Status of MEG Physics Analysis Fabrizio Cei INFN and University of Pisa - Italy BVR PSI, 17 February 2010 17 February 2010 1 Fabrizio Cei.

Slides:



Advertisements
Similar presentations
KLOE GM Capri May 2003 K charged status report DE/Dx development vs PiD (next talk by E.De Lucia) →K e3 studies: initial design of efficiency measurement.
Advertisements

June 9, Tetsuro Sekiguchi, KEK BNL-E949 Collaboration The E949 experiment The analysis The results Conclusions BNL, FNAL, UNM, Stony Brook Univ.
TRACK DICTIONARY (UPDATE) RESOLUTION, EFFICIENCY AND L – R AMBIGUITY SOLUTION Claudio Chiri MEG meeting, 21 Jan 2004.
14 Sept 2004 D.Dedovich Tau041 Measurement of Tau hadronic branching ratios in DELPHI experiment at LEP Dima Dedovich (Dubna) DELPHI Collaboration E.Phys.J.
Status of the MICE SciFi Simulation Edward McKigney Imperial College London.
Off-axis Simulations Peter Litchfield, Minnesota  What has been simulated?  Will the experiment work?  Can we choose a technology based on simulations?
Top Turns Ten March 2 nd, Measurement of the Top Quark Mass The Low Bias Template Method using Lepton + jets events Kevin Black, Meenakshi Narain.
Kevin Black Meenakshi Narain Boston University
Search for B     with SemiExclusive reconstruction C.Cartaro, G. De Nardo, F. Fabozzi, L. Lista Università & INFN - Sezione di Napoli.
MEG 実験 陽電子スペクトロメータの 性能と今後の展望 Yuki Fujii On behalf of the MEG collaboration JPS Hirosaki University 17 th Sep /9/17 日本物理学会@弘前大学 1.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Mar Toshiyuki Iwamoto (ICEPP) JPS 2010 Spring meeting, Okayama University1 MEG 実験による   e  探索 Run2009 東京大学素粒子物理国際研究センター 岩本敏幸 他 MEG コラボレーション.
Coincidence analysis in ANTARES: Potassium-40 and muons  Brief overview of ANTARES experiment  Potassium-40 calibration technique  Adjacent floor coincidences.
18 February 2009DCH Analysis1 MEG DCH Analysis MEG Review Meeting 18 February 2009 W. Molzon For the DCH Analysis Working Group.
Pion test beam from KEK: momentum studies Data provided by Toho group: 2512 beam tracks D. Duchesneau April 27 th 2011 Track  x Track  y Base track positions.
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
Analysis of PSI beam test R.Sawada 09/Feb/2004 MEG collaboration R.Sawada 09/Feb/2004 MEG collaboration
26 Jan, MEG Software Status Framework for MEG MC, Unification of LargePrototype/beam test, Schedule and DC reconstruction MEG Software Group.
17 February 2010DCH Analysis1/22 MEG DCH Analysis MEG Review Meeting 17 February 2010 W. Molzon For the DCH Analysis Working Group.
Kalanand Mishra April 27, Branching Ratio Measurements of Decays D 0  π - π + π 0, D 0  K - K + π 0 Relative to D 0  K - π + π 0 Giampiero Mancinelli,
E. De LuciaNeutral and Charged Kaon Meeting – 7 May 2007 Updates on BR(K +  π + π 0 ) E. De Lucia.
K charged meeting 10/11/03 K tracking efficiency & geometrical acceptance :  K (p K,  K )  We use the tag in the handle emisphere to have in the signal.
Liquid Xenon Calorimeter Analysis R.Sawada on behalf of the MEG LXe analysis group 17/Feb/2009.
Mitglied der Helmholtz-Gemeinschaft Calibration of the COSY-TOF STT & pp Elastic Analysis Sedigheh Jowzaee IKP Group Talk 11 July 2013.
Background Subtraction and Likelihood Method of Analysis: First Attempt Jose Benitez 6/26/2006.
CEA DSM Irfu Reconstruction and analysis of ANTARES 5 line data Niccolò Cottini on behalf of the ANTARES Collaboration XX th Rencontres de Blois 21 / 05.
Search for Electron Neutrino Appearance in MINOS Mhair Orchanian California Institute of Technology On behalf of the MINOS Collaboration DPF 2011 Meeting.
Study of neutrino oscillations with ANTARES J. Brunner.
