1 The ProMus Pump A New Direction in ProMinent Metering Pumps.

Slides:



Advertisements
Similar presentations
A force applied over a surface is pressure.
Advertisements

Plunger Pump Basic Theory (1/11)
VSH2 Nitrogen Over Hydraulic Unit
Landstown High School Governors STEM & Technology Academy
Lance Control System Thomas Gradwohl / Alexander Haug.
OFFICINE MECCANICHE GALLARATESI
References Which were useful? Sources Fluid Power with Applications; Anthony Esposito Basics of Hydraulic Systems Qin Zhang Hydraulic and Pneumatics.
Hydraulic Power Assist
Mechatronics Department Graduation Project II. OutlineIntroduction. Methodology. Mechanical Design. Control Design.
Fluid Power Systems Mill Creek High School Power and Energy.
Simple Pressure Control Valves
Metering Pumps and Pump Systems
Fluid Power Introduction
VALVES TYPE & FUNCTION VALVES.
COMMERCIAL REFRIGERATION
Basics of Pump Vigyan Ashram, Pabal.
10. PIPINGS/VALVES and PRESSURE VESSELS
Introduction to Basic Hydraulics
Presented to: International Aircraft Systems Fire Protection Working Group By: Date: April 2-3, 2008 Federal Aviation Administration Next-Generation Oil.
Goulds ISO Series ISO End Suction Centrifugal Pump
PUMPS, VALVES, & FANS …Moving fluids Objectives Comprehend the basic construction and application of valves used Comprehend the basic construction and.
Actuators.
AIRCRAFTS HYDRAULIC SYSTEM
Fluid Power Introduction
5.1.2 Student Book © 2005 Propane Education & Research CouncilPage 1 NFPA 58, LP-Gas Code, sets out the minimum valve and fitting requirements for propane.
Experts in Chem-Feed and Water Treatment General Hydraulics Fluid Mechanics.
Control of Pneumatic Energy
Specifying Pumps. Prepared by Martin Ryan, 2013 Training Series: Using Aspen Technology Economic Evaluation Suite.
Experts in Chem-Feed and Water Treatment ProMinent Fluid Controls, Inc General Product Overview.
Chapter 10 Fluid Power Systems.
INTRODUCTION Hydraulics is based on the fact that liquids are incompressible Hydraulic system is a system where liquid under pressure is used to transmit.
IT 264 Industrial Fluid Power
Pneumatic and hydraulic actuation systems
PUMPS, VALVES, & FANS …Moving fluids Objectives Comprehend the basic construction and application of valves used Comprehend the basic construction and.
June 1999ProMinent Fluid Controls1 alpha Series Metering Pumps ProMinent noelt: NEW CI noelt: NEW CI.
Experts in Chem-Feed and Water Treatment Solenoid versus Motor-driven.
Hydraulics. An area of engineering science that deals with liquid flow and pressure.
Experts in Chem-Feed and Water Treatment Delta Presentation.
Experts in Chem-Feed and Water Treatment Where Are The Opportunities & What Are The Applications.
Makro Series Metering Pumps
Experts in Chem-Feed and Water Treatment Specialty Metering Pumps and Feed Equipment ProMinent Orlita.
Experts in Chem-Feed and Water Treatment beta Metering Pumps 1.
Fuel System Carburetor A device that mixes air and fuel in correct proportion for efficient combustion. Stoichiometric Ratio 14.7 : 1 (Air : Fuel)
Experts in Chem-Feed and Water Treatment EXtronic Explosion-Proof Pump.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Experts in Chem-Feed and Water Treatment Fluid Engineering, Inc. Southern Company Services Cooling Tower Chemical Feed Skids Plant Franklin Combined Cycle.
Hydraulic Flow Control MECH1300 Topics Flow Control Valve Types Flow Coefficient Circuits Cushioned Cylinders Flow Dividers Flow Control Valve Specifications.
Valves In Industry (Part 1)
Submitted by Pradeep pataskar Roll no.11031M02034.
Contents Click a Section Tab.
Positive Displacement Pumps
Fluid Power Introduction All Images reprinted with permission of National Fluid Power Association.
FLUID FLOW FOR CHEMICAL ENGINEERING Dr Mohd Azmier Ahmad Tel: +60 (4) EKC 212 CHAPTER 8 (PART 2) TRANSPORTATION SYSTEM.
Session 6 - Agenda BREAK Activity Est. Time 1. Agenda
TYPE “HOS” 6” Stroke Compressor & Ancillary Equipment
Linear actuator Cylinders Single acting Double acting
REACH 1 REACH REACH Introduction Capacity range 0.28 l/h, 4 bar
Engineering II – August 2016
GOVERNMENT ENGINEERING COLLEGE DAHOD
Fluid Power Introduction
HYDRAULICS & PNEUMATICS
Cylinder Cushioning mechanism
Fluid Power Introduction
OH3 or OH5 Direct Drive API 610 Centrifugal Pumps
ME444 ENGINEERING PIPING SYSTEM DESIGN
SB Packing Automatic Downpuller Power Unit
Hydraulic Power basics.
PUMPS AND DRIVERS NCCER
Presentation transcript:

1 The ProMus Pump A New Direction in ProMinent Metering Pumps

Experts in Chem-Feed and Water Treatment 2 ProMus Training Sections  Bridging the Gap  Technical Review  Sales Review

Experts in Chem-Feed and Water Treatment 3 Bridging the Gap  Pumps Needed for Heavy Industrial Applications  Sigma’s Not Always Suitable  Hydro and Makro Only Partial Solution  Need Higher Pressure  Orlita is too Large and Specialized  Need for API 675 General Compliance

Experts in Chem-Feed and Water Treatment 4 API 675 Key Points  Removable Check Valves Spool pieces acceptable if proposed  Adjustable Over Turndown While Running  Rated for 110% of Maximum Specified Flow  Steady State Flow of 1% Over 10:1 Turndown  Flow Repeatability of +/-3%  Connection Sizes ½” Through 1-½” (Really!)  Double Check Valves When Specified

Experts in Chem-Feed and Water Treatment 5 API 675 Key Points  Diaphragms Provisions to prevent excess flexure (Contour Plates?) Double Diaphragms when spec’d  Internal Relief Valve Set at 10% or 25 psig Over Rated Pressure, Whichever is Higher  Packed Plunger Pumps Require Ext. PRV  Stroke Adjustment – Manual or Auto Visual indication of Stroke Setting for both Locking Device

Experts in Chem-Feed and Water Treatment 6 API 675 Key Points  Special Tools (upon request)  Hydrotest to 1.5x MAWP (Maximum Allowable Working Pressure)  Repeatability and Linearity Test 100, 75, 50, 25, 10 Percent Up and Down (10 Point)  Data and Documentation Requirements

Experts in Chem-Feed and Water Treatment 7 API 675 Specs You Don’t See  Cast Iron Drive Case  Stroke Speed Limitations  Hydraulically Actuated Diaphragm  Mechanically Actuated Diaphragm  Restrictions on Lost Motion Control of Flow

Experts in Chem-Feed and Water Treatment 8 Technical Specifications  Hydraulically Actuated Diaphragm Pump  Capable of 0.61 gph to 101 gph  Capable of Pressures to 3500 psig  Mechanical Lost Motion

Experts in Chem-Feed and Water Treatment 9 Technical – ProMus Features  Materials – 316ss Alloy 20, Hast C – future development  Modular Design – Maximum Interchangeability 5 Gear Ratios 8 Plunger Sizes 3 Head Sizes (17, 30 & 40) 1 Drive Size  Internal Pressure Relief (Adjustable)  Mechanically Actuated Hydraulic Refill Valve  Automatic Hydraulic Air Bleed Valve

Experts in Chem-Feed and Water Treatment 10 Technical – ProMus Features  10 Turn Micrometer Stroke Adjustment 10:1 Turndown Ratio on Stroke  Nema 4 and Nema 7 Stroke Actuators Avail.  Can Utilize Variable Speed Drives*  Double Ball Check Options (17 & 30 Heads)  Visual Indication of Relief Valve and Air Bleed Valve Operation

Experts in Chem-Feed and Water Treatment 11 Technical – ProMus Specifications  Minimum Backpressure – 22 psig  Maximum Suction Pressure – 50 psig  Maximum Viscosity – 200 cps (500 cps w/ spring)  Oil Quantity – 1.5 quarts  Oil Type – Mobilube 1 SHC 70W-90 or equal  Priming Lift – 5 ft  Suction Lift – 7.5 ft  Weight – approx lb w/o motor

Experts in Chem-Feed and Water Treatment 12 Technical – ProMus Specifications  Operating Temp. Range – 15 to 105 F  Maximum Process Fluid Temp Continuous – 195 F Intermittent – 250 F  Permissible Humidity – 95% Non- Condensing

Experts in Chem-Feed and Water Treatment 13 Technical – Motors  Need to Know Class, Division & Group Class – Gas, Vapor, Liquid or Dust Division – When Combustible is Present Group – Type of Combustible Material  Explosion Proof Motors Class 1, Division 1 Class 1, Division 2 if Single Phase Power Be aware of Group required for motor

Experts in Chem-Feed and Water Treatment 14 Sales – ProMus vs mRoy  Newer Pump Design Incorporates newer hydraulic refill technologies Will not fail on starved suction conditions  Modular Simple to modify in field  Easy to Hydraulically Prime  Repairable Check Valves  Very Price Competitive!!!!

Experts in Chem-Feed and Water Treatment 15 Sales – Applications  Chemical Plants Catalysts for Process Additives for Plastics Defoamers  Oil & Gas Refineries Oil or Fuel Additives  Power Plants Water Treatment Boiler Feed  Boiler Feed Applications O 2 Scavengers Anti-scalants Amines Phosphates pH Control  LNG Plants Odorant (Mercaptan)