Allowed and Forbidden Transitions Only a fraction of all possible transitions are observed. Allowed transitions -high probability, high intensity, electric.

Slides:



Advertisements
Similar presentations
Lecture 6 ATOMIC SPECTROSCOPY
Advertisements

Atomic Spectroscopy: Atomic Emission Spectroscopy
Atomic Absorption & Emission Spectroscopy
1.1 Atomic Absorption Spectrometry (AAS) determination of elements not compounds needs radiation source high temperature for atomization Atomization a.
Chem. 133 – 4/13 Lecture. Announcements I Exam 2 Results: Ave = 55% (10% below last year’s) Lab: Should finish Set 2 Period 4 lab today Thursday is make-up.
Spectroscopy Lecture 4 Ahmad Razali Bin Ishak Department of Environmental Health Faculty of Health Sciences UiTM Puncak Alam.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
Chapter 10 ATOMIC EMISSION SPECTROMETRY
AAS and FES (Ch 10, 7th e, WMDS)
Atomic Emission Spectroscopy
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Spectroscopy Atomic Spectroscopic Methods Covered in Ch 313: Optical Atomic Spectrometry (Ch 8-10) Atomic X-ray Spectrometry (Ch 12) Atomic Mass.
Atomic Absorption Spectroscopy
INTRODUCTION TO OPTICAL METHODS
Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.
Analytical Chemistry –Atomic absorption Spectroscopy
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Molecular Fluorescence Spectroscopy
Emission Spectroscopy Based upon Plasma, Arc, and Spark Atomization Arc Arc Higher Temperature Higher Temperature Lower interelement interference Lower.
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
announcements and reminders
Atomic Absorption Spectroscopy (AAS)
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
Atomic spectra are a result of energy level diagrams - quantum theory.
AES: Figures of Merit Linearity over 4 to 5Linearity over 4 to 5 concentration decades concentration decades Reasons for deviations Reasons for deviations.
Atomic Absorption Spectroscopy (AAS)
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY Chap 9.
Double-Beam AAS Single-Beam I0 Double-Beam Isample
C – 1s 2 2s 2 2p 2 Step 1:Consider two valence p electrons 1 st 2p electron has n = 2, l = 1, m l = 0, ±1, m s = ±½ → 6 possible sets of quantum numbers.
To calculate the energy of a single electron atom with quantum numbers L, S, and J: E L,S,J = ½ hc [J(J+1) - L(L+1) – S(S+1)] where  is the spin-orbit.
Allowed and Forbidden Transitions Only a fraction of all possible transitions are observed. Allowed transitions -high probability, high intensity, electric.
Atomic Absorption Spectroscopy
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Chapter 8 An Introduction to Optical Atomic Spectroscopy
Biochemical instrumental analysis-2
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
1.1 Inductively coupled plasma (ICP) Three Argon flow 1.Plasma gas (10-20 L/min) 2.Nebulizer gas (~1L/min) 3.Optional auxiliary gas (~0.5L/min) Radio-frequency.
Atomic Absorption Spectroscopy
Atomic Absorption Spectrometry
AAS Atomic Absorption Spectrophotometry. AAS – Widely in clinical laboratories to measure elements such as aluminum, calcium, copper, lead, lithium, magnesium,
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
1 Introduction to Atomic Spectroscopy Atomic Absorption Spectroscopy Lecture 12.
Adv. Inst. Techs.  flame emission (eg flame photometer) known as low temperature emission ( K) ◦ first form of spectroscopy ◦ used in commercial.
Beers Law for a Single Component Sample I0I0 A = Absorbance = - log 10 I I / I 0 b = Optical path length c = Solution Concentration (M/L) ε = Molar Absorptivity.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Atomic-absorption spectroscopy
1 Atomic Emission Spectroscopy Molecular Absorption Spectroscopy Lecture 21.
Plasma A Plasma consists of a collection of free-moving electrons and ions and is very hot. Energy must be continually applied to sustain the plasma.
A TOMIC - ABSORPTION SPECTROSCOPY Lab no. 3 Done by : Iman Al Ajeyan.
Chem. 133 – 4/4 Lecture. Announcements I Strike – If the strike occurs, it will affect classes April 14 th and 18 th (unless ended early) – Lab: would.
Chem. 133 – 4/12 Lecture. Announcements I Strike – No Strike now planned Exam 2: – Average was 77 (range 61 to 93) Last HW Set (Set 3 – see handout) Lab.
Chemistry 4631 Instrumental Analysis Lecture 18 Chem 4631.
Chapter 28 Atomic Spectroscopy.
Chem. 133 – 4/4 Lecture.
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY
Flame Emission Spectrometry
Chem. 133 – 3/30 Lecture.
Atomic Absorption and Atomic Fluorescence Spectrometry
The ratio of excited state to ground state atoms as a function of temperature is determined by the Maxwell-Boltzmann expression. Fig Excited state.
Elemental composition
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
Inductively Coupled Plasma
Presentation transcript:

Allowed and Forbidden Transitions Only a fraction of all possible transitions are observed. Allowed transitions -high probability, high intensity, electric dipole interaction Forbidden transitions -low probability, weak intensity, non-electric dipole interaction Selection rules for allowed transitions: * The parity of the upper and lower level must be different. (The parity is even if  l i is even. The parity is odd if  l i is odd.) * l = ±1 *  l = ±1 *  J = 0 or ±1, but J = 0 to J = 0 is forbidden.

Additional Splitting Effects Hyperfine splitting due to magnetic coupling of spin and orbital motion of electrons with the nuclear spin.Hyperfine splitting due to magnetic coupling of spin and orbital motion of electrons with the nuclear spin. Isotope shift. Sufficient to determine isotope ratios.Isotope shift. Sufficient to determine isotope ratios. Splitting in an electric field (Stark effect): Relevant for arc and spark techniques.Splitting in an electric field (Stark effect): Relevant for arc and spark techniques. Splitting in a magnetic field (Zeeman effect):Splitting in a magnetic field (Zeeman effect): * In absence of a magnetic field, states that differ only by their M J values are degenerate, i.e., they have equivalent energies. * In presence of a magnetic field, this is not true anymore. * Can be used for background correction.

Pretsch/Buhlmann/Affolter/Badertscher, Structure Determination of Organic Compounds

Pretsch/Buhlmann/Affolter/Badertscher, Structure Determination of Organic Compounds

Stark Splitting For H: split  E For others: split  (E) 2

Zeeman Splitting Ingle and Crouch, Spectrochemical Analysis M J – Resultant total magnetic quantum number M J = J, J-1, …, -J 2J +1 possible values NormalAnomalous

Sample Introduction and Atomization Atomization: Atomization: Convert solution → vapor-phase free atoms Measurements usually made in hot gas or enclosed furnace: flamesflames plasmasplasmas electrical discharges (arcs, sparks)electrical discharges (arcs, sparks) heated furnacesheated furnaces Free Atoms IonsIons Mole- cules Nebulization Desolvation Volitalization Adapted from Ingle and Crouch

Atomic Emission Spectroscopy (AES) See also: Fundamental reviews in Analytical Chemistry e.g. Bings, N. H.; Bogaerts, A.; Broekaert, J. A. C. Anal. Chem. 2002, 74, (“Atomic Spectroscopy”) e.g. Bings, N. H.; Bogaerts, A.; Broekaert, J. A. C. Anal. Chem. 2002, 74, (“Atomic Spectroscopy”) Beginning 19th century: alcohol flame (Brewster, Herschel, Talbot, Foucault) Beginning 19th century: alcohol flame (Brewster, Herschel, Talbot, Foucault) mid 1800s: Discovery of Cs, Tl, In, Ga by atomic spectroscopy (Bunsen, Kirchhoff) mid 1800s: Discovery of Cs, Tl, In, Ga by atomic spectroscopy (Bunsen, Kirchhoff) 1877: Gouy designs pneumatic nebulizer 1877: Gouy designs pneumatic nebulizer 1920s: Arcs and sparks used for AES 1920s: Arcs and sparks used for AES 1930s: First commercial AES spectrometer (Siemens-Zeiss) 1930s: First commercial AES spectrometer (Siemens-Zeiss) 1960s: Plasma sources (commercial in 1970s) 1960s: Plasma sources (commercial in 1970s)

