Atomic Absorption Spectroscopy Elemental analysis Dissolved metals Source –Hallow Cathode Lamp –Cathode of specific element Sample –Acetylene-air flame,

Slides:



Advertisements
Similar presentations
Chapter 25 Instruments for Optical Spectroscopy
Advertisements

FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Chem. 133 – 4/13 Lecture. Announcements I Exam 2 Results: Ave = 55% (10% below last year’s) Lab: Should finish Set 2 Period 4 lab today Thursday is make-up.
Chapter 7 Components of Optical Instruments
What disperses radiation into component wavelengths?
Lecture 16. LIPS. Introduction a type of atomic emission spectroscopy which uses a highly energetic laser pulse as the excitation source. The laser is.
Elemental Spectroscopy ICP-OES
Atomic Emission Spectroscopy
Atomic Emission Spectroscopy
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
AAS and FES (Ch 9, 7th e, WMDS)
Components of Optical Instruments or What’s inside that spectrometer?
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Spectroscopy Atomic Spectroscopic Methods Covered in Ch 313: Optical Atomic Spectrometry (Ch 8-10) Atomic X-ray Spectrometry (Ch 12) Atomic Mass.
Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.
Analytical Chemistry –Atomic absorption Spectroscopy
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
INSTRUMENTAL ANALYSIS CHEM 4811 CHAPTER 7 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Chem. 133 – 4/1 Lecture. Announcements I Lab –Returning Term Project Proposals (I expect to be getting boxes of supplies ready) –Returning Set 2 Period.
Atomic spectra are a result of energy level diagrams - quantum theory.
Fluorescence. Topics Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-Induced Fluorescence.
Atomic Absorption Spectroscopy (AAS)
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Atomic-Absorption (AA) Spectroscopy 
Instrumental Chemistry
Fluorescence. Topics Definition Instrumentation Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-induced Fluorescence.
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Atomic Absorption Terry A. Ring Chemical Engineering University of Utah.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
Biochemical instrumental analysis-2
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
What is spectroscopy? It is the study of how matter interacts with electromagnetic radiation (gamma rays down to radio waves) Matter can interact with.
5 Components Common to All Optical Spectrometers Source Transparent Sample Holder Wavelength Selector Radiation Detector Signal Processor and Readout.
Chapter 10 Atomic Emission Spectrometry
1.1 Inductively coupled plasma (ICP) Three Argon flow 1.Plasma gas (10-20 L/min) 2.Nebulizer gas (~1L/min) 3.Optional auxiliary gas (~0.5L/min) Radio-frequency.
Atomic Absorption Spectrometry
1 Atomic Emission Spectroscopy Lecture Advantages of Plasma Sources 1.No oxide formation as a result of two factors including Very high temperature.
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
Adv. Inst. Techs.  flame emission (eg flame photometer) known as low temperature emission ( K) ◦ first form of spectroscopy ◦ used in commercial.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Chapter 9 Atomic Absorption and Atomic Fluorescence Spectrometry.
Atomic-absorption spectroscopy
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
A TOMIC - ABSORPTION SPECTROSCOPY. Atomic absorption spectroscopy (AAS) is a technique for determining the concentration of a particular metal element.
What is Atomic Spectroscopy? – Sec Atomic Absorption Spectroscopy (AAS) versus Atomic Emission Spectroscopy (AES)
Atomic-absorption spectroscopy Lab3 Atomic-absorption spectroscopy.
Chapter 10 Atomic Emission Spectrometry
Chem. 133 – 4/12 Lecture. Announcements I Strike – No Strike now planned Exam 2: – Average was 77 (range 61 to 93) Last HW Set (Set 3 – see handout) Lab.
Chemistry 4631 Instrumental Analysis Lecture 18 Chem 4631.
Chem. 133 – 3/29 Lecture. Announcements I Grading – Set 2 lab reports (return?) – Term project proposals (still working on) – UV-Visible seemed to work.
Chapter 28 Atomic Spectroscopy.
Chem. 133 – 3/16 Lecture.
Chem. 133 – 4/4 Lecture.
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY
Flame Emission Spectrometry
Chem. 133 – 3/30 Lecture.
Atomic Absorption and Atomic Fluorescence Spectrometry
The ratio of excited state to ground state atoms as a function of temperature is determined by the Maxwell-Boltzmann expression. Fig Excited state.
Chapter 3. Components of Optical Instruments
Elemental composition
Atomic Absorption and Emission
Atomic Absorption and Atomic Fluorescence Spectrometry
Пламена Спектроскопија
Fluorescence.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

Atomic Absorption Spectroscopy Elemental analysis Dissolved metals Source –Hallow Cathode Lamp –Cathode of specific element Sample –Acetylene-air flame, nebulizer Detector –PMT

Atomic absorption Gas-phase elemental atoms Narrow absorption lines (±0.01 nm) Element specific source Flame conditions control sensitivity ppm (mg/L) varies with element

Hollow cathode lamp PMT Flame sample nebulizer Air Acetylene Coating of element AA Spectrometer monochrometer

Experiment Aspirate blank, set 100 % T Aspirate sample Matrix effects are common –Standard addition analysis

Standard Addition Analysis

Removal of Atomic Emission Place a chopper before the flame The signal from the source is modulated by the chopper Thus, a AC signal is produced on top of a DC signal that originates from emission in the flame

Atomic Emission Spectroscopy Emission of light from exited species ICP source Multi-element analysis –Fancy optics Greater sensitivity for most elements

ICP source Ar tourch –Very hot, K –Abundance of e- inhibits ionization –Lack of O 2 inhibits oxide formation –Excited atomic species predominate –5-20 L/min

Sample Introduction Nebulizer Electrothermal vaporization Laser ablation In either case Ar gas in used to carry sample into the ICP

Scanning Instruments Grating monochromator Slew-scan mode –Slew-The detector and slit is quickly moved to a specific wavelength for a given element –Slowly scan across the wavelength window near a line in very small steps nm –Not limited to a set of specific elements Echelle grating/prism –Higher orders, 2-D plane, better dispersion –Slew-scan mode

Diffraction Equation n = d(sin i + sin r) Dispersion D = dy/d = F (n/d cos r)

Multi-channel Instruments Polychromators –60 photomultipliers in fixed positions Array-based –Echelle and prism for 2-D dispersion plane –Charge injection detector with different detector elements (8.7x6.6mm) –A set of 39 elements makes up a read window for a given element –CCD detectors

CCD detectors Array of semiconductor detection elements 512x320 array = individual detectors Charge of impinging photons are stored The charge accumulated on each detector element is registered one by one by sending the charge to a preamplifier and readout (emptying the registrar) Very sensitive

Fig 10-6 and Fig is the slew can instrument 10-7 is the multi-channel instrument

Performance Sensitivity: Ranges from ng/mL Number of useful lines; 1-24 Calibration curves; almost 3 orders of magnitude Internal standards Self-absorption at higher concentrations

Other components of visible spectroscopy Photon Counting –Each time a photon strikes the PMT, a pulse of electrons are produced –Normally, an average current over time is integrated to produce the signal –In photon counting each pulse is counted, and the total number of pulses in a time interval is summed –Filters out noise –Fluorescence and Raman Spec

Fiber Optics Total Internal Reflections n 1 >n 2 >n 3

Lasers Qualities –High intensities –Narrow band width –coherence Lasing medium –Solid state, gas, dye Lasing mechanism –Figure 7.5