Lecture 10 Dimitar Stefanov. LOWER-EXTREMITY PROSTHESES socket residual limb (soft tissue and bones) (individually fitted component) Example.

Slides:



Advertisements
Similar presentations
Knee-Ankle-Foot Orthoses (KAFOs)
Advertisements

Prosthetic Gait Deviations
TF SOCKET BIOMECHANICS
Bryan Humble CPO/LPO Precision Prosthetics
Ankle-Foot Orthoses (AFOs)
Using assistive gait devices in rehabilitation.  Reasons for using an assistive gait device are:  Poor balance,  Inability to bear weight on a lower.
1 International Committee of the Red Cross Polypropylene Technology Manufacture of Lower Limb Prostheses in PP TF STATIC ALIGNMENT.
VARIABLE CADENCE KNEES Overview and Brainstorm of Training Strategies Tony Fitzsimons Peter Spooner-Hart Dr Ian Jennsen.
ASSESSMENT CHAPTER 6. Physical assessment PHYSIOTHERAPY ASSESSMENT session CHAPTER 6 PART
Andreas Kannenberg, MD PhD, Director Medical Affairs
Renee Kitto Port Macquarie Base Hospital
Normal Gait.
Phases of the Gait Cycle And Determinants of Gait
17/07/1436RHS 4221 Dr. Afaf A.M Shaheen Lecture 4 RHS 422.
Check-out procedure (PP Lower Limb Prosthesis) Polypropylene Technology International Committee of the Red Cross.
ESS 303 – Biomechanics Ankle and Foot. Tibiofibular Joint Similar to radioulnar joint Superior tibiofibular joint Middle tibiofibular joint (interosseus.
Stair Gait Lecture Notes.
Gait Deviations and Prosthetic Knee and Feet Systems
Gait.
Biomechanics of Walking for People with Lower Extremity Amputations
Thornbers Podiatry “Promoting optimum health and performance”
Biomechanics- Gait.
Lower Limb Prostheses Description
Gait Analysis Study of human locomotion Walking and running
Biomechanics of Gait Walking
NATURAL GAIT INDUCING TRANSTIBIAL PROSTHETIC LUCIA MELARA ROBERT SCOTT ALEXIS GARO EML 4551 ETHICS AND DESIGN PROJECT ORGANIZATION FIU DEPARTMENT OF MECHANICAL.
Determinants of Gait Determinants of Gait.
No More Peg Legs and Hooks Better Prosthetic Design through Engineering.
OTTO BOCK 3R80 Hydraulic Knee
1 Gait Analysis – Objectives To learn and understand: –The general descriptive and temporal elements of the normal walking movement –The important features.
Gait Analysis – Objectives
PROSTHESIS MUHAMMAD FARRUKH BASHIR FCPS(ORTHO) MUHAMMAD FARRUKH BASHIR FCPS(ORTHO)
Analysis of Movements Revision Lesson
Biomechanics of the hip Prof. Sung-Jae, Lee Ph.D Inje Univ.
2 Influences on Flexibility Flexibility is an important part of health-related fitness. Flexibility A joint’s ability to move through its full range of.
Preventing Musculoskeletal Injuries at KGH. Kingston General Hospital is committed to providing a safe and healthy work environment for you and your coworkers.
Building a Better Runner.  Maximal Oxygen Consumption (VO 2 MAX )  Lactate threshold (LT)  Running speed  Running economy Performance Velocity Resistance.
Gait development in children. The prerequisite for Gait development Adequate motor control. C.N.S. maturation. Adequate R.O.M. Muscle strength. Appropriate.
By Chun-Lung Lim Jay Hatcher Clay Harris. Humanoid Robotic Hardware Biped Humanoid Robot Group - Kato/Takanishi Laboratory & Waseda University WABIAN-2.
Technologies For Your Smile Advanced 6-Bar Mechanism Stance-Flexion, Adjustable Geometrical Lock System p- MRS system Manual Lock CONFIDENTIAL NK6 + L+
Courcey Rovers FUNdamental Movement Skills U6 – U12.
Pneumatic system. It is important to know that we are working with compressed air and not with a fluid like at hydraulic systems. Pneumatics is when compressed.
The Gait Cycle:.
Chapter 9 Evaluation of Gait. Introduction Gait Analysis – functional evaluation of a person’s walking or running style Systematic method of identifying.
Science Project Running and Running Shoes Micah Hinson.
Prosthetics-P101. Prosthetic Objectives Amputee perspective Prosthetic process – Existing amputee v. New amputee Component selection criteria – Suspension.
The MIT Leg Lab: From Robots to Rehab.
Improved Lower Limb Prosthesis
THE FUTURE OF TOMORROW TODAY
 Support Events  Foot (Heel) Strike  Foot Flat  Midstance  Heel Off  Foot (Toe) Off  Swing Events  Pre swing  Midswing  Terminal swing.
2 What You Will Do Identify factors that can positively or negatively influence your flexibility. Apply the biomechanically correct use of leverage to.
Part 1: Assessment for Prosthetic Use & Stump Management.
Lower Limb Prostheses May 3rd, 2012 Emily Harnden.
1 Gait Analysis – Objectives To learn and understand: –The general descriptive and temporal elements of the normal walking movement –The important features.
Prosthetics & Orthotics 단국대학교 일반대학원 물리 · 작업치료전공 강권영.
Date of download: 7/6/2016 Copyright © ASME. All rights reserved. From: A Universal Ankle–Foot Prosthesis Emulator for Human Locomotion Experiments J Biomech.
Upon completion of this lecture student will be able to:  Identify different parts of transfemoral prosthesis.  Differentiate between Quadrilateral.
Prosthetics and orthotics
Ambulation & Assistive Devices
Running Gait.
Prosthetic limbs.
Date of download: 10/23/2017 Copyright © ASME. All rights reserved.
Date of download: 10/25/2017 Copyright © ASME. All rights reserved.
Bare weight Provide a means for locomotion Maintain equilibrium
Date of download: 1/3/2018 Copyright © ASME. All rights reserved.
Normal Gait.
Kinematic effects on gait of a newly designed ankle-foot orthosis with oil damper resistance: A case series of 2 patients with hemiplegia  Osamu Yokoyama,
Assistive gait devices in rehabilitation
Transtibial Amputee Human Motion Analysis
Human Gait Analysis using IMU Sensors
Presentation transcript:

