DCRK DIGITAL POWER FACTOR CONTROLLERS

Slides:



Advertisements
Similar presentations
“Power Factor” In Transmission System
Advertisements

LV Compensation and Filtering Give Oxygen to your electrical network
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
CL100D series DSP controlled Uninterruptible power supplies.
Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.

QUALITY AND TECHNOLOGY
Load Management System
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
 UK Power Networks. All rights reserved Distribution Network Visibility Low Carbon Networks Fund Tier 1 project UK Power Networks & PPA Energy Omer.
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
4 key operations UP/ DOWN 、 Esc and Enter Only 3 keys are needed for the rator to adjust all the parameters Simple Esc key Chips Programmable Intelsteer.
LP33 Series UPS kVA 400Vac/CE
FP5000 Refer to for the latest information on this constantly evolving productwww.eatonelectrical.com.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
MEASUREMENT DEVICES OUTLINE Multimeters Analog Multimeters
Per Unit Representation Load Flow Analysis Power System Stability Power Factor Improvement Ashfaq Hussain.
G GE Power Management MMII Intelligent MCC Controller.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
in the Age of the Photovoltaic
DC POWER SUPPLY. Maeil Power Co.,Ltd is a one of leading supplier of switching power supply. The company design and manufacture quality products that.
EDIA DIVISION Titre de la présentation en Arial, 45 Alpican capacitors F.Dupré 09/11/2012.
G GE Power Management 369 Motor Management Relay.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
The New Adventurer Pro Is Here!. What’s New? Bright alphanumeric dual line display Better weighing cell and weighing performance 7 application modes Better.
1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press.
Looking for a more powerful circuit monitor?
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
FG Wilson Access 4000 Control Panel
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
SFT 2841 IN CONNECTED MODE Prepare setting files.
New IQ300 IQ Data & IQ Generator Replacement. Current Product  IQ Data Measures  Phase Currents  Voltage L-L, L-N  IQ Generator adds  Frequency measurement.
Prepared By :.  Introduction  Techniques Used  Case Study  Advantages  Application  Conclusion OUTLINE.
Scout Pro Training Introducing the Scout Pro Portable Balance: 7 Models From 200g x 0.01g to 6000g x 1g 5 Application Modes Optional USB or RS232 Interface.
December 2002 Endos DC has been designed from scratch. Every component of the system is completely new: –new generator –new tubehead –new arm –new timer.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
PowerLogic® PowerView Software
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
TDSPWR2 Power Measurement and Analysis Software Addressing Today’s Challenges.
3-Phase Submersible Motor Control
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
SmartMQn Motor Horner APG, LLC September 9, 2008.
EPack relaunch. Schneider Electric 2 -Industrial – Eurotherm – 16/12/2015 ●1. Reduce your equipment costs.
Hybrid Power Controller (HPC) Final Presentation Senior Design II.
CUE – Make Any Pump an E-Pump
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Autoflame Training,
“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise.
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
LP Series 400V CE GE Consumer & Industrial September 2004.
NEED FOR ADAPTATION of POWER SYSTEMS & CONTROL SOLUTIONS LED AIRFIELD LIGHTING October 20, 2015 IES ALC 2015.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
LEADING THE PACK.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
TRANSMISSION LINE MULTIPLE FAULT DETECTION AND INDICATION TO EB
DIGITAL MULTIMETER DMG
POWER FACTOR CORRECTION
AUTOMATIC POWER FACTOR CONTROLLERS
VARLOGIC NRC12 Varmetric Controller
APFC-03 Reactive Power Compensation Method & Settings
POWER FACTOR CORRECTION
POWER FACTOR CORRECTION
Portable Working Standard
SCADA for Remote Industrial Plant
Fundamentals of Harmonics
PowerValue 11/31 T Sales Presentation
PowerLogic™ offer for the basic metering market
PM9, PM9P and PM9C Power Meter
Power monitoring software
Presentation transcript:

DCRK DIGITAL POWER FACTOR CONTROLLERS

DCRK DIGITAL POWER FACTOR CONTROLLERS 96X96mm 144X144mm DCRK5 5 steps DCRK7 7 steps DCRK8 8 steps DCRK12 12 steps M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS OPERATING FEATURES MEASUREMENTS Present cosj Present L-L voltage + maximum  Present current + maximum  Dkvar e kvar Weekly average P.F.  and present P.F. Capacitor overload % + maximum  Present panel temperature + maximum .  Measurement logged in non-volatile memory and keypad clearable. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS OPERATING FEATURES BUILT-IN PROTECTIONS Capacitor current overload Capacitor over-voltage Panel over-temperature No-voltage release. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS OPERATING FEATURES SETUP Base setup with most common settings (6 parameters) Advanced setup with special settings (16 parameters) Fast PC setup Fully automatic setup M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS OPERATING FEATURES ALARMS A01 Under-compensation A02 Over-compensation A03 Low current A04 High current A05 Low voltage A06 High voltage A07 Capacitor overload A08 High temperature A09 No voltage release. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS ADVANTAGES Extensive number of measurements (V-A- kvar- ecc.) Capacitor overload protection Measurement of weekly average power factor Built-in temperature sensor TTL/RS-232 serial communication interface Manual or Automatic set-up Programmable alarms Automatic identification of CT current flow Easy CT setting for the final user Measurement of power factor as well as cosj Keypad lock function. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS cULus (UL for USA and Canada) CERTIFICATIONS cULus (UL for USA and Canada) COMPLIANCE IEC61010-1; IEC/EN 61000-6-2; CISPR 11/EN 55011 M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS COMPARISON M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS COMPARISON M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS COMPARISON M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS TRMS = TRUE ROOT MEAN SQUARE DCRK measurements are calculated in TRMS, to give exact values also in presence of harmonic distortion. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS COSj = DISPLACEMENT POWER FACTOR It is in the cosine of the displacement angle between voltage and current. DCRK regulators can read correctly the D.P.F. regardless of the presence of harmonics on current and voltage waveforms. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS The Power Factor (P.F.) or Total Power Factor (TPF) is the ratio between active power (W) and apparent power (VA). In a system without harmonics, the power factor is the same value as COSj. In other conditions, the power factor is less than the COSj. Power factor correction systems can adjust the COSj to the required value and can thereby obtain the best possible power factor. W W P.F. = P.F. = VA VA M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS MEASUREMENT OF WEEKLY AVERAGE POWER FACTOR This reading considers the last 7 days of the DCRK operation. It is calculated in the same way used by energy suppliers, storing active and reactive energy meters in DCRK internal memory. This value is therefore a true efficiency index of the entire reactive power correction system. Wh Varh² + Wh² P.F. = M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS AUTOMATIC IDENTIFICATION OF CT CURRENT FLOW At power up, the DCRK controller automatically recognizes the current flow direction through the Current Transformer (CT). This avoids inverting the CT connections during installation. In cogeneration plants, where it is necessary to operate in 4-quadrant, the CT connection sense must be set manually. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS EXTREME REDUCTION OF STEP SWITICHING A control algorithm provides for the maximum reduction of the number of operations. The adjustment is conducted in a precise manner and not by consecutive attempts. The reduction of the number of operations substantially lowers the capacitor and contactor wear. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS HOMOGENEOUS USE OF EQUAL RATED STEPS Each step is provided with one operation counter and one hour meter, in order to provide an equal usage of capacitors with the same rating. The uniform operation of the steps prolongs the life and efficiency of both the capacitors and contactors. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS AUTOTRIMMING Consents to the ongoing control of the steps power installed. In case of step wear, all the relative power parameters are automatically recalculated. This allows the DCRK unit to work rapidly and efficiently, that is with fewer and quicker operations. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS OVERLOAD PROTECTION OF CAPACITORS 5% 5th HARM U THD = 5% CAP OVRL = 102.5% The capacitor overload can be caused by overvoltage or, more often, by non-linear loads that cause harmonic distortion on the voltage line. The voltage waveform is analysed by special algorithm that calculates the exact percentage of the current flowing in the capacitors. Once the set current overload threshold limit is exceeded, the capacitors are disconnected within a time inversely proportional to the exceeding limit. THD (Total Harmonic Distortion) does not change with harmonic frequency, and therefore it is not an indicator of capacitor overload. 