JDSU Test Equipment Training In Support of AT&T Requirements

Slides:



Advertisements
Similar presentations
Module 3 Configuring Hardware on a Computer Running Windows XP Professional.
Advertisements

1 of 6 This document is for informational purposes only. MICROSOFT MAKES NO WARRANTIES, EXPRESS OR IMPLIED, IN THIS DOCUMENT. © 2006 Microsoft Corporation.
Department of Environmental Conservation 1 DATAMAX PRINTER SETUP MODULE 1.
LogTag Training January 2015
WORKING SMART Crystal M. Thomas Henrico County DSS (804) POSSESS Central Region Member October 31, 2007.
Microsoft PowerPoint 2013 An Overview.
Microsoft Excel 2013 An Overview. Environment Quick Access Toolbar Customizable toolbar for one-click shortcuts Tabs Backstage View Tools located outside.
DNR-322L & DNR-326.
Miscellaneous Windows 2000 Desktop Features Windows 2000 Intermediate.
Pursuit of Better testing Instrument Let's go in the grandway......
1 of 6 Parts of Your Notebook Below is a graphic overview of the different parts of a OneNote 2007 notebook. Microsoft ® OneNote ® 2007 notebooks are digital.
EPOCH 1000 File Management Data Logging and Reporting
TESTING MULTIMODE FIBER
Testing Optical Fiber Links
Best Practices for Ensuring Fiber Optic System Performance
6 th Annual Focus Users’ Conference Application Editor and Form Builder Presented by: Mike Morris.
Using Microsoft Outlook: Basics. Objectives Guided Tour of Outlook –Identification –Views Basics –Contacts –Folders –Web Access Q&A.
ADVANCED MICROSOFT POWERPOINT Lesson 6 – Creating Tables and Charts
Things to note... The Simple Cart is designed to give users an experience similar to other online shopping sites by separating the cart from the checkout.
DWR-113 FAQ’s 3G WiFi Router.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
Configuring the MagicInfo Pro Display
Page 1 © 2008 IDEAL INDUSTRIES IDEAL Micro OTDR Oktober 2008 Konstantin Hüdepohl.
Advanced SAGE Formative Adding Your Own Resources Using Common Assessments Creating Educator Groups.
© Commonwealth of Australia 2009 Using OneNote in the Classroom.
Chapter 2 Querying a Database MICROSOFT ACCESS 2010.
Screen Previews for Shopping Carts and Checkout Process 10.3 release October 05, 2010.
© 2008 The McGraw-Hill Companies, Inc. All rights reserved. WORD 2007 M I C R O S O F T ® THE PROFESSIONAL APPROACH S E R I E S Lesson 21 Fields and Forms.
© 2004 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice SISP Training Documentation Template.
New Features in Release 9.2 (July 27, 2009). 2 Release 9.2 New Features Updated Shopping Experience Home/Shop page Shop at the top search New Hosted Supplier.
1 OPOL Training (OrderPro Online) Prepared by Christina Van Metre Independent Educational Consultant CTO, Business Development Team © Training Version.
1. Chapter 25 Protecting and Preparing Documents.
VistA Imaging Capture via Scanning. October VistA Imaging Capture via Scanning The information in this documentation includes only new and updated.
Analog Discovery Arbitrary Function Generator for Windows 7 by Mr
Computing Fundamentals Module Lesson 3 — Changing Settings and Customizing the Desktop Computer Literacy BASICS.
CREATING TEMPLATES CREATING CUSTOM CHARACTERS IMPORTING BATCH DATA SAVING DATA & TEMPLATES CREATING SERIES DATA PRINTING THE DATA.
Training Guide for Inzalo SOP Users. This guide has been prepared to demonstrate the use of the Inzalo Intranet based SOP applications. The scope of this.
Mercury G3 Service Tool Training Overview When opening G3 you will start at this screen first import thing to look for is communication.
Word 2007 What’s New. Ribbon Interface Replaces toolbars and menus Contains tabs and grouped commands Each tab corresponds to task Related items grouped.
© 2008 The McGraw-Hill Companies, Inc. All rights reserved. WORD 2007 M I C R O S O F T ® THE PROFESSIONAL APPROACH S E R I E S Lesson 15 Advanced Tables.
Microsoft Access 2010 Chapter 10 Administering a Database System.
FIX Eye FIX Eye Getting started: The guide EPAM Systems B2BITS.
Access Forms and Queries. Entering Data in Your Table  You can add data to your table in Datasheet view, by typing in the columns and rows.  This.
Microsoft Office XP Illustrated Introductory, Enhanced Started with Windows 2000 Getting.
© 2004 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice SISP 6.1 Delta Training Documentation.
XP New Perspectives on Microsoft Office FrontPage 2003 Tutorial 7 1 Microsoft Office FrontPage 2003 Tutorial 8 – Integrating a Database with a FrontPage.
Gold – Crystal Reports Introductory Course Cortex User Group Meeting New Orleans – 2011.
OTDR “How To Demo” Training
JDS5 Training Guide. On Start Up you will see this screen click the OK button Click OK.
Corporate Customers Basic Services Intuit Financial Services University Business Financial Solutions Certification.
HOW TO INSTALL WINDOWS 7? This step-by-step guide demonstrates how to install Windows 7 Ultimate. The guide is similar for other versions of Windows 7.
Access Queries and Forms. Adding a New Field  To insert a field after you have saved your table, open Access, and open the table  It is easier to add.
Chapter 11 Collaboration Features for Workbooks Microsoft Excel 2013.
Customize Your View of Data Training Presentation for Supply Chain Platform: BAE Systems May 2015.
CACI Proprietary Information | Date 1 PD² SR13 Client Upgrade Name: Semarria Rosemond Title: Systems Analyst, Lead Date: December 8, 2011.
FOCIS Flex Introduction to Operation June FOCIS Flex Intro to Operation Outline Controls, Display and Interfaces Connector Adapter Tips Operation.
Part 1: Inspection and Cleaning
DSQR Training Reliance System
A step-by-Step Guide For labels or merges
T_C_N_L_G_ E D I D I E O Y O H I E B J I R E A A W.
About AirPrint AirPrint is an Apple technology that helps you create full-quality printed output without the need to download or install drivers.
Expense Report Training
Windows xp PART 1 DR.WAFAA SHRIEF.
Expense Report Training
Microsoft PowerPoint 2007 – Unit 2
Two methods to observe tutorial
Using Microsoft Outlook: Outlook Support Number
RapidFinder Analysis Software How-To Guide
Presentation transcript:

