Corrosion Training CP Designed – Part 1

Slides:



Advertisements
Similar presentations
Mitigation of AC Induced Voltage On Buried Metallic Pipelines
Advertisements

Corrosion and Cathodic Protection
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Publisher The Goodheart-Willcox Co., Inc. Tinley Park, Illinois.
Basic Refrigeration Cycle
GROUND We walk on it, play on it, and live on it, but what is it in reality when it comes to communications systems, and how do we obtain a “TRUE” and.
Student Book © 2004 Propane Education & Research CouncilPage Installing Corrosion Protection Systems for Underground Tanks & Metal Distribution.
Arc Welding. Objectives Apply your welding knowledge to construct a butt weld in a group activity with 75% accuracy. Demonstrate how to properly weld.
STRAY CURRENT CORROSION
1 Hose and Lines. 2 High side / low side System with an expansion valve High SideLow Side Condenser Evaporator Receiver/Drier Compressor Expansion valve.
Student Book © 2004 Propane Education & Research CouncilPage Installing Buried Distribution Lines Using Polyethylene Tubing and Mechanical.
Gas Transmission Pipelines
Casing Spacers & End Seals
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
SMAW- Electrodes NCCER Unit 8.
Regional Sales Manager
Coatings – Directional Boring Tim Jenkins. Coatings – Directional Boring Design Considerations (data collection) Design Considerations (data collection)
Pipeline Current Mapper PCM
ELECRICAL CIRCUITS.
Electrical Power Systems
Corrosion Prevention Corrosion of steel, which consists mainly of iron, is a major problem in our society. But steps can be taken to prevent it.
Electrical Principles and Wiring Materials
Corrosion & Associated Degradation
Control of DC and AC Interference on Pipelines
STEAM HEATING.
Mechanical for Oil Heat
HOUSTON, TEXAS1 Corrosion Control and Monitoring ENGINEERING SERVICES LP HOUSTON, TEXAS Engineering Specification.
Atmospheric Corrosion NiSource Exposed pipelines.
Transmission Lines …….. Conductor Material
4.1.5 Student Book © 2004 Propane Education & Research CouncilPage Determining the Proper Corrosion Protection Systems for Underground ASME Tanks.
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
INTRODUCTION Definition:
Basic Cathodic Protection Measurement and Monitoring- IR Considerations Western Regional Gas Conference 2008 Tempe, Arizona By Paul Sedlet, Accurate Corrosion.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
Batteries The purpose of the battery is to act as a reservoir for storing electricity.
1 Safety and Preventative Maintenance. 2 MB, One megabyte - MB or M-byte - represents about 1 million (10 6 ) bytes. Precisely, 1 MB = = 1 kB x 1 kB =
Electrical Principles and Wiring Materials Unit #31.
Gandhinagar Institute of Technology
Electric Charges & Current Chapter 7. Types of electric charge Protons w/ ‘+’ charge “stuck” in the nucleus Protons w/ ‘+’ charge “stuck” in the nucleus.
TRENTON Casing Filler Presentation
Electrical Principles and Wiring Materials Original Power Point Created by Casey Osksa Modified by Georgia Agricultural Education Curriculum Office June.
Starting Residential Wiring.  The most important element in wiring. Safety is proper grounding.  Grounding is the connection of all parts of a wiring.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
Grounding the Electrical System Reference: AAVIM “Electrical Wiring” Created May 2007.
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
CORROSION MITIGATION OF A PIPELINE
Grounding the Electrical System
Materials Selection and Coatings
CHAPTER 2 Pipeline Coatings.
Electrical Principles and Wiring Materials
Basic Corrosion Theory
Grounding the Electrical System
Evaluation Techniques
EARTHING.
Evaluation Techniques
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Piping.
Current Attenuation and ACVG Surveys Gary Moss
Govt. Polytechnic,Manesar
CATHODIC PROTECTION 5,1 INTRODUCTION
Corrosion & Associated Degradation
Domestic Electricity AIM: To understand the use of domestic electricity and safety features such as fuses, circuit breakers and the earth circuit
TRENTON Casing Filler Presentation
Corrosion Control and Monitoring
Field Testing for Shorted Casings
ELECTRICAL ISOLATION Heather Groll.
2019 AUCSC Fundamentals Session Jeff Didas – Matcor - Tucson, AZ
Corrosion Control and Monitoring
Presentation transcript:

Corrosion Training CP Designed – Part 1 Galvanic Anodes (current requirement testing), Insulators, Test stations, Coatings

Learning Over View Part One – Part Two – Part Three – Current requirement design Galvanic anode design Insulators Coatings Test stations Coupons Part Two – Rectified Systems, Solar panels Part Three – AC Design

Objective of Class Understanding of design for COH and CKY with Corrosion Anodes (Galvanic) Insulators (types) Coatings (types) Test stations IR Coupons

Galvanic Anodes – Types? Magnesium anodes are used for galvanic anodes in our system 17lb anode - remediation of WT pipelines 17lb anode - new steel coated pipe 9lb anode - bare main or service 3lb anode - bare customer service 1.5lb drive in anode – company or customer metallic coated risers 1.0lb zinc serv-a-node

Galvanic Anodes – When? Any time a metallic pipeline is exposed and the surface of the pipeline is disturbed and the pipe to soil readings are below -1.000 V CSE. Any time corrosion technician has indicated on corrosion recommendations CP mains reading below -.850 V CSE on a 2512 J.O. (annual monitoring) Cost and application evaluation performed for comparison of anodes vs. solar vs. rectified systems

Galvanic Anodes – Connected? Thermite welded to the pipeline Thermite welds shall be 4” apart from each other Thermite welds shall be 6” away from an adjacent weld At any test station locations, connected by mechanical means by junction of the test station terminal

Galvanic Anodes – Design? Current Requirement test Soil resistivity test Determine the output of a 17lb HP anode Number of anodes = Icp/Ia Sunde theory

Galvanic Anode – Design (new Coated Steel Main) Surface Area of pipeline Diameter Length Coating Effectiveness Current Density Soil Resistivity

New Steel Pipe Calculations – Number of anodes For an example – First calculate the total surface area of 6” WT MP pipe at a length of 12,000 feet? Use the formula Total surface area = Diameter x Length x 

New Steel Pipe Calculations – Number of anodes For an example – First calculate the total surface area of 6” WT MP pipe at a length of 12,000 feet? Keep in mind, a 6 inch diameter pipe is truly 6.625 inches  R Length Area 3.14 • (6.625) = 1.735 • 12,000 = 20,820 sq ft 12 Need to divide the diameter by 12” to convert to feet

New Steel Pipe Calculations – Number of anodes Next Calculate the total coating effectiveness The coating effectiveness will decide the total bare area that the CP current will be needed Keep in mind, the CP current protects only the holiday areas of the pipeline Calculate Coating Effectiveness % 99.5 % - Great 98.5% to 99.5% - Good 95% - Fair Less than 95% - Poor

New Steel Pipe Calculations – Number of anodes Next Calculate the total coating effectiveness The coating effectiveness will decide the total bare area that the CP current will be needed Keep in mind, the CP current protects only the holiday areas of the pipeline Calculate Coating Effectiveness % 99.5 % - Great (Columbia’s Standard used) 98.5% to 99.5% - Good 95% - Fair Less than 95% - Poor

New Steel Pipe Calculations – Number of anodes What is the total surface area?

New Steel Pipe Calculations – Number of anodes What is the total surface area? 20,820 sq ft What is the total bare area of the pipeline?

New Steel Pipe Calculations – Number of anodes What is the total surface area? 20,820 sq ft What is the total bare area of the pipeline? 104.1 sq ft

New Steel Pipe Calculations – Number of anodes Next calculate the total amount of current requirement for CP of the pipeline Total bare area x current density = ICP What is the bare area? 104.1 sqft What is the current density?

