Digital Data Management For Coating Inspection Tasks On Steel Structures Presented by: Joe Walker, Elcometer.

Slides:



Advertisements
Similar presentations
DLS VERIFICATION TESTING FIELD TESTS TO CHECK DLS OPERATIONS.
Advertisements

SSPC PA-2 “Measurement of Dry Coating Thickness with magnetic Gages”
Work Smart. Is our vessel ready on site Or has there been a delay.
STOCK CONTROL Inventory is often referred to as the graveyard of business because over investment in stock is a frequent cause of business failure.
Preparing a Coating Inspection Plan
Presented by: Derrick Castle, PCS Kentucky Transportation Cabinet Writing a Good Specification for Bridge Painting.
Calculating Coating Lifetime Costs
Global Supplier Quality Manual PPAP Requirements
PPAP Requirements Training
Steps to a More Effective Power Tool Cleaning Presented by: Earl Bowry, Jotun Paints, Inc.
A VISUAL AID TO PYROMETRY COMPLIANCE (A Guide To An Acceptable TUS Report) February 2010.
First Article Inspection Report
Concrete Cleanliness Inspections – Extent of Paint Removal For repaints, verify adequacy of paint removal Definitions for the amount of paint or stain.
Variation Management of Key Characteristics
William D. Corbett, KTA-Tator, Inc. Chair – SSPC Committee C.3.2 on
Scrap Yard Application Act Requirements Typical Current Processes Our Proposed Processes (Totally Customizable) Benefit of Proposed System Demonstration.
SAE AS9100 Quality Systems - Aerospace Model for Quality Assurance
What Is A Computer System?
Quality Management System
Relevance of Ambient Conditions Temperature/humidity restrictions often ignored Air and surface temperature can be too hot or too cold for proper film.
William D. Corbett KTA-Tator, Inc.
Surface Preparation - QA Assessments (con’t)
Practical Coating Thickness Measurement Overview Presented by: Paul Lomax, Fischer Technology, Inc.
Presented by: Skip Vernon, Coating and Lining Technologies, Inc. How to Update and Develop an Effective Coating Specification.
Latest Advances in Dry Film Thickness Measurement Techniques
Adhesion Testing for Protective Coatings
Asset Management Preservation
Quality Assurance/Quality Control Policy
Examine Quality Assurance/Quality Control Documentation
ISO 9000 Certification ISO 9001 and ISO
MSQ Materials Analysis Software. MSQ TM Software The Image Analysis Solution for Metallographic and Materials Science Quality Control. MSQ increases productivity.
First Article Inspection
Understanding the National Dairy Herd Improvement Program Uniform Operating Procedures (Code of Ethics & Uniform Data Collection Procedures) April 2014.
BRC Food Safety Quality Management System Training Guide
Presented by: Peter Emmons,
Labeling and Program Delivery Division USDA, FSIS, OPPD
24/03/2006 Introduction to IMO Performance Standard for Protective Coating and IACS Common Structural Rules BV Surveyor’s Training Development Department.
“We Bring Engineering to Life” U.S. Tobacco GAP – Barn Testing Procedure.
1 Anti-fouling Systems—Survey and Certification Huang Tianbing Marine Biosafety Section Bangkok, June 2009 Views expressed in this presentation are those.
How to use it to Reduce Life Cycle Costs
Client Name is.... Dr Lynda Speed
Presented by: Tony Serdenes, Greenman-Pedersen
Presented by: David Beamish DeFelsko Corporation
Chapter 20 Measurement Systems. Objectives Define and describe measurement methods for both continuous and discrete data. Use various analytical methods.
PSPC/Coating Technical File (CTF)
Verification & Validation. Batch processing In a batch processing system, documents such as sales orders are collected into batches of typically 50 documents.
Application of Thermal Spray
Standards, Training, and Certification in the Wastewater Industry Presented by: Bob Murphy, Sherwin Williams.
IGCSE ICT Stock Control.
Webinar FSSC audit report 7th september 2015
Master Formula And Batch MaNUFACTURING Record
Standards, Training, and Certifications in the Marine Coatings Industry Presented by: Earl Bowry.
Lesson Two Ship Design. Contents Design essentials Design Procedure advances factors concepts requirements Detailed operation.
COATING STANDARD Primary surface preparation
Coating Defects and Failures
Welcome to the FSSC Global Markets Webinar 11 September 2017, 4pm CET
Measuring Dry Film Thickness (DFT) on Concrete Substrates
AND AFTER INSTALLATION Technical Director, NASSCO
Inspection of Thermal Spray Coatings
First Article Inspection
ISO 9001 Awareness Training.
First Article Inspection
AS 9100 Awareness Training.
John Kern SSPC Technical Services Dept.
Quality Control Instrumentation for Paint and Coating Installations
Supplier Briefing Pack
Instruments & Electrical Measurements Lecture 4
William Corbett, Carly McGee and Jason Coley KTA-Tator, Inc.
Bob Cloutier, for SSPC Technical Services Dept.
Fiber Reinforced Polymer Systems
Presentation transcript:

Digital Data Management For Coating Inspection Tasks On Steel Structures Presented by: Joe Walker, Elcometer

Learning Outcomes Define digital data management Define key sections where project information is recorded within a digital data management software package Define surface profile, ambient conditions, and dry film thickness Recognize how to perform profile, ambient conditions, and dry film thickness measurements

Introduction Optimum corrosion protection and rigorous inspection is required – on both new build and existing structures Protective coating maintenance costs for steel structures continue to rise Accurate records of inspection measurements and procedures provide assurances to the owner or the purchaser that the coating is being applied properly

Inspection Independent inspection provides quality assurance to the owner The time needed to perform quality inspections will impact overall project Inspections are necessary to meet the required standard

Inspection The key therefore is to minimize the time spent writing the reports, so more time can be spent inspecting This is where digital data management comes in

What is Digital Data Management? What are the issues? Not all inspections are with digital gauges Surface condition – SA2½ Surface cleanliness soluble salts beading weld spatter Surface contaminants Oil, grease, dust abrasive inclusions Edge radii Surface profile Climate conditions Dry film thickness Film continuity Damage & inclusions Some use ‘mark 1 eyeball, others mechanical, and some have a digital display but no data output or memory

Digital Data Management Software for Inspection Advantages: Significantly speeds up measurement and recording time- by as much as 70% Minimizes (and in most cases removes) human error- transcribing or keying in errors Reduces paperwork Provides real time inspection data to the customer

What is Digital Data Management? Digital Data Management comes in many forms: Hand written reports – scanned into the computer and stored Hand written reports – manually keyed into the computer Inspections using digital test equipment and downloaded into a computer Inspections carried out using a PDA and digital test equipment emailed to the PC Total paperless QA – with inspection task planning

Total Paperless QA Provides a framework for planning and recording coating inspection tasks Provides a single point of reference for all coatings applied – and in which location Provides a daily activity log Generates a complete inspection report – automatically Provides an electronic method for recording both digital and non-digital inspections Maximises inspection time

Using Digital Data Management Provides a framework for planning and recording these coating inspection tasks on large projects.

Key Components of Digital Data Management Software A coating library Defined coating systems used throughout the structure A register of inspectors and their certifications (e.g. PCI and NBPI) A list of individual inspection check/hold points Details of the structure being coated (including drawings) A list of individual inspection tasks, along with areas to record results and links to rework A daily log that contains inspection information recorded by the system administrator

Coating Library Repository of information from the manufacturer’s product data sheet Manufacturer Product name Product ID Specified wet film thickness/dry film thickness Specified surface profile Ambient conditions for application

Defined Coating Systems Unique IDs in the coating library tying each coating system to structure area

Defined Coating Systems: Application Once the coating system’s unique identification is created, the steps for proper coating application are specified

Register of Inspectors Holds the records for approved inspectors: Photograph of inspector Copy of inspector’s certificate Record of certificate expiration date Details of where inspector has permitted access

Inspection Regime Area in the digital data management system that groups inspection check points together, for example: Surface Preparation Check Points Removal of oil and grease Removal of surface contaminants Surface profile Abrasive cleanliness Cleanliness of abrasive blasting air

Steel Structure Details A record of the steel structure and steel parts Provides a basis for planning the job and inspection tasks

