Early Experience of a Commercial Available Robot (Maxio) for CT-guided Radiofrequency Ablation of liver tumours 1 BJJ Abdullah, 1 CH Yeong, 2 KL Goh, 3.

Slides:



Advertisements
Similar presentations
In the past few years the usage of conformal and IMRT treatments has been increasing rapidly. These treatments employ the use of tighter margins around.
Advertisements

Intraoperative Iso-C C-arm navigation surgery for spinal and pelvic trauma Kobe Red Cross Hospital Yasuo Ito K. Koshimune, T. Takigawa, S. Nakahara, T.
Laser Needle Guide for the Sonic Flashlight David Wang 1,3,4, Bing Wu 2,3, George Stetten 1,2,3,4,5 1 Department of Biomedical Engineering, Carnegie Mellon.
Visual Servoing for Automatic and Uncalibrated Percutaneous Procedures Ming Li Computer Integrated Surgery II /3/13.
Acetabular fractures: the first three days.
Arizona’s First University. Feasibility of Image-Guided SRS for Trigeminal Neuralgia with Novalis.
Radiofrequency Ablation of Lung Cancer
Robotic Needle End Effector for Integration with CT Scan Team Members: David Sun Xuan Truong Chris Willingham Advisor: Dr. Bradford Wood.
Computer Science AND DOCTORS Jolena Co Truong- 6 th period.
By : Alanoud Al Saleh. What is PACS quality control ? The PACS monitor quality control (QC) program objectives are:  to ensure consistent display performance.
A. NEFFATI, N. DALI, O. NESSEJ, A. AMANAMANI, L. BEN FARHAT, L. HENDAOUI - Radiology Department, Mongi Slim Hospital, Marsa, Tunisia PERCUTANEOUS NEPHROSTOMY.
A user-friendly, stand alone system for sensitive and reliable breath-hold monitoring.
Radiofrequency ablation of lung tumours Michelle Muller Consultant Radiologist Freeman Hospital.
Treatment Planning Optimization for Radiofrequency Ablation of Hepatic Tumors Hernán Abeledo, Ph.D. Associate Professor Engineering Management and Systems.
Response to Intervention in The Social Domain. Response to Intervention (RTI) Response to evidence-based interventions (Elliott, Witt, Kratchowill, &
Percutaneous CT-Guided Cryotherapy of Renal Masses: Long-term Follow-up and Morbidity. Hussein D. Aoun, M.D Wayne State University / Detroit Medical Center.
Tumor Localization Techniques Richard Kao April 10, 2001 Computer Integrated Surgery II.
Safety Consideration Software limits on robot controller Limit switches on the robot “wrist” to prevent excess rotations Limit switches on the vertical.
ACRIN 6673 Percutaneous Radiofrequency Ablation of Hepatocellular Carcinoma in Cirrhotic Patients: A Multi-Center Study.
Evaluation of the Performance of the Fast Scanning Platform of an OCT System Malcolm Heard 1, Miguel Herrera 1, Geoffrey Ibbott 1 1 Department of Radiation.
Purpose of the Interactive Breath-Hold Control System To improve CT-guided biopsies of the lung or upper abdomen by allowing consistent, optimal visualization.
BREAST MRI IN RADIATION THERAPY PLANNING MARSHA HALEY, M.D. ASSISTANT PROFESSOR UNIVERSITY OF PITTSBURGH CANCER INSTITUTE PITTSBURGH, PENNSYLVANIA, USA.
MRI-Ultrasound Fusion-Guided Biopsy of the Prostate: Results of Initial Experience in a Radiation Oncology Department Department of Radiation Oncology.
CT physics and instrumentation
FDA Public Meeting: Device Improvements to Reduce the Number of Under-doses and Misaligned Exposures from Therapeutic Radiation.
Low Dose Head Computed Tomography Protocol for Evaluation of Non-traumatic Emergencies in Children Rishi Mhapsekar, MD Marilyn J. Siegel, MD Robert McKinstry.
COMBI RECIST 1.1 February Target Lesions: Selection at Baseline Perform baseline evaluations as close to treatment start as possible (no more than.
RECIST Overview.
Reduction of effective and organ dose to the eye lens in cerebral MDCT scans using iterative image reconstruction Zizka J, Jandura J, Kvasnicka T, Klzo.
Evaluation of Lesion Size for Water-Cooled Cervical Radiofrequency Ablation (RFA) and the Effects of Various Injectates and their Volume on the Lesion.
PERCUTANEOUS CT-GUIDED BIOPSY OF THE MUSCULO-SKELETAL SYSTEM: RESULTS OF 1722 CASES E. Rimondi, P. Ruggieri, G. Bosco, G. Ussia, T. Calabrò, A. Angelini,
