Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Chapter 5: Analytic Techniques By Julia C. Drees, Matthew S. Petrie, Alan H.B. Wu.

Slides:



Advertisements
Similar presentations
OFFLINE COMPOSITION MEASURING SENSORS
Advertisements

BatteriesBatteries How Batteries Work. Three Main Components of Batteries Negative terminal (anode): an electrode made of a metal such as zinc that accumulates.
MLAB 2401: C LINICAL C HEMISTRY K ERI B ROPHY -M ARTINEZ Designs in Instrumentation Electrochemistry.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Electrochemical Cells
Potentiometry. pH is a Unit of Measurement  pH = Power of Hydrogen (H + )  Defined as the Negative Logarithm of Hydrogen Ion Activity  pH = log (1/H.
Galvanic Cells What will happen if a piece of Zn metal is immersed in a CuSO 4 solution? A spontaneous redox reaction occurs: Zn (s) + Cu 2 + (aq) Zn 2.
ANALYTIC METHODS II. PART Jana Švarcová.  Chromatography  Electrophoresis  Potentiometry  Titration  Spectrophotometry.
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
Flame photometry.
Molecular Fluorescence Spectroscopy
MLAB 2401: Clinical Chemistry Keri Brophy-Martinez Analytical Techniques and Instrumentation Electromagnetic Radiation & Spectrophotometry 1.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Clinical Chemistry Chapter 4
Instrumental Chemistry
Chapter 19 Electrochemistry
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Biochemical instrumental analysis-2
Introduction to Instrumental Analysis - Spectrophotometry
What Are Some Types of Spectroscopy ?
MLAB 2401: Clinical Chemistry Keri Brophy-Martinez Electrophoresis.
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Chapter 17 Electrochemistry 1. Voltaic Cells In spontaneous reduction-oxidation reactions, electrons are transferred and energy is released. The energy.
Atomic Absorption Spectrophotometer
Principles of instrumentation Prepared by: Ibtisam H. AlAswad Reham S. Hammad.
Year 12 Chemistry Unit 3 – AOS 1 Chemical Analysis.
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
Fluorometric determination of riboflavin
Fluorometric determination of riboflavin. Introduction.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Chemiluminescence. Luminescence Definition Luminescence is emission of light by a substance not resulting from heat Types of luminescence Fluorescence.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 19 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Spectrophotometry.
Chapter 6 An Introduction to Spectrometric Methods Spectrometric methods are a large group of analytical methods that are based on atomic and molecular.
Electrochemistry.
Molecular Luminescence Spectroscopy
Fluorescence is the emission of light by a substance that has absorbed light or other electromagnetic radiation of a different wavelength. George Gabriel.
Introduction to Spectrochemical Methods
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Colorimeters or photometers
Spectrophotometer.
Biochemical instrumental analysis - 8 Dr. Maha Al-Sedik 2015 CLS 332.
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
Photometry.
Fluorometric determination of riboflavin
ELECTROCHEMICAL CELLS. ELECTROCHEMISTRY The reason Redox reactions are so important is because they involve an exchange of electrons If we can find a.
Atomic Absorption Spectroscopy.  Qualitative test for metals in solution  Can also be used for coloured lights  This emission of light is called an.
Welcome To my presentation.
Lab Tools of Forensic Scientists. Detection Presumptive tests ◦ Give idea as to what probably is in a sample/what definitely is not in a sample  Ex:
Laserlaser. Laser printer Laser pointer Laser: everywhere in your life.
Molecular Fluorescence Spectroscopy
Principles of instrumentation. Photometry - Photometry means “the measurement of light” If a substance can be converted to a soluble, colored material,
ELECTRO-ANALYTICAL TECHNIQUES   POTENTIOMETRIC TECHNIQUES Principle Electrochemical techniques/ Electrochemical methods are generally used for determination.
Flame Emission Spectrometry
Estimation of analyte concentration on the basis of light absorption
Chapter 5: Analytic Techniques
Colorimeters or photometers
Spectrophotometer Dr . S. Jayakumar.
Measurement of Analytes
Colorimeters OR photometers
SPECTROPHOTOMETRY Applied Chemistry.
LASERS By Swapan Das.
Kap.11 Clinical laboratory
Electrophoresis: Movement of a solid phase with respect to a liquid (buffer) Sample is applied to the medium and under the effect of electric field, group.
Kap.11 Clinical laboratory
Spectrophotometry A method to determine concentration of a species exploiting the absorption of EMR.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Batteries How Batteries Work.
Presentation transcript:

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Chapter 5: Analytic Techniques By Julia C. Drees, Matthew S. Petrie, Alan H.B. Wu