JDSU Test Equipment Training In Support of AT&T Requirements Effective 9/1/2014 Transmission Equipment Installation Procedures Michael L Yeilding - AT&T– Principal Product Development Engineer Neven Jambresic - JDSU – Product Line Manager

Inspection & Testing Fundamentals Reference Methods Equipment Setup Agenda Inspection & Testing Fundamentals Reference Methods Equipment Setup The Measurements/ Test Procedure Documentation and Report

Inspection & Testing Fundamentals

What Makes a BAD Fiber Connection? Today’s connector design and production techniques have eliminated most of the challenges to achieving Core Alignment and Physical Contact. What remains challenging is maintaining a Pristine End-face. As a result, CONTAMINATION is the #1 source of troubleshooting in optical networks. A single particle mated into the core of a fiber can cause significant back reflection, insertion loss and even equipment damage. Light Back Reflection Insertion Loss Core Cladding DIRT

Illustration of Particle Migration 11.8µ 15.1µ 10.3µ Core Cladding Actual fiber end face images of particle migration Each time the connectors are mated, particles around the core are displaced, causing them to migrate and spread across the fiber surface. Particles larger than 5 µm usually explode and multiply upon mating. Large particles can create barriers (“air gaps”) that prevent physical contact. Particles less than 5 µm tend to embed into the fiber surface, creating pits and chips.