Measurement of Vus. Recent NA48 results on semileptonic and rare Kaon decays Leandar Litov, CERN On behalf of the NA48 Collaboration.
Preliminary results for the BR(K S  M. Martini and S. Miscetti.
JPS 2003 in Sendai Measurement of spectral function in the decay 1. Motivation ~ Muon Anomalous Magnetic Moment ~ 2. Event selection 3. mass.
PMT Calibration R.Sawada 7/Jan/2007. Time calibration Method was talked at the previous meeting. The problems which was shown before were because I used.
1 M2-M5 Efficiency and Timing checks on 7TeV beam data Alessia, Roberta R.Santacesaria, April 23 rd, Muon Operation
 0 life time analysis updates, preliminary results from Primex experiment 08/13/2007 I.Larin, Hall-B meeting.
4/12/05 -Xiaojian Zhang, 1 UIUC paper review Introduction to Bc Event selection The blind analysis The final result The systematic error.
A High Statistics Study of the Decay M. Fujikawa for the Belle Collaboration Outline 1.Introduction 2.Experiment Belle detector 3.Analysis Event selection.
06/2006I.Larin PrimEx Collaboration meeting  0 analysis.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
Kalanand Mishra June 29, Branching Ratio Measurements of Decays D 0  π - π + π 0, D 0  K - K + π 0 Relative to D 0  K - π + π 0 Giampiero Mancinelli,
Kalanand Mishra February 23, Branching Ratio Measurements of Decays D 0  π - π + π 0, D 0  K - K + π 0 Relative to D 0  K - π + π 0 decay Giampiero.
Giuseppe Ruggiero CERN Straw Chamber WG meeting 07/02/2011 Spectrometer Reconstruction: Pattern recognition and Efficiency 07/02/ G.Ruggiero - Spectrometer.
MEG 実験 2009 液体キセノン検出器の性能 II 西村康宏, 他 MEG コラボレーション 東京大学素粒子物理国際研究セン ター 第 65 回年次大会 岡山大学.
Belle General meeting Measurement of spectral function in the decay 1. Motivation 2. Event selection 3. mass spectrum (unfolding) 4. Evaluation.
Feb. 3, 2007IFC meeting1 Beam test report Ph. Bruel on behalf of the beam test working group Gamma-ray Large Area Space Telescope.
Paolo Massarotti Kaon meeting March 2007  ±  X    X  Time measurement use neutral vertex only in order to obtain a completely independent.
Status of physics analysis Fabrizio Cei On Behalf of the Physics Analysis Group PSI BVR presentation, February 9, /02/2015Fabrizio Cei1.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Pattern recognition with the triplet method Fabrizio Cei INFN & University of Pisa MEG Meeting, Hakata October /10/20131 Fabrizio Cei.
Biagio Di Micco  mass measurement Systematics on   mass measurement Biagio Di Micco.
Biagio Di Micco  mass measurement   mass measurement blessing of the final result Biagio Di Micco.
MEG Experiment Data Analysis: a status report
Status of MEG-I physics analysis
analisys: Systematics checks
Status of AIF analysis Daisuke Kaneko.
techniques and studies
Riunione della CNS1 a Bari
Tracking System at CERN 06 and 07 test beams
Cecilia Voena INFN Roma on behalf of the MEG collaboration
Instrumentation for Colliding Beam Physics 2017
p0 life time analysis: general method, updates and preliminary result
° status report analysis details: overview; “where we are”; plans: before finalizing result.. I.Larin 02/13/2009.
J/   analysis: results for ICHEP
Timing Counter analysis
Problems with the Run4 Preliminary Phi->KK Analysis
Report on p0 decay width: analysis updates
KEK, 阪大RCNPA, 阪大理B, 京大理C, 原研先端研D,
西村美紀(東大) 他 MEGIIコラボレーション 日本物理学会 第73回年次大会(2018年) 東京理科大学(野田キャンパス)
Trigger operation during 2007 run
New Results from the MEG Experiment
° status report analysis details: overview; “where we are”; plans: before finalizing result.. I.Larin 02/13/2009.
Presentation transcript:

Status of MEG Physics Analysis Fabrizio Cei INFN and University of Pisa - Italy BVR PSI, 17 February February Fabrizio Cei

Outline physics analysis of 2008 data Results of physics analysis of 2008 data. Present status of physics analysis Present status of physics analysis: - summary of physics analysis for individual sub-detectors; - observation of radiative decay events in MEG 2009 data; Perspectives for 2009 data analysis Perspectives for 2009 data analysis. 17 February 2010 Fabrizio Cei 2

2008 Data Analysis 17 February 2010 Fabrizio Cei 3

17 February 2010 Fabrizio Cei run:   stopped in target RD Programmed beam shutdowns RD Cooling system repair Air test in COBRA We also took RMD data once/week at reduced beam intensity

17 February 2010 Fabrizio Cei 5 Pre-selection/blinding windows Open files: 16 % events Pre-selection process repeated several times with improving calibrations and algorithms. Final blinding box:  1 ns around zero (timing offset subtracted). Plane (E ,  t) used for pre-selection + reconstructed track with associated TC hit Blinded files: 0.2 % events

17 February 2010 Fabrizio Cei 6 is obtained by generating and reconstructing large samples of f S /f M is obtained by generating and reconstructing large samples of MC events (for signal and Michel) in various configurations to take into account the DCH instabilities TRG = 22: Michel events trigger (only DCH track required) TRG = 0: MEG events trigger Normalization 1) where: 10 7 pre-scaling factor

17 February 2010 Fabrizio Cei 7 Normalization 2) Final Value k = 4.7∙10 11 ± 10% Independent computation k = 4.9∙10 11 ± 10% k = 4.9∙10 11 ± 10% Advantage of this technique: it uses the MEASURED number of Michel positrons instead of the CALCULATED number of stopping muons/second  it is independent of time varying DCH acceptance and efficiency. Result confirmed by computations based on time-averaged acceptance and efficiency. k = 1/”SES” (not exactly a “SES”: not zero bck) 2

17 February 2010 Fabrizio Cei 8 Generalities on analysis Three independent blind-likelihood analyses. RD and accidental event rates in the signal region fitted or estimated a priori by means of side-bands information. estimated a priori by means of side-bands information. Feldman-Cousins method for C.L. determination. Kinematical variables used: - Positron and Gamma Energies; - Positron and Gamma Energies; - Relative timing and relative angle; - Relative timing and relative angle; Likelihood function: N obs = number of observed events Signal PDF RD PDF Accidental BCK PDF

17 February 2010 Fabrizio Cei 9 Analysis: PDF determination 1) Signal: Gamma Energy from  0 (DRS) or MC taking into account resolution (TRG); Positron Energy: 3 gaussian shapes; sigma’s extracted from Michel positron fit; Positron Energy: 3 gaussian shapes; sigma’s extracted from Michel positron fit; Positron-Photon relative angle: toy MC based on experimental angular Positron-Photon relative angle: toy MC based on experimental angular resolutions of positrons and photons; resolutions of positrons and photons; Positron-Photon relative timing: gaussian Positron-Photon relative timing: gaussian shape with sigma = 147 (or 135) ps from shape with sigma = 147 (or 135) ps from radiative decay data fit with Gamma radiative decay data fit with Gamma Energy outside of Blinding Box. Energy outside of Blinding Box. Radiative Decay: Gamma Energy + Positron Energy + Relative Angle e + -  : 3-D distribution based on theoretical shape folded with detector response (correlations); Relative Timing e + -  : gaussian shape with sigma = 147 (or 135) ps as for signal.

17 February 2010 Fabrizio Cei 10 Analysis: PDF determination 2) Accidental bck: fit of Gamma Energy, Positron Energy and Relative Angle for events falling in  T “side bands”  |  Te  | > 1 ns events falling in  T “side bands”  |  Te  | > 1 ns Accidental radiative decay + Positron Annihilation in flight + resolution + pileup Gamma Energy Important point: the PDF of the most dangerous background can be measured !

17 February 2010 Fabrizio Cei 11 Sensitivity evaluation Expected sensitivity evaluated with two methods: Toy MC assuming zero signal (two independent calculations): - generated 1000 independent samples of events using bck and RD pdf’s; - generated 1000 independent samples of events using bck and RD pdf’s; - upper bound on number of signal events evaluated for each sample; - upper bound on number of signal events evaluated for each sample; - average upper C.L: 6 events  - average upper bound on B.R.(  → e  ) = 1.3 x Fit to events in the sidebands: - applied same fitting procedure used for data in the signal region; - upper bound: B.R.(  → e  )  (0.9  2.1) x upper bound: B.R.(  → e  )  (0.9  2.1) x Comparison: present upper bound from MEGA experiment: 1.2 x

17 February 2010 Fabrizio Cei 12 Likelihood analysis Results in close agreement from the three analyses. Checks: Number of RD events in Number of RD events in agreement with predictions agreement with predictions and extrapolations from and extrapolations from sidebands; sidebands; Test of C.L. extraction Test of C.L. extraction with bayesian technique; with bayesian technique; Fits using TRG instead of Fits using TRG instead of DRS information and different  T computation algorithms; Fit to  T only (sensitive Fit to  T only (sensitive to signal + RD). Fit in the signal region

17 February 2010 Fabrizio Cei 13 E  vs E e+ Cut at 90% efficiency on other variables (relative angle and relative timing) 10 3 MC events

17 February 2010 Fabrizio Cei 14 B.R.(  → e  ) 90 % C.L. limit From the 90 % C.L. upper bound on number of signal events: N Sig  14.7 N Sig  14.7 we obtained the corresponding 90 % C.L. upper limit: BR(    → e +  )  2.8 x  2 times worse than the expected sensitivity. The probability of getting this result by a statistical fluctuation of the observed distributions is (3  5) % (Bad Luck !) Results available at arXiv: Paper to be submitted soon.

Present status of physics analysis 17 February 2010 Fabrizio Cei 15

DCH Several quantities to be calibrated: Common timing offset (t 0 ); Relative timing between end of wires (  r); Anode and pads charges (  z). Standard calibrations completed and implemented. Alternative calibrations/algorithms under way to: Check the origin of not yet adequate performances by means of independent codes; performances by means of independent codes; Try to improve such performances. Alignment check by cosmic rays measurements. 17 February 2010 Fabrizio Cei 16

DCH standard calibrations: z anodes 17 February 2010 Fabrizio Cei 17 Size of pad pitch

DCH standard calibrations: z pads 17 February 2010 Fabrizio Cei 18 Vertical offset Cathode Hood

Relative timing between ends of wires 17 February 2010 Fabrizio Cei 19 Ch’s with sync problems (Time_end0 – Time_end1) vs Wire Shows relative offsets before and after calibration. Shows relative offsets before and after calibration. The RMS of the not calibrated data seems to be dominated by deviant wires. The relative offsets of the calibrated data show a double peak. Since, this double peak structure comes about after calibration, it’s good indication that there is a pattern in the leading edge fits, or, first peak remained while deviant data points populated second peak. Under investigation. Low Track Statistics (T_end0 –T_end1) vs wire Low Gain Channels with sync Offsets calibrated not calibrated

Alternative algorithms/calibrations 17 February 2010 Fabrizio Cei 20 Z extrapolated from track Integration based on trapezoidal method Fit each separated charge independently as a function of z T (  s)

Single hit Z resolution 17 February 2010 Fabrizio Cei 21  core = 480  m, core fraction = 0.722, mean -35  m (asymmetric tail) cm Double gaussian fit |  Z| > 0.3 cm

Comparison of performances 17 February 2010 Fabrizio Cei 22 All these numbers were obtained by using the double-turn method  they must be divided by sqrt(2)     9 ÷ 11 mrad    15.5 ÷ 17 mrad  P  0.51 ÷ 0.61 MeV Numbers in parentheses () are RMS of distributions.

