Optical Density and Brightness

Slides:



Advertisements
Similar presentations
PROCESSOR QA.
Advertisements

Producing an X-ray Exposure
DIGITAL RADIOGRAPHY.
Film and Sensitometry The science of measuring an emulsions reaction (sensitivity) to light is called sensitometry The Characteristic Curve The graph that.
Comparison of Film v. Digital Image Display. Process of data capture All image recording systems rely on differential absorption within the patient to.
Technique Guidance Systems
Chapter 11 Prime Factors.
Grey Level Enhancement Contrast stretching Linear mapping Non-linear mapping Efficient implementation of mapping algorithms Design of classes to support.
The Field of Digital Radiography
Copyright © 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins CHAPTER 15 Creating the Digital Image.
Primary Exposure Factors IV
IMAGE FORMATION  Introduction  The Invisible and Visible Image  Image Characteristics.
Radiographic Quality Chapter 5.
Digital Radiography.
Film Screen Q & A Robert Metzger, Ph.D.. RAPHEX General Question 2001 D10: Flood replenishment of a processor involves all of the following except: A.
RAD 354 Chapt. 28 The Digital Image Spatial resolution Contrast resolution Contrast-detail curve Pt. dose considerations.
Control of Scatter Radiation Beam Restricting Devices
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University Lecture 6 Basic physical principles of.
Analyzing the Image Density. Density Overall blackening of the image.
X-ray Beam Composition and Collimation
Prime Exposure Factors II By Professor Stelmark. Primary Factors The primary exposure technique factors the radiographer selects on the control panel.
1 DIGITAL RADIOGRAPHY. 2 Digital Radiography A “filmless” imaging system introduced in 1987 Digital radiography uses an electronic sensor, instead of.
X-ray radiography Seminar The "geometrical" unsharpness of X-ray images is limited by finite dimension of the source, i.e. the window on.
Chapter 4: Image Enhancement
Film Processing Q & A Robert L. Metzger, Ph.D.. RAPHEX 2001 Diagnostic Question D9 The imaging System which is best for visualizing small high contrast.
CS443: Digital Imaging and Multimedia Point Operations on Digital Images Spring 2008 Ahmed Elgammal Dept. of Computer Science Rutgers University Spring.
What is color for?.
Image Enhancement.
Sensitometry Describing photographic performance.
Digital Radiography Chapter 22. History of Digital Radiography Slower process of conversion because no pressing need to convert to digital radiography.
CR Image Acquisition By Professor Stelmark.
…….CT Physics - Continued V.G.WimalasenaPrincipal School of radiography.
Digital Image Characteristic
Resident Physics Lectures Christensen, Chapter 6Filters George David Associate Professor Department of Radiology Medical College of Georgia.
Control of Scatter Radiation
Quality Control.
Resident Physics Lectures
Image Quality Radiographic Resolution.
Chapter 21 Film Sensitometry. Copyright © 2006 by Thomson Delmar Learning. ALL RIGHTS RESERVED.2 Objectives Calculate speed points, speed exposure points.
Exposure Factors or Prime Factors
Digital Image Processing Lecture 3: Image Display & Enhancement March 2, 2005 Prof. Charlene Tsai.
Preparing Variable kVp Technique Charts By Prof. Stelmark.
Things they never tell you when the equipment is installed REV 11/2008
B ASIC P HYSICS OF D IGITAL R ADIOGRAPHY By : Maisa Alhassoun
PRINCIPLES OF TECHNIQUE AND EXPOSURE
How digital cameras work The Exposure The big difference between traditional film cameras and digital cameras is how they capture the image. Instead of.
Digital imaging By : Alanoud Al Saleh. History: It started in 1960 by the National Aeronautics and Space Administration (NASA). The technology of digital.
Sensitometry By Prof. Stelmark. The study of the relationship between the intensity of exposure of the film and the blackness after processing is called.
Radiographic Quality Visibility and Sharpness
Sounds of Old Technology IB Assessment Statements Topic 14.2., Data Capture and Digital Imaging Using Charge-Coupled Devices (CCDs) Define capacitance.
Radiographic Equipment
Film Optical Density Spectral Matching & sensitometry.
02-Gray Scale Control TTF. A TTF tells us how an imaging device relates the gray level of the input to the gray level of the output. P L Luminance, L.
Digital imaging By : Alanoud Al Saleh. History: It started in 1960 by the National Aeronautics and Space Administration (NASA). The technology of digital.
More digital reading explaining LUT RT 244 Perry Sprawls, Ph.D. Professor Emeritus Department of Radiology Emory University School of.
Image Display. But first a review Remember the 3 main steps 1. Data Acquisition 2. Image Reconstruction 3. Image Display.
More digital 244 wk 12 Perry Sprawls, Ph.D. Professor Emeritus Department of Radiology Emory University School of Medicine Atlanta, GA,
By Prof. Stelmark. Digital Imaging In digital imaging, the latent image is stored as digital data and must be processed by the computer for viewing on.
DIGITAL RADIOGRAPHY.
Tube Exposure Factors Math Technique Contrast and Density
Sergeo Guilbaud School of Radiologic Sciences
Exposure Factors or Prime Factors
{ Digital Image Processing By Professor Stelmark.
Computed Radiography By Prof. Stelmark.
Technique Guidance Systems By Prof. Stelmark. Anatomic Programming Anatomic programming, or anatomically programmed radiography (APR), refers to a radiographic.
Chapters 21 & 22.
כיצד נרכשת התמונה בסרט הרנטגני?
Represents inherent density of the film base, plus expected fog.
Grey Level Enhancement
Histogram The histogram of an image is a plot of the gray _levels values versus the number of pixels at that value. A histogram appears as a graph with.
Presentation transcript:

Optical Density and Brightness By Prof. Stelmark

DENSITOMETER A densitometer is a device used to numerically determine the amount of blackness on the film after processing (i.e., it measures radiographic density). This device is constructed to emit a constant intensity of light (incident) onto an area of film and then measure the amount of light transmitted through the film. The densitometer determines the amount of light transmitted and calculates a measurement known as optical density (OD).

A sensitometer is designed to produce consistent step-wedge densities

Optical Density Optical density is a numeric calculation that compares the amount of light transmitted through an area of radiographic film to the amount of light originally striking (incident) the film.

Percentage of Light Transmitted (It /Io ×100) Fraction of Light Transmitted (It /Io) Optical Density (log Io/It) 100 1/1 50 1/2 0.3 25 1/4 0.6 12.5 1/8 0.9 10 1/10 1 5 1/20 1.3 2.5 1/40 1.6 1.25 1/80 1.9 1/100 2 0.5 1/200 2.3 0.125 1/800 2.9 0.1 1/1000 3 0.05 1/2000 3.3 3.5 0.01 1/10000 4

Because the range of radiographic densities is large, the calculation of radiographic densities is compressed into a logarithmic scale A film that allows 100% of the original incident light to be transmitted has a logarithmic value of 0. A film that allows only 1% of the original incident light through has a logarithmic value of 2.0. This logarithmic value of light transmittance is termed optical density.

 Io represents the amount of original light incident on the film  It represents the amount of transmitted light

Light Transmittance and Optical Density As the percentage of light transmitted decreases, the optical density increases; as the percentage of light transmitted increases, the optical density decreases. Notice the relationship between light transmittance and optical density. When 100% of the light is transmitted, the optical density equals 0.0. When 50% of the light is transmitted, the optical density is equal to 0.3, and when 25% of the light is transmitted, the optical density equals 0.6. When a logarithmic scale base 10 is used, every 0.3 change in optical density corresponds to a change in the percentage of light transmitted by a factor of 2 (log10 of 2=0.3).

Optical Density = Net Density + (B+F) Optical densities can range from 0.0 to 4.0 OD. Because most radiographic film has a tint added to its base and processing adds a slight amount of fog, the lowest amount of optical density is usually between 0.10 and 0.20 OD. This minimum amount of density on the radiographic film is termed the base plus fog (B+F). Net Density (ND) equals optical density minus base plus fog. Optical Density = Net Density + (B+F) Net Density = Optical Density – (B+F)

DIAGNOSTIC RANGE The useful range of optical densities is between 0.25 and 2.5 OD. However, the diagnostic range of optical densities for general radiography usually falls between 0.5 and 2.0 OD. This desired range of optical densities is found between the extreme low and high densities produced on the film.

In CR, the exposure indicator value represents the exposure level to the imaging plate, and the values are vendor specific. Fuji and Konica use sensitivity (S) numbers, and the value is inversely related to the exposure to the plate. A 200 S number is equal to 1 mR of exposure to the plate. If the S number increases from 200 to 400, this would indicate a decrease in exposure to the IR by half. Conversely, a decrease in the S number from 200 to 100 would indicate an increase in exposure to the IR by a factor of 2, or doubling of the exposure.

Carestream (Kodak) uses exposure index (EI) numbers; the value is directly related to the exposure to the plate, and the changes are logarithmic expressions. For example, a change in EI from 2000 to 2300, a difference of 300, is equal to a factor of 2 and represents twice as much exposure to the plate.

Agfa uses log median (lgM) numbers; the value is directly related to exposure to the plate, and changes are also logarithmic expressions. For example, a change in lgM from 2.5 to 2.8, a change of 0.3, is equal to a factor of 2 and represents twice as much exposure to the IR

Brightness Because the image is composed of numeric data, the brightness level displayed on the computer monitor can be easily altered to visualize the range of anatomic structures recorded. This adjustment is accomplished using the windowing function. The window level (or center) sets the midpoint of the range of brightness visible in the image. Changing the window level on the display monitor allows the image brightness to be increased or decreased throughout the entire range. When the range of brightness displayed is less than the maximum, the processed image presents only a subset of the total information contained within the computer.

Assume that pixel values from 0 to 2048 are used to represent the full range of digital image brightness levels. A high pixel value could represent a volume of tissue that attenuated fewer x-ray photons and is displayed as a decreased brightness level. Therefore, a low pixel value represents a volume of tissue that attenuates more x-ray photons and is displayed as increased brightness.

Moving the window level up to a high pixel value increases visibility of the darker anatomic regions (e.g., lung fields) by increasing overall brightness on the display monitor. Conversely, to visualize better an anatomic region represented by a low pixel value, one would decrease the window level to decrease the brightness on the display monitor.

A direct relationship exists between window level and image brightness on the display monitor. Increasing the window level increases the image brightness; decreasing the window level decreases the image brightness.