Proactive vs. Reactive Inspection PROACTIVE INSPECTION: Visually inspecting fiber connectors at every stage of handling BEFORE mating them. Connectors are much easier to clean prior to mating, before embedding debris into the fiber. REACTIVE INSPECTION: Visually inspecting fiber connectors AFTER a problem is discovered, typically during troubleshooting. By this time, connectors and other equipment may have suffered permanent damage. Dirty Fiber PRIOR to Mating Fiber AFTER Cleaning Dirty Fiber PRIOR to Mating Fiber AFTER Mating and Numerous Cleanings

Fiber Contamination is the #1 Cause of Troubleshooting Fiber Contamination and Its Affect on Signal Performance 1 CLEAN CONNECTION Back Reflection = -67.5 dB Total Loss = 0.250 dB 3 DIRTY CONNECTION Clean Connection vs. Dirty Connection This OTDR trace illustrates a significant decrease in signal performance when dirty connectors are mated. The typical budgeted loss for a mated connector pair is 0.5dB This dirty connector caused ~4.9dB which is a 68% power drop Back Reflection = -32.5 dB Total Loss = 4.87 dB

Inspect Before You Connectsm Follow this simple “INSPECT BEFORE YOU CONNECT” process to ensure fiber end faces are clean prior to mating connectors.

Reference Methods and Insertion Loss Testing Section 2 covers reference methods and launch conditions.

Setting Reference – Two options: 1 Fiber Reference Connect the OLTS together w/reference jumper – reference power meter (set to 0dB) Light Source Power Meter Test Jumper Disconnect the fiber at the power meter. Connect a test jumper to the power meter. Add couplers (channel testing) or connect to bulkhead (link testing) and connect to fiber system under test There are three options for setting an optical reference between a source and power meter. The method used is determined by your regional or vendor-specific requirements. A couple things to note. Optical Loss Test Sets (OLTS) typically have a source and meter at EACH end so they measure two fibers at one time. For simplicity and clarity this slide is only showing a simplex setup – one light source to one power meter. When the term “test jumper” is shown this means a cord with “reference grade connectors”. These are connectors that provide much lower loss than “standard” connectors. Test reference jumpers are more expensive the regular patch cords. A one fiber reference uses one fiber – or test jumper – between the light source and the power meter. Note there are no couplers, bulkheads or other connections between the source and meter when the reference is performed. So ONLY the loss at the source-to-test jumper connection AND the test jumper loss are “referenced out”. Once the reference is performed, the test fiber is disconnected at the POWER METER. After you have done a reference, never disconnect your test jumper at the light source, at your transmitter, it will ruin the reference and will need to re-reference. A test jumper is then connected to the power meter. Now test jumpers are on the source and meter that need to connect to the system under test. If testing a channel you will need to use couplers at the end of the test jumpers. If testing a link, simply connect the test jumpers to the system under test at the bulkheads. This is the fiber reference method required for link testing for TIA standards. Coupler/Bulkhead Coupler/Bulkhead Light Source Power Meter Fiber System under Test Test Jumper Test Jumper OLTS = Optical Loss Test Set. Typically has Light Source and Power Meter at both ends. Simplex shown for clarity.

