NON DESTRUCTIVE CHEMICAL ANALYSIS

Slides:



Advertisements
Similar presentations
Instrumental Chemistry
Advertisements

X-ray Detection and Analysis
Bragg’s Law nl=2dsinΘ Just needs some satisfaction!! d Θ l
Lecture 11. Microscopy. Optical or light microscopy involves passing visible light transmitted through or reflected from the sample through a single or.
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
Olin Student Projects 2007 Keith Gendreau NASA/GSFC
Internal – External Order We described symmetry of crystal habit (32 point groups) We also looked at internal ordering of atoms in 3-D structure (230 space.
X-Ray Crystallography The most important technique for mineralogy The most important technique for mineralogy Direct measurement of atomic arrangement.
PROVIDED BY EMAD BEHDAD SPECIALIZED PROTECTION AND CORROSION OF MATERIALS LECTURERS H.MONAJATI,PHD JAFARI,PHD ISLAMIC AZAD UNIVERSITY OF NAJAFABAD BARANCH.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
E nergy D ispersive X -ray Fluorescence Spectrometer E nergy D ispersive X -ray Fluorescence Spectrometer EDX-720 Training.
Emre Ertuğrul Emin Şahin Seçkin Gökçe KMU 396 Material Science and Technology.
X Ray Flouresence Analysis (XRF). XRF X-Ray Fluorescence is used to identify and measure the concentration of elements in a sample X-Ray Fluorescence.
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
ED and WD X-ray Analysis
FT-IR Instrument. Components Source Michelson Interferometer Sample Detector.
Qualitative, quantitative analysis and “standardless” analysis NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
Lecture 3 INFRARED SPECTROMETRY
Mass Spectroscopy 1Dr. Nikhat Siddiqi. Mass spectrometry is a powerful analytical technique that is used to identify unknown compounds, to quantify known.
BY SANTANU PRAMANIK(09369) HITESH KUMAR GUPTA(09320) CHANDAN SINGH(09260) SCANNING ELECTRON MICROSCOPE MATERIAL SCIENCE ASSIGNMENT.
Corpuscular induced and X-ray or γ -ray induced fluorescence NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
Field Methods XRF Copyright © 2013 by DBS. Atomic Spectroscopy for Metal Analysis Introduction to the Principles of Atomic Spectroscopy Atomic spectroscopy:
Thin film or complex multi-layer plating Thickness Measurement application Other customer interesting elements analysis application # Dae-Ryung Techno.
X-Ray Fluorescence Analysis by Gergana Hristozova Project supervisor: s. eng. M. Gustova FLNR.
Seminar Author: Bojan Hiti Mentor: doc. dr. Matjaž Kavčič Determination of trace impurities on Si wafers with x-ray fluorescence.
Workshop PET/SPECT/RADIO-ISOTOPES in Greece 26 June 2006 The XRF method: Development and Applications Ch. Zarkadas and A.G. Karydas N.C.S.R. “Demokritos”,
Total X-ray Fluorescence Spectroscopy (TXRF) Contact: World Agroforestry Centre (ICRAF), P.O. Box Nairobi, Kenya. Tel:
X - Rays & Crystals Characterizing Mineral Chemistry & Structure J.D. Price Characterizing Mineral Chemistry & Structure J.D. Price.
Atomic Emission Spectroscopy
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
1 Lecture: Solid State Chemistry (Festkörperchemie) Part 2 (Further spectroscopical methods, ) H.J. Deiseroth, SS 2004.
Chapter 12 Atomic X-Ray Spectroscopy
EDS Energy Dispersive Spectroscopy
Unknown at first, these photons from innershell transitions have played a vital role in materials analysis.
Chem X-ray Crystallography X-ray crystallography is an experimental technique that exploits the fact that X-rays are diffracted by the periodic.
Electron Microscopes Used to count individual atoms What can electron microscopes tell us? Morphology – Size and shape Topography – Surface features (roughness,
1 Atomic Emission Spectroscopy Lecture Advantages of Plasma Sources 1.No oxide formation as a result of two factors including Very high temperature.
Scanning Electron Microscope (SEM)
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
NANO 225 Micro/NanoFabrication Electron Microscopes 1.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
Reminders for this week Homework #4 Due Wednesday (5/20) Lithography Lab Due Thursday (5/21) Quiz #3 on Thursday (5/21) – In Classroom –Covers Lithography,
Spectrophotometry.
Lecture 27-1 Thin-Film Interference-Cont’d Path length difference: (Assume near-normal incidence.) destructive constructive where ray-one got a phase change.
Scanning capacitance microscopy
NANO 225 Intro to Nano/Microfabrication
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
SEM Scanning Electron Microscope
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
X-ray Microanalysis An inelastic collision between a primary beam electron and an inner orbital electron results in the emission of that electron from.
X-ray microanalysis in the electron microscope
Example of the output produced by XRF
Characterization of Nanomaterials 1- Scanning Electron Microscopy (SEM) It is one of the most widely used techniques in the characterization of the morphology,
Tube Exposure Factors Math Technique Contrast and Density
Do it with electrons !. Microscopy Structure determines properties We have discussed crystal structure (x-ray diffraction) But consider now different.
EBB 245. Materials Characterisation Lecture 3 X-ray Fluorescence Spectrometry (XRF) Dr Zainovia Lockman PPKBSM, USM (lecture presentations/notes.
Presentation on SEM (Scanning of Electron Microscope) Represented by:-Ravi Kumar Roll:- (BT/ME/1601/006)
UV/VIS SPECTROSCOPY.
Electron microprobe in Askja
X-ray spectroscopy Repetition, exercises and more
Computed Tomography Data Acquisition
Acknowledgements Slides and animations were made by Dr. Jon Karty Mass Spectrometry Facility Indiana University, Bloomington.
Instrument Parameters in WDXRF
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
Nanocharacterization (II)
Operating environment:
Presentation transcript:

NON DESTRUCTIVE CHEMICAL ANALYSIS Wavelength dispersive (WDXRF) and energy dispersive (EDXRF) X- ray fluorescence Notes by: Dr Ivan Gržetić, professor University of Belgrade – Faculty of Chemistry

XRF detection system No mater how the secondary X-ray radiation (X-Ray fluorescence) is produced in XRF machines there are TWO WAYS to detect this radiation: Wavelength Dispersive System (WDS) and Energy Dispersive System (EDS).

Wavelength Dispersive System (WDS)

PRINCIPLE A wavelength dispersive detection system physically separates the X-Rays according to their wavelengths. The x-rays are directed to a crystal, which diffracts (according to Bragg´s Law) the X-Rays in different directions according to their wavelengths (energies).

Bragg´s Law

Geometry of the spectrometer SPOT SOURCE of X-RAYS No need for collimators Good for SEM-WDX

Geometry of the spectrometer SURFACE AS A SOURCE of X-RAYS Collimators necessary Good for WD-XRF

Characteristics and Strengths WDS is used for non-destructive quantitative analyses of spots as small as a few micrometers, at detection levels as low as a few 10s of ppm, and for elements from atomic number 5 (boron) and higher. WDS works well in a variety of natural and synthetic solid materials, including minerals, glasses, tooth enamel, semi- conductors, ceramics, metals, etc. The high spatial resolution of WDS not only allows quantitative analyses to be performed on small phases but also to detect chemical zoning on a small scale within a material (e.g. mineral). When the electron beam is restored, the WD spectrometers can allow x-ray image maps of individual elements to be constructed. When compared to EDS, WDS exhibits superior peak resolution of elements and sensitivity of trace elements.

Characteristics and Limitations Because WDS cannot determine elements below atomic number 5 (boron), several geologically important elements cannot be measured with WDS (e.g., H, Li, and Be). Despite the improved spectral resolution of elemental peaks, some peaks exhibit significant overlaps that result in analytical challenges (e.g., VKα and TiKβ). WDS technique is slower then EDS technique, but WDS DL is much better then EDS DL. WDS analyses are not able to distinguish among the valence states of elements (e.g. Fe2+ vs. Fe3+) such that this information must be obtained by other techniques (e.g. Mossbauer spectroscopy). The multiple masses of an element (i.e. isotopes) cannot be determined by WDS, but rather are most commonly obtained with a mass spectrometer (see stable and radiogenic isotope techniques).

Detection limit for WDS The range of detectable elements varies according to instrument configuration and set up, but typically WDXRF covers all elements from beryllium (Be) to uranium (U). Concentrations can range from 100% down to ppm and in some cases sub-ppm levels. Limits of detection depend upon the specific element and the sample matrix, but as a general rule, heavier elements will have better detection limits.

Energy Dispersive System (EDS)

PRINCIPLE EDS is an analytical technique used for the elemental analysis or chemical characterization of a sample. The secondary x-rays (X-ray florescence) are directed to a detector. A detector is used to convert X-ray energy into voltage signals; this information is sent to a pulse processor, which measures the energy of the signals and passes them onto an analyzer. The analyzer converts the analog into a digital signal which is proportional to the energy of the incoming pulse. Received pulses are actually amplified, converted into digital signals and then sorted by energy with help of multi-channel analyzer (energy is characteristic for each element) and frequency of appearance (characteristic for concentration) and sent to data display and analysis. The most common detector now is Si(Li) detector cooled to cryogenic temperatures with liquid nitrogen; however newer systems are often equipped with silicon drift detectors (SDD) with Peltier cooling systems.

