Radiation Safety level 5 Frits Pleiter 02/07/2015radiation safety - level 51.

Slides:



Advertisements
Similar presentations
Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Detecting Ionising Radiation James Gray University RPA.
Advertisements

Radiation Detection ionization chambers (dosimeters, pulse chambers, particle track chambers) scintillation detectors semiconductor detectors photographic.
GM COUNTER.
Geiger-Muller detector and Ionization chamber
Dispersive property of a G-M tube HV - + In the proportional region a G-M tube has dispersive properties tube voltage.
Experimental Particle Physics PHYS6011 Joel Goldstein, RAL 1.Introduction & Accelerators 2.Particle Interactions and Detectors (1/2) 3.Collider Experiments.
Radiation Safety Course Radiation Monitoring Heath de la Giroday Dispensing Chemist Radiation Safety Officer.
Detecting and Measuring Ionizing Radiation -2
Radiation Detection & Measurements - 1
Radiation Detectors / Particle Detectors
Scintillators. When radiation interacts with certain types of materials, it produces flashes of light (scintillation) Materials that respond this way.
Tracking detectors/1 F.Riggi.
X-ray Astronomy Lee Yacobi Selected Topics in Astrophysics July 9.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Principles of Radiation Detection
Lesson 17 Detectors. Introduction When radiation interacts with matter, result is the production of energetic electrons. (Neutrons lead to secondary processes.
Detecting Cosmic Rays An inexpensive portable detector By: Danny Franke Quarknet 2004.
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
Scintillators.
High Energy Detection. High Energy Spectrum High energy EM radiation:  (nm)E (eV) Soft x-rays X-rays K Soft gamma rays M Hard gamma.
03/07/2015radiation safety - level 51 Radiation safety level 5 Frits Pleiter.
Main detector types Scintillation Detector Spectrum.
Instruments for Radiation Detection and Measurement
Photomultiplier Tube. What is it? Extremely sensitive detector of light in the ultraviolet, visible and near infrared Multiplies the signal produced by.
Gamma Spectroscopy HPT TVAN Technical Training
2: Radiation Measurements
Radiation Detection and Measurement II IRAD 2731.
Detectors The energy loss of particles in matter can be used detect and identify those particles. There are different types of “detectors”: - Gas-filled.
Principles of Radiation Detection
Chapter 6 Principles of Radiation Detection. Measurement of Radiation X-rays and electrons produced by radiation therapy treatment machines are measured.
DETECTION AND MEASUREMENT OF RADIOACTIVITY 1 NANIK DWI NURHAYATI,S.SI,M.SI.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
Properties of X-Rays Reference: “Elements of X-ray Diffraction”, 3nd Edition, B.D. Cullity, and S.R. Stock, Prentice Hall, NJ Chapter 1
Type of Material: Instrumentation Review
Photon detection Visible or near-visible wavelengths
CLRS 321 Nuclear Medicine Physics & Instrumentation I Part C: Semiconductors and Miscellaneous Scintillation Devices Unit II: Nuclear Medicine Measuring.
Tanja Horn, CUA PHYS 575/675 Modern Detectors Phys 575/675, Spring 2012 Tools of High Energy and Nuclear Physics Detection of Individual Elementary Particles.
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
Who is this?. Marie Curie Born 1867 Poland 1893 degree in physics, 1894 degree in mathematics Denied a place in Krakow University because she was.
FISICA AMBIENTALE 1 Radioattività: misure 1 Lezioni Marie Curie.
Monday, Mar. 7, 2005PHYS 3446, Spring 2005 Jae Yu 1 PHYS 3446 – Lecture #12 Monday, Mar. 7, 2005 Dr. Jae Yu Particle Detection Ionization detectors MWPC.
SCINTILLATION COUNTER. PRINCIPLE When light radiations strike fluorescent material it produces flashes of light called scintillations. These are detected.
Instrumentation Review. Direct and Indirect Ionization Direct - Charge particles that strip away electrons from atoms Indirect - uncharged that have to.
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
Seeing the Subatomic Stephen Miller Saturday Morning Physics October 11, 2003.
Medical Image Analysis Interaction of Electromagnetic Radiation with Matter in Medical Imaging Figures come from the textbook: Medical Image Analysis,
Wednesday, Oct. 18, 2006PHYS 3446, Fall 2006 Jae Yu 1 PHYS 3446 – Lecture #12 Wednesday, Oct. 18, 2006 Dr. Jae Yu 1.Particle Detection Ionization Detectors.
Radiation detection and measurement
PHYSICS 225, 2 ND YEAR LAB NUCLEAR RADIATION DETECTORS G.F. West Thurs, Jan. 19.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Detection of Radiation Contents: Geiger tubes Photo-Multiplier tubes Cloud Chambers Solid State devices.
Chapter V Radiation Detectors.
3/2003 Rev 1 II.3.5 – slide 1 of 23 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Session II.3.5 Part IIQuantities.
Radiation detectors Ion chamber 2. Geiger Muller counter (GM).
Radiation Protection RTMR 284 CHAPTER 20 PART II.
PAN-2013: Radiation detectors
CLRS 321 Nuclear Medicine Physics & Instrumentation I
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
Gamma-Gamma Correlations in Na-22
Scintillation Counter
1 Principles of Radiation Detection Operational Radiological Safety Course U.S. Army Chemical Biological Radiological & Nuclear School Edwin R. Bradley.
Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Detecting Ionising Radiation James Gray University RPA.
Semiconductor Detectors
Radioactivity B. Sc. -III Feb Dr. Wagh G. S. M. Sc. M. Phil. Ph
Photomultiplier (PMT) Tubes
X-ray detectors single photon detectors
Detecting Ionising Radiation
PARTICLE DETECTORS I recently joined the IAEA.
PHYS 3446 – Lecture #16 Monday ,April 2, 2012 Dr. Brandt
Presentation transcript:

Radiation Safety level 5 Frits Pleiter 02/07/2015radiation safety - level 51

Contents  atomic and nuclear physics (1)  interaction with matter (3) o sources and x-ray equipment (2) o shielding (3) o detection (4) o radiobiology (6) objective risk of radiation (6) subjective risk acceptation (6)  quantities and units (5)  regulations (7) o practical health physics (8 - 10) o waste (11) 02/07/2015radiation safety - level 52

Detection  ionization detector  scintillation detector  photographic emulsion  electronic equipment 02/07/2015radiation safety - level 53

Detection ionization detector gas filled detector ionization chamber proportional counter Geiger-Müller counter air, natural gas, noble gas, V semiconductor detector germanium (  -radiation) silicon (  -radiation, x-ray radiation) V 02/07/2015radiation safety - level 54 anode wire cathode wall counting gas

Detection ionization 02/07/2015radiation safety - level 55 gas atoom positive ion negative elektron ionizing radiation cathode wall anode wire ionization energy = 34 eV

Detection gas amplification primary electrons are accelerated collide with gas atoms and produce secundary ions 02/07/2015radiation safety - level 56 secundary charge positive ion negative electron 1 primary charge 2 cathode wall anode wire ionizing radiation

Detection influence of anode voltage I.recombination II.ionization chamber III.proportional counter IV.incomplete proportionality V.Geiger-Müller counter VI.continuous gas discharge 02/07/2015radiation safety - level 57  -particle III III IV V VI  -particle

Detection proportional counter 02/07/2015radiation safety - level 58 proportional counter energy resolution at 6.4 keV is 17%

Detection Geiger-Müller counter simple construction and cheap anode field is shielded by positive ions which reduces gas amplification constant pulse height > 10 V dead time  > 0.1 ms  true count rate > measured count rate secundary electrons from cathode wall are accelerated and produce a new signal, etcetera to prevent this, a (multiatomic) quench gas is added 02/07/2015radiation safety - level 59

