1 Overview of Standards for External Defibrillators: Role of FDA Charles Ho, Ph.D. FDA/CDRH/ODE

Slides:



Advertisements
Similar presentations
Testing Medical Devices A Brief Overview © 2005 Max Cortner. Copying and distribution of this document is permitted in any medium, provided this notice.
Advertisements

A Review of Codevelopment and Companion Dx Policy Elizabeth Mansfield, PhD Director, Personalized Medicine Staff OIR/CDRH/FDA NCCS Cancer Policy Roundtable.
Participation Requirements for a Guideline Panel Co-Chair.
Mammography Industry: Review of Proposed Accessibility Standards U.S. Access Board May 8, 2012 Atlanta, Georgia.
1 Accredited Standards Committee C63 ® - EMC Subcommittee 8 Bob DeLisi / Stephen Berger Chair / Vice-Chair
Safety and Extrapolation Steven Hirschfeld, MD PhD Office of Cellular, Tissue and Gene Therapy Center for Biologics Evaluation and Research FDA.
EQUIPMENT VALIDATION.
Automated External Defibrillation
Public Health Issues Related to Mutually Conforming Labeling: CDRH Perspective Miriam C. Provost, Ph.D. Office of Device Evaluation Center for Devices.
Facility Design Tutorial This tutorial is designed to enhance knowledge of biotechnological/pharmaceutical processes. The topics covered within this tutorial.
Technology Services – National Institute of Standards and Technology The U.S. Conformity Assessment System and the Role of NIST Ileana M. Martinez National.
1 Certification Chapter 14, Storey. 2 Topics  What is certification?  Various forms of certification  The process of system certification (the planning.
Clinical Engineering The Royal Liverpool and Broadgreen University Hospitals NHS Trust NHS LIVERPOOL SHORT COURSES IN ELECTRICAL SAFETY ISO 9001: 2000.
CUMC IRB Investigator Meeting November 9, 2004 Research Use of Stored Data and Tissues.
ISO 9001 Interpretation : Exclusions
1 Accredited Standards Committee C63 ® - EMC Subcommittee 8 Bob DeLisi Chair 2015 May 07.
Radiological Devices Advisory Committee Meeting November 18, 2009 John A. DeLucia iCAD, Inc.
Adverse Event Reports on Automatic External Defibrillators from Oscar H Tovar MD and Beverly Gallauresi RN, MPH Food and Drug Administration.
Codex Guidelines for the Application of HACCP
TCCA Aircraft Certification
GSC: Standardization Advancing Global Communications Resolution GSC-10/05: (GRSC) Facilitating Liaison in Relation to Measurement Methodologies for Assessing.
Physiological Effects of Electricity on Human Body by Mohd Yusof Baharuddin.
1 Next Generation ISO Susan LK Briggs Presented to EFCOG/DOE EMS Implementation, Lessons Learned & Best Practices Training Workshop, 3/05.
UN ECE Sectoral Initiative on Equipment for Explosive Atmospheres 7 September 2011 United States Department of Labor Mine Safety and Health Administration.
CA 101 Certification and Registration ANSI Annual Conference 2002 by: Gordon Gillerman Manager Governmental Services Underwriters Laboratories
Nonclinical Studies Subcommittee Advisory Committee for Pharmaceutical Science CMC Issues for Screening INDs Eric B. Sheinin, Ph.D. Acting Deputy Director.
Facility Smart Grid Information Model
BUSINESS SENSITIVE 1 Copyright © 2009 by James E. Dvorsky, Battelle Medical Device Solutions Compliance Engineering Jim Dvorsky Battelle Medical Device.
Ways for Improvement of Validity of Qualifications PHARE TVET RO2006/ Training and Advice for Further Development of the TVET.
Product Development Chapter 6. Definitions needed: Verification: The process of evaluating compliance to regulations, standards, or specifications.
University of Miami Office of Research Compliance Assessment Lynn E. Smith, JD, CIM, CIP Johanna Stamates, RN, BA, CCRC With assistance from Elizabeth.
1 CONSENSUS STANDARDS OIVD WORKSHOP April 22-23, 2003 Rockville MD Ginette Y. Michaud, M.D. OIVD.
FDA Recommendations: Sampling Plans for Blood Establishments Lore Fields MT(ASCP)SBB Consumer Safety Officer OBRR/CBER/FDA October 19, 2012.
Product Documentation Chapter 5. Required Medical Device Documentation  Business proposal  Product specification  Design specification  Software.
New Draft Guidance for Multiplex Tests Elizabeth Mansfield and Michele Schoonmaker Office of In Vitro Diagnostic Device Evaluation and Safety (OIVD) CDRH/FDA.
April 8, 2011Page 1 April 8, 2011 The University of Texas Interdisciplinary Energy Conference Overcoming Barriers to Smart Grid & New Energy Services Panel.
21 March 2007 Controls 1 Hardware, Design and Standards Issues for ILC Controls Bob Downing.
QSR and GLP What exactly are these?.
Signamax™ Cabling System Design Principles & Installation Practices Revision A.
Examining Claims for Compliance with 35 U.S.C. 112(a): Part II – Enablement Focus on Electrical/Mechanical and Computer/Software-related Claims August.
History of Pediatric Labeling
COMPARABILITY PROTOCOLUPDATE ADVISORY COMMITTEE FOR PHARMACEUTICAL SCIENCE Manufacturing Subcommittee July 20-21, 2004 Stephen Moore, Ph.D. Chemistry Team.
Integrating a Federated Healthcare Data Query Platform With Electronic IRB Information Systems Shan He IPHIE 2010.
Update on Transfusion Safety Management Systems Blood Products Advisory Committee Meeting, March 9, 2006 Linda Weir, CSO, CBER/OBRR/DBA.
CFC Essential Use Status of Albuterol: Medical Considerations Pulmonary-Allergy Drugs Advisory Committee Meeting June 10, 2004 Eugene J. Sullivan, MD,
Signamax™ Cabling System Review Revision E. INTRODUCTION.
Utah Life Science Summit Nov Phil Triolo, PhD RAC President, Phil Triolo and Associates LC.
ENV 5613 Instructor: Dr. Berrin Tansel Presented by: Puneet Gill & Waseem Haider.
June 23, 2005Abiomed, H DRAFT. CIRCULATORY SUPPORT DEVICES PANEL Thursday, June 23, 2005 Abiomed, Inc. Abiocor® Implantable Replacement Heart HDE.
1 Accredited Standards Committee C63 ® - EMC Subcommittee 8 Bob DeLisi Chair 2015 November 11.
Acceptance test of medical devices The good test report November 2013 Bjarne Månsson.
The CDRH Software Message (October 19, 2002) John F Murray Jr.. Center for Devices & Radiological Health US Food and Drug Administration
의료용 S/W 기술문서 심사 방법 원 찬 요 유엘 코리아 발표자 소개 년 2 월 한양대 전자공 졸업 ~ : ㈜ 금성사 ( 현 LG 전자 ) 연구원 ~ : ㈜ 메디슨 규격팀 팀장
Quality Management Systems Advice from ISO/TC 176 for Sector-specific applications.
Transfer of Standards To Inactive Status John Lemon.
EXCEPTION FROM INFORMED CONSENT IN CPR DEVICE TRIALS: PROTECTION OF PATIENTS’ RIGHTS Circulatory System Devices Panel Meeting September 21, 2004 Elisa.
Auditing ISO Nancy Pasquan November Introductions I am….. You are….. And we are here to discuss: Auditing ISO Quality Systems for Medical.
GRRF Ad-Hoc Working Group
IEEE NPEC SC2 Equipment Qualification Electromagnetic Compatibility Compliance Type Test-Design Considerations- Installation and Mitigation Standard/Guidance.
FDA's Two New Draft Guidance on Software and Device
Premarket Notification 510(k) process
FDA’s IDE Decisions and Communications
Carry Over From API SC6 Winter Meeting API Standard 6A718 Inclusion of Additional Alloy 718 Strength Classes Tim Haeberle 30 June 2011.
with Audrey Turley, B.S., RM (NRCM), CBA (ASQ)
Medical Device Design and Development
Reducing Service Debt via Accessible Procurement
GSC: Standardization Advancing Global Communications
GSC: Standardization Advancing Global Communications
GSC: Standardization Advancing Global Communications
Automated External Defibrillation
Presentation transcript:

1 Overview of Standards for External Defibrillators: Role of FDA Charles Ho, Ph.D. FDA/CDRH/ODE

2 Outline 1.Why use standards? 2.FDA’s role in standards 3.List of major standards 4.Limitations of standards

3 1. Why use standards? Standards facilitate communications in pre-market reviews. Standards provide test protocols with pass/fail criteria, which form a common language between manufacturers and FDA for substantiating claims.No need to re-invent the wheel each time. Standards provide test protocols with pass/fail criteria, which form a common language between manufacturers and FDA for substantiating claims. No need to re-invent the wheel each time.

4 Example: To claim adequate battery capacity to power a defibrillator Reference: ANSI/AAMI DF80, clause Protocol: At O°C, the battery should enable the defibrillator to deliver at least 20 shocks at the maximum shock energy. O°C test is more demanding than room temperature test.] [O°C test is more demanding than room temperature test.]

5 Standards also facilitate standardization of device specifications among device manufacturers. May lead to standardizing certain features, like pad connections and the user interface. But need to be in sufficient detail to allow interpretation by both design engineers and FDA.

6 Remember, most standards concerning external defibrillators are voluntary. The only mandatory standard for an external defibrillator is the Performance Standard for Electrode Lead Wires and Patient Cables, 21 CFR 898.

7 2. FDA’s Role in Standards Although FDA had been involved in the development and use of medical device standards for decades, the Food and Drug Administration Modernization Act (FDAMA) of 1997 formalized the process. * Above statement adapted from FDA website.

8 FDA liaisons attend standard committee meetings, participate in discussions and vote on proposed standards, in order that the resultant standards may be more acceptable to both the industry and the FDA.

9 Dr. Oscar Tovar is our Primary Liaison for standards on external defibrillators at the AAMI DF Committee and the IEC TC 62/SC 62D/MT 19 Committee. Dr. Richard Gray is the Alternate Liaison.

10 The FDA has only one vote in each standards committee, just like any other entity. Thus, some standards may not be 100% acceptable to FDA.

11 In that case, FDA recognizes only the parts of a standard that FDA agrees with, and declines to recognize the parts that FDA does not agree with.

12 Recognition of a standard By recognizing a standard, or parts of a standard, FDA indicates that we have reviewed the standard and found it mostly acceptable for substantiating claims made in a premarket submittal.

13 Example: A 510(k) claiming adequate battery capacity provides a test report using AAMI DF80, clause And FDA can review this test very quickly.

14 If a manufacturer chooses not to comply with an FDA recognized standard, or tests a defibrillator using clauses in the standard that FDA declines to recognize, FDA will still review the premarket submittal on a case by case basis.

15 Consequently, FDA will have to review the unrecognized clauses in a recognized standard, or the unfamiliar test protocols in a unrecognized standard from the ground up. This may generate a lot of basic questions to clarify terms or rationale for a certain test protocol, usually resulting in more work for both the manufacturer and FDA.

16 3. List of Major Standards for External Defibrillators (non-exhaustive list)

17 Hardware  ANSI/AAMI DF80: Medical electrical equipment - Part 2-4: Particular requirements for the safety of cardiac defibrillators (including automated external defibrillators) -- the most commonly used standard in submittals on external defibrillators -- covers most hardware safety and effectiveness specifications, except waveform effectiveness IEC counterpart:  IEC : Medical electrical equipment - Part 2-4: Particular requirements for the safety of cardiac defibrillators and cardiac defibrillator- monitors

18 For general safety:  IEC : Medical Electrical Equipment - Part 1: General Requirements For Safety 1: Collateral Standard: Safety Requirements for Medical Electrical Systems For electromagnetic compatibility (EMC):  IEC : Medical Electrical Equipment - PART 1: General Requirements For Safety 2. Collateral Standard: Electromagnetic Compatibility - Requirements and Tests

19 Biocompatibility [for defibrillator electrodes (pads or paddles):]  ISO – 5: Biological evaluation of medical devices -- Part 5: Tests for in vitro cytotoxicity  ISO Biological evaluation of medical devices — Part 10: Tests for irritation and delayed-type hypersensitivity (sensitization)

20 Environmental testing:  IEC : Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock  IEC : Environmental testing - Part 2: Tests - Test Fc: Vibration (sinusoidal)  IEC Degrees of protection provided by enclosures (IP Code). [protection against rain and dust] For sample list of standards, see handout.

21 4. Limitations of standards Standards do not cover every aspect of the external defibrillator. For example, there is no clinical or animal study protocol in the AAMI DF80 standard. (However, an informative annex DD in DF80 has some historical notes on clinical studies.)

22 Further, it is widely accepted that biphasic waveforms are superior to monophasic waveforms and result in improved patient survival. But the standard that covers basic safety and effectiveness requirements, AAMI DF80, does not prohibit monophasic waveforms. A new defibrillator with this old technology can still claim compliance with DF80.

23 Lastly, some standards permit a large leeway in designing the defibrillator, so that performance could vary considerably from manufacturer to manufacturer. An example is the difference between delivered energy and selected energy in a defibrillator.

24 [From DF80, clause ] Delivered energy = shock energy actually delivered to a patient [From clause ] Selected energy = energy intended to be delivered, as determined by the setting of a control determined by the setting of a control Usually, this is the energy shown in the energy dial of the defibrillator front panel.

25 However, the selected energy is specified for the 50 ohm load only. For all other loads, the manufacturer just has to specify the selected energies in the device manual. Additionally, the verification test protocol allows a ± 15% tolerance in testing the measured delivered energy against the specified selected energy. [clauses 6.3 aa, aa and 50.2]

26 These two layers of tolerance combine to allow delivered energy values that may be very different from the selected energies on the energy dial, for loads other than 50 ohm. Yet not every patient is a 50 ohm load to the defibrillator. Still compliant with DF80!

27 Conclusion This presentation has briefly described FDA’s use of standards for external defibrillators, and the standards’ limitations. It is hoped that everyone can keep these in mind as we move forward in this field.