Percutaneous Cryoablation for Renal Cell Cancer Christos Georgiades MD PhD Assistant Professor of Radiology & Surgery Vascular & Interventional Radiology.
We retrospectively analyzed 58 patients with ONSM treated between on a dedicated 6 MV stereotactic LINAC. All cases were discussed in a multidisciplinary.
NA-MIC National Alliance for Medical Image Computing An Integrated System for Image-Guided Radiofrequency Ablation (RFA) of Liver Tumors.
Requirements Document Slicer3 Workflow Based Interface for NAV-RFA.
* AP: Anteroposterior, Lat: Lateral Tumor diameter, tumor length, depth of penetration, distance from the anal verge, deep and narrow pelvic dimension.
Neil A. Martin (Surgical PI) Paul M. Vespa (Medical PI)
The Application of Multi-detector Computed Tomography in RVOT Ablation in BRUGADA’ s Syndrome Paweena Mapinta R.T, Cardiac Imaging Unit, Bangkok Heart.
Anthropomorphic Liver Phantom for CT and Ultrasound Katelyn Herbert Advisor: Dr. Robert Galloway (BME) Department of Biomedical Engineering, Vanderbilt.
Limitations of RECIST guidelines Srinivasa R Prasad MD Associate Professor, Radiology University of Texas Health Science Center at San Antonio.
PACS in Radiology By Alanoud Al Saleh.
©2005 Surgical Planning Laboratory, ARR Slide 1 Prostate Image Processing Steven Haker, PhD.
Assessment of radiotherapy set-up error for limb sarcoma using electronic portal imaging (EPI) Wendy Ella, Eleanor Gill, Anna Cassoni, Beatrice Seddon.
Image-Based 3-D Spinal Navigation Using Intra-Operative Fluoroscopic Registration R. Grzeszczuk, S. Chin, M. Murphy, R. Fahrig, H. Abbasi, D. Kim, J.R.
IRE of HCC with robotic assistance Lukas P. Beyer, Benedikt Pregler, Christoph Nießen, Philipp Wiggermann.
What are the dose quantities in CT ? IAEA/RCA Kampala Kampala.
Developing outcome prediction models for acute intracerebral hemorrhage patients: evaluation of a Support Vector Machine based method A. Jakab 1, L. Lánczi.
Monday Case of the Day A) The treatment was successful: The bremsstrahlung SPECT (Fig 2) indicates that 90 Y was deposited in the tumor. B) The treatment.
Carmel McDerby Clatterbridge Centre for Oncology, Merseyside,UK
LifeCIT Development and pilot evaluation of a web-supported programme of Constraint Induced Therapy following stroke (LifeCIT) Meagher C 1, Conlon A 2,
N. Kuo, H.J. Kang, T. DeJournett, J. Spicer, and E. Boctor Proc. SPIE 7964, (2011); doi: / Photoacoustic Imaging of Prostate Brachytherapy.
Fotlos Laspas'. Evangelia Sotiropoitlou'. Sophia Myhna^. Anita Manataki', Paraskevi TsagouW. Iris Tsangaridou', Loukas Thanos'
Enabling Technologies for Natural Orifice Transluminal Endoscopic Surgery (N.O.T.E.S) using Robotically Guided Elasticity Imaging N.O.T.E.S Natural orifice.
Dr. Malhar Patel DNB (Radiation Oncology)
By: Matthew Kosch Advantages and Recent Implementation of Fiducials in Image-Guided Radiation Therapy.
Rapid on-site evaluation may optimize patient selection for radio-frequency-ablation therapy Dr Wolfgang Pokieser Pathologisch-bakteriologisches Institut.
Radiological Sciences Department Ph.D., Paris-Sud 11 University
Brain imaging prior to lung cancer resection
New imaging techniques in orthodontics
CT dose optimization software synergy – A clinical perspective
PRACTICAL APPLICATION OF Diagnostic Reference Levels
CT-based surrogates of pulmonary ventilation in lung cancer:
Recent Advances in Bronchoscopic Treatment of Peripheral Lung Cancers
Andrew Wright MD, Chris Johnson, Fred Lee Jr. MD, and David Mahvi MD
Robotic Needle End Arm Effector for Integration With CT Scan
Robotic Needle End Arm Effector for Integration With CT Scan
Ultrasound-Guided Percutaneous Breast Biopsy
Intensity-based biplane 2D-3D registration for in-vivo three dimensional forearm rotational analysis Shingo Abe1,3, Kunihiro Oka1, Yoshihito Otake2, Yuusuke.
Robotic versus Freehand Needle Positioning in CT-guided Ablation of Liver Tumors: A Randomized Controlled Trial Heerink WJ et al. Published Online: Jan.
Presentation transcript:

Early Experience of a Commercial Available Robot (Maxio) for CT-guided Radiofrequency Ablation of liver tumours 1 BJJ Abdullah, 1 CH Yeong, 2 KL Goh, 3 BK Yoong, 4 GF Ho, 5 Anjali Kulkarni   1 Department of Biomedical Imaging and University of Malaya Research Imaging Centre, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia. Departments of 2Internal Medicine, 3Surgery and 4Oncology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia. 5Perfint Healthcare Corporation, Florence, OR 97439, United State.

Challenges in Ablation Visualization Planning Limited Tools Tumor visualization difficult in many cases Current fusion techniques - Cumbersome Impossible to visualize related structures Skill dependent Ablation zone Validation Positioning No tool to validate Needle visualization Complex spatial orientation of organs Patient follow up Multiple needle Big Learning Curve Ablation tool lacks the critical level of control, accuracy, stability, and guaranteed performance (Emad M. Boctor et. Al, 2004) Local tumor progression occurs due to failures in establishing ablative margin (Minami & Kudo, 2011)

Challenges of current CT-guided RFA Real time Target Entry point Angle Depth High CT fluoro dose Repeated Punctures The current practice of CT guided RFA is a challenging procedure by nature. It requires real time assessment from tumour targeting to therapy. Due to the CT-guided properties, it often induce high radiation dose to both patients and working personnel. Repeated needle punctures may be necessary to adjust positioning to the target volume. The whole procedure is often time consuming and challenging. Time Consuming ECR 2014, Vienna

Robotic-Assisted RFA MAXIOTM (Perfint Healthcare Pvt Ltd, Oregon, USA) MAXIO console MAXIO Recently, there is a robotic device introduced to assist tumour targeting in the CT-guided interventional procedures, such as biopsy, cancer ablation, FNAC, drainage and pain management. The device is named ROBIO EX, which is a trademark registered by the Perfint Healthcare, USA. The ROBIO EX can be connected to a CT or PET/CT scanner through InstaReg technology and communicated to the DICOM network using Ethernet. Treatment planning can be done on the robot’s console to accurately target to the tumour volume. The depth of tumour, length of needle and angulation of needle insertion are calculated by the robot. Once confirm and execution, the robotic arm will automatically move to the accurate coordinates for needle insertion. The radiologist will just need to insert the needle through the bush on the robotic arm. MAXIOTM (Perfint Healthcare Pvt Ltd, Oregon, USA) ECR 2014, Vienna

Purpose of Study To assess the accuracy of needle placement, radiation dose and performance level during robotic-assisted radiofrequency ablation (RA- RFA) of liver tumours using a CT-guidance robotic system (MAXIO, Perfint Healthcare, USA). ECR 2014, Vienna

Methodology 19 patients (39 lesions, <5.0 cm diameter) were treated with RA-RFA. All the procedures were performed under GA. Following baseline CT scans the lesions were identified. The CT images (1 mm reconstructed SL) were registered to the MAXIO workstation for treatment planning. Target point (X, Y, Z) and needle entry point were determined during the treatment plan. The needle trajectory path, angulation and depth of lesion were calculated and shown on the treatment plan. ECR 2014, Vienna

Methodology The plan was carefully checked to avoid any critical organs or bone across the trajectory. Once the plan was confirmed, MAXIO was executed. The robotic arm then moved automatically to the planned location and the radiologist inserted the RFA needle through the bush holder at the end-effector of the robotic arm. Post-needle insertion, a CT-fluoro was done to confirm accurate placement of the needle within the target volume. ECR 2014, Vienna

Methodology The accuracy of needle placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated for each procedure on a five-point scale (5-1: Excellent-Poor) by the operated radiologist. The radiation doses and readjustments were then compared against 30 RFA patients treated without robotic assistance. ECR 2014, Vienna

Adaptive Intra-op. registration Post procedure confirmation Image Registration Segmentation Simulation Adaptive Intra-op. registration SCAN PLAN VISUALISE EXECUTE With the assistance of robotic systems, clinicians can now visualize and plan an entire ablation procedure in 3D - pre-operative registration, segmentation and visualization of multiple VOI, multi probe placement planning, estimated ablation volume and probe placement sequence, before advancing a single probe into the patient. Once the plan is confirmed, the robotic targeting system provides spatial positioning and orientation for a probe guide, through which the clinician then carefully insert each probe and performs the ablative procedure. VALIDATE MaxioTM Robotic Targeting Post procedure confirmation ECR 2014, Vienna

ECR 2014, Vienna

ECR 2014, Vienna

Results All 39 lesions were targeted successfully. No immediate complications were noted in all the patients. RA-RFA Conventional RFA P-value Average number of needle readjustment 0.8 ± 0.8 Performance level 4.7 ± 0.5 CT Fluoro Dose per Lesion (DLP, mGy.cm) 422.27 ± 370.611 (-16%) 501.20 ± 366.54 P>0.05 Total CTDIvol per patient (mGy) 534.71 ± 397.74 (-6%) 567.33 ± 398.62 Total DLP per patient (mGy.cm) 1390.37 ± 549.02 (-14%) 1611.27 ± 708.38 ECR 2014, Vienna.

Conclusion Robotic-assisted planning and needle placement appears to be technically easier requires fewer number of needle passes fewer check scans lower radiation dose (patient & staff) Study with large sample size is needed to confirm these preliminary findings. ECR 2014, Vienna

Other Potential Advantages of RA-RFA Time Pain Allows access to difficult lesions Accuracy & consistency Level of confidence & safety ECR 2014, Vienna

References BJJ Abdullah, CH Yeong, KL Goh, BK Yoong, GF Ho, Carolyn Yim, Anjali Kulkarni. Robotic-assisted radiofrequency ablation of primary and secondary tumours. European Radiology, Vol 23(9), 2013. Perfint Healthcare Corporation official website. www.perfinthealthcare.com ECR 2014, Vienna