Summary of Reference Methods Difference is the number of bulkhead (coupler) connections referenced out of the loss measurement. One Fiber Two Fiber Three Fiber Light Source Power Meter The choice of which of the three reference methods to be used is determined by local standards, by vendor and if you are testing channels versus links. Bottom line is the difference between the methods is the number of connections that are referenced out of the actual loss measurement. In other words, after you perform a reference, and actually want to test, how many of the connections between your test jumpers and the fiber system under test are included in your loss measurement? The diagram here tries to illustrate this: If a one fiber reference was performed – both test connections to the system under test will be included in the loss measurement If a two fiber reference was performed – only one test connection to the system under test will be included in the loss measurement If a three fiber reference was performed – none of the test connections to the system under test will be included in the loss measurement. A couple final notes on referencing: Regardless of vendor or model, all optical sources should be allowed to warm up for about 5 minutes prior to performing a reference. On most Optical loss test sets designed for Tier 1 certification, there will be a setting for “reference method”. The physical configuration used to perform the reference MUST match the setting on the test device or your test margins are invalid. So if you set your test set up to do a three fiber reference but what you actually physically do is a one fiber reference, you have a completely invalid test result, especially your test margins are going to be completely invalid. NEVER disconnect the test jumper from the transmitter after a reference is performed – this will destroy the reference – you will need to do it again. Always check your reference by connecting the source test jumper to the power meter test jumper and performing a measurement. There is some variation in what you would expect to see when checking your reference – based on the quality of your test jumpers and the reference method used, certainly below 0.3 dB. One thing you want to watch for when checking your reference is “gainers” - where your test set shows a loss with a positive value - +0.2 dB for example. That is also an indication that you’ve got a bad reference and you’ll need to redo your reference. It is a good practice to save your reference check to have proof that a good reference was established prior to testing. If during the course of testing you question your results, simply check your reference again – re-reference if needed, save the result and carry on testing. Fiber System under Test Test Jumpers Test Jumpers Always check your reference! Connect test jumpers together and measure loss Ensure no “gainers” Save result for proof of good reference

Measuring Insertion Loss Single Direction Insertion Loss Measurement with a Source and Power Meter Reference first! -6dBm Zero Ref 0.00 dB r Light Source Power Meter Reference Measurement Light Source Power Meter -1.5dB You can perform this using either a source and power meter separately; Or you can use a loss tester (source and meter in one unit) to perform either a loop back (one unit) or two-way (using a test set at both ends) References are needed to ensure stable optical launch conditions and in order to perform a zero reference (measure dB loss, to avoid need for manual calculation) Insertion Loss Measurement 12

The Measurements This section will review the measurements for Tier 1 certification

Testing Requirements All test jumper end faces shall be inspected (and cleaned if necessary) prior to performing any loss testing per ATT-TP-76461 and/or ATT-TP-76417. Following the fiber end face inspection and loss measurement test the results shall be recorded on the New Fiber Inspection & Grading Form. This information is required to be loaded in to EJF under the following file name FBR_INSP.

Acceptable loss is based on several factors: Loss Limits Acceptable loss is based on several factors: Number of connections Number of splices Loss per Km (at specific wavelengths) Example allowable losses (TIA) Loss per connection = 0.75 dB Loss per splice= 0.3dB Loss per Km (slope) MM 850nm = 3.5 dB SM 1310 nm = 1.0 dB Tier 1 fiber certification not just measures loss but also it compares it to a loss limit to provide a pass/fail. The loss limit is a calculated limit based on several factors some of which the technician needs to set up in the OLTS. Each connection and each splice needs to be accounted for in the loss limit of a link and each is allowed an amount of loss. This slide shows a simple TIA example. Each connection is allowed 0.75 dB of loss and each splice is allowed 0.3 dB of loss. The third parameter that impacts the loss limit is the allowable loss for the fiber itself. Standards define the maximum loss per Km at the various wavelengths as shown here. The easiest way to explain and understand this is to look at a specific example on the next slide.

Testing Requirements If jumper loss reading is greater than 0.80dB, the installation supplier shall follow cleaning procedures in ATT-TP-76461 and retest. 2. If the loss is greater than 0.80dB, the jumper is not acceptable and shall be replaced. 3. If testing is done between two FOT panels, 0.75 dB is added to the maximum allowable loss the 0.75dB takes into account the loss in the (2) bulk head connectors. In this case the loss should be less than 1.55 dB. Reference ANSI/TIA/EIA 568-B.3 -Optical Fiber Cabling Components Standards The maximum loss allowed on a fiber cable (inside only) is calculated as follows: 0.75 dB (2) Connectors (Mated Pair) + 1.0 dB/Km of fiber cable + 0.3 dB per fusion or mechanical splice

2 connections (default for one fiber reference) No splices Fiber Test Example One Fiber Reference 2 connections (default for one fiber reference) No splices 300 meters of MMF Test Limit at 850nm: 0.75 dB per connector 1.5dB 300 meters (3.5 dB per km) 1.05dB Total 2.55 dB SM Fiber should be tested with 1310nm MM Fiber should be tested with 850nm

Equipment Set up OLP82 Fiber Overview Key Features & Functions Controls Operation Exporting to FiberChekPRO Using FiberChekPRO

Controls Patch Cord Microscope (PCM) OPM Test Head Cover FMAE adapters Connector Interface Universal 2.5 or 1.25mm Test Head Cover Battery Life 3.5” Touch Screen Graphic Interface Input Ports Control Panel Ethernet (OLP-87 only) Power 1x Micro USB LED Indicators 2x USB2 PCM controls (focus, test, magnification)

Control Panel INPUT SELECT KEY HOME – Press to go to the home screen MENU – Press to open a menu BACK – Press to go back one step INPUT SELECT KEY (ISK) – Press for fast toggling between devices POWER – Press to turn the instrument ON and OFF INPUT SELECT KEY Guides users through a proper test workflow. Provides simple step-by-step guidance to users with a repeatable, easy to follow process Ensures that the job is done right the first time. Drives the user’s behavior ARROW KEYS - Press to navigate through menu items Press to change values in the menus CENTER KEY - Press to confirm the selection SAVE – Press to save results LOW BATTERY – Glows Red when battery is low TEST IN PROCESS – Glows RED when a test is running in the background CHARGE – Glows AMBER when battery is charging; if the power is OFF, charging will continue with no LED indicator * Each application will only appear if it is available on the device, either on-board or via USB connection.

Operation: Exporting Data & Upgrade Firmware Export stored data to PC Connect via micro USB-to-USB2 cable (included) Import data to PC with included software OLP-82: Includes FiberChekPRO V1.5 Upgrade firmware Install the AT&T V1.5 of the FCPRO http://fcpro.updatemyunit.net/ Connect OLP82 via micro USB-to-USB2 cable In OLP82 setup select firmware (click update) FiberChekPRO

Home Screen Display OLP-82P INSPECT TEST Inspect and analyze fiber end faces, select acceptance criteria, detect scratches and defects, view PASS/FAIL results, save and recall data. Inspect (PCM) - Activates the integrated Patch Cord Microscope (PCM) if available on the device (ex: OLP-82P) Inspect (Probe) - Activates the handheld P5000i Digital Probe microscope (if connected to one of the USB ports) TEST View power measurement and PASS/FAIL results, edit acceptance criteria, save and recall results. Optical Power Meter (OPM) - Activates the on-board OPM on OLP-82 New capabilities will be added via new Firmware releases, which can be done remotely for existing units

Operation: General Setup System Settings Brightness, Date, Time, Time Format, Auto Off, etc. Access from Home screen menu Microscope Settings Auto Center, Focus Quality Meter, Device Button Function (Capture/Test) Access from Microscope application User Information* Configurable in device: Company, Location, Job ID, Operator, Rack, Panel/Shelf, Tray/Slot, Port. Access from Home screen menu & application

Operation: Inspection Select Acceptance Criteria Open the application (PCM or Probe) Press MENU Select PROFILE (SM, Post Polish) Select TIP Inspect & Certify connector end faces Focus the image Press the TEST button Press the SAVE button View stored results Choose RECALL IMAGE (from Application or Home Screen) Select all images you want to view Press MENU / VIEW Core Cladding Contact