Preliminary analysis of cosmic ray data 17 February 2010 Fabrizio Cei 23 Tracks fitted by 3-D straight lines. Computed R and Z distance of track from nominal position of each chamber. Mean R  -440 micron Mean Z  -190 micron Chamber Chamber ChamberChamber IMPROVED, Starting point for new iteration. Analysis in progress

DCH: coherent noise 17 February 2010 Fabrizio Cei 24 Low frequency (  13 MHz) noise; more visible on pads. Can be fitted with a single or double sinusoidal shape and subtracted The remaining noise is more “white” then before The remaining noise is more “white” then before RMS reduced from 2.7 mV to 1.2 mV – more then twice RMS reduced from 2.7 mV to 1.2 mV – more then twice This is just an example, dominated frequency are visible in almost all WFs This is just an example, dominated frequency are visible in almost all WFs Possible tool to improve Z resolution Possible tool to improve Z resolution

DCH: MC studies 17 February 2010 Fabrizio Cei 25  Angular resolution depends on Z resolution, but not dramatically; resolution, but not dramatically;  To obtain a 15 mrad angular resolution one should use an resolution one should use an abnormally bad value  Z = 3 mm. abnormally bad value  Z = 3 mm. Usual way of measuring the angular resolution (double turn method) gives a systematically worse result than the difference wrt true value (2÷3 mrad shift). Resolution for signal events is better than for Michel events. 1: 300 micron, single gaussian 2: 470 micron, single gaussian 3: double gaussian Event Type MC Z Sigma Angular Resolution  Michel 100  m 7.0 mrad Michel 300  m 7.2 mrad Michel 470  m 7.6 mrad Michel 470  m  (70%) mm (30 %) 1.5 mm (30 %) 7.9 mrad Signal 100  m 6.0 mrad Signal 300  m 6.4 mrad Signal 470  m 6.6 mrad Signal 470  m (70%) mm (30 %) 1.5 mm (30 %) 7.0 mrad

DCH: present situation 17 February 2010 Fabrizio Cei 26   = 12.7 mrad   = 8.1 mrad  Z = 3.1 mm  R = 2.4 mm ≥ 8 hits, TC+DCH match as in MeV < E < 54 MeV

DCH: Comments Comparison between MC and present level of analysis (all in mrad): Data (2-turn) MC (2-turn) MC (true) Data (2-turn) MC (2-turn) MC (true) Michel  Signal  not avail Michel  fulfilled ! Signal  not avail Central column is our goal ! Not too far, but several possible actions … -Refine single hit Z calibrations; -Check the hit reconstruction/pattern recognition/tracking algorithms; -Check the database; -Refine comparisons with MC (number of hits, inefficiencies, materials …); -Improve CR data analysis  misalignment corrections, survey …. -Subtract coherent noise; -Understand and correct other effects which can deteriorate the resolution (cross talks, chamber breathing …) talks, chamber breathing …) 17 February Fabrizio Cei

Timing Counter  Several calibrations: - Time Walk with triple events  intrinsic bar resolution; intrinsic bar resolution; - z-offset; - effective velocity (under way); - timing calibration with MEG (Michel) and Dalitz events  inter-bar and Te  (Boron for check); events  inter-bar and Te  (Boron for check);  All constants in the database. 17 February 2010 Fabrizio Cei 28

Timing Counter cnt. 17 February 2010 Fabrizio Cei 29 Intrinsic resolution is a bit worse than in Studies under way to figure out the origin of the discrepancies. However, (70 ÷ 100) ps is still acceptable. Bar instrinsic resolution MEG Data. Z offset calibration with Michel events

Timing Counter cnt. 17 February 2010 Fabrizio Cei 30

Timing Counter: Comments TC bars stable during 2009 data taking; TC resolutions look a bit worse than in 2008; We expect some improvements from the next re- We expect some improvements from the next re- processing (better TC-DCH match; more accurate processing (better TC-DCH match; more accurate determination of calibration constants …); determination of calibration constants …); Some calibrations are under refinement (effective light velocity, inter-bar timing …); light velocity, inter-bar timing …); MC studies of Dalitz events to disentangle the contribution of track length uncertainty; contribution of track length uncertainty;…. 17 February 2010 Fabrizio Cei 31

Xenon Calorimeter 17 February 2010 Fabrizio Cei 32 Calibration chain almost completed: LED/Gain variation with time; LED/Gain variation with time; Q.E. determination by alpha data in liquid Xenon (in 2008: gaseous Xenon); Q.E. determination by alpha data in liquid Xenon (in 2008: gaseous Xenon); Uniformity corrections; Uniformity corrections; Pedestal determination (CEX-  difference); Pedestal determination (CEX-  difference); Timing constants for two different algorithms; Timing constants for two different algorithms; Full implementation in the database under completion; Full implementation in the database under completion; Everything ready before the next re-processing (sometimes in March). Everything ready before the next re-processing (sometimes in March).Checks: Uniformity of CW line energy; Uniformity of CW line energy; Linearity. Linearity.Results: Energy resolution with  0 ; Energy resolution with  0 ; Background spectrum. Background spectrum.

Xenon Calorimeter cnt. 17 February 2010 Fabrizio Cei 33 10% decrease Gain decrease correction Effect of first QE set. Further refinements under way to precisely match the calorimeter optical properties: - reflections - Rayleigh scattering …  3.3 %

Xenon Calorimeter cnt. 17 February 2010 Fabrizio Cei 34 Uniformity of 17.6 MeV CW Li peak. Each point represents the reconstructed position of the Li peak in a 3-D spatial bin. Linearity curve determined by using  0. CW points look displaced by 1% (under study).

Xenon Calorimeter cnt. 17 February 2010 Fabrizio Cei 35 CEX energy resolution (FWHM) as a function of time. Purple line obtained by inserting pedestal fluctuations in MEG runs.  upper = 2.0% in a 2x2 PMTs grid (usual 1x1); 1.95% for collimator #8. Background spectrum. Fit with a combination of RD+AIF (Green), and Pile-up (Blue). - Resolution just a bit worse than in 2008; - Resolution just a bit worse than in 2008; - Energy scale not exactly 1 because of - Energy scale not exactly 1 because of a mistake in configuration parameters a mistake in configuration parameters (data to be reprocessed). (data to be reprocessed).

Xenon Calorimeter: Comments  Calibration chain used in 2008 looks adequate.  Work in progress for further improvements (i.e. Q.E determination); (i.e. Q.E determination);  Energy resolution a bit worse than in 2008, but analysis work still preliminary. Nevertheless, but analysis work still preliminary. Nevertheless, 5% FWHM goal in energy resolution already fulfilled. 5% FWHM goal in energy resolution already fulfilled.  Timing resolution requires further efforts: - single PMT timing extraction; - single PMT timing extraction; - boards calibration/synchronization; - boards calibration/synchronization; - …. - ….  First background energy spectrum  preliminary PDF. 17 February 2010 Fabrizio Cei 36

RMD observation 1) 17 February 2010 Fabrizio Cei 37 Single bar  = 209 ps All bars Three independent analyses, with different cuts or no cuts at all. Peak well visible above background without need of refined searches. Offset subtracted, but mean displaced by  300 ps

RMD observation 2) 17 February 2010 Fabrizio Cei 38  Pre-selection window needs to be re-centered.  Resolution is some tens of ps worse than at the end of 2008 (XEC/TIC calibration constants ? tracking ? To be addressed) (XEC/TIC calibration constants ? tracking ? To be addressed) RMD signal stable along the data taking period. In 2008 the signal became less and less visible because of the reduced DCH efficiency.

Perspectives for 2009 data analysis 17 February 2010 Fabrizio Cei 39

2009 Data Sample Fabrizio Cei 40 preliminary Short run, but very smooth Improved tracking and trigger efficiency  6.5 x muons stopped in the target  6.5 x muons stopped in the target 17 February 2010

Perspectives for 2009 data 1) With respect to 2008 the starting conditions of our analysis are generally better: - Xenon calorimeter stable at predicted light yield; - stable behaviour of DCH; only few channels not working properly; - higher trigger efficiency  88% because of better direction match LUT. match LUT. The analysis scheme we plan to use is similar to that of 2008, which allowed to produce our first paper: - 2 ÷ 3 complete reprocessing, starting from waveforms (< 2 weeks per each); (< 2 weeks per each); - some (  5) reprocessing of pre-selected data (few days per each); - pre-selection/selection/blinding windows to be refined. 17 February 2010 Fabrizio Cei 41

Perspectives for 2009 data 2) A strong calibration effort is under way on all sub- detectors, based on the first data processing. - Calibration constants still to be optimized; - However, resolutions close to that obtained last year at the end of analysis chain; - DCH angular resolutions already better than in 2008; continuous optimization work by a dedicated working group; continuous optimization work by a dedicated working group; - Possible improvements by alignment check; - Xenon calorimeter energy resolution at 5% FWHM level; - Improvements in timing resolution expected from DRS timing calibration; Selections and cuts to be optimized to reach the best compromise between resolutions/background rejection and efficiency. Algorithms for final analysis (i.e. likelihood) well tested on 2008 data. 17 February 2010 Fabrizio Cei 42 A detailed job list with time schedule will be prepared as in 2008 !

Physics analysis schedule for February 2010 Fabrizio Cei 43 Finalize Calibrations/resolutions Final reprocessing BG Estimation Normalization Systematics Feb Final analysis Open box MarAprMayJunJul ICHEP2010 (submission) Reprocessing Next reprocessing(s) Various checks of final result Update

Performance Summary measured in sigma (preliminary) 2010 (preliminary) “Goal” Gamma Energy (%) Gamma Timing (psec) Gamma Position (mm) Gamma Efficiency (%) e + Timing (psec) e + Momentum (%) e + Angle (mrad) e + Efficiency (%) e + -gamma timing (psec) Muon Decay Point (mm) Trigger efficiency (%) 2.0(w>2cm) 80 5(u,v)/6(w) 63 < (φ)/18(θ) (R)/4.5(Z) 66 ← >67 ← (φ)/11(θ) 40 < (R)/3.1(Z) (w>2cm) 68 ← (φ)/8(θ) (R)/2.5(Z) (u,v)/5.9(w) (100%) Stopping Muon Rate (sec -1 ) DAQ time/Real time (days) 3×10 7 (300μm) 48/78 2.9×10 7 (300μm) 35/43 3×10 7 (300μm) 133/162 3× /- box Expected N BG Sensitivity BR upper limit (obtained) 5× × × × × × × × × February Fabrizio Cei

2009 Expected Sensitivity Estimate by means of toy MC simulation/Feldman-Cousins. – Updated resolutions and data statistics in table – N BG in analysis window estimated by scaling N BG in analysis window in 2008 – A little narrower analysis window (signal efficiency x 0.95) – N BG expected in analysis window: 435 N BG in (old) 90% signal box: 1.1 Results: – Average N signal upper limit: 6.9 – Average BR upper limit: 6.6× × (2.0 × )/2.2/ × (2.0 × )/2.2/ February Fabrizio Cei 2008 sensitivity in analysis window Improvement in data statistics wrt 2008

Expected Sensitivity for 2010 or later Estimate by means of Poisson statistics/Feldman-Cousins – Updated resolutions and data statistics in table – N BG in signal box is estimated by the PDF probability ratio. – Asymmetric 90%-efficiency signal box to optimize S/N (same efficiency but less BG) (same efficiency but less BG)Results – 2010 (stat. ratio to 2008: 11.4) S.E.S.: 4.0 × S.E.S.: 4.0 × N BG : 0.9 N BG : 0.9 UL: (4.0 × ) × 3.2 = 1.3 × UL: (4.0 × ) × 3.2 = 1.3 × – (stat. ratio to 2008: ) S.E.S.: 1.2 × S.E.S.: 1.2 × N BG : 3.0 N BG : 3.0 UL: (1.2 × ) × 4.41 = 5.3 × UL: (1.2 × ) × 4.41 = 5.3 × February Fabrizio Cei

Backup slides 17 February 2010 Fabrizio Cei 47

17 February 2010 Fabrizio Cei 48 Analysis cuts Track quality cuts (minimum number of hits and chambers, good chi2 for fit …); Track quality cuts (minimum number of hits and chambers, good chi2 for fit …); Selection of track with best pattern recognition; Selection of track with best pattern recognition; Track timing determined by position matching between DCH and TC; Track timing determined by position matching between DCH and TC; Elliptical cuts on target and beam spot at COBRA centre. Elliptical cuts on target and beam spot at COBRA centre. (Already used to evaluate normalization factor by means of Michel positron events) Cosmic ray rejection based on front/back charge ratio on the LXe calorimeter; Cosmic ray rejection based on front/back charge ratio on the LXe calorimeter; Fiducial volume cut for photons; Fiducial volume cut for photons; Pile-up identification in the LXe calorimeter and photon energy correction; Pile-up identification in the LXe calorimeter and photon energy correction; Collinearity cut on photon-positron relative angle; Collinearity cut on photon-positron relative angle; 50 MeV < E e < 56 MeV; 50 MeV < E e < 56 MeV; 46 MeV < E  < 60 MeV; 46 MeV < E  < 60 MeV; |  t e  | < 1 ns; |  t e  | < 1 ns; Multiple algorithms and two independent digitizers for photon energy/timing  checks ! Positron Photon and photon-positron correlation

17 February 2010 Fabrizio Cei 49 3-D view of a MEG event Positron Track Hits on DCH Hits on TC Photon Trajectory Hits in XEC

17 February 2010 Fabrizio Cei 50 Events in signal region vs pdf’s Distributions normalized to the total number of events Black: real events Red: signal pdf Red: signal pdf Blue: RD pdf Blue: RD pdf Green: accidental pdf Green: accidental pdf Positron Energy Gamma Energy Gamma Positron Angle

17 February 2010 Fabrizio Cei 51 Systematic Effects 1) % psecpsec N Sig (90 % C.L.) N Sig (90 % C.L.) Analysis repeated by changing one parameter at a time and building new pdfs. 0.6 % error on E  scale   N Sig = 0.6 EEEE  (E   (t(t(t(t tttt

17 February 2010 Fabrizio Cei 52 Systematic Effects 2)  ,   = (10 mrad, 18 mrad) x X Assuming 10% error   N Sig = 0.35 Positron angular resolution Positron Energy Scale 300 keV error   N Sig  1

Timing Counter cnt. 17 February 2010 Fabrizio Cei 53 T e  distribution obtained with Dalitz sample.  T (ns) Blue: 2009 Red: 2008 (final reprocessing) Check with Boron sample

Xenon Calorimeter cnt. Timing resolution  Intrinsic timing resolution is good (  45 ps);  Electronic + analysis contribution to LXe-TC timing resolution measured by using a split pulse. timing resolution measured by using a split pulse. Sigma  (105 ÷ 120) ps, dominated by Sigma  (105 ÷ 120) ps, dominated by inter-board synchronization. inter-board synchronization.  Lower contributions from smoothing functions (different for DRS2 and DRS4) and functions (different for DRS2 and DRS4) and same board synchronization. same board synchronization. 17 February 2010 Fabrizio Cei 54

Comments Gamma energy 1.5% (2010): resolution measured at the best position in 2009 Gamma timing 68 ps (2010): resolution measured at CEX in Dec Better than resolution quoted for run2008 (80ps) due to light yield improvement. than resolution quoted for run2008 (80ps) due to light yield improvement. Positron timing <125 ps (2008/2009): 148(e-γ) ⊖ 80(Xe), including DRS effect partially. Positron timing 90 ps (2010): 70(TC) ⊕ 60ps (path length, MC) Positron-Gamma timing 120 ps (2010): 70ps (TC) ⊕ 60ps (path length, MC) ⊕ 68ps (Xe). No contribution from DRS. No contribution from DRS. Positron momentum 1.6% (2008): average over core and 2 tails Positron momentum 0.85% (2009): single Gaussian Positron momentum 0.7% (2010): single Gaussian Positron angle 8 mrad(  ), 11 mrad(θ) (2009): resolution measured in MC by two-turns track method track method Positron angle 8mrad(  ), 8mrad(θ) (2010): resolution measured in MC Positron efficiency 40% (2009/2010): measured in 2009 with trg22 Muon decay point 2.2mm(R), 3.1mm(Z) (2009): resolution measured by two-turns track method method Muon decay point 1.4mm(R), 2.5mm(Z) (2010): resolution measured in MC by two-turns track method track method DAQ time: (real) days for the MEG trigger DAQ time (Peter’s estimation) N BG in 90% signal box (2008/2009): recalculated with NEW asymmetric signal box. 17 February Fabrizio Cei