Audiomatica ClioWin 7 – Measurement System
Topics General System Overview System Philosophy System Hardware and Accessories Software Layout Measurement Modules Some Application Examples
Clio Measurement System Clio uses a simple audio platform for computer In/Out – PCI Card Calculations are based Computer CPU A signal conditioner is used as a Front-End with the external world Additional accessories may expand functions and possibilities
Clio Measurement System PB-4281 PCI board and SC-01 Signal Conditioner
Clio Measurement System
Clio Accessories CLIOQC Model 4 Amplifier & SwitchBox
The QCBOX
Clio Measurement System: General Application
Clio Measurement System: Clio + QCBOX Amplifier
Clio Measurement System: QCBOX used as a connection panel
Clio Accessories: The Microphones Mic-01 & Mic-02
Clio Accessories 0 or 20 dB of Gain A,B,C Weighting Filters Selectable
ClioWin version 7: Calibration Procedure
Clio Measurement System: Measurement Precision
ClioWin version 7 – Software Layout
ClioWin version 7 – Software Layout: User selectable options
ClioWin version 7 – Software Layout: External Hardware Interface
ClioWin version 7 – Software Layout: Generator dialog boxes
ClioWin version 7 – Generator
ClioWin version 7 – Software Layout: Measurement Notes
ClioWin version 7 – Software Layout: Graphics & Data Export
ClioWin 7: Multiple Document Layout
ClioWin 7: MLS & Log Chirp Module
ClioWin 7: Cumul. Spectral Decay
ClioWin 7: Polar Directivity Map
ClioWin 7: Polar Analysis
ClioWin 7: Acoustical Parameters
ClioWin 7: FFT Spectrum + Time Data
ClioWin 7: RTA Spectrum Analyzer
ClioWin 7: "LIVE" Transfer Function
Sinusoidal Freq. Response + Harmonics
ClioWin 7: Sinusoidal Impedance
ClioWin 7: Multi-Meter Module
ClioWin 7: T&S Parameters Modules
ClioWin 7: Wow & Flutter Analysis
ClioWin 7: Leq Sound Level Analysis
ClioWin 7: Linearity Analysis
ClioWin 7: Distortion Analisys
ClioWin 7: QC Capability
ClioWin 7: A QC Script
QC: Tolerance masks (Limits) relative limits absolute limits [RELATIVE] [UPPER LIMIT DATA] [LOWER LIMIT DATA] [ABSOLUTE] [UPPER LIMIT DATA] [LOWER LIMIT DATA]
QC: Sensitivity & Level check
level shift
QC: Sensitivity & Level check [RELATIVE] [LEVEL] UPPER=3 LOWER=-3 FREQHI=5000 FREQLO=400 [UPPER LIMIT DATA] [LOWER LIMIT DATA]
QC: Sensitivity & Level check [RELATIVE] [SENSITIVITY] FREQ1=500 FREQ2=1000 FREQ3=2000 UPPER=102 LOWER=100 [UPPER LIMIT DATA] [LOWER LIMIT DATA]
QC: T&S parameters check LIMITS [TSPARAMETERS] REDC=6.2 DIAMETER=110 KNOWNMMD= QTSUPPER=0.6 QTSLOWER=0.3 FSUPPER=90 FSLOWER=50 CMSUPPER=1.1 CMSLOWER=0.8 BLUPPER=6.5 BLLOWER=6 ZMINUPPER=7.5 ZMINLOWER=7 SCRIPT [SIN] OUT=-2.0 IN=0.0 REFERENCE=IMPEDANCE.SINI LIMITS=IMPEDANCE.LIM
QC: RUB&BUZZ check LIMITS [UPPER LIMIT DATA] SCRIPT [FFT] OUT=0.0 IN=-10 REFERENCE=R&B.FFT LIMITS=R&B.LIM
QC: THD & Harmonics check LIMITS [UPPER LIMIT DATA] [LOWER LIMIT DATA] [3 UPPER LIMIT DATA] [4 UPPER LIMIT DATA] [THD UPPER LIMIT DATA]
QC: Operator interaction
ClioWin 7: Suggested Hardware & Software Requirements PentiumII Processor or better 1 Free PCI Slot Microsoft Windows 98, ME, 2000 or XP 1024x Colors Video or better