Steel Structure Details Example: Ship Structure Record of: Hull number/IMO number Customer’s name Ship’s name Contract date Keel-laying date Planned launch and delivery dates Gross tonnage Deadweight Length of ship The beam The draft and depth

Steel Structure Details Store drawings of the structure as “jpg.” Highlight individual areas of the structure as part of the structure definition Assign the proper coating system to be applied to individual areas as well as the appropriate registered inspector

Steel Structure Details

Steel Structure Details

Inspection Tasks The inspection record (inspection tests and results) is created after the structure part, coating system, and assigned inspector are identified

Daily Log Documentation of inspection tests performed on a given day as well as any scanned documents Should include supporting photographs as well as measured data

Reporting Inspection Test Results Written on a hard copy printout of the inspection task Transferred electronically to a Smart Phone/PDA Entered directly into a computer

Reporting Using a Hard Copy Printout Finished written document is scanned to create an electronic file within the digital management software

Reporting Using a Smart Phone/PDA Transfers the inspection test results along with any photographs to the portable device

Reporting Using a Computer Enter testing results directly into the computer

The Three Digital Inspection Techniques Surface Profile Ambient Conditions Dry Film Thickness

Surface Profile The roughened surface that results from abrasive blast cleaning or power tool cleaning to bare metal A measurement of the peak-to-valley height of the surface roughness

Surface Profile ASTM D 4417, Standard Test Method for Field Measurement of Surface Profile of Blast Cleaned Steel Method B

Surface Profile ASTM D 4417, Method B The depth of profile is measured using a fine pointed probe at a number of locations and the average is determined

Ambient Conditions Weather conditions at a specific place and time or time period: air temperature relative humidity dew point wind velocity Monitored on the job site

Ambient Conditions Measured using: Electronic dew point meters

Ambient Conditions

Ambient Conditions Maximum relative humidity of 85% Surface temperature typically must be at least 5°F/3°C above the dew point in order for final surface preparation and/or coating work to begin or to continue

Dry Film Thickness Depth of cured film usually expressed in mils (0.001 inch) or microns (millionths of a meter)

Dry Film Thickness Measured with: Type II Gage (Non-Destructive)

Dry Film Thickness Gages

Dry Film Thickness Standards ASTM D 7091, Standard Practice for Non-Destructive Measurements for Dry Film Thickness of Nonmagnetic Coatings Applied to Ferrous Metals and Nonmagnetic, Nonconductive Coatings Applied to Non-Ferrous Metals

Dry Film Thickness: SSPC PA 2 Measurement of Dry Coating Thickness with Magnetic Gages Type II Gages Describes how many measurements to take in a given area

SSPC-PA 2 Provides guidance on: Frequency of verifying gage accuracy Frequency of measurements (number of measurements to obtain based on the size of the coated structure Places limits on thickness readings vs. specified thickness Procedures supplement manufacturers’ operating instructions but do not replace them

SSPC-PA 2 Gage Reading- a single reading at one point Spot Measurement- the average of at least three gage readings made within a 1.5 inch diameter circle

SSPC-PA 2 Make five separate spot measurements spaced arbitrarily over each 100 ft2 area to be measured For structures NOT exceeding 300 ft2, each 100 ft2 area shall be measured For structures NOT exceeding 1000 ft2, three 100 ft2 areas shall be arbitrarily selected

SSPC-PA 2 For structures exceeding 1000 ft2, the first 1000 ft2 shall be measured as stated in previous slide Each additional 1000 ft2 of area or increment thereof, one 100 ft2 area shall be arbitrarily selected

SSPC-PA 2

Conformance Minimum Thickness No single spot measurement in any 100 ft2 area shall be less than 80% of the specified minimum thickness Note- it is possible for any single gage reading to under-run by a greater amount

Conformance Maximum Thickness No single spot measurement in any 100 ft2 area shall be more than 120% of the specified maximum thickness Note- it is possible for any single gage reading to over-run by a greater amount

Summary Using digital data management can reduce time spent on the inspection process and overall project costs while providing an electronic record of the job in all its stages.

Conclusion This concludes our webinar for today. Please join us for our next webinar, Coating Selection for the Wastewater Industry on October 20th at 1 pm EST