Absorber cryo and safety design MUCOOL – MICE meeting Del Allspach / PPD Christine Darve / BD Arkadiy Klebaner / BD Alexander Martinez / BD Barry Norris.

Slides:



Advertisements
Similar presentations
1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
Advertisements

The Use of Small Coolers for Hydrogen and Helium Liquefaction
Pressure Vessel Safety Calculation Takeyasu Ito Los Alamos National Laboratory EDM Collaboration Meeting Durham, NC May 20-21, 2008.
1 Cooling the Hydrogen (Helium) Absorbers with Small Coolers Michael A. Green University of Oxford Department of Physics Oxford OX1 3RH, UK MICE Video.
Liquefied Natural Gas Fuel tank
February 17-18, 2010 R&D ERL Roberto Than R&D ERL Cryogenics Roberto Than February 17-18, 2010 CRYOGENICS.
Progress on the MICE Cooling Channel Solenoid Magnet System
Status of T2K Target 2 nd Oxford-Princeton High-Power Target Workshop 6-7 th November 2008 Mike Fitton RAL.
Proposal for Convection Absorber Test with Hydrogen at Fermilab Barry Norris Representing colleagues in BD/Cryogenics February 21, 2003.
1 Update on Focus Coil Design and Configuration M. A. Green, G. Barr, W. Lau, R. S. Senanayake, and S. Q. Yang University of Oxford Department of Physics.
MICE AFCSWG Safety Review Summary Mary Anne Cummings Dec. 17, 2003 MICE Video Conference.
MuCool Absorber Review meeting FermiLab, Chicago 21 – 22 February 2003 Fluid Flow and Convective Heat Transfer Modelling by Wing Lau & Stephanie Yang Oxford.
Absorber/vacuum windows and absorber assembly 1.Window Requirements 2.MICE experimental constraints 3.Welded vs. non-welded windows 4.Installation 5.Testing.
MTA Cryostat & cooling loop design Christine Darve Fermilab/Beams Division/ Cryogenic Department/ Engineering and Design Group Preparation of the Mucool/MICE.
Cryogenic Facility for Mucool at Linac MUCOOL – MICE meeting Barry Norris, Engineer, Beams Division/Cryogenic Dept. Fermilab phone:
LH2 Absorber Design Mary Anne Cummings MICE Safety Review LBL Dec 9, 2003.
MICE Hydrogen System Implementation Tom Bradshaw Elwyn Baynham Iouri Ivaniouchenkov Jim Rochford.
March 14, 2003 MICE Absorber/Coil Integration MICE LH2 Absorber 1.Assembly 2.Safety 3.Staging 4.Instrumentation.
Fermi National Accelerator Laboratory FERMILAB CRYOGENIC STATUS Beams Division Cryogenics Barry Norris (overseer) Alex Martinez (helium cryo) Christine.
LH2 Absorber Design Mary Anne Cummings MICE Safety Review LBL Dec 9, 2003.
1 Absorber Heat Transfer and Other Issues A Comparison between MICE and the Forced Flow Absorber System Michael A. Green Lawrence Berkeley National Laboratory.
Mucool cryo-design Christine Darve Fermilab/Beams Division/ Cryogenic Department 8/12/02.
MICE Hydrogen System Design Tom Bradshaw Iouri Ivaniouchenkov Elwyn Baynham Columbia Meeting June 2003.
Mucool Test Area Cryostat & cooling-loop design Christine Darve Fermilab/Beams Division/ Cryogenic Department/ Engineering and Design Group MuCool / MICE.
Current status Arkadiy Klebaner November 21, 2012
CASIPP Design of Cryogenic Distribution System for CFETR CS model coil Division of Cryogenic Engineering and Technical Institute of Plasma Physics Chinese.
Fcal upgrade for sLHC: Cryogenics modifications – TE-CRG/ C.Fabre 1 ATLAS FCal Upgrade for sLHC: Modifications to the Calorimeter Cryogenic.
Cooling: CEDAR PMT & Electronics Tim Jones Liverpool Group.
23 Jan 2007 LASA Cryogenics Global Group 1 ILC Cryomodule piping L. Tavian for the cryogenics global group.