Detection examples of ionization detectors 02/07/2015radiation safety - level 510

Detection semiconductor detector ionization energy  3 eV pros high efficiency excelent energy resolution cons no gas amplification must be cooled to 80 K expensive 02/07/2015radiation safety - level 511

Detection semiconductor detector 02/07/2015radiation safety - level 512 Ge-detector energy resolution at 661 keV is 0.4%

Detection scintillation detector inorganic scintillator NaI, BaF 2, ZnS, BGO often contains a fluorescent additive, e.g. NaI(Tl) organic scintillator anthracene, stilbene, plastic, liquid often contains a fluorescent additive chemical and optical quenching thermoluminescence detector (TLD) CaF 2, LiF, Li 2 B 4 O 7 02/07/2015radiation safety - level 513

Detection photomultiplier tube interaction of  -photon with scintillator  light photons interaction of light photon with cathode  photo-electron photo-electron hits electrodes at each collision secundary electrons are liberated in NaI, about 500 eV per photo-electron is required 02/07/2015radiation safety - level 514 ionizing radiation light photocathode dynode photomultiplier tube electrons anode contact pins scintillation crystal

Detection scintillation detector 02/07/2015radiation safety - level 515 NaI detector energy resolution at 5.9 keV is 43.5% energy resolution at 662 keV is 7%

Detection thermoluminescence detector (TLD) interaction lifts an electron into a metastable state if TLD material is heated, electron returns to ground state during this proces infrared light is emitted 02/07/2015radiation safety - level 516 B A valence band conduction band ionizing radiation

Detection examples of scintillation detectors 02/07/2015radiation safety - level 517

Detection photographic emulsion film badge as personal dose registration tool completely replaced by TLD badge autoradiogram analytic tool in chemistry and biochemistry more and more replaced by semiconductor tools x-ray picture medical diagnostic tool more and more replaced by semiconductor devices nuclear emulsion detector for elementary particles in cosmic radiation replaced by equipment with volumes > 1000 m 3 02/07/2015radiation safety - level 518

Detection detector for elementary particles 02/07/2015radiation safety - level 519

Detection proper choice of detector which detector to choose depends largely on what has to be measured (and on the available amount of money) dose of dose rate contamination  -,  -,  -radiation identification of a nuclide in the last case, energies must be measured (spectroscopy) with the aid of a multichannel analyser nowadays hardly more than an interface card in the computer 02/07/2015radiation safety - level 520

Detection proper choice of detector dose rate meter reading in sievert per unit of time not suited for contamination measurements contamination monitor reading in number of counts per unit of time not suited for dose rate measurements 02/07/2015radiation safety - level 521

Detection proper choice of detector  -dose measured with Geiger-Müller counter signal provides no energy information photo-effect and Compton-effect create electrons in the tube wall electrons that escapes into the gas cause an electric pulse the larger E , the thicker the layer from which electrons can escape  N pulse  N   E   dose 02/07/2015radiation safety - level 522 gas

Detection proper choice of detector  -contamination ZnS with extremely thin window gas filled detector with extremely thin window liquid scintillation counter  -contamination gas filled detector with thin window Si-detector with thin window (no Ge since it is more sensitive to  -ray background) liquid scintillation counter 02/07/2015radiation safety - level 523

Detection proper choice of detector  -contamination NaI-detector gas filled detector with large area and low background Ge-detector Si-detector with thin window (especially for x-ray radiation) liquid scintillation counter (if E  < 50 keV) 02/07/2015radiation safety - level 524

Detection  -spectroscopy  photopeak at E   escape peak at E  - E X  Compton-edge after electron capture and internal conversion  x-ray peak at E X after pair formation outside detector  annihilation peak at 511 keV line width is due to statistics 02/07/2015radiation safety - level 525

Detection multichannel analyzer 02/07/2015radiation safety - level 526

Detection energy calibration 02/07/2015radiation safety - level 527

Detection efficiency calibration 02/07/2015radiation safety - level 528