A Wireless Implantable Microsystem for Continuous Blood Glucose Monitoring Currently 200M diabetic people around the world (~ 21M in U.S. in 2002).  Expectation.

Slides:



Advertisements
Similar presentations
Getting and Using Nutrients
Advertisements

EEE 529 Microsystems Amperometric Biosensors
On-line Glucose Measurement in Disposable Bioreactors Michael Hartlep and Wolfgang Künnecke INTRODUCTION The use of disposables in biopharmaceutical processes.
Novel Approach to Lactate Sensing Diabetes Pre-screening Tool Christine Zhang, Stephanie Wu, Joseph Sun, Wern Ong, Toby Li.
The Detection of Hydrogen Peroxide and Glucose for the Electrode Modified with Ferrocene Yi-Sheng Wang ( 汪乙生 ), Ting-Li Lin ( 林庭立 ), Hau Lin ( 林浩 ) Department.
Embedded Wireless Sensors Tony Arous Vincent Yu. Introduction  Sensors help to easily keep track of various information PeoplePeople ProductsProducts.
BLOOD GLUCOSE MONITORS By: Matt Colletti. What is a blood glucose monitor? It is a device that measures the level of glucose in a blood sample Useful.
EEC 693/793 Wireless Sensor Networks A Short Name of your Paper’s Title Student Name.
Responsive Drug Delivery System
The Mole & Chemical Formulas A chemical formula represents the ratio of atoms that always exists for that compound Example: Water – H 2 O Always 2 H atoms.
Sensors and Their Uses in Hospitals
Electrochemical Glucometers
Industrial and Medical Use of Enzymes. Biosensors.
Electroanalysis measure the variation of an electrical parameter (potential, current, charge, conductivity) and relate this to a chemical parameter (the.
Biosensors NNIN Document: NNIN-1245 Rev: 03/2012 National Nanotechnology Infrastructure Network Copyright Georgia Institute of.
Concentration & Consumer Products LG: I can perform concentration calculations involving units commonly used in consumer products.
Topic 6 – Wireless Technology and handheld devices 1)TechMed scenario covers The uses of wireless technologies and handheld devices In the scenario: “Some.
Professor: Tsung – Fu Chien Nguyen Trong Tuyen Master Student Department of Electrical Engineering SOUTHERN TAIWAN UNIVERSITY Wireless Implantable Electronic.
IntroOH-1 CSE 5810 Wireless Body Sensor Networks (WBSN) in Healthcare Aljoharah A. Algwaiz Computer Science & Engineering Department The University of.
Topic 5 – Sensors and Monitoring Systems 1)TechMed scenario covers Sensors and their uses in hospitals In the scenario: “A patient-monitoring system is.
September, 2006Doc: IEEE BAN Zhen, Li, and Kohno Slide1 Implanted applications of IG-BAN Bin Zhen, Huan-Bang Li and Ryuji Kohno National.
Doc.: IEEE q Submission ETRI July 2013 Slide 1 Project: IEEE P Working Group for Wireless Personal Area Networks (WPANs) Submission.
Wireless Biosensor Monitoring System Danielle Morton*, Niloufar Pourian*, Prof. Luke Theogarajan* * Electrical and Computer Engineering Department Abstract.
Biosensors NNIN Document: NNIN-1245 Rev: 03/2012 National Nanotechnology Infrastructure Network Copyright Georgia Institute of.
A Seminar presentation On PAPER BATTERY.
Preparation of the Carbon Paste Electrode Modified with Ferrocene and Its Applications to Detection of Hydrogen Peroxide and Glucose Yi-Sheng Wang ( 汪乙生.
For: Communication Technology 2201 By: Chris Murphy.
Doc.: IEEE Submission May 2008 Sung Dong Lee, InfopiaSlide 1 Project: IEEE P Working Group for Wireless Personal Area Networks.
Question # 1 For $100 15$1,000,000 14$500,000 13$250,000 12$125,000 11$64,000 10$32,000 9$16,000 8$8,000 7$4,000 6$2,000 5$1,000 4$500 3$300 2$200 1$100.
1 Eric McAdams Sensor Technology + Devices Ltd Belfast Northern Ireland Wireless Non-Invasive Vital Signs Monitoring.
Biomedical Sensors Dr. James A. Smith. What’s Important? Accuracy Operational Range Response Time Sensitivity Resolution Reproducibility.
BIOmem Glucose sensor Une belle histoire…. - Concept -- Clark (1956) - Concept -- Clark (1956) - Enzyme electrode -- Lyons and Clark (1962) - Enzyme.
The Optimum Operating Conditions for Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with Ferrocene Pao-Tsai Kuo ( 郭寶財 ), Chung-Min.
By Dominic Lanni. Part One Introduction  What are biosensors?  A device that uses a living organism or biological molecule to detect things  Usually.
Warm Up Predict the products and balance the following equations: a.KI + Br 2 → b.H 2 SO 4 + KOH →
An Analysis of Variance of Detection of Hydrogen Peroxide for Carbon Paste Electrode Modified with Copper Hexacyanoferrate Chia-Cheng Hsiao ( 蕭佳政 ), Chih-Ying.
Morgan Briggs, Knoxville Catholic High School
PTT 202 ORGANIC CHEMISTRY FOR BIOTECHNOLOGY Lecture 4: Electroanalytical Methods Zulkarnain Mohamed Idris Semester /2014.
The Operating Conditions for the Sensitivity of Detection of Hydrogen Peroxide for the Electrode Modified with Copper Hexacyanoferrate Chia-Cheng Hsiao(
CONTACT LENS THAT INFORMS ABOUT THE BLOOD GLUCOSE LEVELS M.Abhinandana M.Pharm Quality Assurance.
Application of the Screen Printed Planar Electrode Modified with Ruthenium Hexacyanoferrate to Glucose Biosensor Kuo-Hsiang Liao( 廖國翔 ), Chung-Min Lien(
By Dominic Lanni. Part One Introduction  What are biosensors?  A device that uses a living organism or biological molecule to detect things  Usually.
Diabetes (Type 1) By Joseph Russo 416. What are Diabetes Diabetes happen when either too much sugar is in your system or insulin* is not being produced.
Surfaces and Electrochemistry
Copyright © 2008 Delmar Learning. All rights reserved. Unit 42 Endocrine System.
Should there be a sugary beverage tax in San Francisco? Position: YES PA 724 Group Policy Debate Fall 2014 Oriol Zales, Nicole Barcan, Kathleen Zierolf,
The pH on the Detection of Hydrogen Peroxide for Electrode Modified with Chromium Hexacyanoferrate Chen-Hsun Hu ( 胡真熏 ), Ting-Li Lin ( 林庭立 ), Hau Lin (
Lesson Starter 1.What is a catalyst? 2.What effect do catalysts have on the input energy required for a reaction to happen? 3.What is special about a catalyst.
Anup Pillai Dhanya Premkumar Nair.  Long-Term Implantable Blood Pressure Monitoring System  Wireless Battery less In VIVO Blood Pressure Sensing Micro.
A Study of Carbon Paste Electrode Modified with Platinum Particles and Ferrocene and Its Application to Glucose Biosensor Yi-Sheng Wang ( 汪乙生 ), Ting-Li.
Implantable Medical Devices Energy Supplying In Healthcare technology, during this decade, Scientific research has been focusing in the interaction between.
BIO BATTERY a fuel of next generation… Submitted By:- Abhinav Pathak 10EUDEC002.
ECE 477 – Team 5. »We are designing a wireless telemetry system that measures translational and angular accelerations experienced by athletes and stores.
The reading is 7.38 mm. The reading is 7.72 mm.
Bovine liver catalase bovine liver catalase is a common enzyme found in nearly all living organisms, where it functions to catalyze the decomposition of.
Increasing Annual Cost of Diabetes
Design and Fabrication
/ CHEMICAL CROSS TALK STUDIES ON A MICROPROBE ARRAY BASED CONTINUOUS GLUCOSE MONITORING SENSOR Sanjiv Sharmaa,
RESULTS AND DISCUSSION
WHMIS Workplace Hazardous Material Information System
The (Matthew Walker) Texas Rangers III Developing a Ventriculoperitoneal Shunt Failure Monitoring Approach for Pediatric Hydrocephalic Patients Oral Report.
© 2018 Global Market Insights, Inc. USA. All Rights Reserved What will be the size of Contact Lenses Market in 2017 to ?
BIO-NANOTECHNOLOGY Size: 1mm x 1mm x 5mm
BIO-NANOTECHNOLOGY Size: 1mm x 1mm x 5mm
By Raymond Adorno For Dr Peel Material Science
Hydrogen Fuel Cells.
All-in-one – cancer diagnosis, treatment and evaluation
Production of reactive oxygen species.
The proportion of patients confronted with a cardiovascular risk factor (CVRF) they were previously unaware of, referring to the instrument based tests.
The continuous line represents the sensor glucose values.
Presentation transcript:

A Wireless Implantable Microsystem for Continuous Blood Glucose Monitoring Currently 200M diabetic people around the world (~ 21M in U.S. in 2002).  Expectation for 2030: 370M Contribution to the death of millions of people.  225,000 people in U.S. in Monetary cost to the society: billions of dollars.  $130 billion in U.S. in Currently 200M diabetic people around the world (~ 21M in U.S. in 2002).  Expectation for 2030: 370M Contribution to the death of millions of people.  225,000 people in U.S. in Monetary cost to the society: billions of dollars.  $130 billion in U.S. in Continuous blood glucose monitoring can help to significantly (40 to 75%) reduce the symptoms of diabetes.

Problems of the Previous Works Using the conventional glucose biosensors.  Requirement for oxygen;  Degradation of the sensor due to the production of hydrogen peroxide (short life-time);  Interference from other chemical species. Using battery for powering the implant  Short life-time;  Hazard of leakage. Large Size  Instability of the sensing environment;  Difficulties in packaging. Using the conventional glucose biosensors.  Requirement for oxygen;  Degradation of the sensor due to the production of hydrogen peroxide (short life-time);  Interference from other chemical species. Using battery for powering the implant  Short life-time;  Hazard of leakage. Large Size  Instability of the sensing environment;  Difficulties in packaging.

A New Wireless Implantable Microsystem A new electrochemical glucose sensor. Passive telemetry for data and power transfer between the implant and the external reader. Small size (4  8  1 mm 3 ). A new electrochemical glucose sensor. Passive telemetry for data and power transfer between the implant and the external reader. Small size (4  8  1 mm 3 ).