Residential Clothes Washers and Dryers Technical Subcommittee Ryan Firestone & Christian Douglass Regional Technical Forum March 10, 2015 1-3 PM.

Slides:



Advertisements
Similar presentations
Residential Refrigerators and Freezers UES Measure Update Regional Technical Forum October 14, 2014.
Advertisements

Direction on Guidelines Savings Definition Path Results of straw vote and proposed decisions for elements of the savings definition Regional Technical.
 Using the “How to Read the EnergyGuide Label” and EnergyGuide examples fill in the template below (1) Estimated Yearly Operating Cost (Natural gas water.
Residential Single Family Clothes Washer UES Measure Update Christian Douglass Regional Technical Forum February 18, 2015.
Commercial Clothes Washer UES Measure Update Regional Technical Forum February 19, 2014.
D EEMED M EASURE R EVIEW P ROJECT Final Report December 7, 2010 Regional Technical Forum Presented by: Michael Baker.
Residential LED UES Measure Update Regional Technical Forum August 20, 2013.
Residential Refrigerators and Freezers UES Measure Update Regional Technical Forum October 14, 2014.
The Saga Continues: Measure Interactions for Residential HVAC and Wx measures Regional Technical Forum April 23, 2014.
Residential and Commercial Storage Electric Resistance Water Heaters (Efficient Tanks) Mohit Singh-Chhabra Regional Technical Forum February 18, 2015.
Residential Clothes Washers and Dryers Ryan Firestone, My Ton, and Christian Douglass Regional Technical Forum April 14, 2015.
©2011 Navigant Consulting, Inc. Confidential and proprietary. Do not distribute or copy. ENERGY DISPUTES & INVESTIGATIONS ECONOMICS FINANCIAL ADVISORY.
Heat Pump Water Heaters Provisional UES Proposal Regional Technical Forum October 4 th, 2011.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Manufactured Homes Calibration: Existing and New Homes Mohit Singh-Chhabra & Josh Rushton RTF Update March 17, 2015.
Research Strategy Review: Heat Pump Water Heaters Thermostatic Restriction Valves Jennifer Anziano RTF R&E Subcommittee July 8, 2015.
Heat Pump Water Heater (HPWH) Subcommittee Christian Douglass Regional Technical Forum June 18, 2015.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Implementer’s Group April 2015 Meeting Debrief and Upcoming Meeting Prep April 24, 2015.
Northwest Power and Conservation Council Deemed Energy Savings and Cost-Effectiveness of 80-Plus Power Supplies RTF January 2007.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Pre-Rinse Spray Valve Small Saver UES Measures Regional Technical Forum September 17, 2013.
Standard Information Workbook Update Regional Technical Forum May 21, 2013.
©2011 Navigant Consulting, Inc. Confidential and proprietary. Do not distribute or copy. ENERGY DISPUTES & INVESTIGATIONS ECONOMICS FINANCIAL ADVISORY.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
Agricultural Irrigation Pump Variable Frequency Drive Provisional Standard Protocol Proposal Regional Technical Forum April 16, 2013.
1 Retail Plug-Load Portfolio (RPP) Program Proposed Basic Tier Product UESs EM&V and Residential Program Teams September 24, 2015.
Delivery Verification Jennifer Anziano Regional Technical Forum March 17, 2015.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Residential Appliance Measure Updates Danielle Gidding Bonneville Power Administration.
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
Residential Single Family and Manufactured Home Heat Pump Water Heaters Christian Douglass Regional Technical Forum 4/14/2015.
Refrigerator Decommissioning: Measure Status Update Regional Technical Forum October 16, 2013.
Update: Grocery Refrigeration Provisional Standard Protocol for Site Specific Savings RTF Meeting June 28,
RTF Delivery Verification Guidance Batch 1 Jennifer Anziano Regional Technical Forum May 12, 2015.