Atomic Emission Spectroscopy (AES) 2 S 1/2 2 D 3/2, 5/2 2 P 3/2 2 P 1/2 2 S 1/2 At RT, nearly all electrons in 3s orbital Excite with flame, electric arc, or spark Common electronic transitions

Example AE Spectra H2H2H2H2 Hg He

An Ideal AES Source 1. complete atomization of all elements 2. controllable excitation energy 3. sufficient excitation energy to excite all elements 4. inert chemical environment 5. no background 6. accepts solutions, gases, or solids 7. tolerant to various solution conditions and solvents 8. simultaneous multi-element analysis 9. reproducible atomization and excitation conditions 10. accurate and precise analytical results 11. inexpensive to maintain 12. ease of operation

Flame AES Background signals due to flame fuel and oxidants – line spectra:Background signals due to flame fuel and oxidants – line spectra: OH 281.1, 306.4, nmOH 281.1, 306.4, nm from O + H 2 H + OH from O + H 2  H + OH H + O 2 O + OH H + O 2  O + OH O 2 250, 400 nmO 2 250, 400 nm CH 431.5, 390.0, nmCH 431.5, 390.0, nm CO bands between 205 to 245 nmCO bands between 205 to 245 nm CN, C 2, CH, NH bands between 300 to 700 nmCN, C 2, CH, NH bands between 300 to 700 nm Unlike bands of atomic origin, these molecular bands are fairly broad. Unlike bands of atomic origin, these molecular bands are fairly broad. Continuum emission from recombination reactionsContinuum emission from recombination reactions e.g. H + OH H 2 O + h  CO + O CO 2 + h e.g. H + OH  H 2 O + h  CO + O  CO 2 + h Flames used in AES nowadays only for few elements. Cheap but limited. {Flame AES often replaced by flame AAS.}  Flames used in AES nowadays only for few elements. Cheap but limited. {Flame AES often replaced by flame AAS.} Ingle and Crouch

Inductively Coupled Plasma AES Spectral interference more likely for plasma than for flame due to larger population of energetically higher states.Spectral interference more likely for plasma than for flame due to larger population of energetically higher states. Modern ICP power: 1–5 kW (4 to 50 MHz)Modern ICP power: 1–5 kW (4 to 50 MHz) 4000 to 10,000 K: Very few molecules4000 to 10,000 K: Very few molecules Long residence time (2–3 ms)Long residence time (2–3 ms) results in high desolvation results in high desolvation and volatilization rate and volatilization rate High electron density suppressesHigh electron density suppresses ionization interference effects ionization interference effects Background: Ar atomic lines and,Background: Ar atomic lines and, in hottest plasma region, in hottest plasma region, Bremsstrahlung (continuum radiation Bremsstrahlung (continuum radiation from slowing of charged particles) from slowing of charged particles) Price > $ 50 kPrice > $ 50 k Operating cost relatively high dueOperating cost relatively high due to Ar cost (10–15 mL/min) and to Ar cost (10–15 mL/min) and training. training. Ingle and Crouch

Microwave Plasma AES Power 25 to 1000 W (ICP 1000–2000 W)Power 25 to 1000 W (ICP 1000–2000 W) Frequency 2450 MHz (ICP 4 to 50 MHz)Frequency 2450 MHz (ICP 4 to 50 MHz) Argon, helium or nitrogenArgon, helium or nitrogen Temperature estimated to be KTemperature estimated to be K Low temperature causes problems with liquidsLow temperature causes problems with liquids Useful for gases: GC–microwave plasma AESUseful for gases: GC–microwave plasma AES

