Medical Product Safety Network Improving Patient Safety by Reporting Problems with In Vitro Diagnostic Devices.

Slides:



Advertisements
Similar presentations
CAP/POCT 2003 Carol Riley-Hunte, RRT Senior Education Specialist Bayer HealthCare.
Advertisements

The Basics of Patient Safety How You Can Improve the Safety of Patient Care.
© Safeguarding public health Adverse incident reporting now and the future, roles and responsibilities Mark Grumbridge.
Optional, EMT. Course Objectives Indications for Use Proper Technique Pitfalls and Troubleshooting.
Project What is a project A temporary endeavor undertaken to create a unique product, service or result.
IVD and Point of care testing
Susan Best, NRL, Australia WHO post-market surveillance for In Vitro Diagnostic Devices (IVD)
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download, adapt, and distribute this.
ICASAS305A Provide Advice to Clients
Capturing and Reporting Adverse Events in Clinical Research
The Nature of Errors Richard M. Satava, MD FACS Professor of Surgery University of Washington School of Medicine and Program Manager, Advanced Biomedical.
Software Development Problems Range of Intervention Theory Prevention, Treatment and Maintenance Planning, Development and Use Cost of Intervention.
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download, adapt, and distribute this.
Quality Control Barbara Weberman MT(ASCP) Oakland County Health Division Laboratory Supervisor.
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
Medical Product Safety Network Improving Patient Safety by Reporting Problems with Medical Devices.
Medical Product Safety Network Improving Patient Safety by Reporting Problems with Medical Devices Used in the Home.
Medical Product Safety Network Improving Patient Safety by Reporting Problems with Medical Devices.
Quality Assurance in the clinical laboratory
4. Quality Management System (QMS)
The most precious commodity in your organisation?
Unit #7 - Basic Quality Control for the Clinical Laboratory
JOB HAZARD ANALYSIS Example Guide.
Virtual Health & Safety Management System (VHSMS) A Brief Guide for Head Teachers.
Leaders Manage Daily Operations
Recommended by the Sentinel Event Alert Advisory Group NATIONAL PATIENT SAFETY GOALS FY 2009.
Module 5Slide 1 of 24 WHO - EDM Part One, Sections 6 and 7 Basic Principles of GMP Complaints and Recalls.
A royal decree was issued on Feb.13, 2007 assigned the responsibility for regulating medical devices, in vitro diagnostic devices, prescription eye glasses,
1 Accreditation and Certification: Definition  Certification: Procedures by which a third party gives written assurance that a product, process or service.
Department of Quality and Regulatory Affairs Barbara Ann Karmanos Cancer Center 2009 The Karmanos Cancer Center Quality, Patient Safety, and Performance.
Module 5: Assuring the Quality of HIV Rapid Testing
Quality Directions Australia Improving clinical risk management systems: Root Cause Analysis.
Patient Identification & Specimen Collection How Proper Patient Identification and Proper Specimen Collection Affects the Accuracy of Your Patient’s Laboratory.
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Public ITE PC v4.0 Chapter 4 1 Chapter 4: Basics of Preventive Maintenance and Troubleshooting IT.
Preventing Surgical Complications Prevent Harm from High Alert Medication- Anticoagulants in Primary Care Insert Date here Presenter:
PROPRIETARY NAME EVALUATION AT FDA Jerry Phillips, RPh Associate Director for Medication Error Prevention Office of Drug Safety December 4, 2003.
Occurrence Reports. An occurrence report is a document used to record an event when it occurs Occurrences are reported each time an occurrence occurs.
Comcare Compliance Assistance Section Presents Incident Notification.
Quality Control Lecture 5
Quality Assurance Positive Outcomes for Negative Events Quality Assurance monitors operational systems:Pre-analytical AnalyticalPost-analytical Tools Used:
Incident Management Training
Leukocyte-Reduced Blood Components Lore Fields MT(ASCP)SBB Consumer Safety Officer, DBA, OBRR, CBER September 16, 2009.
This class cannot be shared or copied without the written permission of PracticeWorks Systems, LLC.
IT Essentials: PC Hardware and Software v4.0. Chapter 4 Objectives 4.1 Explain the purpose of preventive maintenance 4.2 Identify the steps of the troubleshooting.
Step What happens?. Who is responsible? Procedures needed?
Disclosure of Medical Errors AND Risk Management
Occurrence Reports. An occurrence report is a document used to record an event when it occurs Occurrences are reported each time an occurrence occurs.
Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015 Introduction to Quality Control.
Electromagnetic Interference (EMI) in the Hospital Lake Regional Health System.
RISK MANAGEMENT Kansas Spine & Specialty Hospital Annual Competency 2016.
Laboratory equipment Dr. W. Huisman Cairo, November 21th 2012.
George E. Detsis Manager, Analytical Services Program United States Department of Energy Office of Health, Safety and Security Office of Sustainability.
CLINICAL LABORATORIES THE ROLE: A science that uses sophisticated instruments and techniques with the application of theoretical knowledge to perform complex.
Complaint Handling Medical Device Reporting May 19, 2016 Rita Harden, Director Customer Relations & Regulatory Reporting.
Computer Security: Principles and Practice First Edition by William Stallings and Lawrie Brown Lecture slides by Lawrie Brown Chapter 17 – IT Security.
Storage, Labeling, Controlled Medications Guidance Training CFR § (b)(2)(3)(d)(e) F431.
QC - THE OUT-OF-CONTROL PROBLEM 謝 昆 穎 Assistant Product Manager, CDG BIO-RAD Laboratories, Taiwan Branch.
Medical Product Safety Network (MEDSUN) an Interactive Surveillance System: Eliminating Barriers to Reporting and Creating Two-Way Communication with FDA.
Quality Assurance Procedure Manuals.
The Working Group on Medical Measurements The 23rd Forum Meeting
Unit #6 - Basic Quality Control for the Clinical Laboratory
Ensuring a safe workplace
An Integrated Risk Management & Safety Program: IRMSP
Proficiency Testing as a quality improvement tool
Instrument Maintenance
Provider Initiated HIV Counseling and Testing
Medication Safety Dr. Kanar Hidayat
Complying With CLIA Competency Requirements
Quality Control Barbara Weberman MT(ASCP)
Medication Safety Dr. Kanar Hidayat
Presentation transcript:

Medical Product Safety Network Improving Patient Safety by Reporting Problems with In Vitro Diagnostic Devices

Reporting Problems with In Vitro Diagnostic Devices (IVDs) At the end of this session you will be able to: 1. Identify several types of IVDs 2. Explain why reporting problems with IVDs is important 3. Describe your role in promoting patient safety with IVDs 4. Describe the steps to take to report an adverse event or problem with IVDs in our hospital

Types of IVDs and Examples Capital Equipment large automated analyzers, microscopes, and centrifuges Instruments glucose meters, bench top analyzers, pipettors/dispensers Reagents laboratory test kit components (e.g. antigens, monoclonal antibodies), single use devices (e.g. pregnancy tests, rapid flu tests), quality control (QC) materials Disposables & Accessories blood collection tubes, cuvettes, pipettes, test tubes, latex gloves Computerized Medical Systems laboratory information systems

“Medical errors most often result from a complex interplay of multiple factors. Only rarely are they due to the carelessness or misconduct of single individuals.” Lucian L. Leape, M.D. A leading patient safety expert from Harvard University

Where Laboratory Problems Can Occur Pre-Analytical Phase Sample collection (ex. wrong anticoagulant used) Sample processing (ex. inappropriate storage) Patient status (ex. fasting/non-fasting) Analytical Phase Inadequate instrument maintenance Calibration problems Quality control trends of shifts Post-Analytical Phase Errors in reporting results Delays in calling panic values

Error Reduction Example: Automated Laboratory* Prepare analyzers (calibration) Review quality control values (QC in/out of range) Analyze samples (label applied correctly) Review results (review limit flags) Release results (check for change of status) Report results *Riebling N, et al, Six Sigma project reduces analytical errors in an automated lab, Medical Laboratory Observer, June 2005

Staff Think About the IVD and its Environment Environment Electric Power, Heat, Humidity, Light, Other Devices (EMI) Accessories & Disposables Test Strips Lancets Control Solution

What Types of IVD Problems Should I Look for? Instructions/labeling/packaging Defects Software problems Failure to work as intended/malfunction Interactions with other devices Use errors related to poor design of the IVD Manufacturer is unresponsive to feedback or slow to notify the lab about problems Combinations of the above

Examples of Problems Instructions/Labeling/Packaging procedural steps are missing or confusing reagents are mislabeled sterile packaging is compromised sample type is not specified test limitations are not clear operating temperature is not specified unclear diagrams for test interpretation of a positive/negative result

Examples of Problems (continued) Defects pipettor delivers short samples or jams repeatedly repeated malfunctions occurring on the same analyzer frequent instrument breakdowns (hardware failure) negative control line reads positive for all samples contaminated reagents

