EXCITATION SYSTEM.

Slides:



Advertisements
Similar presentations
ENERGY CONVERSION ONE (Course 25741)
Advertisements

Chapter 11 DC Motors. Chapter 11 DC Motors Objectives Explain the operating principles of dc motors. Explain counterelectromotive force. Identify various.
Traction Control of Electric Locomotives
Variable Frequency Drives VFD Basics
DC MOTORS SEE 3433 ELECTRICAL MACHINES. DC MOTOR - Shunt motors - Separately excited - Series (we’ll look briefly)
Power System Fundamentals
Chapter 4 Synchronous Generators
EEEB2833 Electrical Machines & Drives
SYNCHRONOUS MACHINES SUBMITTED BY: Ms. APOORVA KANTHWAL
DC Motors KL3073.
12/3/2002BAE Electric Motors Classification / types –DC Motors –AC Motors –Stepper Motors –Linear motors Function –Power conversion - electrical.
3. ARMATURE VOLTAGE AND GOVERING EQUATIONS
DC MOTORS SEE 3433 ELECTRICAL MACHINES. DC MOTOR - Shunt motors - Separately excited - Starter.
Lesson 37 AC Generators II
WISA Meeting Help Arrange a Speaker, Write Bio, Introduce
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Three-Phase ac Voltage Generation
ET 332a Dc Motors, Generators and Energy Conversion Devices 1 Lesson a.pptx.
Motor ELECTRICAL ENERGY Mechanical Energy.
Speed Control of D.C. Motors
EE&I QUIZ.
Lesson 9: Electrical Components
Chapter 24 Thyristors. 2 Objectives –After completing this chapter, the student should be able to: Identify common types of thyristors. Describe how an.
5.1 INTRODUCTION TO POLYPHASE SYNCHRONOUS MACHINES
Chapter 19 AC Motors.
DC Machines.
AC vs. DC The production of and use of electricity is an expensive business.Therefore the most efficient use of the resource is required. The most efficient.
Unit 4: Electromechanical drive systems An Introduction to Mechanical Engineering: Part Two Electromechanical drive systems Learning summary By the end.
Closed loop control.
Power Factor Improvement Lecture 9. Normally, the power factor of the whole load on a large generating station is in the region of 0·8 to 0·9. However,
1 Institute of Mechatronics and Information Systems Control and Driving Systems.
Motors and Generators.
Electric motors KON-C2004 Mechatronics Basics Tapio Lantela, Nov 2nd, 2015.
DC Machines.
ELEC 3105 Basic EM and Power Engineering Rotating DC Motor PART 2 Electrical.
REACTIVE POWER COMPENSATION
Speed Control in DC Motors
POWER ELECTRONICS IN SHIP PROPULSION ELECTRIC MOTORS.
Special-Purpose Electric Machines The machines introduced in this lecture are used in many applications requiring fractional horsepower, or the ability.
© NOTES - Doc. Ing. Pavel Pivoňka, CSc. DC MOTORS ROTATING MACHINES - SAME CONSTRUCTION AS GENERATORS: MOTORIC RUN = 1 working status of DC machine SUPPLY.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
Elements of Electrical Design HASMUKH GOSWAMI COLLEGE OF ENGINEERING
INTRODUCTION A 3-phase induction motor cannot be operated at variable speed. 1-phase induction motor is not self starting. Thus, A.C. commutator motors.
HNC/D Engineering Science
Rectifiers, Inverters & Motor Drives
Electric Motors and Generators
DC Generators.
Controlled-Rectifier Fed Drive
Speed control of three phase induction motor
ELEC 3105 Basic EM and Power Engineering
AC and DC motors.
Electric Machines In electrical engineering, electric machine is a general term for electric motors and electric generators and other electromagnetic machines.
Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB
Wind turbine technology
A Presentation of Testing Of D.C Machine
Subject : Electronic Machines
UNIVERSAL MOTORS.
APPLICATIONS Reference: Textbook-Chapter 6,8 & 9 'Power Electronics',C
Motor Drive Prof. Ali Keyhani. Modern Variable Speed System A modern variable speed system has four components: 1. Electric Motor 2. Power Converter -
Electromechanical Systems
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Why is starter necessary for a three-phase induction motor?
מנועים חשמליים המרת אנרגיה והינע TO THE TRAINER
MOTOR SELECTION Electric motors should be selected to satisfy the requirements of the machines on which they are applied without exceeding rated electric.
EET 323 – Electrical System Design Lecture 13: Motor Circuits
Induction Motor Drives
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
CHAPTER 2: DC DRIVES (Part 3)
Rectifiers. Introductions of rectifiers: IN PARTICLE ACCELERATORS, ELECTRONS OR OTHER CHARGED PARTICLES ARE FORCED TO MOVE ALONG ORBITS OR TRAJECTORIES.
Presentation transcript:

EXCITATION SYSTEM

SHUNT Excitation AVR power supply & reference voltages. shunted on the alternator output terminals. AVR generates and regulates the excitation current as a function of the alternator output voltage. Extremely simple design and ideal for basic applications. Cannot tolerate high overloads. Does not offer a short-circuit capability.

PMG Excitation Alternator same design as SHUNT. AVR powered by a permanent magnet generator (PMG). PMG delivers constant voltage independent of the main winding. The voltage reference is shunted on the alternator output terminals. Suitable for demanding applications. PMG system has a high overload capacity Improved performance over SHUNT system.

AREP Excitation The AVR power supply voltage comes from 2 independent auxiliary windings. AVR power supply is independent of the voltage sensing measured on the alternator output. Excitation current to the alternator exciter is independent of voltage distortions (harmonics) due to the load. AREP system gives high overload capacity & short-circuit capability. Particularly suitable for demanding applications

EXCITATION SYSTEMS PMG AREP SE ADVANTAGES DISADVANTAGES High starting capacity High starting capacity ADVANTAGES Short-circuit capability Short-circuit capability Self protected against short circuit Intrinsic build-up No extra length No extra length Extra length Specific winding No short- circuit capability DISADVANTAGES High number of components Small added cost Low starting capacity Added cost Sensitive to distorting loads if thyristor controlled

HIGH OVERLOAD - SHORT CIRCUIT VOLTAGE (V) SE CHARACTERISTIC ( or auxiliary winding H1/ AREP) AREP/ PMG CHARACTERISTIC AREP SERIES ( Auxiliary winding H3/ AREP) SUSTAINED VOLTAGE DIP LOAD % 100% 200% 300% LOW OVERLOAD HIGH OVERLOAD - SHORT CIRCUIT

3-Phase PMG Excited, 3-Phase Sensing

3-Phase Self Excited, 3-Phase Sensing

3-Phase AREP Excited, 3-Phase Sensing

EFFECT OF DRILLING RIG LOAD ON ALTERNATOR DESIGN

DRILLING RIG: A drilling rig creates a borehole, or well, where oil and natural gas can be extracted for the production of fuels and other petroleum-based products. Drilling rigs may be described as mechanical or electric. These terms refer to the method in which power is supplied to the larger equipment on the rig. On mechanical rigs, power from the engines drives the rig equipment either directly, through a clutch or through a torque converter. Electric rigs use engine power to drive one or more generators. The generated electricity is then used to operate motors for the larger equipment on the rig. There are three types of electric rigs: DC (Direct Current) SCR (Silicon Control Rectifier) VFD (Variable frequency Drive)

ELECTRIC RIG: Electric motors power the draw works, rotary table, pumps and other systems with electricity from the generator. These applications are called electric drilling rigs or electric rigs. The electric motors used for hoisting, drilling and pumping require high torque at zero rpm and variable speed characteristics for efficient operation. These characteristics are possible using the following methods: Direct Current (DC) Generators Alternating Current (AC) Generators with Silicon Controlled Rectifiers (SCR) AC Generators with Variable Frequency Drive (VFD) Motors

GENERATOR SIZING A rig operating with the power limiter light on does not mean the engines are being efficiently operated. Larger kVA generators (or other remedial action) may be needed because generators may be at kVA limit and engines at only 30 to 50% load. A difficulty in efficiently sizing and operating an SCR or DC rig is the common assumption that “x” amperes represents “y” power; this is not true. If power factor is 1.0, then “x” amperes represents “y” power. At power factors below 1.0, power is less than the amperes indicate. A power factor from 0.3 to 0.9 on an SCR rig, under steady-state conditions, is evidence that generator sizing is important. During hoisting, power factor varies from 0.0 to 0.95. There may be cases where the minimum number of engines cannot be operated because of a high generator kVA requirement. Before examining these variables, it is first necessary to review some characteristics of DC motors

DC Motor Characteristics The rpm of DC motors is primarily controlled by the voltage to the motor (recognizing that motor type series, shunt and control system field weakening, etc. is related factors). Ampere draw of the motor controls torque output of the motor. This leads to the realization that a DC motor can work hard at low rpm (draw high amperage and produce high torque) and not load the engine (but load the generator) when operating at low DC voltage/low rpm. A method to calculate AC generator power factor due to current draw of a DC motor powered through an SCR system.

Mentioned graph the effect of motor rpm (or DC voltage) on the power factor of the driving AC generators. For a constant rpm (DC voltage), power factor is the same from no load to full load. The best way to improve system power factor is to ensure that DC motors are run at as high an rpm as possible. Every DC ampere presents a 0.85 kVA load on the generator, regardless of DC power. Operating a DC motor at high rpm reduces ampere load, therefore kVA