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Spectrophotometry and Photometry Photometric instruments measure light intensity without consideration of wavelength. Most instruments use filters (photometers), prisms, or gratings (spectrometers) to select (isolate) a narrow range of incident wavelength. Beer’s Law: Concentration of a substance is directly proportional to right amount of light absorbed or inversely proportional to logarithm of transmitted light. Spectrophotometric Instruments: measure light transmitted by a solution to determine concentration of light-absorbing substance in solution

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Spectrophotometry and Photometry (cont’d) Components of a Spectrophotometer –Light source –Monochromators –Sample cell –Photodetectors Spectrophotometer Quality Assurance –Wavelength accuracy –Stray light –Linearity

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Spectrophotometry and Photometry (cont’d) Single-beam spectrophotometer

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Spectrophotometry and Photometry (cont’d) Atomic Absorption Spectrophotometer –Measures concentration by detecting absorption of electromagnetic radiation by atoms rather than by molecules –Sensitive, precise –Routinely used to measure concentration of trace metals that are not easily excited Flame Photometry –Measures light emitted by excited atoms –Was used to determine concentration of Na, K, or Li –No longer routinely used; replaced by ion-selective electrodes

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Spectrophotometry and Photometry (cont’d) Fluorometry –Basic instrumentation Filter fluorometers measure concentrations of solutions that contain fluorescing molecules. Source emits short-wavelength high-energy excitation light. Mechanical attenuator controls light intensity. –Advantages and disadvantage of fluorometry Advantages: greater specificity and sensitivity Disadvantage: very sensitive to environmental changes

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Spectrophotometry and Photometry (cont’d) Basic filter fluorometer

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Spectrophotometry and Photometry (cont’d) Chemiluminescence –Part of chemical energy generated produces excited intermediates that decay to a ground state with emission of photons. –Unlike fluorescence, no excitation radiation or monochromators are required. –Oxidation reactions of luminol, acridinium esters, & dioxetanes Turbidity and Nephelometry –Turbidity measures concentration of particulate matter in sample. –Nephelometry: similar to turbidity, except different angle of measurement

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Spectrophotometry and Photometry (cont’d) Laser Applications –LASER: Light Amplification by Stimulated Emission of Radiation –Based on interaction of radiant energy and suitably excited atoms or molecules –Laser light is polarized and coherent and has narrow spectral width and small cross-section area with low divergence. –Can serve as source of incident energy in spectrometer or nephelometer –Laser spectrometry can be used for determination of structure, identification of samples, and diagnosis.

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Electrochemistry Galvanic and Electrolytic Cells –Galvanic cells Spontaneous flow of electrons from electrode with lower electron affinity Electrons pass through external meter to cathode, liberating OH - ions; reaction continues until cell is dead. –Electrolytic cells: Current is forced to flow through dead cell by applying external electromotive force E. Half-Cells –Two reactions must be coupled and one reaction compared with other to measure electrochemical activity of half-cell.

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Electrochemistry (cont’d) Ion-Selective Electrodes (ISE): designed to be sensitive toward individual ions pH Electrodes –Indicator electrode –Reference electrode –Liquid junctions –Readout meter –Nernst equation –Calibration –pH combination electrode

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Electrochemistry (cont’d) Gas-Sensing Electrodes –Designed to detect specific gases in solutions –Separated from solution by thin, gas-permeable membrane Enzyme Electrodes –An ISE covered by immobilized enzymes that can catalyze a specific chemical reaction Coulometric Chloridometers and Anodic Stripping Voltammetry –Chloride ISEs have largely replaced coulometric titrations. –Anodic stripping voltammetry was widely used for analysis of lead.

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Electrophoresis Migration of charged solutes/particles in an electrical field Five components: driving force, support medium, buffer, sample, detecting system Procedure –Sample is soaked in hydrated support for 5 minutes. –Support is put into electrophoresis chamber filled with buffer. –Constant voltage or current is applied for a specific time. –Support is removed and placed in fixative or rapidly dried. –Zones are stained with appropriate dye.

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Electrophoresis (cont’d) Support Materials: cellulose acetate, agarose gel, polyacrylamide gel, starch gel Treatment and Application of Sample Detection and Quantitation Electroendosmosis Isoelectric Focusing Capillary Electrophoresis Two-dimensional Electrophoresis

Copyright © 2014 Wolters Kluwer Health | Lippincott Williams & Wilkins Osmometry Measures concentration of solute particles in a solution Freezing-point osmometer –Sample in a small tube is lowered into a chamber with cold refrigerant circulating from cooling unit. –Thermistor is immersed in sample. –Wire is used to stir sample until it is cooled to several degrees below its freezing point.