ECAL TIMING. 20/04/092 Ratios’ Method Basics Position of pulse maximum parameterized using the ratio of two consecutive samples, i.e., R = A(t)/A(t+1)

Slides:



Advertisements
Similar presentations
INFN Milano, Universita` degli Studi Milano Bicocca Siena IPRD May Testbeam results of the CMS electromagnetic calorimeter Alessio Ghezzi.
Advertisements

ATLAS Tile Calorimeter Performance Henric Wilkens (CERN), on behalf of the ATLAS collaboration.
ECAL Spike Plot Approval ECAL Anomalous Signal Plots Approval Adi Bornheim for ECAL
CMS ECAL Laser Monitoring System Toyoko J. Orimoto, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
1 Scintillating Fibre Cosmic Ray Test Results Malcolm Ellis Imperial College London Monday 29 th March 2004.
CMS Physics Meeting, Dec. 6, Analysis Note on the Validation of the ORCA Simulation of the Endcap Muon CSC Front-end Electronics S. Durkin -- Ohio.
First CMS Results with LHC BeamToyoko Orimoto, Caltech 1 First CMS Results with LHC Beam Toyoko Orimoto California Institute of Technology On behalf of.
ECAL Testbeam Meeting, Rome 28 March 2007 Toyoko Orimoto Adolf Bornheim, Chris Rogan, Yong Yang California Institute of Technology Lastest Results from.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
FMS review, Sep FPD/FMS: calibrations and offline reconstruction Measurements of inclusive  0 production Reconstruction algorithm - clustering.
2011 HV scan SF6 flow-meter accident 2011 Results comparison RPC HV efficiency scan Pigi Paolucci on behalf of RPC collaboration.
Cosmic Rays Data Analysis with CMS-ECAL Mattia Fumagalli (Università di Milano Bicocca) CIAO!
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Intercalibration of the CMS Electromagnetic Calorimeter Using Neutral Pion Decays 1 M. Gataullin (California Institute of Technology) on behalf of the.
CMS ECAL 2006 Test Beams Effort Caltech HEP Seminar Christopher Rogan California Institute of Technology May 1, 2007.
Approved Plots from CMS First Beam Runs 2-October-2008.
W  eν The W->eν analysis is a phi uniformity calibration, and only yields relative calibration constants. This means that all of the α’s in a given eta.
Radiation Damage in the CMS Strips Tracker Christian Barth on behalf of the CMS Tracker Collaboration.
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
ATLAS Liquid Argon Calorimeter Monitoring & Data Quality Jessica Levêque Centre de Physique des Particules de Marseille ATLAS Liquid Argon Calorimeter.
A. Gibson, Toronto; Villa Olmo 2009; ATLAS LAr Commissioning October 5, 2009 Commissioning of the ATLAS Liquid Argon Calorimeter Adam Gibson University.
Point Source Search with 2007 & 2008 data Claudio Bogazzi AWG videconference 03 / 09 / 2010.
Commissioning and Operation of the CMS Tracker analogue optical link system at TIF with CMSSW: R.Bainbridge, A.Dos Santos Assis Jesus, K.A.Gill, V. Radicci.
Calibration of the CMS Electromagnetic Calorimeter with first LHC data
CMS ECAL Laser Monitoring System Christopher S. Rogan, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
Ideas for in-situ calibration for the EMC S.Paganis, K.Loureiro ( Wisconsin ) input from+discussions with T.Carli, F.Djama, G.Unal, D.Zerwas, M.Boonekamp,
Uniformity in ATLAS EM Calo measured in test beams  Constraints on the EM calorimeter constant term  Energy reconstruction  Uniformity results with.
Coseners House Forum on LHC Startup 13th April 2007 David Futyan Imperial College 1 David Futyan Imperial College Calibration of the CMS ECAL Using Vector.
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
08-June-2006 / Mayda M. VelascoCALOR Chicago1 Initial Calibration for the CMS Hadronic Calorimeter Barrel Mayda M. Velasco Northwestern University.
Study of neutrino oscillations with ANTARES J. Brunner.
Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.
Jyly 8, 2009, 3rd open meeting of Belle II collaboration, KEK1 Charles University Prague Zdeněk Doležal for the DEPFET beam test group 3rd Open Meeting.
