Chapter 9 Water Supply.

Slides:



Advertisements
Similar presentations
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Advertisements

Fire Apparatus Pump Theory
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Buildings and Structures 2 Fixed Installations Aim To provide students with information to allow them to recognise the types of fixed fire protection.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Water Underground.
Water Terms
CAFS On-Line Orientation
Fire Streams Geronimo Vol. Fire Dept.. Extinguishing Properties of Water G Water extinguishes fires by G Cooling G Remove heat from the fire G Smothering.
Water supply and drafting. Objectives Understand and be able to demonstrate the different hydrant lays and hook ups Explain/demonstrate how to operate.
Pumping Apparatus Driver/Operator
LoneStar Fire Specialties
CVFD Training – Water Supply SFFMA Training Objectives: –
Fire Streams SFFMA Training Objectives: –
FIREFIGHTER I LESSON 15. SPRINKLER SYSTEM DESIGN AND OPERATION Series of sprinklers arranged to automatically distribute enough water to extinguish or.
Characteristics of Water
WATER SUPPLY Copyright© Delmar is a division of Thomson Learning.
Chapter 9 Water Supply.
CE HYDRAULICS ENGINEERING
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
Pumping Apparatus Driver/Operator
Water Supply 1. Water Supply Components
Intermediate SFFMA Objectives: – Hrs received.
Hydronic Mechanical Controls
Module C Sprinkler systems (4-20)
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Water Supply.
HVAC523 Basic Subsystems.
3 Water. 3 Knowledge Objectives Describe the properties of water. Describe the three sources of water. Describe water’s role in extinguishing a fire.
CHAPTER 9 Copyright © 2007 Thomson Delmar Learning 9.1 Water Supply.
FRESHWATER CHAPTER 10 PG Section 1: Water on Earth Pg. 314.
Earth is the only planet with liquid water at its surface.
The Water Cycle The energy from sun drives the water cycle which in turn drives the weather. The energy from sun drives the water cycle which in turn.
FVCC Fire Rescue Water Supply.
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
Unit D – Water Systems. Water is Key to Life without water, there would be no life – humans need 1-2 litres of water daily to keep our organs properly.
Animation 78CB956F92D4BB85256C6B005A62C7/$file/hydrologi c2.swf?openelement
Earth Science Unit Overview: Chapter 4 – Earth’s Water
MODULE 4: WATER SUPPLY AND EXPOSURE PROTECTION. OBJECTIVES Module 4 Overview Identify the principles of water supply and tactics for establishing water.
AKA The Hydrologic Cycle. Water 3 states Solid Liquid Gas The 3 states of water are determined mostly by temperature. Even though water is constantly.
Chapter 2.1. Seventy percent of the earth’s surface is covered with water. There is water literally all around us in the form of water vapor, or water.
Firefighter III Module B Water Supply (4-19) (4-19)
Chapter 11 Water. Properties of water that are important to know for Environmental Science Water is a polar molecule Surface tension Capillary action.
Tanker Operations In Water Supply Michael Crawford July 2002.
Groundwater Basics. Water Cycle What is Groundwater? Groundwater is simply water that exists below the earth's surface. Groundwater is often thought.
The Water Cycle. Water 3 states Solid Liquid Gas The 3 states of water are determined mostly by temperature. Even though water is constantly changing.
The Water Cycle. Continuous process by which water moves through the living and nonliving parts of the environment. Continuous process by which water.
Explain the structure and processes within the hydrosphere. 1.
Earth’s Fresh Water Vocabulary Chapter 8, Lesson 6
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Video: Fire Hydrant Time: 1:01 Chap 14-1
Unit 8 Lesson 2 Human Impact on Water Copyright © Houghton Mifflin Harcourt Publishing Company.
Apparatus Testing Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Water Shuttle Operations
Water Terms
Fire Service Pump Operator - 03 Water.
Unit 4 Lesson 1 Human Impact on Water
Water Cycle.
Unit 4 Lesson 1 Human Impact on Water
7th Grade Weather Unit-Marion
Water Wise Chapter 11, Section 1.
Fuel Supply System Service
Earth’s Fresh Water Vocabulary Chapter 8, Lesson 6
The Water Cycle.
What is the water cycle?.
Earth is the only planet with liquid water at its surface.
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Water Underground.
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