Examples of Problems (continued) Software problems problems with the interface between the instrument software and the hospital’s Information System software upgrades change performance of the assay (e.g. assay cut-off) virus infects device operating software

Examples of Problems (continued) Failure to work as intended/ malfunction blood collection tube has inadequate vacuum package insert performance claims not met quality control materials give unacceptable results leading to invalid/unreportable patient results external liquid control results do not match built-in control results for a single use device

Examples of Problems (continued) Interactions with other devices electromagnetic interference (e.g., cell phones, pagers, etc.) cause lab instruments to give erroneous results instrument components are not communicating with each other

Examples of Problems (continued) Use Errors poor instrument design/poor instructions that leads to user confusion and error lab test used for another purpose, e.g., testing pediatric samples when performance claims are based on adult testing

Why Reporting Problems With IVDs Is Important In Our Hospital Prevent future problems and protect our patients, staff, families, and visitors Other users may be having the same problems Achieve performance improvement goals Assist Risk Management with claims or litigation Provide information to manufacturers and/or U.S. Food and Drug Administration Impact the public health for the nation’s patients and/or health care providers Effect changes in policies and procedures

When Do I Report? When you think an IVD has or may have caused or contributed to any of the following outcomes (for a patient, staff member or visitor): death serious injury minor injury close calls or other potential for harm

What Do We Mean by “Potential for Harm?” Events that are caught before anything harmful occurred false positive or negative results were identified before results are reported Important observations of a chronic problem with an IVD instrument needs calibration more often than recommended in order to obtain correct results Problems which lead staff to develop “work-a- rounds” software error messages that staff override “Out-of-the-box” problems that are identified before the IVD is used contaminated reagents

What Do I Report? If there was an injury, what happened to the persons affected? hemorrhage from excessive anti-coagulant therapy What were the problems with the IVD involved? recurrent failed runs What, if any, were the follow-up medical procedures required because of the event? hospitalization What are the names of the manufacturers and/or distributors of the IVDs involved? What are the relevant manufacturer device identification numbers? serial, model, lot, catalog, and any other specific information What did you do to solve the problem?

How Do I Report? Our Reporting System Involves... (Customized responses would be listed below) Online reporting system via hospital intranet Verbal or written reporting to supervisor Written acknowledgment to the reporter including any follow up actions Reward system for “best catches” that make patient care safer

When You See an IVD That Presents a Problem You Should... (Customized responses would be listed below) If possible, determine whether the problem was related to an instrument, reagent, or instructions for use Return unused reagent vials, test packs, etc., to the manufacturer for investigation of the problem Do not report patient results if the quality control materials give unacceptable results Report even minor reagent or instrument problems Save the device and packaging and put it in a clear plastic bag

Some Issues We’ve Addressed at Our Hospital What Was Reported... (Customized responses to appear below) Analyzer giving erratic results Contaminated reagents Instrument pipettor continually out of alignment What We Did... (Customized responses to appear below) Found the source of electromagnetic interference, removed it and reported to MedSun Contacted manufacturer who replaced the reagents; reported to MedSun Called the manufacturer who installed a new pipettor; reported to MedSun

Some Issues We’ve Addressed at Our Hospital Cont’d What Was Reported... (Customized responses to appear below) Reagents outdated when received Calibration successful but controls out What Was Reported... (Customized responses to appear below) Contacted the manufacturer and was instructed to extend the date and still use the reagents; reported to MedSun Contacted the Hotline. Instructed to open new lot of controls; reported to MedSun

Fostering a Climate of Patient Safety (Customized responses would be listed below) Feedback and communication Learning from errors Compliance with policies and procedures Teamwork

If You’re Not Sure What or How to Report (Customized responses would be listed below) Refer to the incident reporting section in our Policy and Procedures manual Ask your supervisor, or Call our reporting hotline at extension _____

Your Role Identify actual and potential problems, adverse events, close calls with In Vitro Diagnostic devices Report the problem or adverse event to your supervisor, according to policy and procedure Make sure your report includes details Remove the device and save the packaging Return to the manufacturer for evaluation if possible

In Summary... Our objectives were to: 1. Identify several types of In Vitro Diagnostic Devices (IVDs) 2. Explain why reporting problems with IVDs is important 3. Describe your role in promoting patient safety with IVDs 4. Describe the steps to take to report an adverse event or problem with an IVD in our hospital Have we met them?

And Remember... We can’t address issues we don’t know about. Please report.