Operation: Optical Power Meter Measure & Store OPM readings Select desired wavelengths (λ) – SM 1310nm & MM 850nm Select Relative (dB) power level Easily set reference measurements Save readings (up to 10,000 ) View stored results on the device Choose REVIEW OPM DATA (from Application or Home Screen) All saved results will be displayed OPM reading, time, date, wavelength & tone Customizable functions Customize the list of wavelengths you want available Measure & Store Immediately available out of box Also displays Tones @ 270Hz, 1kHz, 2kHz Customizable functions - Add any wavelenghs (valuable for WDM application with special wavelengths)

FCPRO - Easy to Use Interface Microscope Settings Simplified Microscope, Tip and Profile Setting Image Controls Magnification High/Low AutoCenter Results & Reporting Clear PASS/FAIL Results Click for details of result Focus Quality Meter Live, Test and Save Optical Power Meter Accepts JDSU USB Power Meters Integrates with Report Dedicated Tabs Inspection/OPM/Import Only appear if relevant

Archiving PDF Layout- Standard or Consolidated File Naming Images and analysis data obtained from FiberChekPRO can be archived in several different forms. PDF Compress analyzed data into smaller file size Layout- Standard or Consolidated Standard – Save one result per report Consolidated – Save many results in one report File Naming Rack, Panel/Shelf, Tray/Slot, Port #

OPM Integration on Certification Reports The Optical Power Meter menu allows you to configure options when using a USB-enabled JDSU OPM, such as the FI-series or MP-series. Checking the box next to Link OPM readings with fiber analysis allows you to associate power meter readings with a fiber analysis.

Tip Settings Standard Tips (with BAP1) Simplex Long Reach (-L) Tips This calibration setting is recommended when using standard tips with the FBPP-BAP1 barrel assembly (included and factory assembled to P5000 probe). Simplex Long Reach (-L) Tips This calibration setting is recommended when using long reach inspection tips.

The Test Procedure This section will review the measurements for Tier 1 certification

Test Procedure Steps Equipment required at: Location A Location Z Equipment required at: Location A : Fiber Inspection Microscope, Cleaning equipment and Optical Power Meter Location Z : Fiber Inspection Microscope, Cleaning equipment and Optical Light Source

Test Procedure Steps- Inspect & Clean Bulkhead Select the appropriate bulkhead inspection tip that corresponds to the connector type and install onto probe. Insert the scope into the bulkhead to inspect. Determine whether clean or dirty. If clean, do not touch it and CONNECT. If dirty, and cleaning is required, CLEAN. Inspect & Clean Patch Cord with PCM or Probe Select the appropriate patch cord adapter that corresponds to the connector type and install onto PCM. Attach the patch cord to the PCM or Probe. Determine whether clean or dirty. If clean, do not touch it and CONNECT. If dirty, and cleaning is required, CLEAN. Note: Wet – Dry Clean If the Dry Cleaning method doesn’t clean connector after 3 cleaning attempts, proceed with the Wet-Dry Cleaning.

Test Procedure Steps- Location A – Equipment needed: Inspection microscope, cleaning equipment, Optical power meter Set up Inspection microscope and reference optical light source and optical power meter. (see set up instructions) Inspect, clean (if needed) fiber trunk cable. Document inspection test result Enter note image as [location]- Fiber [channel #]A Example: “Fiber 1A” Before saving first inspection result go to MENU, MORE and CREATE NEW GROUP Type [channel #A] on base Fiber name and save test result. Example: “Fiber 1A”, “Fiber2A”, “Fiber3A”, etc…. to “Fiber 72A”. Insert test jumpers into the adapter for fiber under test Start the optical power meter; select the correct wavelength (the same wavelength as OLS on the Location Z). Record power level in dB by clicking “Save” Repeat the same procedure for each fiber in the fiber trunk. Inspect the test lead and next fiber port after each test