Ben Chou NRDC Water Program Clothes Washer Recycling Work Paper Abstract California Technical Forum October 23, 2014.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Energy Savings from Electric Water Heaters in Commercial Applications Danielle Gidding.
Integration Issues for RTF Guidelines: Savings, Lifetimes and Cost/Benefit October 24, 2012 Regional Technical Forum Presented by: Michael Baker, SBW.
Implementer’s Group July 2015 RTF Meeting Debrief and Upcoming Meeting Prep July 29, 2015.
1 Analysis of Two-Tiered Deemed Savings Values for Energy Star Clothes Washers February 10, 2004.
RTF Management Update Jennifer Anziano Regional Technical Forum February 18, 2015.
Guidelines Revisions Defining What RTF Means by “Savings” December 17,
Proposed Deemed Savings Rates for Energy Star 3.0 Plus 30% Televisions By Christina Steinhoff June 1,
Residential New SF Energy Star Homes Idaho and Montana UES Measure Updates: Energy Star Homes, DHP TCO Homes, and BOP2 Homes March 18 th, 2014.
Residential New SF Energy Star Homes UES Measure Update December 17th, 2013.
PTCS Commissioning, Controls & Sizing Update of UES Measure Category and/or Status Regional Technical Forum July 15, 2014.
Research Strategy: Residential Clothes Dryers R&E Subcommittee Ryan Firestone, Christian Douglass, My Ton Regional Technical Forum April 3, 2015.
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum March 18, 2014.
Commercial Clothes Washers UES Ryan Firestone Regional Technical Forum April 14, 2015.
RTF Management Updates Jennifer Anziano Regional Technical Forum October 20, 2015.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Commercial Clothes Washer UES Measure Update Regional Technical Forum April 16, 2013.
Residential Showerheads UES Update Ryan Firestone Regional Technical Forum October 20, 2015.
Residential Refrigerator UES Measure Update Regional Technical Forum April 16, 2013.
Idaho and Montana Residential Single Family New Construction Measures Mohit Singh-Chhabra Regional Technical Forum October 20 th, 2015.
ENERGY STAR Commercial Refrigerators and Freezers Regional Technical Forum January 21 st, 2016 Mohit Singh-Chhabra.
RTF Management Update Jennifer Anziano Regional Technical Forum June 16, 2015.
1 Summary of Reviews: Workpapers Approved by the California Technical Forum Part 2 Meeting: California Technical Forum January 28, 2016 Jeff Hirsch/Kevin.
Guidelines Overview Michael Baker January 20, 2016.
1 Analysis of Cost and Savings Values for Revised Energy Star Dishwasher Specifications June 6, 2006 Revised August 8, 2006 Revised Again January 23, 2007.
Residential Single Family Clothes Washer UES Measure Update Regional Technical Forum September 16, 2014.
Exterior LED Area Lights
RTF Management Update Jennifer Anziano Regional Technical Forum March 17, 2015.
Commercial Efficient Tank Water Heater UES Measure Update Regional Technical Forum December 17, 2013.
RTF Management Updates Jennifer Light Regional Technical Forum February 17, 2016.
Heat Pump Water Heaters: Interior, Ducted Installations Presentation to the Regional Technical Forum December 13, 2011 Ben Larson, Ecotope
Ductless Heat Pumps (DHP) in Single Family Homes with Zonal Electric Heat UES Measure Update Regional Technical Forum June 17, 2014.
Research Strategy: Residential Ductless Heat Pumps Research and Evaluation Subcommittee Christian Douglass and Josh Rushton January 8, 2016.
Proven UES: Residential Dishwasher Proposal to Deactivate Jennifer Anziano Regional Technical Forum November 10, 2015.
Manufactured Homes: Heat Pump Related Measures Regional Technical Forum Presentation August 18 th, 2015.
Presentation transcript:

Residential Clothes Washers and Dryers Technical Subcommittee Ryan Firestone & Christian Douglass Regional Technical Forum March 10, PM