1 P.Rebecchi (CERN) “Monitoring of radiation damage of PbWO 4 crystals under strong Cs 137  irradiation in GIF-ECAL” “Advanced Technology and Particle.
First CMS Results with LHC Beam
Measurement of the Charge Ratio of Cosmic Muons using CMS Data M. Aldaya, P. García-Abia (CIEMAT-Madrid) On behalf of the CMS Collaboration Sector 10 Sector.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
TTF - ECAL Plenary in CMS week ECAL Stability Contacts: Marc Dejardin, Julie Malcles (laser)
1 DT Local Reconstruction on CRAFT data Plots for approval CMS- Run meeting, 26/6/09 U.Gasparini, INFN & Univ.Padova on behalf of DT community [ n.b.:
Georgios Daskalakis On behalf of the CMS Collaboration ECAL group CALOR 2006 – Chicago,USA June 5-9, 2006 CMS ECAL Calibration Strategy.
The Detector Performance Study for the Barrel Section of the ATLAS Semiconductor Tracker (SCT) with Cosmic Rays Yoshikazu Nagai (Univ. of Tsukuba) For.
H C A L 11 th International Conference on Advanced Technology and Particle Physics Villa Olmo (Como - Italy), October 5 - 9, 2009 THE PERFORMANCE OF THE.
Paolo Rumerio, CERN On behalf of the CMS Electromagnetic Calorimeter Group CALOR 2006 Chicago, June 5 th – 9 th, 2006 Commissioning of the CMS Electromagnetic.
Layer00 Efficiency Studies Stephen Levy, UChicago.
Calibration of the CMS Electromagnetic Calorimeter with LHC collision data Maria Margherita Obertino on behalf of the CMS Collaboration Introduction The.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
Juan Valls - LECC03 Amsterdam 1 Recent System Test Results from the CMS TOB Detector  Introduction  ROD System Test Setup  ROD Electrical and Optical.
Plots of RPC performance G. Cattani, University of Rome “Tor Vergata” & INFN Roma 2 on behalf of ATLAS Muon Collaboration.
Sensitivity of HO to Muons Shashi Dugad for HO group India-CMS Meeting 6-7 Oct
1 Projectile Spectator Detector: Status and Plans A.Ivashkin (INR, Moscow) PSD performance in Be run. Problems and drawbacks. Future steps.
Calibration of the CMS Electromagnetic Calorimeter with LHC collision data Maria Margherita Obertino on behalf of the CMS Collaboration Introduction The.
Noise results from SR1 combined SCT barrel tests Summary of some initial results Alan Barr, UCL Pepe Bernabeu, Valencia.
CMS Status & Commissioning Menu: 1 Recent Progress Commissioning Prior to and After First Beam Commissioning with first LHC Events Outlook Wolfgang Funk.
M.D. Nov 27th 2002M0' workshop1 M0’ linearity study  Contents : Electronic injection Laser injection Beam injection Conclusion.
3/06/06 CALOR 06Alexandre Zabi - Imperial College1 CMS ECAL Performance: Test Beam Results Alexandre Zabi on behalf of the CMS ECAL Group CMS ECAL.
1 Methods of PSD energy calibration. 2 Dependence of energy resolution on many factors Constant term is essential only for energy measurement of single.
Electromangetic calorimeter of CMS: status and performances
The Silicon Drift Detector of the ALICE Experiment
Integration and alignment of ATLAS SCT
DT Local Reconstruction on CRAFT data
CMS-ECAL Front-End monitoring Matteo Marone
CMS ECAL Calibration and Test Beam Results
Instrumentation for Colliding Beam Physics 2017
Update on TB 2007 Xtal Irradiation Studies at H4
BESIII EMC electronics
Plans for checking hadronic energy
Bringing the ATLAS Muon Spectrometer to Life with Cosmic Rays
Resistive Plate Chambers performance with Cosmic Rays
Slope measurements from test-beam irradiations
Presentation transcript:

ECAL TIMING

20/04/092 Ratios’ Method Basics Position of pulse maximum parameterized using the ratio of two consecutive samples, i.e., R = A(t)/A(t+1) R fitted with polynomial function Each ratio provides an independent extraction of pulse maximum position (T MAX ) Final T MAX as weighted (with expected error) average of the different measurements