New Steel Pipe Calculations – Number of anodes Current Density Is considered the square of the pipeline in which will conduct current Normally in the range 1 to 3 mA Sandy or Dry soil – 3 mA Semi-dry soil – 2 mA Wet soil – 1 mA For current requirement calculations, we use a higher number for higher soil resistivity for the purpose of designing a higher amount of current requirement.

New Steel Pipe Calculations – Number of anodes What if the soil was very sandy and normally dry? Next calculate the total amount of current requirement for CP of the pipeline Total bare area x current density = ICP 104.1 x 1mA = 104.1 mA’s Bare Area of pipeline Current density Total amount of current requirement

New Steel Pipe Calculations – Number of anodes Next calculate the total amount of current requirement for CP of the pipeline Total bare area x current density = ICP 104.1 x 3mA = 312.3 mA’s Bare Area of pipeline Current density Total amount of current requirement Change current density to a higher number, such as 3 mA’s

New Steel Pipe Calculations – Number of anodes Number of anodes = Icp/Ia What is the total requirement for wet soil? Based on our calculations = 104.1 mA’s How many anodes needed? Have to calculate anode output next??? 120,000 • f • y ρ

New Steel Pipe Calculations – Number of anodes The top three numbers are given based anode design, such as shape and weight of anode. 120,000 • 1 • 1.21 = 22.3 mA 6,500 ohms cm Anode output is calculated Input the soil resistivity to the bottom of the equation

New Steel Pipe Calculations – Number of anodes Now with the anode output and the total amount of current requirement is calculated, What is the total amount of anodes needed, if we decide to bank the anodes 10 feet apart? Number of anodes = Icp/Ia 104.1 mA / 22.3 mA = 4.6 (round to highest number = 5 anodes) 5 anodes Correct or not?????????? Need more anodes – Not the correct design

Sunde Theory Used for banking anodes 10 FT spacing 5 anodes 5 anodes at 10ft apart = 4.19 anodes

Sunde Theory Calculation 5 anodes to be banked at 15 feet spacing. 4.43 • 22.3mA = 98.8 mA The current requirement was at 104mA therefore 5 anodes would not be enough. 6 anodes to be banked at 15 feet spacing. 5.22 • 22.3mA = 116.4mA The current requirement was at 104mA therefore 6 anodes would have enough output to meet cathodic protection.

New Steel Pipe Calculations – Number of anodes Summary 6” WT Pipe @ 12,000 length = 5 anodes, if distributed along the line 6 anodes, if banked at 10 feet apart Soil resistivity of 6500 ohms cm Current density of 1 mA Coating effectiveness of 99.5%

Test Stations Above Ground B-T Cott Large Fink Small Fink Gerome Tri-view flex B-T Curb box type COH and CKY – Recommended use is the Tri-view flex for above ground use Gerome box for any continuity or interference bonds

Test Stations Two wires – No. 12 Black Two wires – No. 12 White New Carrier pipe Two wires – No. 12 White Old/bare Casing

Test Stations Interference test station (bond) Two No. 8 wires (1-Company & 1-Foreign) Two No. 12 wires black (company) Two No. 12 wires white (foreign)

Test Station - Spacing's Business – 750 Feet Residential – 1500 Feet Rural – 6000 Feet P/P - 653-3

Coatings Coatings are our first line of defense against corrosion. Coatings are a high resistance barrier between the metallic structure and the surrounding electrolyte. A quality dielectric coating material can reduce costs in additional corrosion control materials such as sacrificial anodes or impressed current type cathodic protection systems.

Coatings Cathodic protection system design is based upon protecting the bare surface area of the buried/submerged metallic structure. Typically a well coated pipeline will be protected over 90% of its surface. In this case, only 10% of the pipeline surface will require cathodic protection current.

Coatings As an example: 100 feet of 12” diameter pipe has 314 ft2 of surface area. A vertically installed 17# high potential magnesium anode in 5000 Ω-cm soil has a current output of 30 mA. A design current density of 2 mA/ft2 results in a current requirement for the pipe of 628 mA. With 30 mA per anode, 21 anodes are required. However, if the pipe is 90% coated, then only 10% or 31.4 ft2 is bare. At 2 mA/ft2 the current requirement is 62.8 mA. With 30 mA per anode, only 3 anodes are required! This shows the importance of having a quality coating.