Chapter 9 Water Supply

Introduction Water supply is one of the most critical elements of firefighting Water supply dictates the fire flow capacity Pressure is the force of water Measured over an area Fire flow requirement is the amount of water required for putting out the fire Water’s ability to absorb large quantity of heat makes it effective in fighting fire Water cools the fuel below its ignition temperature

Sources of Water Supply A wide range of natural and man-made factors affects water sources Water in a constant cycle of change Sun evaporates water into atmosphere Condenses into clouds Eventually falls as rain Some areas alternate between rainy and dry seasons Some areas have plenty of water, but it is frozen

Groundwater Most of Earth’s freshwater supply is groundwater Seeps into the ground from rain and other sources Collects in aquifers Permeates into layers of water-bearing soil Water table: level of water under Earth’s surface Springs are groundwater sources that flow to the surface Shallow wells prone to changes in water table Deep wells more predictable Less chance of contamination

Surface Water Almost 75 percent of the Earth covered with water Most found in oceans and seas Man-made surface sources include lakes, ponds, reservoirs, swimming pools, water tanks Tidal changes are rising and falling of surface water levels Due to gravitational effects between Earth and moon May be as much as 40-foot difference between high and low

Mobile Water Supply Apparatus Water tank on fire apparatus supplies the water Small fires and fires in areas without water distribution system Water tender: mobile water supply apparatus Tenders combined with portable water tanks provide large volumes of water to fireground Tenders may have small booster pump of at least 250 gpm Fire pump of at least 750 gpm Transfer pump of at least 250 gpm

Tanks, Ponds, and Cisterns Water tanks may be: Underground Ground level Elevated May have a dry hydrant or other connection, or just a drafting point Ponds may be developed for fire protection Lined or unlined, with or without dry hydrants Cistern: underground tank made from rock or concrete

Water Distribution Systems Components of water distribution system: Method of getting the water Filtration, treatment processes Storage, supply, and distribution Small groundwater systems require a well with pumping station Large well systems: multiple supply, processing, storage units with massive feeder lines Water supplied in three ways: gravity fed, pumped, combination

(A) (B) (C) Figure 9-4 (A) Gravity-fed water distribution system. (B) A direct pump water distribution system. (C) A combination gravity-pumped water distribution system.

Fire Hydrants Fire hydrants allow access to water supply systems Two major hydrant types: Wet and dry barrel hydrants Dry hydrant: pipe system for drafting from static water source

Wet Barrel Water in the barrel up to valves of each outlet Used in areas not subject to freezing Allows each outlet to be controlled by separate valve Additional lines taken off or supplied if outlet available Additional connection does not require flow through other outlets to be stopped Main control valve controls flow to all outlets

Figure 9-7 Typical schematic of wet barrel hydrant.

Dry Barrel Used in areas where freezing temperatures could damage the hydrant Valve at base controls water flow to all outlets Base and valve below ground at water main Entire hydrant shut down to connect additional lines Operation in partially open position undermines the hydrant and ground Imminent damage to roads and buildings

Figure 9-8 Dry barrel hydrant.

Figure 9-9 Typical schematic of dry barrel hydrant.

Dry Hydrant Not really a fire hydrant Connection point for drafting from a static water source such as a pond or stream Pipe system with pumper suction connection at one end and strainer at other Primarily used in rural areas with no water distribution system May be found in urban or suburban areas as backup water supply

Figure 9-11 Schematic of dry hydrant installation.

Specialty Hydrants Wall hydrants mounted on wall of a building Be sure to connect to wall hydrant and not the fire pump test connection outlet Direct connection to water supply system Flush-type hydrant mounted below grade level Found in a pit, vault, or valve box Allows access to water source where above-grade hydrant interferes with operations High-pressure hydrants connected to separate high-pressure water system

Figure 9-12 Wall fire hydrant.

