Team BUSS Backup Storage Source. Team BUSS Idaho Power Company Backup Storage Source Project Title Extra High Voltage (EHV) Station Second DC Storage.

Slides:



Advertisements
Similar presentations
POWER QUALITY BACKGROUND & ELEC-SAVER TVSS
Advertisements

B757 Review Questions.
Electrical Systems Chapter 9.
Battery Backup/ Uninterruptible Power Systems Reliable Power-----Is important to effectively maintain signal controls and communications for life and safety.
So you decided, you want to change to Solar Power, but you dont really know how it works... No Problem.
1. Four LLs were published in February Transmission Relaying – Undesired Blocking 2.Lack of Separation for Critical Control Power Supply Leads.
1 POWER QUALITY -- Bhanu Bhushan -- June, How close is the supply voltage waveform to sinusoidal, and how close are the supply voltage and frequency.
Automotive Batteries.
CP1610: Introduction to Computer Components Computer Power Supplies.
Goshen Area Bus Reconfiguration
ERIC VANDENBURG, SPENCER HOMAN, TREVOR LARSON and NIK URLAUB Team website: / 1.
Rooftop Solar Systems Rooftop Solar System (Off-Grid) Reliance Solar Energy™, Ratnagiri.
Reliability of present dc system is high, but could increase if a redundant battery or a redundant battery system were put in parallel with present system.
April 15 and May 15, 2003 ERCOT System Disturbances ERCOT TAC Meeting June 4, 2003.
ERIC VANDENBURG, SPENCER HOMAN, and TREVOR LARSON Team website: 1.
ERIC VANDENBURG, SPENCER HOMAN, TREVOR LARSON and NIK URLAUB Team website: / 1.
1 Team BUSS Backup Storage Source. 2 Team BUSS Backup Storage Source EHV Substation Second DC Storage Source Sponsor Idaho Power Company Team Members.
Electrical Power Systems Chapter 8 Mill Creek High School G. Burrows.
1 Team BUSS Backup Storage Source. 2 Team BUSS Backup Storage Source EHV Substation Second DC Storage Source Sponsor Idaho Power Company Team Members.
Borah Mitigators Remedial Action Scheme for the Borah West Path Sponsored by: IDAHO POWER Team Members: Kyle Jones Mark Magee Jason Rippee.
Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level.
Shipboard Electrical Distribution …“Shifting the Electric Plant to a Normal Full Power Lineup.”
Chapter 1 Aircraft Electrical System. Chapter 1 Aircraft Electrical system Electrical component Storage Battery DC & AC Generator Control and Protection.
SUBSTATION MODELING: PROTECTION AND AUTOMATION
Freedom Combi Inverter
The First Central Emergency & Standby Lighting System Combining Storage Batteries & Generator Input 1 1.
Solar PV Design Implementation O& M March 31- April 11, 2008 Marshall Islands 2. Solar Home Systems (SHS) 2. Solar Home Systems (SHS) Herb Wade PPA Consultant.
THE ELECTRIC SUB STATION
Lesson 9: Electrical Components
Generating and Using Electricity
Performance modeling of a hybrid Diesel generator-Battery hybrid system Central University of Technology Energy Postgraduate Conference 2013.
1 Power Quality Mary Santori, P.E. Senior Engineer September 12, 2013.
Shore Station UPS Requirements for the NEPTUNE Power System
BLACKOUT POWER OUTAGE By Masih Madayeni Class 3/6 English Presentation.
Electrical Power Systems
POWER SYSTEM PROTECTION. Power system Generators Transformers Transmission lines »Underground cables »Overhead lines Distribution systems.
1 INTRUSION ALARM TECHNOLOGY POWER SUPPLIES. 2 INTRUSION ALARM TECHNOLOGY Security systems shall have a primary power source and a secondary power source.
Need for protection Power system must be kept in operation continuously without major breakdowns This can be achieved in two ways: 1.Implement a system.
Current Electricity - Symbols Draw the symbol for each electrical device.
4S-1 Chapter 4S Reliability –The ability of a product, part, or system to perform its intended function under a prescribed set of conditions –Reliability.
1 POWER QUALITY -- Bhanu Bhushan -- April, Simple examples around us : Ceiling fan regulators Tube lights Lap-tops & peripherals Domestic inverters.
PowerSouth Lowman AC/DC Essential Voltage System.
Summary Rich Bauer, Senior Reliability Engineer Event Analysis Subcommittee – LL Update March 04, 2014.
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
ADT490 Panel Theory. 2 System Power Supply Grounding ‣ Circuit separates positive / negative from Ground ‣ Ground fault - resistance to ground ≤ 10 kΩ.
Utility Engineers, PC.  Generation  Transmission  Distribution.
Direct & Alternating Currents Gr 9 Science. Direct Current (DC) The current from a cell is called direct current because charged particles travel through.
A Presentation On 132 KV GSS BEHROR
C-12 ELECTRICAL CW3 RIESE 18 APRIL DC SYSTEM -24V, 34 AMP HOUR NICKEL CAD BATTERY A 30V DC STARTER/GENERATORS -AN EXTERNAL DC POWER SYSTEM.
A Training Presentation On 132 KV GSS JAIPUR Submitted in partial fulfillment For the award of the degree of BACHELOR OF TECHNOLOGY Submitted To:- Submitted.
PHY 202 (Blum)1 More basic electricity Non-Ideal meters, Kirchhoff’s rules, Power, Power supplies.
Unit 13 Electric Circuits
Avoid _____________ _____________ _____________ _____________ _____________ _____________.
6 Mains Electricity Alternating current. 6.1 Alternating Current Direct current (d.c.) involves the flow of electrons in one direction normally from batteries.
IP d.c. devices © Oxford University Press 2011 d.c. devices.
Copyright© 2005 Avaya Inc. All rights reserved Avaya UPS Training powerware.com/avaya.
Uninterruptible Power Supply Improves Reliability at The Australian Synchrotron Sean Murphy – ARW 2013 Melbourne.
IEA INTERNATIONAL ENERGY AGENCY PHOTOVOLTAIC POWER SYSTEMS PROGRAMME Overview 1.Introduction / Summary 2.PV-diesel hybrid systems 3.Measurement equipment.
April 7, 2015 Washington, D.C. Area Low-Voltage Event Operations Training Seminar 2016 Erik Johnson System Operations Training (ERCOT)
© 2004 Eaton Corporation. All rights reserved. Online Training: Advanced Battery Management.
Equipment 1.Circuit Breaker. 3.Fuses. 4.Protecti- ve relay.2.Bus bar. TYPES OF SWITCH GEAR EQUIPMENT:-
 The figure below shows a protection system for a transmission line, consisting of a CT, PT, a relay and its associated circuit breaker.
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
Grid Operations Update
Show Video:
Kurt Uhlir President Standby Power System Consultants, Inc.
Reduction in Downtime via Interlocking
Chapter 7 System Protection
Acadiana Load Pocket Project
Components inverters Except where otherwise noted these materials are licensed Creative Commons Attribution 4.0 (CC BY)
Presentation transcript:

Team BUSS Backup Storage Source

Team BUSS Idaho Power Company Backup Storage Source Project Title Extra High Voltage (EHV) Station Second DC Storage Source Sponsor

Team BUSS Team Members Rob Butzer Mitch Colburn Brian Vandenburg Backup Storage Source

Team BUSS Project Background EHV Substations: Midpoint 500kV substation AC power being run through a transformer DC power running the relays, indication lamps and breakers Backup Storage Source

Team BUSS Project Background DC System of a Substation: DC power supplied by rectified AC power under normal conditions DC power also charges the battery for the occurrence of an ac power outage Backup Storage Source

Team BUSS Backup Storage Source

Team BUSS Project Background DC Battery: Bank of up to 60 batteries Each battery rated at about 2.3V Backup Storage Source

Team BUSS Project Background When ac power is lost: Battery backup activated to keep relays online, up to 8 hours Battery used to trip breakers, re- energize the system This trip may occur up to 8 hours after the loss of ac power Backup Storage Source

Team BUSS Importance If loss of dc system:  Can result in a blackout if loss of protection elements  Can damage equipment at substations  Can lose information stored in relays Backup Storage Source

Team BUSS Project Deliverables 1. Reliability of DC battery system 2. Alternatives for backup dc storage supply 3. Implementation of recommended storage source on Model Power System Backup Storage Source

Team BUSS Problems: Presently, backup battery system is a single point of failure within the power system On the east coast, it is required to have duel battery backup system in any substation over 230kV Backup Storage Source

Team BUSS Failures: Idaho Power has always been able to re-energize its system A charger went off line, and voltage levels fell, and charger was replaced A cracked lid on a jar caused extensive smoke to issue from battery bank, but still able to trip the breakers Backup Storage Source

Team BUSS Reliability Fault Tree Analysis Each component of the dc system has a failure rate associated with it When reliability is calculated, take the reliability found and multiply by the number of components to find out how many failures will occur per year Backup Storage Source

Team BUSS Reliability Fault Tree Analysis Backup Storage Source 300 devices * = 6.36 failures/year

Team BUSS Midpoint Battery Specifications: Continuous load after power is lost draws 4.0 A. This must be held for 8 hours Momentary load of A to be supplied at the end of the 8 hour System voltage of 130V Backup Storage Source

Team BUSS Basis for Evaluation of Alternatives: 1. Reliability 2. Cost -Initial cost, maintenance costs, etc. Backup Storage Source

Team BUSS AlternativesUltracapacitors DC generator set Fuel Cells Duel Battery Backup Backup Storage Source

Team BUSS Backup Storage Source

Team BUSS Questions? Backup Storage Source