Coatings Holiday Testing (Jeeping) Test process which the operator can identify holidays (imperfections) in the coating Involves a high voltage power source Instruments can be adjusted to apply the proper voltage across the coating Different thickness’ of coating requires different settings Electrode is passed over the coating surface If the coating resistance is low or a holiday is present, an audio signal is heard due to an electrical discharge from the electrode onto the pipe surface Repair of the coating is made

Coatings – Jeep Settings Fusion Bonded Epoxy Powercrete Extruded

Coatings – Jeep Settings Some common Jeep voltage settings for common coatings

Coatings – Jeep settings You maybe asked to QA or verify the coating thickness base on the jeep process Check the coating thickness DFT Check the voltage setting of the Jeep Verify, the contractor or crew is creating a holiday to verify the setting

Coatings – Jeep Process

Coatings – Jeep Process

Coatings Three common types mostly used in the gas industry Extruded Fusion bonded epoxy (FBE) Powercrete

Coatings Extruded High density polyethylene Can be supplied in different thickness’ up to 60 mils Asphalt or rubber butyl adhesive Normal thickness is in the range of 10 to 15 mils Used primarily for direct bury application Girth welds normally coated with cold-applied tapes

Coatings - Extruded

Coatings - Extruded Direct Bury - X-Tech II – COH & CKY practice for direct bury design, 1st choice 70 mill application Two layers of 30 mills of polyethylene coating 10 mills of butyl rubber mastic

Coatings - Extruded Design for AC and/or DC interference currents Use only Extruded – X-TECH II coating systems

Coatings - FBE Fusion Bonded Epoxy Surface preparation includes sand blasting To clean the surface and form anchor patterns for the coating to adhere or bond to the pipe surface Surface is acid washed to remove salt deposits Surface is washed with dionized water Pipe surface is heated to 500 degrees or hotter Epoxy powders are electro statically charged and sprayed onto the hot surface The powders melt to a liquid form and fuse to the pipe surface forming a hard shell The applied coating normally cures within 90 seconds and then is blasted with cool water in order to facilitate handling

Coatings - FBE FBE 12 – 15 mills of FBE first layer 20 mills of FBE second layer Total of 32 to 35 mills coating COH & CKY practice – only use dual coats, never single layer systems, 2nd choice for direct bury

Coatings – Powercrete Epoxy base Polymer Concrete The pipe is coated with an FBE normally with a thickness of 12 to 15 mils The FBE is then coated with the polymer concrete coating (Powercrete) 20 mills

Coatings - Powercrete Can be applied in the field Each pass applies approx. 20 mils thickness Max – 125 mils Perfect for directional boring COH and CKY – recommendation for directional boring design Use for above ground design with a polyurethane outer coat Girth welds can be coated with a two part liquid epoxy, need to apply enough thickness to allow the jeeping to pass from the pipe surface pass the girth weld without adjusting the voltage setting.

Coatings - Powercrete COH & CKY practice – a minimum of 50 mils for above ground application COH & CKY practice – a minimum of 50 mils for directional boring application COH & CKY practice – a minimum of 70 mils for rocky directional boring applications Girth welds can be coated with a two part liquid epoxy, need to apply enough thickness to allow the jeeping to pass from the pipe surface pass the girth weld without adjusting the voltage setting.