Test Procedure Steps- Location Z – Equipment needed: Inspection microscope, cleaning equipment, Optical Light Source Set up Inspection microscope and reference optical light source and optical power meter. (see set up instructions) Inspect, clean (if needed) fiber trunk cable. Document inspection test result Enter note image as - Fiber [channel #]Z Example: “ – Fiber 1Z” Type [channel #Z ] on base Fiber name and save test result. Example: “Fiber 1Z”, “Fiber2Z”, “Fiber3Z”, etc…. to “Fiber 72Z”. Insert test jumpers into the adapter on fiber under test Start the optical light source, select the correct wavelength (MM 850nm or SM 1310nm) and start the laser when Location Z is ready to test. Repeat the same procedure for each fiber in the fiber trunk. Inspect the test lead and next fiber port after each test.

Importing Data with FiberChekPRO (V1.5) Connect the compatible device with stored data to the PC and select the Import tab*. Select the desired Import Location from the dialog box marked Import Location. Click the IMPORT ALL button. This gives a summary of all the Stored Data on the connected device: Inspection Reports: Displays the count of all Inspection reports with PASS/FAIL analysis Captured Images: Displays the count of images that were captured and saved specifically as images OPM Measurements: Displays the total count of OPM measurements saved on the device Inspection Reports: Displays the count of all Inspection reports with PASS/FAIL analysis results, fiber images (both low and high magnification), linked OPM readings, user information, date, time, and notes that are stored on the device. Captured Images: Displays the count of images that were captured and saved specifically as images only (not with PASS/FAIL analysis results). Note: Images associated with a report are consolidated as part of the “Inspection Reports”. OPM Measurements: Displays the total count of OPM measurements saved on the device (including OPM readings that are linked with inspection reports). The imported data will be saved in a dedicated folder located in the defined archive location. The folder will be named by Year+Month+Date as follows “YYYYMMDD” (ex: 20121129 = November 29, 2012). The folder will contain the all the Inspection Reports and Captured Images as individual files and a single .csv file with all of the stored OPM Measurements. The .csv file will contain a base name and a date increment as follows “BASE-YYYYMMDD.csv” (ex: BUILDING1-20121129.csv). *NOTE: This tab will only appear when a compatible device with stored data is connected.

Fiber Connector Inspection & Grading Test Record Form

Fiber Connector Inspection & Grading Test Record Form Instructions to embed .pdf files into the table:   Select the field in the table in which you would like to embed the .pdf file. Click on the “Insert” tab in the menu toolbar In the Text group, click on “Object” In the Object dialog window, click on the “Create from File” tab Check the “display as icon” checkbox Click on “browse…” and browse to the file you want to embed Click on “Insert”, which should take you back to the “Create from File” tab Click on “OK” . The file should be embedded in the table.

Fiber Connector Inspection & Grading Test Record Form Example All fiber inspection test results shall be documented on the Fiber Connector Inspection Test Record form.  Note: Form can be found on the Technical Publications and NEBS website at: https://ebiznet.sbc.com/sbcnebs/

Key Contacts Name Contact Info Role/Service Todd Watkins JDSU Todd.Watkins@jdsu.com (972) 692-3781 Equipment Information Neven Jambresic Neven.Jambresic@jdsu.com (425) 368-2216 JDSU - Technical Assistance Center tac@jdsu.com 855-275-5378 option 3,1,1 Technical Support JDSU -Anjanette Robinson Anjanette.Robinson@jdsu.com (240) 404-1541 Equipment Ordering TESSCO – Steve Bennet bennetts@tessco.com (410) 790-7347 Electro Rent - Cory Jenson cjenson@electrorent.com (800) 688-1111 Equipment Rental TRS-Rentelco – James Ranstrom James.Ranstrom@trs-rentelco.com (800) 874-7123

Online Training Materials Training Webinar: SmartClass Fiber Video: OLP-82P Setup Procedures Video: OLP-82P Test Workflow FiberChekMOBILE Video: How it works