Ultimate Resolution at Test Beam Use of high energy electrons at test beam Compared two neighboring crystals in the same electron cluster to reduce systematic effects and extract ultimate resolution of the algorithm Single crystal time resolution can be parameterized as a function of effective amplitude 1/A eff 2 = 1/A /A 2 2 Constant term ~0.1ns both for endcap and barrel PLOT: y-axis: time difference spread (sigma of a Gaussian from fit) between two neighboring crystals. x-axis: amplitude over noise (or crystal energy) noise term constant term Endcap

Impact of Time Synch. On Resolution Impact of offline synchronization between different channels verified with test beam electrons Compare two neighboring crystals in the same electron cluster Resolution from the difference of time measurements with and without synchronization of crystals O(1ns) improvement. Optimal hardware synchronization together with offline synchronization crucial to reach ultimate performance in time measurement PLOT. Time difference between two consecutive crystals fitted with a Gaussian After synchronizing (7.5-10) GeV testbeam electrons  =0.75ns  =0.21ns

Linearity and Resolution with Cosmics Check of time measurement linearity using two clusters associated to same muon (top-bottom). Expected time of flight compared with measured time. Compared time measurement between crystals in the same muon cluster. Offline detector synchronization not yet taken into account. Photodetector gain x4 the LHC conditions. Time measurement performance verified with full ECAL barrel detector in CMS using cosmics. Cosmic clusters selection refined associating muon track to cluster position. y-axis: time diff. spread (sigma of a gaussian from fit) between two crystals. x-axis: amplitude over noise (or energy of crystal). y-axis: mean of measured time difference. x-axis: expected time of flight of the muon between the two cluster positions Barrel

+Beam-Beam muons Time measurement is verified with full ECAL detector in CMS using muons from beam splash events. ‘Nominal’ is the expected ECAL readout schema, which reads out the detector based on the assumption of time of flight from the interaction point (0,0,0); ‘nominal’ also includes the plane wave assumption of muons traversing ECAL. Time synchronization is derived from laser pulses which are delivered by fibers of the same length within a module. This produces the structure with a modularity of 4-5  intervals. These measured variations have been used to synchronize the post-splashes data-taking. ECAL Splash Timing, η profiles PLOT: mean of timing for crystals in the same  ring versus  index. Left: beam coming from negative direction. Right: beam coming from positive direction. Reconstructed time after correcting for inter-supermodules phases (red) and the expected ECAL time (blue) are shown.

Time measurement is verified with full ECAL barrel in CMS using muons from beam splash events. ‘Nominal’ is the expected ECAL readout delay which reads out the detector based on an assumed time of flight from the interaction point (0,0,0); ‘nominal’ also includes the plane wave assumption of muons traversing ECAL. Time synchronization is derived from laser pulses which are delivered by fibers of the same length within a module. This produces structure with a modularity of 4-5  intervals. ECAL Splash Timing, η profiles PLOT. y-axis: residuals of timing for crystals in the same  ring with respect to the expected time Red: beam coming from positive direction. Red: beam coming from positive direction.

PLOT. y-axis: mean of timing for crystals with the same FED #. x-axis: FED #. Red: beam coming from negative direction. Black: beam coming from positive direction. Time measurement is verified with full ECAL detector in CMS using muons from beam splash events. Here the variations are shown as a function of the FED number (one FED is a readout unit: a supermodule in EB or a sector in EE). O(2ns) variations are expected from length of the readout lines. EE+ (FED: ) was expected to have larger uncertainty for some towers which were timed with HV off. Also the beam from the positive and negative  side are compared showing a small effect (<0.5ns). These measured variations have been used to synchronize the post-splash data-taking. ECAL Splash Timing, FED profile

Ratio Method PLOT. Spread of the difference of crystal times from the expected time, as a function of amplitude over noise (or energy of crystal). The expected time is taken from the time-of-. flight, assuming that the particles hit the middle of each crystal. Fit vs. Ratios: Beam Splashes in the Barrel

SPLASHES IN EE WITH INTERCALIBRATED CRYSTALS

ECAL Endcaps response to beam splashes Average energy per crystal in the ECAL Endcaps seen during “beam splashes” collected with beams coming from the EE- side (top) and the EE+ side (bottom). Intercalibration constants are applied White regions are crystals masked in the readout Energy modulations are a combination of the energy flow investing CMS and geometry effects. In particular, the lower energy at large radii in the ECAL Endcap downstream to the beam direction is due to the ECAL barrel shield