Coatings – Girth Welds Girth Welds FBE and Powercrete coating applications COH & CKY practice – two part liquid epoxy system Protal 7200 – temp’s at or above 50 degrees Protal 7125 – temp’s below 50 degrees R95 – temp’s at or above 50 degrees – back up coating Surface will need to be sand blasted to a Nace 1 anchor pattern The two parts are mixed Epoxy resin Epoxy hardener Coat the surface of the girth weld according to manufacture’s recommended wet film thickness Use the same material on the holiday areas as well

Coatings – Girth Welds Girth Welds Extruded Coatings – X-Tech II Acceptable methods – Polyken 936 Tape coat H35 Petrolatum Tape Utility tape (PVC) on new steel applications to be used S105 paste recommended, especially in cold climates

Coatings – Thermite welds No mastic….. Preference – especially for vacuum systems Acceptable methods – Petrolatum products Profile mastic petrolatum – Denso product (bird seed) Top coat with the Denso Color Tape – petrolatum – Denso product Protal 7200 cartridge Mix product on cardboard Dip brush and paint onto surface Cover with Trenton wax paper to prevent any damage due to debri of dirt Trenton patch kits (watch cost – higher dollar)

Coatings – Transmission and/or Directional boring Applications Corrosion FLL shall be contacted Corrosion department will inspect the pipeline at the coating Mill using the recommended “Hold points”

Coatings - Rock shield In a rocky back filled situation, one should apply an outer protected shield for your pipeline coatings. Note: On CP systems, use the mesh rock shield only….. As to not cause cathodic shielding with the solids This is not a coating but a impact aid for the coating to prevent chipping or damage from rocks

Insulators - Types Kero-Test Monolithic – Weld-in Bangs – Flanged – Weld-in Dresser bolted coupling Compression Unions Flanges

Insulators – When? Tying new pipe to old pipe (coated) Tying coated pipe to bare pipe Domestic, large volume and GM settings Separate house lines from company lines Casing from carrier pipe Pipe from supports Bridges M&R settings Break a large circuit to smaller units for easier troubleshooting and management Separate shorts with foreign lines River crossings

Insulators - Tying new and old existing Coated Pipelines Recommended for use in galvanic systems due to limited driving potential of the magnesium anodes Cost comparison Evaluate the cost for an insulator to be installed For example, if one insulator to separate a 100’ section of new coated metallic pipe from an existing CP coated metallic anode system (older), will cost in the range 4,800.00 x 2 = 9,600.00; then it may not be cost effective to make this recommendation. Purpose – to prevent a galvanic cell to be created due to the potential difference with the new coated pipeline and the old coated systems For an example, the new coated system can have a high negative potential in reference to the old coated bare main.

Insulators - Tying new and old existing Coated Pipelines Test station installed at location Two black wires - #12 (New) Two white wires - #12 (old) Two no. 8 wires One wire connected to the New One wire connected to the old Bond in the test station box, if rectified system If anode system and want to cathodically protect as a single circuit

Insulators - Tying new and old existing Coated Pipelines If not bonded in the test station box, then create two facilities on WMS and two test point sheets

Insulators - Tying new and old existing Coated Pipelines Recommended spacing's of insulators Business – 1500 feet Residential – 3000 feet Rural – 12000 feet

Insulators - Tying to Bare Pipe All coated systems tying to bare systems are to be insulated off Test station installed at location Verification to be made on annual monitoring Trouble shooting purpose Two white wires on the bare pipe Two black wires on the coated pipe

Insulator – Weld - In COH & CKY practice – always use weld-in insulators and only the Zunt monolithic for buried pipelines Monolithic weld end insulators are an excellent choice for high pressure systems where pull out may be an issue with other insulated coupling devices. Failure contributes are normally due to over heating the polymer material separating the two ends. The operator should be able to touch the center of the device with out being burnt during a welding operation. If the device at the center location is hot to touch, apply wet rags to cool. Recommend to test the insulator before installation and after, this may tell the reason why the insulator has failed, was it due to manufacture defect or the welding operation. No field assembly required or bolts,washers or sleeves that could cause an electrical short.

