Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level.

Slides:



Advertisements
Similar presentations
CURRENT TRANSFORMERS AND VOLTAGE TRANSFORMERS
Advertisements

Chapter 12 Transformers. Chapter 12 Transformers.
ENERGY CONVERSION ONE (Course 25741)
Power System Analysis/ Power System 1 EEE 4113/ EEE 3131
GE Consumer & Industrial Multilin  Single & Three phase models  Specific mount CT’s  Rectangular & Toroidial models  Plastic case & cast models  Multi.
SUBJECT : DC Machine & Transformer
Electrical Power Systems
Transformer.
How Electricity enters in our houses Electricity supplied to us at our home is 220 volt and A.C.. This main line power and the wires carrying it are called.
Electrical Machine-I EE 2107 Dr. Md. Sherajul Islam
Substations. Substations Chapter 4 Substations Major types of equipment found in most transmission and distribution substations with their purpose,
Transformer with open secondary.
Unit 28 Single-Phase Transformers. Objectives: Discuss the different types of transformers. List transformer symbols and formulas. Discuss polarity markings.
Chapter 2 Transformers.
Engineering Practice Electric Fitting Resistance Electrical resistance is the ratio of voltage drop across a resistor to current flow through the resistor.
1 Introduction to Power Systems Expensive! Influential!Intrusive! Source: Riadh W. Y. Habash, Electromagnetic Fields and Radiation, Marcel Dekker, New.
LO: Understand the uses of electromagnets
Electrical Power Systems
POWER SYSTEM PROTECTION
Instrument Transformers
Electrical Distribution Systems
1 © ABB AB, Application of Unit Protection Schemes for Auto-Transformers Zoran Gajić ABB AB Vasteras, Sweden Authors: Z. Gajić, ABB Sweden.
Connections of a CT and a PT to supply, load and relay.
POWER CIRCUIT & ELECTROMAGNETICS
AUTOMOTIVE CHARGING SYSTEMS CHAPTER 7 PURPOSE OF CHARGING SYSTEM b CONVERT MECHANICAL ENERGY INTO ELECTRICAL ENERGY b RECHARGE BATTERY b PROVIDE POWER.
Bellringer What is one way to increase the strength of the magnetic field of a current?
Modeling of Power Transformers A Static Device. Transformers The transformer enables us to utilize different voltage levels across the system for the.
Alternating and Direct Current Direct Current (DC) is the one way flow of electrical charge from a positive to a negative charge. Batteries produce direct.
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
Transformer Protection Over-current protection in the form of fuses may be the only protection provided to a small 100 kVA, 11 kV/440 V distribution transformer.
Chapter 2 Transformers Edit by Chi-Shan Yu Electric Machinery.
What is POWERGRID??? The Power Grid Corporation of India Limited (POWERGRID), is an Indian state-owned electric utilities company headquartered in Gurgaon,
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
A Presentation On 132 KV GSS BEHROR
Transformers They’re more than meets the eye. A transformer is made of 2 coils, near each other but not touching. Many times one is inside the other,
Electrical Power Distribution Information obtained from howstuffworks.com.
Submitted to: Submitted by:
SEMINAR PRESENTATION ON 220 KV GSS UDAIPUR
ON 400 KV GSS RAISER JAIPUR ROAD ,BIKANER
Department of Electrical Engineering
Current transformers (CTs)
A Training Presentation On 132 KV GSS JAIPUR Submitted in partial fulfillment For the award of the degree of BACHELOR OF TECHNOLOGY Submitted To:- Submitted.
132KV GSS PIPAR CITY JODHPUR
Electrical Engineering
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Submitted To:- Submitted By:- Mr.
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
Protection of Power Systems
 Electromagnetic Induction – The production of an emf (the energy per unit charge supplied by a source of electric current) in a conducting circuit by.
AC Current An AC circuit consists of a combination of circuit elements and an AC generator or source The output of an AC generator is sinusoidal and varies.
Protection of Power Systems
REDA Production Systems
ELECTRICAL INSTRUMENTS ( service and utilization )
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
D.C. Machine & Transformer Topic: Instrument Transformer Electrical:-1 presented by: Jill Chauhan ( ) Chirag Agarawal ( )
1 :. Introduction These are special type of transformers used for the measurement of voltage, current, power and energy. As the name suggests, these transformers.
 The figure below shows a protection system for a transmission line, consisting of a CT, PT, a relay and its associated circuit breaker.
1. 2 Magnetization Current in a Real transformer Although the output of the transformer is open circuit, there will still be current flow in the primary.
ET 332b Ac Motors, Generators and Power Systems 1 Lesson 11_et332b.pptx.
Auto Transformer Current Flow. Principles of Auto Transformers H X H0/X0.
HNC/D Engineering Science
TRANSFORMER A transformer is a static device.
TRANSFORMERS.
Balaji engineering college Special transformer
CHAPTER 6 SPECIAL TRANSFORMERS Electrical Machines.
Special Transformer Current Transformer ( C.T. )
MAGNETISM AND ITS USES Producing Electric Current
Substation Equipment's
Presentation transcript:

Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level as requirement or line design parameter. It is just like transformer but connected to unit of the generating house that's why we called it unit transformers. Transformers used in three-phase systems may consist of a bank of three single-phase transformers or a single three-phase transformer which is wound on a common magnetic core. In Tongi power plant they use three single phase transformer which make a bank and produce three phase supply. Fig: Unit Transformer used in Tongi plant

Cont. Main transformer specifications: Application standard IEC 60076 Rated parameters Type DFZ-55000/132W2 TH (single-phase composite type) transformer) Cooling type ONAN/ONAF (75%/100%) Frequency 50Hz Impedance voltage 16% Rated power 3×550000kVA Rated voltage 132/√3×(1±8×1.25%)/15kV Wiring Ynd1 Insulation level LI650AC275-LI650AC275/LI105AC45 Rated current 721.69/6350.85A

Instrument Transformer

Current Transformer Current transformers are used for reducing/stepping down a.c. current from higher value to lower value for measurement /protection/control.Typical secondary current of CTs are 5A or 1A r.m.s There are two classes of current transformer: Measuring current transformer Protective current transformer Fig: Current Transformer used in Tongi plant

Cont.. Here is difference between the protection CT and metering CT in operating conditions… The CT using for protection will have to carry the fault currents which are 10 times the normal full load current. The CT used for metering will have to carry only full load current

Voltage transformer Voltage transformers are use for measurement and protection. It stepping down the voltage for the purpose of protection, measurement and control. The primary of voltage transformer is connected directly to power circuit between phase and ground depending upon rated voltage and application. Typical secondary voltage of VTs are 110V or 100V. Fig: Voltage transformer used in Tongi plant

The trip circuit When a fault occurs in the protected circuit, the relay (2) connected to the CT an PT actuates and closes its contacts (6). Current flows from the battery (5) in the trip circuit (4). As the trip coil of the circuit breaker(3) is energized, the circuit breaker operating mechanism is actuated and it operates for the opening operation.