STABILITY

ECAL response sensitive to variations of: Crystal transparency (under irradiation) Temperature: ∂(LY)/∂T, 1/M(∂M/∂T) ~ -2%/K High voltage: 1/M(∂M/∂V) ~ 3%/V Controls and monitoring: Controlled (temperature, CAEN, dark current measurements) ECAL response monitored and corrected with laser data Required performances: Temperature stability at the few 0.01 o C level HV stability at the 10 mV level Laser monitoring of ECAL response at the 2‰ level Introduction LY: light yield M: APD gain

stability map in the ( ,  ) plane for barrel laser data RMS (%)   Most channels have a measured response stability below the 1‰ A set of reference channels APD ref is used to normalize the event-by-event laser amplitude variations. One reference APD channel is chosen arbitrarily for each laser monitoring module (100 or 200 channels) For each channel and each laser sequence (600 laser events), the average is employed as monitoring variable “Stability” is defined as the RMS over all laser sequences of normalized Stabilities are computed for each channel on a period with stable laser conditions during the CRAFT (from 60 to 100 laser sequences within 300 hours) APD ref is chosen as a reference because of readout problems with PN reference diodes, which are being fixed White regions either lack statistics (2 supermodules not readout).

Mean = 0.3 ‰ RMS = 0.2 ‰ Under stable laser conditions, the ECAL LASER monitoring system is able to monitor the crystal response with a precision < 1‰ This precision is consistent with specifications (2‰) needed to achieve the ECAL design resolution stability for barrel laser data (projection of the previous stability map: one entry per channel) 99.6% of channels with RMS<1‰ 99.9% of channels with RMS<2‰

Reminder: Analysis of ECAL Barrel temperatures using 2 independent set of data One crystal out of 10 is equipped with a thermistor, in close thermal contact. The thermistors are read out by detector control units (DCU) Every supermodule is equipped with 10 precision temperature probes (PTM), 2 mounted on the in/out water outlets, and 8 on the mechanical structures (4 on grid, 4 on thermal screen) Hereafter temperatures from the thermistors and the PTM’s are used to assess stability Nominal sensitivity: PTM sensors: 0.01 °C - DCU measurements: °C Thermistors fine calibration has been computed by comparing DCU measurements to PTM sensors values, using data from temperature controlled COSMIC Stand. EB-16, documented replaced VFEs, channels with missing calibrations have been re-calibrated with the same technique using P5 data.

Map of ECAL Barrel instantaneous temperatures ( °C) as measured by the thermistors located on the APD capsules. In black: 37 missing measurements (broken or not calibrated thermistors). White spots: EB+7 (inactive), 34 thermistors outside range. Temperature spread is within 0.2 °C for 96% of the channels. Thermistors located in ECAL outer borders are on average 0.08 °C warmer. ECAL Barrel temperature map

ECAL Barrel Temperatures time evolution during CRaFT, averaging over all the thermistors and PTM probes: thermistors values (black), PTM9 sensors on input cooling water pipes (purple) PTM1 sensors located on the grid of type 1 modules (red), PTM4 sensors located on the grid of type 4 module (green) ECAL Barrel temperature stability

ECAL Barrel temperature spread during CRaFT Top: ECAL Barrel Temperatures distribution, measured at the APD capsules level (DCU system). The average temperature is ± 0.04 °C, which shows a very good overall temperature stability and homogeneity. In blue, superimposed, are the temperatures belonging to the outer borders of the barrel. The average temperature is 0.09 °C higher than the rest of the Barrel. PTM sensors APD capsules Bottom: ECAL Barrel Temperatures distribution, measured at the SM grid level by the PTM system. The average temperature is 18.1 ± 0.02 °C, in very good agreement with the one measured by the DCU system.

Distribution of temperatures RMSs for each of the ECAL Barrel thermistors during CRaFT (logaritmic scale). Missing thermistors are: the broken/not calibrated (37), few masked during CRaFT (LV problems). Peak average RMS is ± °C. 98% of channels have RMS<0.1 °C. Values in the right-end side tail are channels affected by some read-out problems. APD capsules temperature RMS