Insulators - Meter settings - Types Insulated valves Insulated Unions Insulated Meter bars Insulated Swivels Insulated Flanges Design purpose – Domestic size meters Insulated Valves Large volume, or GMB accounts Insulated flanges

Insulators – M&R Station Insulated in a structure Must have a zinc grounding cell installed (DOT and procedure requirement) Insulated at flange @ outlet of valves Outlet valve If need to replace flange insulators, on lower pressure end Bypass valve All control lines need to have insulated unions

Insulators – M&R Station A high dielectric strength material is used – fiber glass or a plastic material to prevent a metallic connection between the two flange faces. Make a note, if using one insulated washer on the flange face, if the flange is going to be buried, you need to make sure the washer is on the correct side in order to protect the bolt and nut of the flange. The washer should be on the same side of the non protected side. You can order the insulating kits for existing above ground systems, for new or replacement flange insulators. Most times, you can replace one bolt at a time with an insulated sleeve and washer, and not separate the flanges to achieve isolation between the two; saves cost from rerouting gas flow or shutting down the system. The bolt acts as a bypass if not insulated properly.

Insulator – Casing and Carrier Pipe Casing isolation – two primary functions Prevent an electrolyte from entering the casing and creating a galvanic corrosion cell. Prevent metallic contact between the carrier pipe and casing pipe. Casing isolation may remove up to two of the four parts of a corrosion cell. The carrier pipe would become cathodically shielded by the casing. One needs to eliminate the electrolyte inside the casing to prevent the carrier pipe becoming anodic to the the casing, this will lead to corrosion over time then eventually leakage occurs.

Insulators – Casing & Carrier Pipe Casing isolation – Three primary tools used Casing filler High dielectric material (high resistance) to displace the electrolyte within the casing Casing spacers Insulating material to prevent metallic contact between the casing pipe and the carrier pipe Casing seals Physical seal used to seal the ends of the casing in order to prevent an electrolyte from entering the casing

Insulator – Casing & Carrier Pipe – Casing Filling Petrolatum based material that has a high dielectric strength. Displaces the surrounding electrolyte in the casing around the carrier pipe. Prevents water from entering the casing and displaces the existing water. Environmentally safe – non-hazardous. If you have a shorted casing that can not be removed, casing filler is a DOT option. You can cathodically protect the carrier pipe by supplying a non-corrosive environment inside the casing then you must protect both the carrier and the casing pipe together as a single unit.

Insulator – Casing & Carrier Pipe – Casing Filling Casing filler can be installed hot or cold. There is treatment for casings already filled with water. Hot casing filler - Pumped at 80 to 100 degrees, pumped directly into the casing by heated tankers Cold casing filler – pumped at 50 degrees, gel like, normally 55 gallon drums PRE-CON is a liquid casing water conditioner for pipeline casings. It consists of "wetting" and filming agents, vapor phase inhibitors, alkaline media additives and anti-bacterial conditioners Pictures -Courtesy of Trenton co.

Insulator – Casing & Carrier Pipe - Spacers Spacers are made from a dielectric material, hard polymer (plastic). A spacers primary function is to prevent the metallic contact between the casing pipe and the carrier pipe. Separates the metallic contact between the casing and the carrier pipe

Insulators – Casing and Carrier Pipe – Link Seals & Rubber boots Seals the ends of the casing around the carrier pipe. Keeps the casing filler inside the casing. Prevents water or other elements from entering the casing and creating a galvanic cell. You need to seal the ends before pumping the casing filler into the casing

Pipe Supports Coated metallic pipe shall be isolated from any bridge structure Fiber board Glass mesh – insulated bridge supports

Pipe Supports Coated metallic pipelines shall be insulated from any supports at M&R settings Existing pipe may need to be lifted off the support area to be insulated properly

Insulator – FRP’s FRP’s – Fiberglass Reinforced Plastic FRP’s are made of a fiberglass material, a high di-electric material, to prevent a conductive path between the anode and the cathode.

Insulator – FRP’s Primary function of FRP’s To prevent an electrical connection between the structure intended for cathodic protection and foreign metallic structures. Separates the anode from the cathode by electrically isolating the two structures. Reduces the required amount of corrosion materials to be used. If a connection between the two structures exist then any cathodic protection system applied to one structure will try to protect the other as well and require more current. The design of the system will change requiring more anodes or material.

