Evaporative Light Scattering Detector

Slides:



Advertisements
Similar presentations
Gas Chromatography Introduction 1.) Gas Chromatography
Advertisements

Gas Chromatography 427 PHC.
Evaporative Light Scattering Detector Product Range
Size Exclusion Chromatography
KROMATOGRAFİ Sedat Türe. HPLC Liquid Chromatography.
Figure 1. Influence of sample solvent on peak shape. The sample is dissolved in buffer with (a) 0%, (b) 30%, (c) 50%, and (d) 70% acetonitrile. Sample.
HPLC Systems. Column Chromatography HPLC Modes HPLC – System Components.
Chromatographic detectors for Liquid Chromatography.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Lecture 21 HPLC-2 Instrumentation. Column Injector Detector Chromatograph Data Processing.
HPLC Bulk Property Detectors
Pn. Suryati Bt. Syafri 2009 High Performance Liquid Chromatography (HPLC)
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Chromatography Year 12.
Effect of Packing Particle Size on Plate Height. Resolution between 2 adjacent peaks.
High Performance Liquid Chromatography High Performance Liquid Chromatography Chem. 331.
Prabh Jassal SUPA Che113 Forensics Ms. Tolentino.
Chapter 6 - Chromatography
Introduction to High Performance Liquid Chromatography.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
Drs. Wei Tian & Yanhui Chen Sep-Dec Main Content Chromatography Analysis Gas Chromatography (GC) High Performance Liquid Chromatography (HPLC)
High Performance Liquid Chromatography
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 22 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Chromatography Chapter 6.
Magnet Analytical Chemistry Unit 4
Created with MindGenius Business 2005® Supercritical Fluid Chromatography Supercritical Fluid Chromatography Supercritical fluids Occur above a critical.
By: Thilag.k & Stephen. What is Hpcl??? Hplc or high performance liquid chromatography is the most widely used analytical separation technique. The difference.
GC Advantages 1. Very Large N (Very Long Columns) 2. No Packing Material (A=0) 3. Simple Mobile Phase (Compressed Gas) 4. Universal Detectors (FID) 5.
Chromatography vObjective  To understand the principles of chromatography and know the specific types of Chromatograph used in the analysis of environmental.
High Performance Liquid Chromatography Instrumentation.
1. Fast Protein Liquid Chromatography 2 FPLC A semi-automatic microprocessor controlled machine used primarily for the separation of macromolecules A.
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
Comparison of Competitors’ Evaporative Light Scattering Detectors
Gihan Gawish.Dr High Performance Liquid Chromatography.
The Use of Evaporative Light Scattering Detection in Pharmaceutical Analysis 1.
Comparison of Competitor
First Impressions Compact, modern design Flat top Small footprint, stackable Operation via control panel and simple keypad Column connection at front of.
Gas Chromatography Lecture 38.
PL-ELS 2100 Ice. PL-ELS 2100 Ice Evaporation at Sub Ambient Temperatures The PL-ELS 2100 Ice comprises an Integrated Cooled Evaporator in combination.
HPLC detectors Adapted from: HPLC for Pharmaceutical Scientists
Introducing the PL-ELS 2100 & PL-ELS 2100 Ice Evaporative Light Scattering Detector Presentation to describe the state-of-the art developments in ELS.
Analytical Separations
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
HPLC – High Performance Liquid Chromatography
Best Broken into four categories
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
HPLC.
Chapter 28 High Performance Liquid Chromatography.
Biochemical instrumental analysis - 11 Dr. Maha Al-Sedik 2015 CLS 332.
HPLC 1. Introduction 1.Introduction  INSTUMENTAL ANALYSIS  PRACTICAL 213 PHC  HPLC.
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Introduction to Gas Chromatography
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Chromatography- TLC & HPLC
HPLC Equipment : Detectors
Size Exclusion Chromatography (SEC)
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
Best Broken into four categories
HPLC detectors Pharmawiki 11/18/2018.
High Performance Liquid Chromatography
Application note # QAN-0085 ™ APPLICATION NOTES CHROMATOGRAMS
VAPOUR PHASE CHROMATOGRAPHY
APPLICATION NOTES THE NQAD IS HIGHLY SENSITIVE,
Chromatography Daheeya Alenazi.
High Performance Liquid Chromatography
Liquid Chromatography - Method Development and Validation
Darrell Clinton and H. Dorota Inerowicz Purdue University
Transferring LC-UV to LC-MS.
Presentation transcript:

Evaporative Light Scattering Detector (ELSD) ANALATYCAL CHEMISTRY 427 PHC Done by: Madawi AlUbied Areej Alsuwayyid

Objectives What is Evaporative Light Scattering Detector ? Capabilities how does it work? Characteristic properties Advantages Sensitivity Problems

1. What is Evaporative Light Scattering Detector ? Evaporative Light Scattering Detectors (ELS Detectors) are essentially universal detectors. primarily used in High Performance Liquid Chromatography (HPLC). ELS detectors are an ideal substitute, or supplement to, traditional HPLC detectors for liquid chromatography concentration detection.

2. Capabilities The detector responds to all compounds that are, relative to their mobile phase, sufficiently nonvolatile at the conditions of analysis. ELSD is suitable for all LC separated analyses that does not have light absorbing chromophores. So it dose not rely on optical properties . Ex: phospholipids, carbohydrates, amino acids , fatty acids and synthetic polymers.

3. how does it work? 3 key stages: 2 3 1

Nebulizer uses a stream of inert gas to transform eluent from LC into fine vapor of uniform size droplets

Stage 2: Evaporation  Evaporative tube temperature is controlled to remove solvent from less volatile analyte particles , also the tube has low volume to minimize heat dispersion

Detector has high-efficiency LED light (or short wave length high power laser) to maximize scattering of small analyte particles

4. Characteristic properties Low background noise (no solvent peaks) Reproducibility (in the 1μg range, STD ~ 1%) Low band broadening (short transit time) “Near” linear response (instrument and concentration dependent, smart choice of stand)

5. Advantages No sample preparation No drivatisation Universal - responds to all compounds in the mobile phase Not dependent on spectroscopic properties of analyte Not susceptible to baseline drift during gradient elution, temperature or solvent pump fluctuations ELSD compatible with a much wider range of solvents compared to Refractive Index detector No interference from solvent front peaks (enables fast analysis) Flow rates up to up to 5ml/min can be achieved with no affect on baseline stability Ideal for High Throughput Screening and quantification

The ELSD Improves Baseline Stability and Detection Sensitivity Compared to RI 10278 1. Fructose 2. Glucose 3. Sucrose 10277 Column: Prevail™ Carbohydrate ES, 5µm, 53 x 7mm (Part No. 35104) Mobile Phase: Acetonitrile:Water (75:25) Flowrate: 2.0mL/min RI ELSD

6. Sensitivity Sensitivity with ELSD is limited to 1–50 ng on-column in the best instances. the followings factors are considered to be affect ELSD sensitivity : Gas quality Solvent quality Column contributions Solvent modifiers

7. Problems: arising with an ELSD are usually manifest in a noisy baseline. This can have several causes: Evaporation Temperature too low: the solvent is not completely evaporated. Evaporation Temperature too high: the solvent is boiling in the nebuliser. Air or nitrogen not clean: remove traces of water or oil with a filter. Gas flow too low: poor nebulisation of the eluent. Involatile material in the eluent: replace any buffer salt with a volatile one (such as ammonium acetate) and ensure that the eluent is particle free.

References http://www.usedhplc.co.uk/UsedHPLC- IntroductiontoEvaporativeLightScatteringDetectorsELSD.htm http://www.separationsnow.com/details/ezine/sepspec10174e zine/Exploring-the-alluring-charms-of-a-charged-aerosol- detector-for-HPLC.html?tzcheck=1 http://www.laserchrom.com/LaserchromHPLC- TechnicalSupportCentre-TechnicalTips-IntrotoELSD.htm http://fxg-ent.com/downloads/SoftaELSDBrochure.pdf