5% 7th HARM U THD = 5% CAP OVRL = 105.5% 5% 11th HARM U THD = 5% CAP OVRL = 114.5% 5% 13th HARM U THD = 5% CAP OVRL = 120% M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS NO VOLTAGE RELEASE This function can prevent damage to the capacitors by disconnecting them from the mains when short power lossess are detected. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS PROTECTION AGAINST OVER-TEMPERATURE The DCRK controllers include an internal temperature sensor, which monitors the temperature variation of the electric panel. This temperature value is displayed and the maximum value is logged. By setting related parameters, a threshold can be set to switch on a relay to operate a ventilation system. It is also possible to set an higher threshold to generate an overtemperature alarm. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS M FOUR-QUADRANT OPERATION When a plant is equipped with a co-generation system, it means there are conditions where energy is imported (consumed) and others where it is exported (generated). In these circumstances, the displacement angle between voltage and current can vary between 0° and 360° (four quadrants) so the DCRK must be programmed accordingly. It is possible to set two independent cosφ setpoints, one for imported and the other for exported energy. When working with cogeneration plants, automatic CT connection feature cannot be used. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS EASY CURRENT TRANSFORMER SETTING The manufacturer of power factor correction panels can set all of the setup parameters of the DCRK except the CT primary, since it depends on the final customer plant. In this case, during the system installation and once the controller is powered up, the display will show a flashing CT indicating that the CT has not been programmed. Just selecting the correct value from the list and storing it with one key will enable the DCRK operation. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS AUTOMATIC SETUP Allows the installation of the DCRK controllers without programming any parameter. Just pushing two keys, the user is able to put the DCRK into operation. 5sec M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS KEYPAD LOCK The activation of this function is made by a combination of keys. Once programmed, the following operations will be locked: Access to parameter setup Changing of COSj setpoint Changing the operating mode (AUT/MAN) MAX values clearing However, all the measurements will be still accessible. 1° MODE 2° 3 x 3° 2 x M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS TECHNICAL SPECIFICATIONS TTL / RS-232 INTERFACE By using the DCRK SW software and the TTL/RS-232 interface, a quick set-up of the controller can be achieved via PC, avoiding in this way, possible parameter setting errors. The DCRK programmed parameters can also be stored on the PC and quickly downloaded into an unlimited number of units, which require the same programming. The customising of alarm properties can be made as well as the automatic panel testing with the control of the power installed and the test report printing too. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS DCRK SW SOFTWARE TTL / RS-232 COMMUNICATION PORT Full system monitoring: - Graphic and numeric measurements display - DCRK status - Virtual front panel For each step: - Function - Status - Reactive power - Operation counter - Hour meter. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS DCRK SW SOFTWARE MONITORING THE CAPACITORS EFFICIENCY Measurement of the actual kVar of each capacitor step. Counter for the number of switching operations of each capacitor step. Time counter for the total connection time of each capacitor step. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS DCRK SW SOFTWARE TTL / RS-232 COMMUNICATION PORT Access to all setup parameters in four languages Save / Load / Print parameters Highlighted user changes Back-to-default button. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS DCRK SW SOFTWARE TTL / RS-232 COMMUNICATION PORT Alarm properties customization - Alarm enable - Alarm relay activation - Step disconnection - Alarm trip delay. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS DCRK SW SOFTWARE TTL / RS-232 COMMUNICATION PORT Automatic testing of electric panel. M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS SPECIAL POWER FACTOR CORRECTION CONTACTORS Kvar (400V) 60 8 12,5 15 20 30 38 BF9K BF20K 45 BF12K BF25K BF40K BF50K BF65K BF80K Contactor 10 40 50 M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS SPECIAL POWER FACTOR CORRECTION CONTACTORS KITS TO ASSEMBLE BF..K CONTACTORS M23 GB 21 07 03

DCRK DIGITAL POWER FACTOR CONTROLLERS Other products for your power factor correction system Switch disconnectors Push buttons and selectors Digital multimeters M23 GB 21 07 03