Presentation Outline Today’s Objective: Guidance on Clothes Washer measure development, guidance on developing a Clothes Dryer research plan Interaction between Washer and Dryer measures Updates to Clothes Washer measure Developing a Clothes Dryer measure 2

Overview RTF Clothes Washer UES measure is due for an update – Sunset date June 2015 – New federal standard, and ENERGY STAR and CEE specifications effective March 7, 2015 – New market data (NEEA) – New field data on washers and dryers (NEEA) ENERGY STAR has its first Dryer specification (v.1.0), effective January 1, 2015 – ENERGY STAR resistance and heat pump based dryers are available – NEEA is conducting research on dryers to support an RTF Dryer UES measure There is a significant interaction between Washer and Dryer measures – Much of the Washer savings come from reductions in drying energy required after washing (higher spin) – Dryer savings are dependent on the moisture content of incoming clothes 3

Washer / Dryer Interaction 4

Dryer energy consumption is determined by – Amount of moisture to be removed from clothing – Energy efficiency of removing moisture from clothing 5 moisture (lbs) 1 / dryer efficiency (kWh/lb) Washer EE Dryer EE dryer energy (kWh)

Washer/Dryer Interaction 6 moisture (lbs) 1 / dryer efficiency (kWh/lb) dryer energy (kWh) Baseline Washer Baseline Dryer moisture (lbs) 1 / dryer efficiency (kWh/lb) EE Washer EE Dryer dryer energy (kWh) Baseline Washer EE Dryer moisture (lbs) 1 / dryer efficiency (kWh/lb) dryer energy (kWh) savings moisture (lbs) 1 / dryer efficiency (kWh/lb) EE Washer Baseline Dryer dryer energy (kWh) savings Washer savings Dryer savings ?

Washer/Dryer Interaction 7 moisture (lbs) 1 / dryer efficiency (kWh/lb) EE Washer EE Dryer dryer energy (kWh) Washer savings Dryer savings ? How to deal with these savings? – Measure identifiers Would require washer specs for Dryer measure, and dryer specs for Washer measure – Distribute across both measures E.g., Option 3 Guidelines call for considering all cost effective measures in “full measure package” Method would not handle Washer and Dryer tiers – We’d need to simplify to a single EE level for the analysis – Assume order of measures CAT/Staff propose to assume EE washer goes in first or at same time as EE dryer – ENERGY STAR (2015 spec) penetration of Washers was already ~70% in 2014 – Significantly EE Dryers (i.e., heat pump) are an emerging technology in U.S. markets – Is there interest in combined washer/dryer measures?

Updates to Residential Clothes Washers Measures 8

Remaining Moisture Content NEEA Washer/Dryer field study found that real-world clothing retains moisture more than DOE test cloth – Clothing coming out of washer are wetter than test clothes. Average rated remaining moisture content (RMC) in CEC DB: 36% Field study average: 71% – More dryer energy is required to remove a pound of moisture from clothing than test clothes (higher kWh/lb moisture) DOE Washer test procedure assumes 0.5 kWh/lb Field study average 0.62 kWh/lb 9

Remaining Moisture Content This has a huge impact on estimated drying energy 10

Market Share NEEA sales data from 2014 suggests very high penetration of ENERGY STAR 7.0 qualifying washers – This version of the specification effective March 7, 2015 Final numbers not yet available, but preliminary analysis is ~70% of combined top- and front- loading – Current RTF measure assumes 54%, based on 2013 sales and ENERGY STAR v6.1 11

Measure Grouping 12 Use a combined Top/Front load baseline (as in current UES measure)? If so, ENERGY STAR top loader is less efficient than the baseline – Exclude ENERGY STAR top loader? Note: CEE Tier 1 top loaders are scarce, Tier 2 / 3 top loaders aren’t available

