UFM610UFM610 Wellcome Bienvenue Willkommen Bienvenido Добро пожаловать ようこそ 歡迎.

Slides:



Advertisements
Similar presentations
Doppler echo & colour doppler -fazil bishara.  Blood is not a uniform liquid blood flow is pulsatile and is a very complex phenomenon!!!  Density provides.
Advertisements

Welcome Bienvenue Willkommen Bienvenido Добро пожаловать ようこそ 歡迎.
Thermo-energy audit Services for thermo-energy audit Flow measurement.
Wind Tunnel Testing of a Generic Telescope Enclosure
Masato Hirota MRI Measurements of Fibre- Suspension Flow in a Sudden Contraction/Expansion FP1005 & SIG43 Workshop NTNU, Trondheim October 2012.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Closed Conduit Measurement Techniques  Pipeline systems  Transmission lines  Pipe.
Introduction to Fluid Power by Mike Pierno. Pascal’s Law, simply stated, says this: Pressure applied on a confined fluid is transmitted undiminished in.
California State University, Chico
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Closed Conduit Measurement Techniques ä Pipeline systems ä pipe networks ä measurements.
NorCal Tech 2005 Technical Conference
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
1 Anayet Karim. 2 Course Evaluation Test 1Test 1 Test 2Test 2 Assignment 1Assignment 1 Assignment 2Assignment 2 Lab ModuleLab Module Final ExamFinal Exam.
Process Variables and Sensors. Parts and materials needed for today (instructor will provide): DP transmitters Thermocouples Filled-bulb temperature sensor.
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
Flow Sensors.
Abstract An upgrade to the ATLAS silicon tracker cooling control system may require a change from C 3 F 8 (octafluoro-propane) to a blend containing 10-30%
CBE 150A – Transport Spring Semester 2014 Flow Measurement and Control.
Installation of Mags What details need to be planned out? Manufacture requirements IDWR requirements Site selection for installation Examples of good and.
Basic Hydraulics Irrigation.
Module 10/11 Stream Surveys Stream Surveys – February 2004 Part 3 – Hydrologic Assessment.
Two Phase Flow Modeling Prepared by: Tan Nguyen Two Phase Flow Modeling – PE 571 Chapter 3: Stratified Flow Modeling For Horizontal and Slightly Inclined.
Rudolf Žitný, Ústav procesní a zpracovatelské techniky ČVUT FS 2010 Flowrate Experimental methods E EXM5 Some pictures and texts were copied from.
Numerical methods in flow metrology Sampo Sillanpää, Centre for metrology and accreditation.
Wellcome Bienvenue Willkommen Bienvenido Добро пожаловать ようこそ 歡迎.
Program ultrasonic range sensor in autonomous mode
Radial T Profile Across Wall Separating Hot & Cold Fluids 1.
Venturi Meter By Alex Turner & Mick Lock. What is it? A pipe that has a cone that narrows and then gradually returns to the original diameter of the pipe.
Resident Categorical Course
Lesson 21 Laminar and Turbulent Flow
MSc and BSc projects for 2005/2006 Supervisor: Rune W. Time These projects are mainly intended for MSc thesis work, but may be simplified to BSc thesis.
Sino-German-Workshop, Oct , Shanghai, China 1 New possibilities for velocity measurements in metallic melts S. Eckert, G. Gerbeth, F. Stefani.
10/20/2015Copyright © 2008 Ballios, Dow, Vogtmann, Zofchak.
Display of Motion & Doppler Ultrasound
Introduction to the Physics Echocardiography Introduction to the Physics Echocardiography Jose L. Rivera, M.D. January 9, 2010.
HYDRAULICS of steady and pulsatile flow in systemic circulation Motivation Experimental techniques for measurement pressure and flowrate How to calculate.
Modeling Acoustic Modes in a Continuous Loop Piping System E. Marderness 1 and E. Gutierrez-Miravete 2 1 General Dynamics-Electric Boat, Groton, CT 2 Department.
Ultrasonic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Hydraulics is defined as the study of fluid behavior, at rest and in motion Properly designed piping with sound hydraulics can: - Greatly reduce maintenance.
CFD Lab 1 Simulation of Turbulent Pipe Flow Seong Mo Yeon, Timur Dogan, and Michael Conger 10/07/2015.
1/22 R. Long 1, P. Cawley 1, J. Russell 1,2 1. UK Research Centre in NDE, Imperial College 2. Rolls-Royce Marine, Derby.
Enrico Da Riva (EN/CV/PJ)
GOVERNMENT ENGINEERING COLLEGE, BHARUCH (014) Chemical Engineering department SEM-iii Sub: fluid flow operation topic: orifice meter & rotAmeter Guid by:
FLUID FOW FOR CHEMICAL ENGINEERING
Electromagnetic Blood Flow Meters Measures instantaneous pulsatile flow of blood Works based on the principle of electromagnetic induction The voltage.
Prepared By: GUNDALE MANSI V.
Product group OPTISONIC Ultrasonic Process flowmeters PM EMF & UFM
Mass Flow Sensor Integration Team 5: Beau Rodgers Luis Mendez Brian Roberts Keenan Cheeks Sponsored by: Danfoss Turbocor Advised by: Dr. Shih.
17 – Measurement of Flows in Piping Systems 2 March 19, 2013 Professor Doran CEE 410.
DXN Ultrasonic Portable Flow Meter
UNDERSTANDING DIFFERENT
Ultrasonic High-Pressure Full-Bore Return Flow Meter IBJ Technology Ingenieurbüro Jäger 1 Ultrasonic Mud Flow Meter.
6.5 Recommended Velocity Of Flow In Pipe And Tubing.
Date of download: 11/12/2016 Copyright © ASME. All rights reserved. From: High Frequency Guided Wave Natural Focusing Pipe Inspection With Frequency and.
PRESENTATION ON MEASUREMENT OF FLUID VELOCITY Submitted by:  Prativa Giri (072bme628)  Sutishna Pokharel(072bme646)
Measuring principles Introduction 1.
BME 312 BIOMEDICAL INSTRUMENTATION II LECTURER: ALİ IŞIN
Consequence Analysis 1.2.
Residential Metering: iPERL vs Ultrasonic meters
Prof. Sajid Naeem (DOES – PC)
SONARtrac® vs Ultrasonic Flowmeters
Energy Loss in Valves Function of valve type and valve position
Principle of the process Design For Manufacturing (DFM)
Date of download: 12/16/2017 Copyright © ASME. All rights reserved.
Date of download: 1/3/2018 Copyright © ASME. All rights reserved.
Prepared by: Hamidreza Karamouz
HYDRAULICS of steady and pulsatile flow in systemic circulation
Ultrasonic Flowmeter Technology
20. Pipe Flow 2 CH EN 374: Fluid Mechanics.
KROHNE Ultrasonic Flowmeters
Presentation transcript:

UFM610UFM610 Wellcome Bienvenue Willkommen Bienvenido Добро пожаловать ようこそ 歡迎

The Transit Time Clamp-on Flow Metering Technique

Introduction Principle of operation. Modes of operation. Installation guidelines.

Principle of operation The general principle of time of flight flow measurement. The phase measurement system. Modes of operation A B Flow Sensor Block Liquid Sensor Block

V f =Flow velocity l=Distance between transducers C f =Path length between transducer faces t=Transit-time downstream Kn=Profile correction factor  =Propagation angle Approximate relationship between fluid velocity and measured time. Does not include clamp on transducer delays. The general principle of time of flight flow measurement.

Typical sound path for a clamp on ultrasonic meter Steel Transducers Plastic Line represents path of sound wave Water Pipe cut through side view

The direct time measurement system  

A B Flow Sensor Block Liquid Sensor Block Pipe wall A Flow Liquid Sensor Block B Pipe wall Reflex mounting ease of setup good results over a broad range of applications Diagonal mounting extends the readable pipe diameter for given sensors better for high flows better with turbulent applications Modes of operation

A B Flow Sensor Block Liquid Sensor Block Pipe wall A B Flow Sensor Block Liquid Sensor Block Pipe wall Double reflex mounting ease of setup useful for smaller pipe diameters good on low flow rates Triple reflex mounting ease of setup useful for smaller pipe diameters good on low flow rates Modes of operation

Installation guidelines Transducer positioning. Flow profiles

Ultrasonic flow meter axial and radial sensor location

Summary Principle of operation. Modes of operation. Installation guidelines.