Arcs and Sparks Arc = An electrical discharge between two or more conducting electrodes (1-30 A)Arc = An electrical discharge between two or more conducting electrodes (1-30 A) Spark = An intermittent high-voltage discharge (few  sec)Spark = An intermittent high-voltage discharge (few  sec) Limited to qualitative and semi-quantitative use (arc flicker)Limited to qualitative and semi-quantitative use (arc flicker) Particularly useful for solid samples (pressed into electrode)Particularly useful for solid samples (pressed into electrode) The burn takes > 20 sec (need multichannel detector)The burn takes > 20 sec (need multichannel detector) Ingle and Crouch

AES: Figures of Merit Linearity over 4 to 5Linearity over 4 to 5 concentration decades concentration decades Reasons for deviations Reasons for deviations from linearity: from linearity: - Self-absorption - Extent of ionization affected by sample affected by sample - Flow rate - Atomization efficiency Ingle and Crouch

AES: Figures of Merit Linearity over 4 to 5 concentration decadesLinearity over 4 to 5 concentration decades Precision: Typically a few % (lower in calibration solutions)Precision: Typically a few % (lower in calibration solutions) Limited by stability of source and random electrical noise Accuracy: An optimized spectrometer should be capable of precision-limited accuracyAccuracy: An optimized spectrometer should be capable of precision-limited accuracy Limited in ICP AES by spectral overlap Applicability: 3/4 of all elements (ICP)Applicability: 3/4 of all elements (ICP) Limitations in detection limits: * Major transitions in UVLimitations in detection limits: * Major transitions in UV * Temperature too high for alkali metals (ion emission in UV as they have fully occupied electron shells)

Detection Limits for Flame AES Ingle and Crouch, Spectrochemical Analysis

Detection Limits for ICP AES Ingle and Crouch, Spectrochemical Analysis

AES: Instrumental Aspects Ingle and Crouch, Spectrochemical Analysis

Atomic Absorption Spectroscopy (AAS) See also: Fundamental reviews in Analytical Chemistry e.g. Bings, N. H.; Bogaerts, A.; Broekaert, J. A. C. Anal. Chem. 2002, 74, (“Atomic Spectroscopy”) e.g. Bings, N. H.; Bogaerts, A.; Broekaert, J. A. C. Anal. Chem. 2002, 74, (“Atomic Spectroscopy”) 1802 Wollaston observes absorption lines in solar spectrum 1802 Wollaston observes absorption lines in solar spectrum 1914 Hollow cathode lamp 1914 Hollow cathode lamp 1955 Walsh describes analytical AAS 1955 Walsh describes analytical AAS st Commercial Flame AAS st Commercial Flame AAS 1960s L’vov and Massman describe graphite furnace 1960s L’vov and Massman describe graphite furnace (commercial in 1970s) (commercial in 1970s) Recall: A = -log 10 (T)

Hollow Cathode Lamp Kellner et al., Analytical Chemistry Typical primary source of radiation: Hollow cathode lampTypical primary source of radiation: Hollow cathode lamp * Typically one lamp per element * Different intensities for different elements * Multielement lamps for multielement analysis Continuum sources (e.g. Xe arc lamp) only for multielement analysisContinuum sources (e.g. Xe arc lamp) only for multielement analysis

Flame AAS Ingle and Crouch, Spectrochemical Analysis Kellner et al., Analytical Chemistry At <5000 K most atoms are predominantly in their electronic ground state. Slot burners with 5-10 cm path lengths.

Ingle and Crouch, Spectrochemical Analysis Electrothermal Atomization Heating current of several hundred AHeating current of several hundred A Heating rates of up to 1000 °C/sHeating rates of up to 1000 °C/s LOD 100 times lower than flame AASLOD 100 times lower than flame AAS Heated in three stages:

Typical furnace material: GraphiteTypical furnace material: Graphite Graphite Furnace AAS  Graphite Furnace AAS * Graphite tube mm * Samples uL * 200 to 1000 cycles * Temperature up to 3000 °C to avoid graphite decomposition * Carbon may be reducing agent for metal ions * Argon flow avoids oxidation Other furnace materials: Ta, W, PtOther furnace materials: Ta, W, Pt * High melting point required * Should not emit brightly at high temperature (disadvantage for W and Ta) and Ta) Electrothermal Atomization

Are you getting the concept? Is ICP a good source for AAS?