EDS spectrometer ED-XRF SEM-EDX

Si(Li) detector with LN cooling

Si(Li) detector with Peltier cooling

Detection limit for EDXRF Analysis of elements from Sodium (Na) to Uranium (U). Concentration range from 100 % down to the ppm-level (not valid for light elements). Limits of detection depend upon the specific element and the sample matrix, but as a general rule, heavier elements will have better detection limits.

HANDHELD XRF Specifically designed for the rigorous demands of nondestructive elemental analysis in the field.

Detection limit for handheld EDXRF

μ-XRF with polycapillary focusing optics Polycapillary focusing optics collect a large solid angle of X rays from an X-ray source and focus them to a spot as small as 10µm. The X-ray flux density obtained is a few orders of magnitude higher (100x-10000x) than that obtained with a conventional pinhole collimator. The main application of these optics is micro X-ray fluorescence (µXRF) analysis, which has been widely used for thin film and plating analysis, precious metal evaluation, alloy measurement, and monitoring of electric circuit board coatings. Polycapillary optics are arrays of small hollow glass tubes (fibers). X rays are guided down these curved and tapered tubes by multiple reflections in a manner analogous to the way fiber optics guide light.

μ-XRF with polycapillary focusing optics

WDS vs EDS

Differences in WDS and EDS

Differences in WDS and EDS 1. High spectral resolution (2-6 eV) 1. Low spectral resolution (130-155 eV) 2. Low collection efficiency (slower) 2. High collection efficiency (faster) 3. Higher P/B 3. Lower P/B 4. Highly sensitive to geometric effects 4. Low sensitivity to sample geometry 5. Few spectral artifacts 5. Several spectral artifacts 6. No LN required 6. LN required* 7. Moving mechanical parts 7. No moving mechanical parts** 8. Relatively high beam current typical 8. Lower beam current feasible 9. Great for majors and traces 9. Great for majors, poor for traces 10. Very expensive to purchase 11. Less expensive to purchase * Some recent claims of LN-free new models ** Except for retractable models

WDS vs EDS spectrum

SEM-WDS vs WD-XRF SEM-WDS WD-XRF Corpuscular (electron) induced X-rays Wave (X-rays or γ-rays) induced X-rays NECESSARY for nonconductive samples surface coating with electro conductive thin film (carbon, gold…) No coating necessary Spot, line or surface analysis (scanning system) Mainly surface analysis (spot in case of μ-XRF) Small excitation energy 0,06 W !! (up to 2 μA beam current, up to 30 kV excitation potential) High excitation energies up to 4 kW (up to 120 mA beam current, up to 80 kV excitation potential) Excellent energy resolution Analysis of surface layers (shallow penetration up to 2 μm) Analysis of dipper layers – real bulk analysis (penetration up to 3mm) Longer time for quali- and quanti-tative analysis Good detection limit Excellent detection limit Analysis of elements from Beryllium (Be) to Uranium (U) Concentration range from 100 % down to the ppm-level. Concentration range from 100 % down to the sub-ppm-level. Manual to semiautomatic procedures Possible full automatic procedures

SEM-EDS vs ED-XRF SEM-EDS ED-XRF Corpuscular (electron) induced X-rays Wave (X-rays or γ-rays) induced X-rays NECESSARY for nonconductive samples surface coating with electro conductive thin film (carbon, gold…) No coating necessary Spot, line or surface analysis (scanning system) Mainly surface analysis (spot in case of μ-XRF) Can work only with vacuum Vacuum not necessary but it can work with vacuum Small excitation energy 0,06 W !! (up to 2 μA beam current, up to 30 kV excitation potential) High excitation energies up to 4 kW (up to 120 mA beam current, up to 80 kV excitation potential) Fair energy resolution Analysis of surface layers (shallow penetration up to 2 μm) Analysis of dipper layers – real bulk analysis (penetration up to 3mm) Short time for quali- and quanti-tative analysis Good detection limit. Less optimal for light elements. Good detection limit in vacuum. Less optimal for light elements. Analysis of elements from Sodium (Na) to Uranium (U) Concentration range from 100 % down to the ppm-level (not valid for light elements). Concentration range from 100 % down to the 10 or 100 ppm-level with no vacuum. Analysis of solid samples Analysis of solids and liquids Manual to semiautomatic procedures Possible full automatic procedures HANDHELD instruments available

THE END