Developing a Clothes Dryer Measure 13

Residential Clothes Dryers Federal standard: – New standard effective January 1, 2015 ENERGY STAR v1.0 – Effective January 1, 2015 Heat Pump (HP) Dryers introduced to U.S. market in Q

Residential Clothes Dryers Energy efficiency metrics – Federal standards D (Energy Factor (EF))– from previous standard. Pounds of clothes dried per kWh at highest temperature, 66% ΔRMC, assumed impact of auto- termination, no cool down D1 (Combined Energy Factor (CEF) – current standard. Pounds of clothes dried per kWh at highest temperature, 53.5% ΔRMC, assumed impact of auto- termination, no cool down Optional D2 (CEF) – current standard. Pounds of clothes dried per kWh at highest temperature, 55.5% ΔRMC, tested with auto-termination and cool- down – required for ENERGY STAR – NEEA proposal UCEF (lab testing) – Average of 5 modes (D2 plus 4 with more representative test cloth). Annual energy and frequency of modes aligns with field study. – Technical working group decided not to weight the modes differently. Field testing – estimated annual kWh and average pounds cloth/kWh 15

Residential Clothes Dryers NEEA Proposed Tiers – Standard – dryers that satisfy the federal standard by don’t qualify for ENERGY STAR – 1 – ENERGY STAR qualifying, probably not heat pump – 2 – today’s hybrid heat pump (LG, Whirlpool and Kenmore) – 3 – likely hybrid heat pump limit – 4 – pure heat pump dryer (e.g., Blomberg) 16

Available Data CEC Database – Products registered for sale in CA Washer performance metrics: IMEF, IWF, RMC Add date NEEA Washer/Dryer field study – Metered energy consumption, log book of clothing weights and machine settings. NEEA / PG&E lab study – Lab testing to determine D2, UCEF – Estimated market share per unit to estimate market average performance – Durango factor – laboratory at 6,500 ft. Unquantified impact on CEF, UCEF (likely improves metric a few percent) – Durango lab has since closed Ongoing NEEA lab and field testing of HP Dryers – NEEA will certify Tier 2 / 3 / 4 dryers for now 17

Tier 1 Dryers No clear correlation between D1 and D2 NEEA investigating D2 / UCEF relationship – 9 Standard dryers – 2 Tier 1 dryers Should the RTF pursue a Tier 1 Dryers measure? – Would likely require Tier 1 lab testing 18

Current Data 19 Energy Consumption Metric Data Source What kind? How many? D EFD1 CEFD2 CEFUCEFField CEC DB/Other product DBs Standard X Tier 1, 2 X 2011 DOEXX NEEA Washer/Dryer Field Study ~46x Standard (some Tier 1?) X (field) X (field) X Baseline Dryer Study 9x Standard X (Durango) 2x Tier 1 HP Dryer testing Tier 2,3,4 XXX

What the RTF needs A reliable metric of real-world energy use of dryers – UCEF is a good candidate, might be adjusted based on field test findings – Need confidence that UCEF values from lab(s) are comparable Significant samples of machines in all performance tiers tested to this metric – RTF needs confidence the samples are representative of the tier – CEF and UCEF for each tier are averages of representative products Current Practice baseline performance level – If not using DOE metric, need a means of estimating market share of sampled machines – Current Practice Baseline CEF and UCEF are the weighted averages of all tiers. Weighted by current market share 20

Questions for Subcommittee and RTF Is UCEF a sufficient metric for estimating energy consumption Is the Durango lab testing sufficient for estimating baseline UCEF? – If so, should the UCEF be adjusted for altitude? – Is there sufficient data to estimate Tier 1 consumption and savings? If existing data is not sufficient for a proven measure, what does research need to provide? 21

Next Steps for CAT/Staff Update Washer workbook and create Dryer workbook. Draft Preliminary Research Plan for dryers – Improve certainty of UCEF for baseline? Tier 1? – Establish UCEF for Tier 2/3/4 – Consider calibrating UCEF mode weights to field results for all Tiers 22