R&D Status and Plan on The Cryostat N. Ohuchi, K. Tsuchiya, A. Terashima, H. Hisamatsu, M. Masuzawa, T. Okamura, H. Hayano 1.STF-Cryostat Design 2.Construction.
CD-03/12/06 – IIT NFMCC meeting Flow Absorber Possibilities C. Darve Fermi National Accelerator Laboratory Batavia, IL, 60500, USA Neutrino Factory & Muon.
MTA Cryogenics: Where We Are The Work of Fermilab AD/Cryo Barry Norris, Christine Darve and a host of wonderfully talented Cryogenic Personnel John Thompson,
Utilities 14 October 2008 Martin Nordby, Gordon Bowden.
Hydrogen system R&D. R&D programme – general points Hydrogen absorber system incorporates 2 novel aspects Hydrogen storage using a hydride bed Hydrogen.
Conceptual Design Review of the NPDGamma Experiment in Beam Line 13 Seppo Penttila NPDGamma project manager September 25, 2007 at SNS.
CRYOGENICS FOR MLC Cryogenic Piping in the Module Eric Smith External Review of MLC October 03, October 2012Cryogenics for MLC1.
ERL: G-5/e-Gun Cryogenic & Pressure Safety Committee Review ERL G-5/e-gun Beam Line Vacuum Failure Analysis April 24, 2009.
Consideration of Baffle cooling scheme
CMS FPIX Cooling System Studies Joe Howell, Fermilab for the FPIX Upgrade Mechanical Working Group CMS Upgrade Workshop April 27,
PSB dump: proposal of a new design EN – STI technical meeting on Booster dumps Friday 11 May 2012 BE Auditorium Prevessin Alba SARRIÓ MARTÍNEZ.
Hall D Target System Review J. FochtmanSeptember 28,2011 Preliminary Design Work.
9/17/07IRENG071 Cryogenic System for the ILC IR Magnets QD0 and QF1 K. C. Wu - BNL.
MICE LH2 Absorber Safety Mary Anne Cummings Edgar Black (IIT) Abingdon, UK Oct. 30, 2003.
1 Small Coolers for MICE Michael A. Green University of Oxford Department of Physics Oxford OX1 3RH, UK MICE Collaboration Meeting RAL.
CRYOGENICS FOR MLC Cryogenic Principle of the Module Eric Smith External Review of MLC October 03, October 2012Cryogenics for MLC1.
FCC Week 2015, Washington Cooling the FCC beam screens
The integration of 420 m detectors into the LHC
Cryogenic scheme, pipes and valves dimensions U.Wagner CERN TE-CRG.
Date 2007/Sept./12-14 EDR kick-off-meeting Global Design Effort 1 Cryomodule Interface definition N. Ohuchi.
5 K Shield Study of STF Cryomodule (up-dated) Norihito Ohuchi KEK 2008/4/21-251FNAL-SCRF-Meeting.
EXTRACTION OF HIGH VOLUME CRYOGENIC HEAT LOAD
NML Cryogenic System Arkadiy Klebaner Cryomodule One Commissioning June 3, 2011.
CW Cryomodules for Project X Yuriy Orlov, Tom Nicol, and Tom Peterson Cryomodules for Project X, 14 June 2013Page 1.
Comments from the SNS Cryostat Design Review February 2010 Tom Peterson, Fermilab 15 February 2010.
Overview of the ESS Linac Cryogenic Distribution System
ESS Cryomodule Status Meeting – Introduction | | Christine Darve Introduction to Cryomodules for the ESS 2013 January, 9 th Christine Darve.
TDR Cryogenics Parameters Tom Peterson 28 September 2011.
SIS 100 Vacuum chamber Recooler String system Components
NPDG Liquid Hydrogen Target: Design and Safety Features
Status of work (cryostat, control Dewar, cooling system)
Design of the thermosiphon Test Facilities 2nd Thermosiphon Workshop
IT-4189 Supply and installation of a cryogenic distribution system
Cryogenic behavior of the cryogenic system
A. Vande Craen, C. Eymin, M. Moretti, D. Ramos CERN
Small Coolers for MICE MICE Collaboration Meeting RAL Michael A. Green
2K Cold Box Process Design
ESS elliptical cryomodule
SNS PPU Cryomodule Instrumentation
Cryogenic behavior of the magnet
SNS PPU Cryomodule Instrumentation
Presentation transcript:

Absorber cryo and safety design MUCOOL – MICE meeting Del Allspach / PPD Christine Darve / BD Arkadiy Klebaner / BD Alexander Martinez / BD Barry Norris / BD

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Absorber cryo and safety design ZEnvironment of the LH2 absorber test facility (cf Barry’s talk) ZLH2 Absorber system and cryogenic test facility ZSafety and Cryo-design Z Conclusion and further works

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Environment of the test (cf Barry’s talk) ZHelium refrigeration schematic How can we provide the refrigeration power ? => Tevatron cooling system like How much could be provided ? => Up to 500 W at 20 K ZHydrogen refrigeration loop schematic

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Cryo-test during a Tevatron shut-down period Operating parametersfor the test facility: Helium supply Temperature = 17 K Helium supply pressure = 0.25MPa (36 psi) Output temperature Input temperature Efficiency Goal of the test: stability measurement for running at 14 K instead of 5 K

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Hydrogen refrigeration loop schematic W at 20 K 52 times the LH2 volume

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th LH2 Absorber system and cryogenic test facility Components: ZCryostat ZLH2 Absorber ZLH2 pump ZHelium/Hydrogen heat exchanger ZHeat load to the cryostat ZPressure drop

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th LH2 Absorber system and cryogenic test facility Muon beam

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th LH2 Absorber system and cryogenic test facility ZCryostat ZStainless steel vacuum vessel ZThermal shield actively cooled by nitrogen ZSuper insulation (30 layers of MLI on the thermal shield) ZG10 support spider ZPressure safety relief valves ZAbsorber (2 windows + manifold) Z6 liters of LH 2 ZSupporting system (mechanical support, insulation, alignment..) ZSupply and return channels connections

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th LH2 Absorber system and cryogenic test facility R

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th LH2 pump Spare pump from SAMPLE ZReference: “Nuclear Instruments and methods in physics research”, by E.J. Beise et al. Characteristics: ZControlled by AC RT (2 HP) ZCirculating pump (up to 550 g/s) ZExpected pump efficiency~ 50% (cf. SAMPLE test) ZHeat load  (fluid velocity) 3 and Heat load  (pump speed) 3 <100 Watt from the pump and heat leak through the motor shaft

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th LH2 pump

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th E158 LH2 pump Note: Our pump is 1.5 time smaller than the E158 one

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Heat Exchanger The HX is sized to extract up to 1 kW Helium/LH2 co-current flow Helium properties: Thein = 14 K Theout=16.5 K Phe=0.135 MPa (19.6psi) mhe=75 g/s Hydrogen properties: Th2in=17.3 K Th2out=17 K Ph2=0.121 MPa (17.5 psi) mh2=420 g/s

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th The_in Surface HX The_out Length HX vs. dct Phe_in Pressure drop / helium mhe Pressure drop / hydrogen Number of spire vs. DHX Th2in Th2out Velocity of helium in cooling tube Ph2 Velocity of hydrogen in HX mh2 Reynolds number / He and H2 Prandtl number / He and H2 Q Nusselt number / He and H2 dct Convection coeff / He and H2 th DHX Wall temp. on He and H2 side Number of iteration i Qconduction Qconvection on He and H2 side H2 cooling capacity He cooling capacity Heat Exchanger Hepak& Gaspak  _h2(T)  _h2(T) K_h2 (T) Cp_h2 (T) h_h2(T)  _he(T)  _he(T) K_he (T) Cp_he (T) h_he(T) To compared with Q Cal. for each T. iteration Helium parameters Hydrogen parameters Geometric parameters

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Heat Exchanger zSolution Inner diam. cooling tube = 0.623”=15.8 mm Thickness = 0.032”=0.81 mm Outer Shell diameter = 6”= mm Length including the heater = 20”= 508 mm 1.Surface of the heat exchange = m 2 2.Length for dcthe = “ (15.82 mm), Le= 7.22 m 3.If DHX=4.5 “ and dct = “ than, Nr = 22 spires and Le2=7.46 m 4.Pressure drop on the LH2 side, droph2= 2.1E-3 psi 5.Pressure drop in Helium side, drophe= 3.9 psi

