Page 1 © 1990-2004 J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT BMS 602/631 - LECTURE 8 Flow Cytometry: Theory J. Paul Robinson Professor.

Slides:



Advertisements
Similar presentations
Chem. 133 – 2/12 Lecture. Announcements Lab Work –Supposed to Cover Set 2 Labs – but I probably won’t cover all and then will give an extra day for period.
Advertisements

© J.Paul Robinson, Purdue University BMS 631 – LECTURE00007.PPT BMS LECTURE 7 Flow Cytometry: Theory Optics - Filter Properties & manipulation.
What disperses radiation into component wavelengths?
Page 1 © J.Paul Robinson - Purdue University Cytometry Laboratories BMS 631 – LECTURE 8 Flow Cytometry: Theory J.Paul Robinson Professor of Immunopharmacology.
Spring 2005ISAT 253 Transducers and Sensors I Friday, March 18, 2005.
Measurement of Light: Applications ISAT 300 Foundations of Instrumentation and Measurement D. J. Lawrence Spring 1999.
Semiconductor Light Detectors ISAT 300 Foundations of Instrumentation and Measurement D. J. Lawrence Spring 1999.
Page 1 © J.Paul Robinson, Purdue University BMS 602 LECTURE 9.PPT BMS LECTURE 10x Flow Cytometry: Theory Bindley Bioscience Center Purdue.
Page 1 © J. Paul Robinson, Purdue University BMS 602/631 - LECTURE 8 Flow Cytometry: Theory Purdue University Office: Fax
1 Chapter 5 Sensors and Detectors A detector is typically the first stage of a communication system. Noise in this stage may have significant effects on.
Page 1 © J.Paul Robinson, Purdue University Cytometry Laboratories BMS 602 LECTURE 9.PPT BMS LECTURE 9 Flow Cytometry: Theory Hansen Hall,
06/02/2008CCDs1 Charge Coupled Device M.Umar Javed M.Umar Javed.
The WEB version of these slides can be found on
Page 1 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT BMS LECTURE 7 Flow Cytometry: Theory J. Paul Robinson Professor of.
Fiber-Optic Communications
Photomultiplier Tube m = k 8–19 dynodes (9-10 is most common).
1 Detectors RIT Course Number Lecture Single Element Detectors.
Transducers Converts one type of energy into another. Light  Electrical (current, voltage, etc.) What characteristics should we look for in a transducer?
Main detector types Scintillation Detector Spectrum.
BMS 602/631 - LECTURE 9 Flow Cytometry: Theory
Photomultiplier Tube. What is it? Extremely sensitive detector of light in the ultraviolet, visible and near infrared Multiplies the signal produced by.
Basics of Flow Cytometry Holden Maecker. Outline Definitions, what can be measured by flow cytometry Fluidics: Sheath and sample streams, flow cells,
OPTICAL DETECTORS IN FIBER OPTIC RECEIVERS.
DC Analysis Representation of diode into three models Ideal case – model 1 with V  = 0 Piecewise linear model 2 with V  has a given value Piecewise linear.
Copyright © Hamamatsu Photonics K.K. All Rights Reserved. Oct at NNN07 Workshop Hamamatsu Photonics Electron Tube Division Recent Progress in PMTs.
CUÑADO, Jeaneth T. GEQUINTO, Leah Jane P. MANGARING, Meleria S.
4/11/2006BAE Application of photodiodes A brief overview.
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
What is spectroscopy? It is the study of how matter interacts with electromagnetic radiation (gamma rays down to radio waves) Matter can interact with.
Photon detection Visible or near-visible wavelengths
Latest developments in Hamamatsu Large Format PMTs
3/26/2003BAE of 10 Application of photodiodes A brief overview.
Venugopala Rao Dept of CSE SSE, Mukka Electronic Circuits 10CS32.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze: Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS Detection.
H.-G. Moser Max-Planck-Institut for Physics, Munich CALOR 06 Chicago June 5-9, 2006 Silicon Photomultiplier, a new device for low light level photon detection.
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
Abort Gap Monitoring Randy Thurman-Keup 6 / 8 / 2004 LARP Meeting.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
Photodetectors What is photodetector (PD)? Photodetector properties
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Chem. 133 – 2/11 Lecture. Announcements Lab today –Will cover 4 (of 8) set 2 labs (remainder covered on Tuesday) –Period 1 will extend one day Website/Homework.
Ideal Detector Fast Cheap Rugged Responds to all wavelengths of light Can distinguish different wavelengths Sensitive Low LOD.
S.S.GaO. Outline Introduction Experiment Results and discussion Conclusion References.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
CUÑADO, Jeaneth T. GEQUINTO, Leah Jane P. MANGARING, Meleria S.
Development of Multi-Pixel Photon Counters (1)
Application of photodiodes
بسم الله الرحمن الرحیم.
Flowcytometry.
BMS 631 – LECTURE 8 Flow Cytometry: Theory
FINAL YEAR PROJECT 4SSCZ
IMAGE ORTHICON.
PAN-2013: Radiation detectors
Chem. 133 – 2/9 Lecture.
BMS 602/631 - LECTURE 7 Flow Cytometry: Theory
Spectral Flow Cytometry
Department of Physics and Astronomy,
Scintillation Counter
Recent Progress in Large Format PMTs
Oct 10, 2018 Muhammad Qasim Abdul Wali Khan University, Department of Physics, Mardan, Pakistan by.
Optical measurement.
BMS 602/631 - LECTURE 7 Flow Cytometry: Theory
Recall-Lecture 6 Diode AC equivalent circuit – small signal analysis
Photomultiplier (PMT) Tubes
Noise I Abigail Firme.
Presentation transcript:

Page 1 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT BMS 602/631 - LECTURE 8 Flow Cytometry: Theory J. Paul Robinson Professor of Immunopharmacology& Biomedical Engineering Purdue University Hansen Hall, B050 Purdue University Office: Fax WEB Detectors 3 rd Ed. Shapiro th Ed. Shapiro Notes: 1.Material is taken from the course text: Howard M. Shapiro, Practical Flow Cytometry, 3nd edition (1994), Wiley-Liss, New York. 2.RFM =Slides taken from Dr. Robert Murphy 3.MLM – Material taken from Melamed, et al, Flow Cytometry & Sorting, Wiley-Liss, 2 nd Ed.

Page 2 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Detectors Light must be converted from photons into volts to be measured We must select the correct detector system according to how many photons we have available In general, we use photodiodes for forward scatter and absorption and PMTs for fluorescence and side scatter

Page 3 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Silicon photodiodes A silicon photodiode produces current when photons impinge upon it (example are solar cells) Does not require an external power source to operate Peak sensitivity is about 900 nm At 900 nm the responsivity is about 0.5 amperes/watt, at 500 nm it is 0.28 A/W Are usually operated in the photovoltaic mode (no external voltage) (alternative is photoconductive mode with a bias voltage) Have no gain so must have external amps quantum efficiency (  )% = 100 x (electrons out/(photons in)

Page 4 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT PMT Produce current at their anodes when photons impinge upon their light-sensitive cathodes Require external powersource Their gain is as high as 10 7 electrons out per photon in Noise can be generated from thermionic emission of electrons - this is called “dark current” If very low levels of signal are available, PMTs are often cooled to reduce heat effects Spectral response of PMTs is determined by the composition of the photocathode Bi-alkali PMTs have peak sensitivity at 400 nm Multialkali PMTs extend to 750 nm Gallium Arsenide (GaAs) cathodes operate from nm (very costly and have lower gain)

Page 5 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Signal Detection - PMTs CathodeAnode Dynodes Photons in Amplified Signal Out End Window Requires Current on dynodes Is light sensitive Sensitive to specific wavelengths Can be end`(shown) or side window PMTs Secondary emission

Page 6 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Photomultiplier tubes (PMT’s) The PMTs in an Elite. 3 PMTs are shown, the other 2 have been removed to show their positions. A diode detector is used for forward scatter and a PMT for side scatter. The Bio-Rad Bryte cytometer uses PMTs for forward and wide angle light scatter as well as fluorescence

Page 7 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT PMTs High voltage regulation is critical because the relationship between the high voltage and the PMT gain is non-linear (almost logarithmic) PMTs must be shielded from stray light and magnetic fields Room light will destroy a PMT if connected to a power supply There are side-window and end-window PMTs While photodiodes are efficient, they produce too small a signal to be useful for fluorescence

Page 8 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Diode Vs PMT Scatter detectors are frequently diode detectors Back of Elite forward scatter detector showing the preamp Front view of Elite forward scatter detector showing the beam-dump and video camera signal collector (laser beam and sample sheath are superimposed) Sample stream

Page 9 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Types of PMTs Side Window High voltage in Signal out

Page 10 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT PMT in the optical path of an Elite cytometer

Page 11 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT High Voltage on PMTs The voltage on the PMT is applied to the dynodes This increases the “sensitivity” of the PMT A low signal will require higher voltages on the PMT to measure the signal When the voltage is applied, the PMT is very sensitive and if exposed to light will be destroyed Background noise on PMTs is termed “dark noise” PMTs generally have a voltage range from volts Changing the gain on a PMT should be linear over the gain range Changing the voltage on the PMT is NOT a linear function of response

Page 12 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Avalanche Photodiodes (APD’s) Combines the best features of PMTs and photodiodes High quantum efficiency, good gain Gain is (much less than PMTs) Problem with high dark current Image From:

Page 13 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT High through-put flow cytometry Source: Howard Shapiro talk

Page 14 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Multianode PMT – sensitivity and uniformity Hamamatsu 32 Ch PMT Latest PMT

Page 15 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Multianode PMT – gain and spectral filtering Now a simple 4 color cytometer

Page 16 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Principle of Operation US & foreign patents pending

Page 17 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT CCDs Charge Coupled devices (CCD) usually in our video cameras (also called charged transfer devices) light causes accumulation of electric charge in individual elements which release the charge at regular intervals Useful in imaging because they can integrate over time Not fast enough for flow cytometry application in general

Page 18 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Summary…. Photodiodes can operate in two modes - photovoltaic and photoconductive Photodiodes are usually used for scatter Photodiodes are more sensitive than PMTs but because of their low gain, they are not as useful for low level signals (too much noise) PMTs are usually used for fluorescence measurements PMTS are sensitive to different wavelengths according to the construction of the photocathode PMTs are subject to dark current High Voltages are not linear across the entire range

Page 19 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT Lecture Summary (cont) There is a very small time scale for measurements Most fluorescence detectors are PMTs PMTs can be destroyed if they receive a lot of light when powered Standard PMTs do not have good sensitivity over 650 nm – you must use a multi-alkali PMT New versions of Multanode PMTs are now available up to 880nm WEB