Capture Cavity 2 Update Tim Koeth April 3 rd Testing at 4.5K.

Slides:



Advertisements
Similar presentations
E. KAKO (KEK) 2010' July 27 meeting Global Design Effort 1 Low Power RF Tests (3) in S1-G.
Advertisements

Overview of SMTF RF Systems Brian Chase. Overview Scope of RF Systems RF & LLRF Collaboration LLRF Specifications for SMTF Progress So Far Status of progress.
325 MHz RF Cave and SC Spoke Cavity Tests Robyn Madrak – Accelerator Physics Center (APC) for the HINS/Project X Group.
CC2 Input Coupler Introduction, Installation, & Processing Tim Koeth November 16 th, 2005.
Piezo Studies and Temperature Measurements Ruben Carcagno May 11, 2005.
Capture Cavity 1at A0 SIMCON2.1 with MATLAB  closed loop with max gain ( 250 )  RMS amplitude noise ≈ 0.07%  RMS phase Noise ≈ 0.2°  closed.
3.9 GHz Deflecting Mode Cavity Timothy W. Koeth July 12, 2005.
RF Unit Test Facility at NML & CM1 Test Plan Bob Kephart Fermilab IWLC-10 October 20, 2010.
Cost comparison of tuners H. Hayano, KEK AWLC14
ILCTA_NML Progress at Fermilab Jerry Leibfritz September 10, 2007.
Superconducting Accelerating Cryo-Module Tests at DESY International Workshop on Linear Colliders 2010 (ECFA-CLIC-ILC Joint Meeting) Denis Kostin, MHF-SL,
E. KAKO (KEK) 2009' Sept. 30 Albuquerque Global Design Effort 1 Cavity Test Items in S1-G Cryomodule Eiji Kako (KEK, Japan)
E. KAKO (KEK) 2010' Sept. 10 KEK Global Design Effort 1 Lorentz Force Detuning Eiji Kako (KEK, Japan)
Test infrastructure and test programs at KEK-STF Kirk 2013/3/26TTC meeting
KEKB Crab Development K. Hosoyama (KEK) Crab Cavity for HER Crab Cavity for LER Crab Cavity for KEKB History of Crab Cavity R&D Characteristics of Crab.
1 Results from the 'S1-Global' cryomodule tests at KEK (8-cav. and DRFS operation) Shin MICHIZONO (KEK) LOLB-2 (June, 2011) Outline I. 8-cavity installation.
HINS 6-Cavity Test 3 Month Plan Jan 12, Current Schedule 2-3 day shutdown scheduled to start Jan 18 (Wednesday) to upgrade BPM system and reinstall.
Detail discussion of S1 Global at STF H. Hayano (KEK) GDE Mar 3-6, 2008.
STF plan overview H. Hayano, KEK LCPAC 02/25/2005.
XFEL SRF Accelerating Module Prototypes Tests at DESY Fermilab Seminar, July 21st Denis Kostin, MHF-SL, DESY.
Linac R&D Update May 15, L-Band Source Consists of a LLRF system (VME/Epics based), a SNS High Voltage Converter Modulator (on loan), a Thales 2104C.
S.Noguchi (KEK) ILC08 Chicago , Nov . 17, Cavity Package Test in STF STF Phase-1 E. Kako, S. Noguchi, H. Hayano, T. Shishido, M. Sato, K. Watanabe,
E. KAKO (KEK) 2010' Feb. 05 STF Meeting for S1-G Global Design Effort 1 Preparation Status at KEK for S1-Global Eiji Kako (KEK, Japan)
Marc Ross Nick Walker Akira Yamamoto ‘Overhead and Margin’ – an attempt to set standard terminology 10 Sept 2010 Overhead and Margin 1.
1 Plan and Opportunities for Migration and Integration of the Photoinjector into New Muon Lab Mike Church AAC Review - 12/5/06.
Beijing ILC Workshop Global Design Effort 1 High-Gradient Module Test Lutz Lilje.
S1G Experiment Schedule Plan; H. Hayano ILC10 GDE meeting.
LCWS13, November 2013 At the University of Tokyo W.–D. Möller Status of the TTF3 RF Power Coupler.
Harry Carter – LCFOA Meeting 5/1/06 1 LCFOA Technical Briefings: Cryomodules H. Carter Fermilab Technical Division.
ILC FAST TUNER R&D PROGRAM at FNAL Status Report CC2 Piezo Test Preliminary Results Ruben Carcagno (on behalf of the FNAL FAST TUNER Working Group) 4/5/06.
Horizontal Test Stands and CC2 Results Andy Hocker Testing an alternative ILC cavity design at USPAS (Q 0 =2.23E+02)
Test plan for SPL short cryomodule O. Brunner, W. Weingarten WW 1SPL cryo-module meeting 19 October 2010.
Overview and Status of the Fermilab High Intensity Neutrino Source R&D Program Giorgio Apollinari for Bob Webber.
E.Kako (KEK) 2009.Dec. 26 1 S1-Global Cryomodule Overview No connection No beam tube No gate-valve Closed by Blind Flange Gate-valve Pumping system Pumping.
E. KAKO (KEK) 2009' Oct. 26 ILC KEK Global Design Effort 1 Cavity Preparation for S1-Global Eiji Kako (KEK, Japan)
Summary of SCRF Meeting Fermilab, April 21-25, 2008 April 25, 2008 General Summary and Further Plan: 4/21: Cavity: Gradient R&D, performance, diagnostics.
Detail plan of S1-Global H. Hayano (KEK),
Date 2007/Sept./12-14 EDR kick-off-meeting Global Design Effort 1 Cryomodule Interface definition N. Ohuchi.
Overview of long pulse experiments at NML Nikolay Solyak PXIE Program Review January 16-17, PXIE Review, N.Solyak E.Harms, S. Nagaitsev, B. Chase,
Superconducting Accelerating Cryo-Module Tests at DESY TESLA Technology Collaboration (TTC) Meeting, February 28 - March , Milano, Italy Denis Kostin,
LFD and Microphonics Suppression for PIP-II Warren Schappert April 15, 2014.
ILCTA_NML Progress at Fermilab Jerry Leibfritz August 16, 2007.
Microphonics Suppression in SRF cavities for Project X Yuriy Pischalnikov Warren Schappert Project X Collaboration Meeting Berkeley, April 11, 2012.
Thomas Jefferson National Accelerator Facility Page 1 FNAL September 11, 2009 Design Considerations for CW SRF Linacs Claus H. Rode 12 GeV Project Manager.
ILCTA-MDB RF Power Status 4/27/06 Reid 1 ILCTA-MDB Status 1.3 GHz RF Power 3.9 GHz RF Power Meson Detector Building April 27, 2006 [John Reid]
Shuichi NoguchiTTC Meeting at Milano, Injector Cryomodule for cERL at KEK Cavity 2 Prototypes were tested. Input Coupler 2 Couplers were tested.
ESS SC cavities development G. Devanz TTC meeting, march 1st 2011, Milano.
325 MHz Superconducting Spoke Cavity Coupler status. T. Khabiboulline Power Coupler design for Superconducting Spoke cavities. Originally.
LLRF regulation of CC2 operated at 4˚K Gustavo Cancelo for the AD, TD & CD LLRF team.
S1G Experiment Schedule Plan
WP5 Elliptical cavities
Power Couplers, HOM Couplers and Tuners for the XFEL
TTC Topical Workshop - CW SRF, Cornell 12th – 14th June 2013
Tuner system Zhenghui MI 2017/01/17
S1-G Webex meeting Global Design Effort
Mechanical setups Lorentz Force Detuning System Setup
R&D Activity for Field Emission and Vertical EP
Jiyuan Zhai ( IHEP ) TTC Meeting, JLAB, 6 Nov 2012
Jefferson Lab Low Level RF Controls
V. Veshcherevich Cornell University
CW Operation of XFEL Modules
CW accelerating module test progress at DESY
KEK injector cryomodule
SCRF for cw operating XFEL
High gradients in TESLA nine-cell cavities
IHEP ILC Cavity Status Jiyuan Zhai (IHEP)
ILC Cryogenics -- Technical Design Report Planning
TTC meeting, Milano Global Design Effort
Cavity Degradation Experience at S1-Global
SNS-PPU upgrades the existing accelerator structure
Presentation transcript:

Capture Cavity 2 Update Tim Koeth April 3 rd Testing at 4.5K

The CC2 Project Capture Cavity 2 is a high gradient superconducting cavity destined to upgrade the Photoinjector to 40 MeV. This opportunity has been used for FNAL to learn the intricacies of SCRF work as well as to test FNAL facilities. It is a collaborative effort: Tesla 9-Cell 1.3 GHz Cavity: DESY (33MV/m) Slow Tuner: Saclay & FNAL Cryo Vessel: IPN Orsay LLRF: DESY & FNAL Inside FNAL: AD, TD, CD

Calendar Started Nov 2004 Approval for RF on Jan 17 th (2006) RF into Input Coupler Jan 17 th Coupler processing Jan 24 th Cool down Feb 6 th (coupler still problematic) Warm up Feb 16 th More Coupler Processing: Feb - March 2 nd Cool Down March 13 th CC2 Testing: Gradients, Dark Current, LLRF, Piezo & More Warm up to begin 1.8K Installation: March 29th

Understanding Input Coupler We are operating at a bias of V on center conductor.

RF In CC2: Peak Gradient RED = P-trans = gradient YEL = P-reflected BLU = P-forward ~ 28MV/m Driving with a 1.38mSec (~100kW) square RF pulse: “Full Blast” Q-loaded: 4.28 E 6 (any higher in gradient and cavity displays quenching)

RF In CC2: Dark Current GRN = “Up Stream” Faraday Cup YEL = P-Trans = Gradient BLU = “Dn Stream” Faraday Cup Peak Dark Current: 50nAmps A Faraday Cup is installed at both ends of CC2’s beam pipe.

RF In CC2: LLRF Control 15MV/m 85kW Using DESY SimCon3.1 LLRF controller RED = P-Fwd YEL = P-Ref BLU = P-Trans = Gradient

RF In CC2: LLRF Control O’scope persistence set to 30 events: RED = P-Fwd YEL = P-Ref BLU = P-Trans = Gradient LLRF System compensated for frequency changes due to cryogenic pressure fluctuations.

RF In CC2: Piezo Fast Tuner

Vibration Studies The Piezo was used as a vibration sensor. The FFT above shows a dominant mechanical vibration at ~17Hz for this case. A dominant frequency of ~42Hz was observed during an earlier measurement. From Seismometer From Piezo Element

Warm Up to Cool Down ! Warmed up CC2 last Wednesday (3/29) to allow Cryogenics Dept to prepare pumps for 1.8K operation. 1.8K in early May.