MaxSG - Low Voltage Switchgear

Slides:



Advertisements
Similar presentations
Seminar on Circuit Breaker
Advertisements

Trystar Generator Docking Stations & Portable Power Cable
Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
Emergency Transfer Controls
We thought it was a GOOD IDEA, so we did it! We were the first to have quick make-quick break operators on bolted pressure contact switches.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
CHREID 2008 ELECTRICAL SAFETY Introduction and Overview of Safety Clayton H. Reid September, 2010.
ACADs (08-006) Covered Keywords Switchgear, motor control, ground, circuit breaker. Description Supporting Material
MAIN ELECTRICAL SURVEY ITEMS, GENERATORS AND GOVERNORS,, CIRCUIT BREAKERS, SWITCHBOARDS AND FITTINGS (Adapted from:D.T. Hall:Practical Marine Electrical.
Switching Device Product Line General Duty and Heavy Duty Safety Switches.
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
VHA PANEL WITH HPA12 CIRCUIT BREAKER
Flanders Electric – Engineering Division Welcomes Youto an Overview of Reconditioned Switchgear.
GE Consumer & Industrial Multilin  Single & Three phase models  Specific mount CT’s  Rectangular & Toroidial models  Plastic case & cast models  Multi.
The Association of Electrical and Medical Imaging Equipment Manufacturers Understanding GFCIs Developed by the NEMA 5PP Personnel Protection Technical.
Breaker Basics Welcome to this general overview of ABB.
Multi-function apparatus for secondary distribution
The Vanjen Group • Manufacture's Representative – Power Generation/Oil & Gas • Covering TX, OK, LA, AK, in some cases NM and MS • Extensive.
Manufacture's Representative – Power Generation/Oil & Gas Covering TX, OK, LA, AK, in some cases NM and MS Extensive Power Gen Experience Extensive Docking.
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
Chapter 7 SYSTEM PROTECTION
Motor Control Center MNS iS with Condition Monitoring
MNS Sprint - A Market Driven Solution
All rights reserved MV SWITCHGEAR.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. CENTERLINE 2100 Motor Control Center - SecureConnect™ September 1, 2011.
1 Air Conditioning Breaker Panels and Disconnects.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ SMC™ Flex Controller kV.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
PowerIT Air Insulated Cubicle Uniswitch
Low Voltage Systems MaxSB - Low Voltage Switchboard
Consumer’s Main Switchroom & Main L.V. Switchboard
SmartMQn Motor Horner APG, LLC September 9, 2008.
Utility Engineers, PC.  Generation  Transmission  Distribution.
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
Submitted to: Submitted by:
SERVICE ENTRANCE EQUIPMENT
Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.
Shore Power System General Location. Shore Power Power comes on to the vessel in the form of 480 Volt, Three Phase, 60 Hz Alternating Current (A/C) electricity.
Main contacts closed – RED Colour with ON
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Fermilab AD E/E Support Department Fermilab’s Experience in Applying OSHA and NFPA 70E Requirements in Accelerator Power Supply Systems NFPA 70E Standard.
Switches and Over Current Protective Devices Class Instructor ALPHER E. DE VERA, uap.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
EE 2353 HIGH VOLTAGE ENGINEERING Faculty Name :A.JAIBUNISHA Faculty Code : EE 58 Designation : LECTURER Department : EEE.
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
SPD II 1 for LV Power (AC/DC)
Shipboard Electrical Distribution
How SCADA Systems Work?.
Electrical Equipment CSP uses conventional electrical equipment in the majority of areas All installations follow the mandatory electrical codes The.
Overview of PowerCube Units and ANSI frames
Personal Protective Equipment
Overcurrent Protection— Fuses and Circuit Breakers
EET 323 – Electrical System Design Lecture 9: Grounding
EET 323 – Electrical System Design Lecture 11: Panel-boards and Switch-boards Instructor: Radian Belu, PhD.
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
HIGH VOLTAGE ENGINEERING Presented By P.Sindhu Asst.Prof EEE Dept
Its strengths, your benefits
Substation Equipment's
Presentation transcript:

MaxSG - Low Voltage Switchgear June 2009 MaxSG - Low Voltage Switchgear © BU 3101 Low Voltage Systems April 19, 2017 | Slide 1

MaxSG Product Overview Features and Benefits Construction Instrumentation Applications Summary © BU 3101 Low Voltage Systems April 19, 2017 | Slide 2

Low Voltage Systems Scenario ABB MV Disconnect Power Transformer O I off Switchboard Switchgear O I OR OR Both Panelboard O I off O I off LVNQ MCC CCP Data Centers © BU 3101 Low Voltage Systems April 19, 2017 | Slide 3

MaxSG Product Overview Features and Benefits Construction Instrumentation Applications Summary © BU 3101 Low Voltage Systems April 19, 2017 | Slide 4

Product Overview Definition Switchgear – A switching/interrupting device used in combination with generation, transmission, distribution, and conversion of electrical power for controlling, metering protecting and regulating devices. