COST286 meeting Barcelona 14/15 April BUTE Part 1 Conducted and radiated disturbance regulations for PLC devices János Löcher; György Varjú BUTE BUTE Part 2 Site Trial using the low voltage feeder of RBS sited on HV power line tower EPFL Part 3 Mitigation of electromagnetic field radiated by PLC systems (in indoor environment) EPFL
COST286 meeting Barcelona 14/15 April BUTE Part 1 Conducted and radiated disturbance regulations for PLC devices
COST286 meeting Barcelona 14/15 April IEC Signaling on low voltage electrical installations No radiated interference limits apply below 30 MHz Limits of mains terminal interference voltage
COST286 meeting Barcelona 14/15 April CLC/prTS50437:2004 Draft Technical Specification for electromagnetic emissions fromaccess powerline communications networks Limits of conducted common mode (asymmetric mode) disturbances at network cables Limits of radiated disturbances from networks cables
COST286 meeting Barcelona 14/15 April ITU-T K.60 Emission limits and test methods for telecommunication networks Limits for unwanted disturbance emissions from telecommunication networks No conducted interference limits apply
COST286 meeting Barcelona 14/15 April H-field limits converted to E-field using the far field correction of 51.5 dB
COST286 meeting Barcelona 14/15 April BUTE Part 2 Site Trial using the low voltage feeder of RBS sited on HV power line tower
COST286 meeting Barcelona 14/15 April Site Trial using the low voltage feeder of RBS sited on HV power line tower
COST286 meeting Barcelona 14/15 April HE Modem Signal injection Radiated field metering Measuring concept 3 phase Low Voltage feeder PVC insulated phase conductors wounded around a bare neutral
COST286 meeting Barcelona 14/15 April Coupling PLT HE: (capacitive, inductive) - one, two or three phase to neutral - phase to phase - any other combination PLT Modem: (only capacitive) - only phase to neutral Used frequency Upstream:13.8 – 16.3 MHz (512 carrier) Downstream:19 – 22.8 MHz (768 carrier) Injected signal level max. 30 dBm Data transfer rate Downstream:max. 27 Mbps Upstream:max. 18 Mbps System overview
COST286 meeting Barcelona 14/15 April Characteristics to be measured K-factor measurement - H-field - Noise floor - Injected signal Ingression Noise LCL, TCL measurement - CM current Attenuation characteristics measurement Assessment of a technique to mitigate electromagnetic radiation from PLC Note: Regarding the measuring procedures, see: (JTA) “EMC analysis of LF unstructured telecom networks”
COST286 meeting Barcelona 14/15 April EPFL Part 3 Mitigation of electromagnetic field radiated by PLC systems (in indoor environment)
COST286 meeting Barcelona 14/15 April Mitigation of emissions V comp + - I comp - + V PLC I PLC E PLC =V PLC h PLC (f) h PLC (f) E comp =V comp h comp (f) h comp (f) V comp h comp (f)= -V PLC h PLC (f) ? V comp =-V PLC h PLC (f) h comp (f) Injection of an auxiliary compensation signal)
COST286 meeting Barcelona 14/15 April Classical Coupling of PLC Signals
COST286 meeting Barcelona 14/15 April Antenna mode and TL mode Currents
COST286 meeting Barcelona 14/15 April Mitigation u Idea: inject an auxiliary signal S 2 into the line formed by the ground and the neutral conductors u The auxiliary signal S 2 has the same amplitude and waveshape as the original PLC signal S 1, but with opposite polarity
COST286 meeting Barcelona 14/15 April Proposed Coupling: Power Splitter
COST286 meeting Barcelona 14/15 April Bidirectional Data Transmission
COST286 meeting Barcelona 14/15 April Test Configurations
COST286 meeting Barcelona 14/15 April Measurements
COST286 meeting Barcelona 14/15 April Measurement Results