Lecture 10 Dimitar Stefanov

LOWER-EXTREMITY PROSTHESES socket residual limb (soft tissue and bones) (individually fitted component) Example

In case of partial amputation, inserts within a conventional shoe are can be applied. Energy-stored feet. In general, it is realized via flexible keel, which provides non-linear spring action similar to the push-off phase of walking or running. DYNAMIC RESPONSE FEET The distinguishing characteristic of this group is a plastic spring mechanism in the keel which deflects during heel off and returns to its resting position during toe off. Often called "energy storing" by manufacturers, these feet provide a subjective sense of push-off for the wearer, a more normal range of motion, and a more symmetric gait. SINGLE-AXIS FOOT Single axis solid ankle cushioned heel (SACH) prosthetic foot – provides planar flexion and smooth transition to mid-stance; increased knee stability; best suited for short-term use, such as on preparatory devices or for elders who may walk with a shuffling gait and never fully load the forefoot.

In case of partial amputation, inserts within a conventional shoe are can be applied. Energy-stored feet. In general, it is realized via flexible keel, which provides non-linear spring action similar to the push-off phase of walking or running. DYNAMIC RESPONSE FEET The distinguishing characteristic of this group is a plastic spring mechanism in the keel which deflects during heel off and returns to its resting position during toe off. Often called "energy storing" by manufacturers, these feet provide a subjective sense of push-off for the wearer, a more normal range of motion, and a more symmetric gait. SINGLE-AXIS FOOT Single axis solid ankle cushioned heel (SACH) prosthetic foot – provides planar flexion and smooth transition to mid-stance; increased knee stability; best suited for short-term use, such as on preparatory devices or for elders who may walk with a shuffling gait and never fully load the forefoot.

Multi-axis foot Swim prostheses The Jaipur foot inexpensive prosthetic foot – India Made of vulcanized rubber Wooden keel Consists of three inserts: fore-foot and heel of micro cellular rubber and an ankle of laminated wood Flexibility in three planes Well suited for walking over uneven terrain, climbing trees, etc.

