Making an IMPACT on Water Treatment Industry

Slides:



Advertisements
Similar presentations
Process Of Reverse Osmosis Plant
Advertisements

25.aug.2003 A selection of level sensors made in stainless steel.
Preferred Utilities Manufacturing Corp.
Circulating Water System
Pipes Single Wall Pipes Double Wall Pipes
CE 370 Filtration.
Fivalco ® Flow Control Products. Full Product Lines  Fivalco Produces a complete line of Flow Control products for HVAC and Water applications  Gate,
The Swagelok® SK series and AFS Multipurpose Ball Valves
GAS PURGE SYSTEMS ‘Manly Hydraulics Laboratory’ 28 th June 2011.
ZepZep C4 Entryway Foam System uctionInstruction Manual
Water supply and drafting. Objectives Understand and be able to demonstrate the different hydrant lays and hook ups Explain/demonstrate how to operate.
HVACR312 - Refrigeration Metering Devices.
Welcome to the HYCOA Solution
Dennis Sabre Fire Appliances
2035 Series. Common Components The design of the 2035 Series valve includes many proven components for assured reliability. These items include: –Same.
HCS Series Screw Compressor Packages. 2 HCS Series.
January 22, Advanced Modular Sample System Richard E. Hughes.
Module Vessel Connection Concept Steve Virostek Lawrence Berkeley National Laboratory AFC Module Meeting April 23, 2004.
OLYMPUS Collaboration Meeting Cooling Water David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY
GD150 Liquid bulk contactless compressor. GD150 Compressors.
Purpose of Standpipe and Hose Systems
9/30/04AME 470 – Team Unum Team Unum Connection System to Air Source and Inflatables PDR # 4 September 30, 2004.
For the interconnection of pneumatic components and systems
5.1.2 Student Book © 2005 Propane Education & Research CouncilPage 1 NFPA 58, LP-Gas Code, sets out the minimum valve and fitting requirements for propane.
Submersible Seal Top Down DP Level Assembly. DP Level Solution for Top-Down Level Measurement Applications Challenge: Many tanks go un-instrumented in.
©DYMAX Corporation Making Manufacturers More Efficient DYMAX Dispensing.
MOST RELIABLE COMBINATION MASTER VALVE, WATER METER AND FLOW SENSOR
Hydraulic Engineering
Fire Pump Functions The main function of a fire pump is to increase the pressure of the water that flows through it. Inadequate or nonexistent municipal.
Mounting Direction Water Cooler Best solution OK Risk of air bubbles in the system Heatsink Water channels Inlet Outlet.
Balcrank Products Inc. Air Operated Pump Training Presentation, 2/2007.
OIL & GAS FIELD SUPPLIES DIVISION Oil & Gas Field Supplies Division deals in supply of Gate Valves, Ball Valves, Butterfly Valves, Control Valves, Check.
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
Pneufit push-in fittings For general purpose pneumatic applications.
11 Going Above & Beyond in Above Ground Storage Tank Equipment Solutions.
EEV-KIT For Single refrigeration system. Preliminary information, all of contents are subject to final confirmation by MHI 2 Contents 1. Single refrigeration.
Pressure Gauge Load Cell Pressure Release Valve Compression Lid Disc Backers Base Water Fz Air Core Bushing W.L. Gore – Lateral Permeability Test Device.
Firefighter III Module B Water Supply (4-19) (4-19)
Compressor Replacement – ODU
Vacuum Unit ZK2 Series The ZK2 series is a product compatible with both of the vacuum ejector and vacuum pump system.
Slider Type 11-LEJS Clean Series Electric Actuator Vacuum suction
1 1 Staying in Compliance: Spill and Overfill Presented by: Brent Roth OPW Retail Fueling IPECA UST Seminar 2015.
S INGLE -U SE S URGICAL S UCTIONS Equivalence Chart.
ELLIPTICAL HEAD PROTECTING COVER 01_INSTRUCTION DISCONNECTING THE ELLIPTICAL HEAD.
Flow and Control Engineering Supplying Control Valves & Instrumentation to Heavy Industry and Chemical Manufacturing. Multi-Stage Steam & Condensate Control.
6.5 Recommended Velocity Of Flow In Pipe And Tubing.
Line Blinding/Blanking Options
Hub 4 Water Media Filters
REVERSE OSMOSIS PLANTS 5-35kl/day
Hub 4 Water Hub 4 Water Softener
REVERSE OSMOSIS PLANTS kl/day
Hub 4 Water Carbon Filters
Date of download: 12/24/2017 Copyright © ASME. All rights reserved.
Challenges for FCC-ee MDI mechanical design
Vertical Pressure Filters
Hot water Systems Heaters.
Duo-AquaTrap™ - ON BOARD FILTERS
MINI 1A iAquaMax™ Kidney / water removal system
For the interconnection of pneumatic components and systems
Customer Presentation
1A iAquaMax™ Kidney / water removal system
Stainless Steel Corrugated Braided Hose Metal Expansion Joints
The perfect fit for corrosive wet areas Maintenance Units, Series MH1
FLOWTECH PRODUCTS LLP “PIONEERS IN FLOW CONTROLS & MEASUREMENTS”
 PURPOSE OF LUB OIL SYSTEM In the 250 MW KWU turbines :  Single oil is used for  A] Lubrication Of All Bearings,  B] Control Oil For Governing System.
Skid Mounted Water Treatment Plant
 R2 Four Basic Components of a Refrigeration System #4 Metering Devices.
Presentation transcript:

Making an IMPACT on Water Treatment Industry INITIATIVE Making an IMPACT on Water Treatment Industry SOLO Manual Multiport Valves Distribution Systems Automatic Multiport Valves Remote monitoring systems Automatic Dispensing Systems

Initiative Multiport Valve Selection Its important for the best performance of the water treatment system…. 65nb 20nb 40 25nb 40nb In/out adaptor INITIATIVE

Selection of the MPV based on.. Resin Quantity (for softeners/demineralisers) 20nb MPV 25nb MPV 40nb MPV 65nb MPV Resin Quantity (Liters) Up to 80 Up to 250 Up to 1000 Up to 5000 In case of multiple units in series it’s good not to select an MPV for highest flow. Desirable maximum flows for stand alone & multiple units are as follows Based on flow.. Type of Unit 20nb MPV 25nb MPV 40nb MPV 65nbMPV Service(Up to) 2.5 5.0 12 35 Backwash Flow 3.5 7.0 15 45 INITIATIVE

Size of Vessel.. INITIATIVE

Vessel Opening Size Options: 2 ½” Threaded 4” Threaded 6” Flanged In/Out Adaptor 20NB 25 NB & 40NB 65 NB 4” x 2 ½” adaptor required for 4” vessel End Connections In/Out Adaptor 20nb MPV 25nb MPV 40nb MPV 65nb MPV ½” Hose Nipple ½” BSPF 1" BSPM Union 1 1/2" BSPM 2 ½” Union M.S.Flange INITIATIVE

Suction Line for softner MPV Suction Filter with NRV Suction Line for softner MPV 20nb MPV 25nb MPV 40nb MPV ¼” Suction filter with NRV ¼” Brine Director ½”Double Strainer ½” Brine Director ¾” Brine Director Ejector Suction 20nb MPV 25nb MPV 40nb MPV 65nb MPV Suction Flow at 2.5 Kg/cm2 Softener 100 LPH (1:2) 350 LPH (1:1) 500(top mount)/1000 (side mount) LPH (1:1) 2500 LPH INITIATIVE INITIATIVE

Selection Summary 20nb 25nb 40nb 65nb Resin (liters) Up to 80 Flow (m3/h) 2.5 5.0 12.0 35.0 Mounting Top Top/Side Side End Connection ¾” BSPM 1" BSPM Union 1 1/2” BSPM Union/Flanged 2 1/2“ BSPM Union/ M.S. Flanged Suction Line ¼” Suction filter with NRV ¼” Brine Director ½”Double Strainer ½” Brine Director ¾” Brine Director Ejector Suction Softener(LPH)@2bar 100 LPH (1:2) 350 LPH (1:1) 500/1000 2500 LPH ***Port Orientation for all MPV is left to right standard except 65nb. For filter right to left possible INITIATIVE

Riser Pipe Details.. Riser Pipe Size (mm O.D.) Length “L” In/Out Adaptor 20 or 25 9 mm below vessel top 20nb 25 25nb 32 26 mm above vessel top 25nb with 4” x 2.5” Adaptor 34 mm above vessel top 40nb 24 mm above vessel top 40nb with 4” x 2.5” Adaptor 32 mm above vessel top INITIATIVE

Selection of Distribution System Top mount MPV comes with a distribution system. In case of side mounted vessels: Types Double Strainer: for flows up to 5M3/Hr. Top- Strainer & Bottom-Hub and Lateral: for activated carbon filter. Top-Hub & Bottom-Hub & Lateral: for sand filters Top & Bottom-Hub Lateral: For flows more than 5m3/Hr Top & Bottom-Double Hub & Lateral: For flows more than 15 M3/hr and up to 40 M3/Hr INITIATIVE

Distribution Systems Side Mount Distribution System - 5M3/Hr INITIATIVE

Distribution Systems Side Mount Distribution System -12M3/Hr INITIATIVE

Distribution Systems 6” Flanged Vessel 4” Threaded Vessel Side Mount Distribution System - 25M3/Hr 6” Flanged Vessel 4” Threaded Vessel For Flows Up to 40 M3/Hr For Flows Up to 25 M3/Hr INITIATIVE

Distribution Systems Side Mount Distribution System - 40M3/Hr In/Out Adaptor(IO1) Single Strainer with 25 OD riser pipe(SS2) Riser Tube 25 OD (Not in Scope) Single Strainer with 25 OD riser pipe (SS3) Side Mount Distribution System - 40M3/Hr In/Out Adaptor for 2 1/2" Top opening For 6inched flanged vessels. INITIATIVE

Accessories Pressure Gauge Adaptor In/Out Adaptor Air release Valve 3” x 3” Male-Female Adaptor for 40mm thread length vessels 65nb Ejector S-Shaped Adaptor 20nb&25nb 4” Male x2.5’ Female Adaptor INITIATIVE

that makes all the difference…. Initiative that makes all the difference…. Thanks… INITIATIVE