold. Output Phase Spaces

RF Cavity design Set of detailed 3D simulations; developed a strategy for tuning long RFQs (5l). Minimised power consumption (optimization of the transverse cross-section, reduction of vane voltage). Conservative power factor of 1.5 as a margin for all 3D and surface effects → RF power 400 kW. Detailed and innovative design of tuners (low power consumption).

RF amplifiers Basic concept: Combine several small RF amplifiers into the RFQ (that acts like a combiner). The RFQ for proton therapy will be fed by an arrangement of 4 IOT-based amplifiers on a common modulator, each connected to an RF coupler. Most economic and easier to procure option. For the isotope production RFQ, solid-state amplifiers will be used for reduced cost and increased reliability (no HV, hot exchange of faulty modules). Profit of the rapid increase of power and decrease of cost of RF transistors. Develop «stripped-down» units with minimum control and electronics. Use innovative architectures.

Construction Status First completed major vane Shape tools made by the company BOUDON-FAVRE, Feillens (F)e). Precision machining obtained with a CNC grinding machine ANCA type mx7 with camera control Iview

Minor vanes Rough to Final Machining

Construction and testing HF-RFQ Production Planning, version 20 Mars 2015   2014 2015 2016 Jun. Jul. Aug. Sept. Oct. Nov. Dec. Jan. Feb. Mar. Apr. May Apr Design RF T2 & T3 Pre-rough machining Rough machining Partial finishing Finishing Control/Preparation Brazing 1 Contrôle Re-Machining 1 Brazing 2 Control Final machining T1 & T4 Final Assembly RF Power tests Final assembly foreseen for April 2016. Low-power and high-power RF tests will follow in 2016.

Technetium production Energy of 20 MeV for production of 99mTC 704 MHz 2 RFQs + 1 DTL Source W = 90 KeV L = 10 m Output W = 18 MeV Average current = 1 mA Peak current = 10 mA Duty cycle = 10 % 1. High-frequency RFQ option (low cost, low current) 2. Conventional RFQ option: copy of Linac4 352 MHz 1 RFQs + 2 DTL tanks Source W = 45 KeV L = 12 m Output W = 20 MeV Average current = 10 mA Peak current = 100 mA Duty cycle = 10 % 2 klystrons @ 352 MHz Hands-on maintenance on accelerator (<1 W/m beam loss)

Conclusions For the production of radio isotopes, modern linear accelerators can be a viable alternative to cyclotrons, in particular in environments requiring limited radiation levels and/or presenting constraints in terms of space and shielding and thanks to their qualities of ease of operation and limited maintenance. We welcome scientific and industrial partners for the next step: build and test with beam the isotope version of the RFQ. Maurizio.Vretenar@cern.ch