Below-the-knee prosthesis Important problems: design of convenient socket; prevention of pistoning; reduction the forces on the residual limb; large contact area between the distal end of the limb and the socket. Suspension through latex rubber sleeves and a waist belt attached to a cuff. CAD-CAM design can be applied in the socket production. The wire-frame model representation of the socket should be viewed by the prosthetist and modified.

Above-the-knee prostheses Knee joint – much important component It should be lightweight and safe in operation. Design solutions of knee joint: A./ Simple mechanical device with manually operated locking mechanism. Disadvantages: Low functionality useful for sitting only doesn’t allow bending during the swing phase. B./ Mechanical devices that allow knee to flex when it is unweighed and which lock when a weight threshold is exceeded. Solutions for activation of the knee lock: Pressure of the heel Ankle flexion

C./ Hydraulic knees – They allow stance and swing phase control; Adjustment of the swing phase to suit to individual’s pattern of walking. Hydraulic resistance to flexion; Lock of the knee joint in hyperextension; Unlock the joint when the forces to the prosthetic forefoot exceed a threshold; Manual lock for activities which require maximal stability (driving an automobile, standing on a bus, vocational activities); Release for maximum flexibility.

Solutions: Piston and a hydraulic cylinder.Piston and a hydraulic cylinder. The cylinder is perforated to allow fluid to flow from one side of the cylinder to the opposite side when the piston moves. The distribution of the holes within the cylinder determines the amount of damping. Hydraulic cylinder and piston.Hydraulic cylinder and piston. Holes on the cylinder ends and electromagnet- controlled valve which determine the fluid flow. Microprocessor control unit and a hall-effect sensor for knee-bending measurement.

Otto-Bock knee prostheses: An optimal gait pattern is achieved by adjusting the independent swing phase flexion and extension resistances 3R45 Modular Knee Joint integrated miniature hydraulic cylinder

3R80 Modular Rotary Hydraulic Knee Joint Weight activated; Cadence responsive; Precise adjustability; 135 degree flexion angle; Independently adjustable hydraulic flexion and extension resistance.

Pneumatic cylinder and a swing-phase controller.

The Endolite intelligent prosthesis Swing-phase controller (control in different cadences) 4-bit microprocessor which controls a needle valve, via a stepper motor The controller is programmed (by the prosthetist) to provide an optimal damping in different walking patterns.

Prosthetic gait analysis and assessment Harmless prostheses design – to minimize the risk of injury associated with stumbling, slipping and falling. Prosthethic limbs do not provide direct proprioceptive feedback. Some force information is transferred to the user via the socket. Often prostheses produce sound or vibrations that change with the force and cadence. People with lower-limb prostheses use a higher oxygen consumption, which varies to the different model prostheses. Biomechanical techniques for assessment the adaptation of the user to the lower-limb prostheses: gait analysis, force-reactions measurement.

Lower-extremity orthoses Orthosis design: The ankle is treated as a joint with a single DOF The knee joint is modeled with two DOF joint (flexion/extension in the sagital plane and rotation in the transverse plane) The hip is modeled with a joint with 3 DOF (abduction/adduction in the frontal plane, flexion/extension in the sagital plane, and internal/external rotation). Mechanically strong – static and dynamic loads. Walking stability and prevention of falling. The sensory feedback to the user contributes the stability increase. Applied in case of lower limb paralysis

Mechanical ankle-foot orthosis Vanini-Rizzoli Stabilizing Limb Orthosis (VRSLO) The polypropylene orthosis is inserted into a specially designed leather boot. The insole of the orthosis is angled to provide 10 to 15 degrees of planar flexion. Attempt for development of lightweight, simple and easy to use otthosis. Ankle-foot orthosis Designed of molded plastic or metal Foot design – very important (heel high)

Three classes devices for movement of paralyzed legs: Purely mechanical orthoses Hybrid devices (mechanical support + FES) FES alone. Knee-ankle-foot orthoses –very high energy-costs during use due to poor biomechanical efficiency. Heavy, bulky, and bad cosmetically looking