Hydrant Protective Devices Devices or valves designed to protect the water system Most hydrants connected directly to domestic water supply Many water suppliers added measures to protect water supply Interior valves, exterior protective devices Exterior systems require lock and key Mostly found on privately owned property

Figure 9-13 External hydrant protective device.

Valves Associated with Water Distribution Systems Gate valves (butterfly valves) opened and closed to control water flow Nonindicating gate valves installed at: Interconnections of water mains Intermediate points of long sections of water mains Before each hydrant and major building connection Check valves control water flow in one direction Backflow preventers: check valves that prevent backflow of water from one system into another

Figure 9-14 Hydrant with plumbing Figure 9-14 Hydrant with plumbing. Note the location of a gate valve between the water main and hydrant.

Rural Water Supply Rural water supply can occur anywhere Urban and suburban areas often have places where hydrants are too far away Limited access highways, large bridges Require careful coordination and control Water supply group supervisor part of incident command system Full authority over water apparatus operations Firefighters assigned to water supply are vital

Portable Water Tanks Mobile water supply apparatuses must quickly offload water and return to fill site Each mobile apparatus should have a portable water tank Capacity equal or greater than its tank size Collapsible or inflatable tanks set up next to engine Jet dump speeds unloading of tanks Multiple tanks using a jet siphon set up together

Figure 9-15 Portable water tanks are an essential piece of equipment for shuttle operations. Figure 9-17 Tender at dump site dropping water directly into portable tank.

Mobile Water Apparatus Operation Shuttle operation involves moving water between dump site and fill site Dump site: where water delivered for quick unloading Set up first Fill site: location of water source Optimum fill site allows vehicles to drive through Shuttle operations time cannot be decreased by increased vehicle speed

Pressure Associated with Water Distribution Systems All Earth’s water under pressure Atmospheric pressure: 14.7 pounds per square inch Atmospheric pressure reduces 0.5 psi per 1,000 feet of elevation Pressure in nonflowing closed system equal at all points While flowing, reduced by friction and loss of pressure at opening

Pressure Associated with Water Distribution Systems (cont’d.) Distribution systems supplied under pressure System pressure never as high as firefighters prefer Pressures below recommended low residual pressure create a vacuum in part of the supply High-flow and/or high-pressure areas are an advantage Low-flow and/or low-pressure areas should be avoided

Figure 9-21 Atmospheric pressure being exerted on container of water.

Figure 9-22 Pressure is expressed in pounds per unit area (psi).

Testing Operability and Flow of Hydrants Regular testing identifies inadequate hydrants Coordinated between fire and water departments Operability testing: Wet and dry hydrants: Visual inspection for damage Ensuring hydrant valve closed Remove all caps, check threads and gaskets Check that all valves allow water to flow

Testing Operability and Flow of Hydrants (cont’d.) Operability testing (cont’d.): Dry barrel hydrant: Ensure drain valve working Determine water level dropping after hydrant shut off Visual inspection of piping, caps, gaskets Flow test followed by backflushing of the hydrant Replace caps, oil moving parts, and paint the hydrant Fireground method for flow tests

Determining Static, Residual, and Flow Pressures Connect a pumper to a hydrant and turn it on Static pressure: pressure in the system with no hydrants or water flowing Charge the first line with desired volume Check compound gauge for residual pressure Compare percentage of pressure drop from static to residual Second test involves multiple hydrants Not conducted during fire operations

Table 9-1 Percentage Drop Measurements

Obstructions and Damage to Fire Hydrants and Mains Obstructions and damage can occur to fire hydrants and water mains Small leaks develop as water system matures Vandals damage by opening or closing valves Opening valve in freezing weather without allowing water to flow may cause hydrant to freeze and crack Accidents can crack pipes or break off a hydrant Firefighters should ensure hydrant is opened or closed fully

Lessons Learned Water is the most common fire extinguishing agent Must be supplied in sufficient quantity Supplying water requires understanding of the water source and the valves and hydrants In areas with no distribution system, create one Difficult to sustain adequate fire flow with mobile apparatus