A. Imaging sample: 1. Place sample on stage 2. Make sure sample does not interfere with C mirrors 3. Start “Sonic MyDVD” on both laser heating computers.

Slides:



Advertisements
Similar presentations
LOGGING ON AND SHUTTING DOWN How to do both successfully at school.
Advertisements

WISD Technology Services How to Hook Up the LCD Projector to your Laptop.
Data Projector Setting Up/Connecting Laptop & Data Projector.
CHDD BOL Equipment Primer Rooms CD 326 & CD 391 Behavioral Evaluation Center Behavior Observation Laboratory.
AV Operating Instructions
Presenting A Power Point Program. Computer Checklist Computer Checklist Power Cord Mouse Computer.
I TEC TRAINING This training session will explain how to use ITEC equipment and support learning in the classroom setting. Presented by: R. Schmid.
College of Education 103 Conference Room The Multimedia Podium.
Meridien Conference How-To Guide for Speakers Setting Up the Projector.
Smart Cart Multimedia Lectern Technology Resource Center.
Elementary Science Cart. 8 Laptops 1 Projector Computer to Projector Connect to laptop.
BACKEND MULTIMEDIA ROOM Home User Guide Computer Projector DVD/ VCR Remote Mouse Save tutorial on desktop to watch full screen. Click boxes to jump into.
Quick Operation Guide System Controller WV-CU650 Main Functions (1) WV-CU650 Start Up Login 1. Turn on the power and wait for the Login standby display.
Nikon Eclipse TE2000 Spinning Disc. inverted perfect focus microscope optimized for live cell imaging and time lapse movies Equipped for DIC, Ludl Piezo.
Mercury bulb Camera Microscope on/off Stage up/down Focus wheel Objective controls Fluorescence filter controls Mono/RGB.
Portable/Desktop Projectors Small and light, ideal projectors for transports.
The PHENIX/EMCal(PbSc)/BB/TOF Laser User Instructions Sean Stoll (rev. 12/8/03)
This is a guide for using the Zeiss LSM510 Confocal Microscope. Do not attempt to use this microscope without the proper training. If you have any queries.
Computer Basics. Using a computer The purpose of this class is to get comfortable with: Using Windows.
1. Pump down the chamber from the atmosphere pressure 2. Using RHEED to obtain diffraction images 3. Open the RHEED chamber or venting from high vacuum.
+ USING THE POWER CHARGER AND BATTERY MINI-DV CAMCORDER Connect the charger to the power cord Attach the battery to the charger Plug it in and watch for.
LCD Projector Set Up Instructions So, you want to set up the LCD projector, but you’re unsure where to start? Just follow these instructions…
Operation of the S4700 FESEM
+ USING THE POWER CHARGER AND BATTERY MINI-DV CAMCORDER Connect the charger to the power cord Attach the battery to the charger Plug it in and watch for.
CSE 595 Lab #1 Dodge Caravan Electronic Locking System Steve Pruitt Jan 13, 2000.
AUDIO VISUAL TRAINING Center for Academic Success.
A stereo dissecting microscope is normally used to view relatively large specimens at magnifications from about 5X to about 50X. The scope provides a very.
Paver System Five Control Box Overview Aug 2009 Control Box Overview Paver System Five.
Should be on Up to hear patient button presses Down to mute. In either case the #1 and #2 lights should light with each button press. Leave the 5 to the.
By: Arkida Merizaj and Imelda Mahmutaj.
Auto Focus. What is auto focus? The camera focuses the image 1.Autonomously (no photographer direction) 2.Photographer directed 1.Location in scene (focus.
Settings & Adjustments. Settings & Adjustments.
Student Support Services Laptop Workshop. What will you Find The actual Computer The Power Cord (Comes in two parts.)
Digital Camera Basics Misty Freeman Georgia CTAE Resource Network 2010.
How to Use Digital Blue QX5 (See separate powerpoint on the use of the software)
TPC/TRD DCS meeting, GSI, 27 Sep 2002Børge Svane Nielsen, NBI1 TPC laser system controls adjustable mirrors Laser Controls, Power, Cooling DCS: 1/ Laser.
PERKIN-ELMER MODEL 200 UV-VIS SPECTROPHOTOMETER OPERATING INSTRUCTIONS.
Mercury bulb Camera Microscope on/off Stage up/down Focus wheel Objective controls Fluorescence filter controls Mono/RGB.
Nikon Spinning Disk Imaging & Training Support. Find your cells with DIC in Live Preview 1.The green DIA Lamp, used for DIC, should be on. 2. Condenser.
Getting Started With the Dukane Document Camera. The Anatomy of a Dukane Document Camera AC In VGA Out Composite Video USB DVI Out DC Out Control Pad.
How To Log On the Computer At School A Tutorial for Preschoolers and Kindergarteners.
Subject 7: The lens-meter: Measuring Posterior Vertex Power. Description of the lens-meter Calibrating the instrument Measuring Posterior Vertex Power.
Lego MindStorm An Introduction to Blocks. Blocks Blocks are used to give instructions to your robot. There are many types of blocks You can use the blocks.
CopiBook Manual Follow these steps for correct use of the CopiBook Version: DLC
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
Working “Control any electrical device with your T.V remote(any brand)” wizardelectronics.weebly.com.
Instructional E-Classroom Instructional Guide Seneca College, Audio-Visual Services.
Fundamentals of Digital Images & Photography. Pixels & Colors The pixel (a word invented from "picture element") is the basic unit of programmable color.
The Digital Camera Canon Power Shot ELPH 100 HS.
Zeiss Neon 40 EsB Sample Insertion/Removal
In Photography, there is an Exposure Triangle (Reciprocity Theory) Aperture – size of the iris opening, how much light come into the “window” Shutter Speed.
Slide 1 Welcome to SimELMO; 35MM Slide Edition! In this simulation you will learn to display individual photographic slides via your Elmo document camera.
AUDIO VISUAL TRAINING Bruce Hall-Smart Class. SMART CLASS EQUIPMENT Smart Class LCD Projector/Built In Screen Control Panel Credenza (DVD/VCR & P.C. inside)
In Video, the shutter remains set Shutter Speed – amount of time the camera shutter is open during the exposure of one frame. (Standard – 1/50 sec.
MICROSCOPES: EVERYTHING YOU NEED TO KNOW!. “MICROSCOPE” Micro means tiny, and “ Scope ” means view.
Introduction The Epson LCD projector is a highly versatile presentation tool. The projector can utilize up to two computer sources, and up to three video.
CRESTRON SYSTEMS OPERATION: FOR CLASSROOMS IN COCC’S SCIENCE BUILDING & HEALTH CAREERS CENTER.
Micro-focus Adjustment
In Video, the shutter remains set Shutter Speed – amount of time the camera shutter is open during the exposure of one frame. (Standard – 1/50.
Technology Building-Smart Class
Setting up a trinocular compound microscope for best viewing
By: Hunter J. Jones, LS.573.W3 December 2009
2011/ 07/06 Jacqueline Yan IPBSM
Meeting In A Box Set Up Guide
Laser 3000™ Operating Instructions
Crew Position-Camera Operator
Harvard Medical School Neurobiology Imaging Facility
2. ATP INITIALIZATION PLACE ATP SWITCH TO “1” OR “NORMAL” POSITION A
Harvard Medical School Neurobiology Imaging Facility
Presentation transcript:

A. Imaging sample: 1. Place sample on stage 2. Make sure sample does not interfere with C mirrors 3. Start “Sonic MyDVD” on both laser heating computers. Select “Create or Modify a DVD-Video Project”. Then click “Capture” button. Live video will appear on monitors. 4. Open “Motor Monitor.vi” on ES-2 computer (“Shortcut to BL Control Main:Windows:Motor Monitor.vi”) 5. Use “ES 2 Sample X”, “ES 2 Sample Y” and “ES 2 Sample Z” to position sample in field of view of monitors. Get sample in approximate focus on both cameras. 6. If necessary, use the “PICOMOTOR JOYSTICK” to focus objective lenses (motor C on both drivers 1 &2) 7. Adjust illumination with remote control (hutch lights may need to be turned off for best viewing). B. Turn on laser (see p. 3 for first 3 steps & p.4 thereafter) : 1. Turn on both power switches for each power supply. 2. Turn on pump for cooling water supply (flow switch). 3. Wait until all lights are green and audible alarm silences. 4. Close and lock hutch door. 5. For each remote, press “CTRL” button on laser remote control twice and press “ENTER” button once “REMOTE CONTROL” appears on the display. 6. For each remote, press “LAMP” button on laser remote control twice and press “ENTER” button once “LAMP ON” appears on the display. 7. For each remote, press “LAMP” button on laser remote control 3 times and press “ENTER” button once “CURRENT SETTING” appears on the display. 8. For each remote, enter desired lamp current and press “ENTER” (lasing begins at a lamp current of 9.00 amps). 9. Press “SHTR” button on #1 laser remote control twice and press “ENTER” button once “SHUTTER OPEN” appears on the display.

C. Heating sample with laser: 1. Push red “OPEN” button on REMOTE LASER SAFETY INTERLOCK (you may find it more convenient to use the shutter control on the laser remote control. 2. Use the “PICOMOTOR JOYSTICK” to adjust carbon mirrors to bring both laser spots to the same position (motors A & B on both drivers). Driver 1 is for upstream, driver 2 is for downstream. 3. Use “ES 2 Sample X”, “ES 2 Sample Y” and “ES 2 Sample Z” to move sample under laser beam. 4. If necessary,increase laser lamp current. You may have to set the power level to 20 Amps to get coupling for some samples. 5. When laser glow saturates monitor adjust the neutral density filter wheel (Double click “SGcommander” icon on Spec1, “Next”, “Next”, “Start Test”, “Finish”, “Stage Control”, axes #1&2) D. Turning system off: 1. Push “Close” button on REMOTE LASER SAFETY INTERLOCK 2. Press “SHTR” button on laser remote control twice and press “ENTER” button once “SHUTTER CLOSE” appears on the display. 3. For each remote, turn lamp current to amps and turn lamp off. 4. Quit all software programs. 4. Open hutch. 5. Turn off cooling water flow and both power switches on each laser power supply.

Turning laser on: Do this for both power supplies! 1. Turn on main power for laser 2. Turn on secondary power for laser 3. Turn on cooling water flow Wait till all lights are green (may take a few minutes)

Using the remote control units (there is 1 for each power supply) 1. push the “CTRL” buttons twice so that remote control is activated 2. push the “LAMP” buttons until the display reads “Lamp On”, then press the “ENTER” button 3. push the “LAMP” buttons again until the display reads “Lamp Current”, press the “ENTER” button, then enter the current value desired. Start at a low value (10.00 amps), then ramp up 4. push the “SHTR” buttons until the display reads “Shutter Open”, then press the “ENTER” button. Use Control pad #1 as the master controller

YAG Lens YAG Lens UpstreamDownstream 1C 2C 2B 2A 1B 1A Lower Shelf Optics Movements corresponding to picomotor selection in terms of Driver&Motor note: the tilts of the C mirrors are not orthogonal to each other