Insulator – FRP’s There are a variety of types of FRP’s. Flat FRP’s are a practical way of physically separating two buried structures especially in an excavation situation. FRP’s can be used above and below ground. The flat boards can be sized by cutting the board to the desire dimensions.

Insulator – FRP’s Some FRP’s are attached to the structure with an epoxy adhesive sealant, this helps mitigate crevice corrosion from taking place between the FRP and the pipeline. Best practice – apply a coating between the FRP and the pipeline, petrolatum tape works great in this application. Another type of installation involves applying a petrolatum tape material between the FRP and the pipeline to mitigate crevice corrosion.

Insulator – FRP’s FRP’s are an excellent material to be used on bridge crossings or other aboveground pipe supports. You do not want the pipe to short out with the bridge or other metallic structures due to a corrosion cell will form. Courtesy of Glass mesh

IR Coupons Benefits of using coupons Obtain IR drop free potentials Two no. 12 stranded wires. Benefits of using coupons Obtain IR drop free potentials Especially on systems that the current source can not be interrupted. AC measurements such as AC current density calculations. AC coupons will be covered in the AC interference class in the intermediate section later on. Surface area = 1.34 in2

IR Coupons The coupon needs to be of the same material as the pipeline in order to represent it accurately.

IR Coupons Need to have the coupon close to the pipeline (normally within 4” to 12”, buried in the same native soil as the pipeline.

IR Coupons You don’t want to shield the coupon or the coupon too close to the surface of the pipeline, at the same time, you want the same environment as the pipe as possible. Best practice is to place the coupon about mid way of the pipeline on the side.

IR Coupons Connect the coupon in the test station by bonding to the pipeline. The coupon will receive the same cathodic protection current as the pipeline.

IR Coupons The coupon represents a holiday area of the pipeline. The cathodic protection system (CP) protects the holiday areas of the pipeline, by bonding the coupon to the pipeline, the CP will polarize the coupon as well. We can remove the IR drop and find the true polarization on the pipeline by separating the connections and taking an instant-off structure-to-electrolyte potential measurement.

IR Coupons Test Station Bond or Switch The blue wires identify the lead wires used to electrically bond the coupon to the pipe. V Connect the voltmeter to the non-current carrying lead wire from the coupon. Pictures illustrates the wire configuration of connecting the coupon and testing with a volt meter & copper-copper sulfate half cell. The bond can be a mechanical switch or a bonding bar that can be disconnected very quickly. Coated pipeline Coupon

IR Coupon - Measurements Allow the coupon to polarize by electrically bonding the coupon to the structure in the test station. Disconnect or interrupt the coupon from the structure. Obtain structure-to-electrolyte potential measurements of the coupon, current applied and momentarily interrupted. The potential readings will be IR-drop free and will represent the pipeline’s IR-drop free potential readings. Normally disconnection is made by some type of a switching device set up in the test station box. The coupon normally has two wires connected, one for the bond and the second wire for connecting the volt meter. When the switch is thrown to an open status, then the disconnection is made, the reading can be obtain instantly with the volt meter and half cell already connected to other connecting wire.

Material Summary Test stations – Anodes Above ground Tri-view Flex Gerome for multiple wire connections such as bonds Anodes Connected in the test station box Get soil resistivity in designing Use anode calculation spread sheet 17lb – CP remediation and new coated steel pipeline 9lb – Bare pipe – leak repairs 3lb – customer service lines 1.5lb – drive in anodes – isolated metallic coated risers

Material Summary Insulators Below ground – Zunt Monolithic Weld-in Above ground – M&R – flange insulated kits Insulation made inside a building (M&R) Zinc grounding cell installed Always place a test station at insulation Always insulate casings and fill

Material Summary Coatings All coating applications transmission class Powercrete – 50 mil – directional boring Powercrete – 70 mil – rocky directional boring Powercrete – 50 mil – bridge crossings and/or any exposures 10 mils of polyurethane top coat FBE – only use dual coat applications of 32 to 35 mils Extruded used primarily as direct bury applications Use for stray current surroundings AC or DC All coating applications transmission class Inspected at the coating mill

Any Questions? Thank You