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Heat load from ambient to absorber temperature level The refrigeration power will be distributed between the beam load and the static heat load z zDetermination of the heat load to the Absorber z zConduction through the G10 support (VV  TS  Abs) z zRadiation and Conduction in residual gas, MLI (VV  TS  Abs) z zRadiation (windows  Abs)

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Heat load from ambient to absorber temperature level Heat transfer by conduction through the G10 support Heat transfer by radiation and through MLI Legend: Cryostat vacuum 300 K 300 K Cryostat Thermal 80 K +30 layers of MLI 20 K 0 W 67 W 6 W 0 W 1.5 W (39 W if no MLI) 0.2 W 0.3 W N2 Cooling line HeGeneral refrigeration system 48 W 17 W Safety factor =2 Cryostat windows +1 layer of MLI W

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Pressure drop in the LH2 loop Z1D analysis of the total pressure drop at the pump inlet and outlet ZHydrogen mass flow: 550 g/s ZPressure/temperature of Hydrogen: 1.7b/17K Absorber flow circuit: Supply: 13 nozzles Return: 19 nozzles

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Pressure drop Map of the pressure drop: Delta-P (10 -3 psi) C/C: The total Pressure drop through the system is 52.5*10 -3 psi (356 Pa)

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Safety and Cryo-design The design of the LH2 absorber cryo system must meet the requirements of the report “Guidelines for the Design, Fabrication, Testing, Installation and Operation of LH2 Targets – 20 May 1997” by Del Allspach Test facility LH2 Absorber ZAluminum 6061 T6 and series 300 Stainless-steel ZDesign for a MAWP of 25 psid.. ZPSRV sized to relieve at 10 psig (25 psid) Vacuum vessel ZAluminum 6061 T6 and series 300 Stainless-steel ZStress analysis for mechanical and thermal loads ZDesign for a MAWP of at least 15 psig internal ZPSRV sized to relieve less than 15 psig (30 psia)

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Safety and Cryo-design The Pressure safety valves Sized for the cases of Hydrogen boil-off in vacuum failure (no fire consideration) zLH2 loop => Two pressure relieve valves (Anderson Greenwood type) located before and after the LH2 pump zVacuum vessel => two parallel plates and a check valve in series with a safety controlled valve Comments ZElectrical risk– Follow guidelines – NEC Requirements for H2 ZSecond containment vessel avoided if possible. ZHydrogen vent

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Vacuum vessel - Cryostat window thickness zParameters that influence the mechanical choice of the window: yPressure (value, direction) => 2 Configurations yShape yMaterial yDiameter zPressure configurations Case A) two windows to be separated by the atmosphere Beam pipe vacuum----wind#1----atm----wind#2----Cryostat vacuum =>P=15 psid twice the thickness Case B) one window in between both vacuums Beam pipe vacuum----wind#1----Cryostat vacuum =>P=30 psid

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th y x Vacuum vessel - Cryostat window thickness zShape The maximum allowable stress in the window should be the smaller of: Su x 0.4 or Sy x 2/3 Flat plate Torispherical Finite element analysis =>

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Vacuum vessel - Cryostat window thickness zMaterials (need exact material physical properties) zDiameter Even if the muon beam diameter can vary along the cooling channel, the first containment window should keep the same diameter  D= 22 cm (8.66”) MaterialsE (GPa/10 6 psi)Ultimate stress (MPa/ksi)Yield stress (MPa/ksi) Titanium – Ti / / /107.0 Aluminum – 6061 T668.0/ / /40.9 Beryllium – S-200E251.0/ / /43.2

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Cryostat window thickness – Potential solutions 22-cm window MaterialsW/ Atmosphere interface 2 windows, 15 psid W/o Atmosphere interface 1 window, 30 psid Titanium – Ti Aluminum – 6061 T Beryllium – S-200E Flat plate thickness (mm) Torispherical thickness (mm) MaterialsW/ Atmosphere interface 2 windows, 15 psid W/o Atmosphere interface 1 window, 30 psid Aluminum – 6061 T

Cryogenic Dept. Absorber cryo. and safety design Ch. Darve - 02/06/02MUCOOL/MICE meeting –February 5 th to 8 th Conclusions The feasibility of the LH2 Absorber cryo. system has been studied, conceptual designs are proposed. Safety issues still need to be finalized. üPreparation of the safety documentation / Safety Hazard Analysis üCommittee and review More results can be found at: