Satish Mallya January 20-22, 2010 1 |1 | 1-7 Manufacturing Basics and Issues: Solid Orals PQP Assessment Training January 18-21, 2012 Satish Mallya January.

Slides:



Advertisements
Similar presentations
Training Workshop on Pharmaceutical Development with a Focus on Paediatric Medicines / October |1 | Training Workshop on Pharmaceutical Development.
Advertisements

Processes Used to Separate Ceramic Materials
2-5. Formulation Development Issues: Solid Orals Satish Mallya January, 2011.
National Institute for Pharmaceutical Technology and Education (NIPTE) Interim Risk Assessment Report.
PM3125: Lectures 18 to 21 Content of Lecture 18:
TABLET MANUFACTURE FORMULATION AND PROCESSING
Methods of tablet manufacturing
Satish Mallya January 20-22, |1 | 3-1. Assessing Batch Records Satish Mallya Quality Workshop, Copenhagen May 18-21,2014 May 18-21,2014.
Pharmacopoeial tests (USP)
How To Prepare, Sterilize, AND Test Culture Media
Tablet manufacturing process 322 PHT
Drying in the Pharmaceutical Industry1 DIT- Msc Pharmaceutical and Chemical Processes Technologies 28 th April 2009 Sara Baeza.
Tablet Coating Why coat tablets? Types of coatings  sugar coating  film coating  press coating (compression coating) B. Amsden1CHEE 440.
TABLETS a mixture of powders compacted to form a single, rigid body most common dosage form possess a number of advantages B. AmsdenCHEE 440.
PROCESS VALIDATION OF TABLETS.
3-2. Assessing Production Documents: executed and master records
World Health Organization
Multi station rotary presses
A Seminar on 1.  Why to validate?  Parts of Equipment Validation  Who should do Equipment Validation?  Equipment qualification  Typical process flow.
Drying Extra slides Mahmoud Teaima, Ph.D..
Desiccation ,sublimation & tirturation
Presented By: Dr. Abdel Naser Zaid
DEVELOPMENT OF QUALITY BY DESIGN (QBD) GUIDANCE ELEMENTS ON DESIGN SPACE SPECIFICATIONS ACROSS SCALES WITH STABILITY CONSIDERATIONS Fluid Bed Drying Small.
Quality control of tablets
DRYING Dr. Basavaraj K. Nanjwade M. Pharm., Ph. D
Module 1, Part 3: Process validation Slide 1 of 22 © WHO – EDM – 12/2001 Validation Part 3: Process validation Supplementary Training Modules on Good Manufacturing.
PHARMACEUTICS- IV (PHT 414 ) Dr. Shahid Jamil SALMAN BIN ABDUL AZIZ UNIVERSITY COLLEGE OF PHARMACY L /9/2015 Factors Affecting Drug Absorption (Dosage.
Quality control Lecture 1.
Satish Mallya January 20-22, |1 | 2-3. Pharmaceutical Development Satish Mallya Quality Workshop, Copenhagen May 18-21, 2014 May 18-21,2014.
18.1 Introduction Powder metallurgy is a process by which fine powdered materials are blended, pressed into a desired shape, and then heated to bond.
GRANULATION DR. MOHAMMAD KHALID ANWER Assistant Professor 2/25/20161 COLLEGE OF PHARMACY, PRINCE SATTAM BIN ABDULAZIZ UNIVERSITY.
Tablet Granulation. Introduction  Granulation is the process in which primary powder particles are made to adhere to form larger, multi particle entities.
Quality control Lecture 1.
CONTENTS Introduction Objectives of the Pilot Plant Significance of pilot plant Pilot plant scale-up techniques for tablets Reference 2.
Milling Is the reduction in the size mass by conversion of the large solid unit mass into smaller one by mechanical process. This needs energy.
“PROCESS SCALE UP AND CRITICAL CONTROL PARAMETERS OF PROCESS OF SOLID AND SOFTGEL DOSAGES”
TABLET GRANULATION TECHNIQUES.
Scale-Up Techniques for production of tablets
Methods of tablet manufacturing
DRY SYRUPS.
Tablets design and manufacture
Lecture 6 Drying.
Problems associated with the manufacturing of tablets
By K . Madhuri Ist M.Pharmacy pharmaceutics
Wet Granulation.
Evaluation of tablet Lab 5.
Quality control of tablets
Evaluation of tablet Lab 5.
INTRODUCTION Granulation process has been widely used in the pharmaceutical industry for the preparation of material for tabletting. Other Granulation.
IPSA (Industrial Problem Solving Ability )
Tablets design and manufacture
Group members: Firdaus | Sofia | Nurainiza | Hafizah
HHM 5014 NUTRACEUTICAL FORMULATION TECHNOLOGY
Quality control Lecture 1.
Milling Lab-6-.
Lab -7- Capsules.
Particle Agglomeration
Tablet Dosage Form Lab 1.
Lab 3 Industrial pharmacy
HHV 5014 Nutraceutical formulation technology
Wet Granulation.
Lab -7- Capsules.
Pharmaceutical Technology
INTRODUCTION TO INDUSTRIAL PHARMACY
Aram I. Ibrahim University of sulaimani College of pharmacy
Tablets Lecturer: dr. Asmaa abdelaziz Mohamed Faculty of pharamcay
POWDER AND GRANULES FADHILAH FAIROZA FATIN HUSNA
Quality control Lecture 1.
Evaluation of tablet Lab 5.
Milling Lab-6-.
Presentation transcript:

Satish Mallya January 20-22, |1 | 1-7 Manufacturing Basics and Issues: Solid Orals PQP Assessment Training January 18-21, 2012 Satish Mallya January 18-21, 2012

Satish Mallya January 20-22, |2 | Flow Chart API Filler Mixing of granulation blend Granulation Binder(s) Preparation of binder solution Drying Milling LOD Disintegrant screening Initial Blending lubricant screening Final Blending Compression Solvent Film coating agent Preparation Film Coating of Tablets Packaging and Labelling Weight Hardness Friability January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, |3 | Manufacturing Methods DIRECT COMPRESSIONDRY GRANULATIONWET GRANULATION Milling/Screening BlendingPre-blending CompressionSlugging/roller compactionAddition of binder Dry screeningScreening of wet mass Blending of lubricantDrying of the wet granules CompressionScreening of dry granules Blending of lubricant (and disintegrant) Compression January 18-21, 2012

Satish Mallya January 20-22, |4 | What's Good DIRECT COMPRESSIONDRY GRANULATIONWET GRANULATION Fewer processing steps – blending and compression - reduced processing time Processing without moisture and heat – fewer stability problems Rapid and most direct method of tablet compression Changes in dissolution less likely on ageing since there are less formulation variables Improved flow by increasing particle size Improved uniformity of powder density Improved cohesion during compression Granulation without addition of liquid Improved flow by increasing particle size and sphericity Uniform distribution of API, colour etc. – improved content uniformity Good for bulky powders, less dust and environmental contamination Lower compression pressure, less wear and tear on tooling January 18-21, 2012

Satish Mallya January 20-22, |5 | What's Not So Good DIRECT COMPRESSIONDRY GRANULATIONWET GRANULATION Possibility of lot to lot variations due to differences in psd, flowability and moisture of excipients Higher risk of content uniformity failure in low dose products (geometric granulation indicated) Lack of moisture can create static charges that can result in un- blending Differences in particle size/density between API and excipient can result in un-blending in hopper Possible over compaction of slugs/compacts – impact on dissolution Possible particle segregation Large number of processing steps More equipment Wetting and drying stages are time consuming Greater possibility of cross contamination January 18-21, 2012

Satish Mallya January 20-22, |6 | Steps Dispensing Milling/Screening Blending Granulation Drying Compression Coating Packaging January 18-21, 2012

Satish Mallya January 20-22, |7 | Dispensing One of the most critical steps in pharmaceutical manufacturing –manual weighing on a weight scale with material lifting assistance like vacuum transfer and bag lifters –automated weighing Issues: –dust control (laminar air flow booths, glove boxes) –weighing accuracy –multiple lots of active ingredient with different assays, moisture and residual solvent content –cross contamination January 18-21, 2012

Satish Mallya January 20-22, |8 | Raw Material Dispensing Record RM Code IngredientQty Kg AR No Gross Wt. Tare Wt. Net Wt.Weighed by Checked by Date API√√√√√√ Exp 1√√√√√√ Exp 2√√√√√√ Exp 3√√√√√√ Exp 4√√√√√√ Exp 5√√√√√√ January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, |9 | Considerations Theoretical quantity of API [100% assay (anhydrous) and nil water] = 30 Kg Sr. No. AR No.Total available quantity (as is basis) (Kg) (A) Actual Assay (%) (B) Water content (% w/w) (C) Equivalent quantity on 100% assay and nil water basis (Kg) (D) Equivalent quantity on as is basis (Kg) (E) 1AP AP ∑E ∑E January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, | Milling/Screening Principle: Mixing or blending is more uniform if ingredients are of similar size What are the problemsWhat are the equipmentWhy do it Possible change in polymorphic form An increase in surface area may promote the adsorption of air - may inhibit wetting of the drug – could be the limiting factor in dissolution rate Fluid energy mill Comil Ball mill Hammer mill Cutting mill etc. Increased surface area - may enhance rate of dissolution Improved content uniformity due to increased number of particles per unit weight Enhanced flow properties of raw materials Uniformly sized wet granules promotes uniform drying January 18-21, 2012

Satish Mallya January 20-22, | Manufacturing Instructions screening StepInstructionsTime start Time end Performed by Verified by Date 1.1API …… Kg Exp 1 …… Kg Pass through # 40 screen of Vibratory sifter and collect material in tared double PE lined container √√√√√ 1.2Exp 2 …… Kg Exp 3 …… Kg Pass through # 20 screen of Vibratory sifter and collect material in tared double PE lined container √√√√√ January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, | Blending Blending is the most difficult operation in the manufacturing process since perfect homogeneity is practically impossible due to differences in size, shape and density of particles What are the problemsWhat are the equipmentWhy do it Segregation Possible over mixing of lubricant Blend uniformity/ Content uniformity Diffusion Mixers (V,double cone, bin,drum blenders) Convection Mixers (ribbon, planetary blenders) Pneumatic Mixers To achieve optimum mixing of different ingredients in powder/granules at pre granulation and/or post granulation stages of tablet manufacturing January 18-21, 2012

Satish Mallya January 20-22, | Granulation Principle: A size enlargement process that converts small particles into physically stronger & larger agglomerates What are the problemsWhat are the equipmentWhy do it Loss of material during various stages of processing Multiple processing steps - validation and control difficult Incompatibility between formulation components is aggravated Dry Granulator (roller compactor, tabletting machine) Wet High-Shear Granulator (horizontal, vertical) Wet Low-Shear Granulator (planetary, kneading, screw) Fluid Bed Granulator, Spray Dry Granulator, RMG Provides homogeneity of drug distribution in blend Improves flow, compressibility and hardness of tablets January 18-21, 2012

Satish Mallya January 20-22, | Manufacturing Instructions blending & granulation Mixing SOP No.: Granulation SOP No.: StepInstructionsTime start Time end Performed by Verified by Date 2.1 Load material from 1.1 & 1.2 in RMG Exp 4 ……….Kg and mix for 5 minutes with following settings: Impeller speed-fast; Chopper speed-fast √√√√√ 2.2 Spray purified water into contents of RMG Impeller speed – fast; Chopper speed - fast Peristaltic pump atomization press: b Spray until all purified water is sprayed Ammeter reading amps √√√√√ January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, | Manufacturing Instructions wet milling Wet Milling SOP No.: StepInstructionsTime start Time end Performed by Verified by Date 3.1Pass wet mass through 1mm screen of Multi Mill Speed – fast; Knives - forward collect in FBD √√√√√ January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, | Recent Advances in Granulation Techniques Steam Granulation: Modification of wet granulation; steam is used as a binder instead of water; granules are more spherical and exhibit higher rate of dissolution Melt Granulation / Thermoplastic Granulation: Granulation is achieved by the addition of meltable binder i.e. binder is in solid state at room temperature but melts in the temperature range of 50 – 80˚C [e.g. PEG (water soluble), stearic acid, cetyl or stearyl alcohol (water insoluble)] - drying phase unnecessary since dried granules are obtained by cooling them to room temperature Moisture Activated Dry Granulation (MADG): Involves distribution of moisture to induce agglomeration – drying time is reduced January 18-21, 2012

Satish Mallya January 20-22, | Recent Advances in Granulation Techniques Moist Granulation Technique (MGT): A small amount of granulating fluid is added to activate dry binder and to facilitate agglomeration. Then a moisture absorbing material like Microcrystalline Cellulose (MCC) is added to absorb any excess moisture making drying step unnecessary. Mainly employed for controlled release formulations Thermal Adhesion Granulation Process (TAGP): Granules are prepared by moisturizing excipient mixtures with very little solvent in a closed system (tumble mixing) with low heating – mainly employed for preparing direct compression formulations Foam Granulation: Binders are added as aqueous foam January 18-21, 2012

Satish Mallya January 20-22, | Drying Purpose: To reduce the moisture level of wet granules What are the problemsWhat are the equipmentWhy do it Over drying (bone dry) Excess fines Possible fire hazard Direct Heating Static Solids Bed Dryers Direct Heating Moving Solids Bed Dryers Fluid Bed Dryer Indirect Conduction Dryers To keep the residual moisture low enough (preferably as a range) to prevent product deterioration Ensure free flowing properties January 18-21, 2012

Satish Mallya January 20-22, | Manufacturing Instructions drying Drying SOP No.: LOD: % (moisture balance at 105ºC) DateVerified by Performed by Time end Time start InstructionsStep √√√√ √√√√ √√√√ √√√√ √√√√ FBD in let temp 60ºC Damper 80% open for 15 min Damper 50% open after 15 minutes ; LOD ……..% 3.2 January 18-21, 2012

Satish Mallya January 20-22, | Manufacturing Instructions size reduction & blending Size reduction SOP No.: Blending SOP No.: StepInstructionsTime start Time end Performed by Verified by Date 4.1Fit 0. 8 mm screen to Multi Mill and pass material from 3.2 Speed – Medium Knives - forward √√√√√ 4.2Load dried granules from 4.1 into Conta Blender and blend for 20 mins at 12+1 rpm √√√√√ January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, | Manufacturing Instructions lubrication Lubrication SOP No. : StepInstructionsTime start Time end Perform ed by Verifie d by Date 5.1Fit 60 mesh screen to vibratory sifter and pass Exp 5 ……….Kg and collect in tared double PE lined container √√√√√ 5.2Add contents from 5.1 to 4.2 and blend for 3 mins and collect in tared double PE lined container √√√√√ January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, | Compression Principle: Powder/granules are pressed inside a die and compressed by two punches into required size, shape and embossing What are the problems What are the equipmentWhy do it Poor flow in hopper Inadequate lubrication Capping, chipping, cracking, lamination, sticking, picking, binding, mottling Double compression Multiple Stations (Rotary) and High Speed Tablet Presses To compress powder into tablets January 18-21, 2012

Satish Mallya January 20-22, | Manufacturing Instructions compression Balance no.:Vernier Caliper no.: Hardness tester no.:Friability tester no.: Disintegration tester no.: ToolingNo. of unitsChecked byVerified by Upper punch: …mm x …mm oval shaped concave embossed……. 55 Lower punch: …mm x …mm oval shaped concave embossed……. 55 Dies: …mm x ….mm oval shaped1 January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, | Manufacturing Instructions compression ParameterLimitResults Machine speed20 rpm (15-25 rpm) Wt. of 20 tabs12.00g +2 ( g) Theoretical weight/tab600mg Hardness25Kg (20-30 Kg) Thickness (av. of 10 tabs) 4.10mm +0.15mm (3.95 – 4.25mm) Length10mm mm (9.9 – 10.1 mm) Width5 mm + 0.1mm (4.9 – 5.1 mm) Disintegration timeNMT 15 mins Wt. variation+ 3% of Av. Wt. Friability (10 tabs)NMT 1.0% w/w January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, | In-process Checks ParameterFrequency Wt. of 20 tabsEvery hour by production and every two hours by QA Hardness, thickness, length, widthEvery hour by production, every two hours by QA Wt. variationEvery half hour by production and every hour by QA DTEvery half hour by production, every hour by QA January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, | Coating/Polishing Principle: Application of coating solution to a moving bed of tablets with concurrent use of heated air to facilitate evaporation of solvent What are the problemsWhat are the equipmentWhy do it Blistering, chipping, cratering, picking, pitting Color variation Roughness Pan (standard/perforated) Coating Machines Fluidized Bed Coating Machines Spray Coating Machines Vacuum, Dip & Electrostatic Coating Machines Enhance appearance and colour Mask taste and odour (film/sugar) Improve patient compliance Improve stability Impart enteric, delayed, controlled release properties January 18-21, 2012

Satish Mallya January 20-22, | Manufacturing Instructions coating StepInstructionsTime start Time end Performed by Verified by Date 6.1Introduce compressed tablets into Auto Coater and spray coating solution Inlet air temp …….ºC (30-60ºC) Pan speed……..rpm (2-8 rpm) Solution rate …..ml/min (20-60 ml/min) Distance of gun from tablet bed……cm (20-40cm) √√√√√ January 19-22, 2011 January 18-21, 2012

Satish Mallya January 20-22, | Other Issues Yield: –of lubricated granules –of compressed tablets –of coated tablets Dedusting Metal detection Scale up Life-cycle management January 18-21, 2012

Satish Mallya January 20-22, | Thanks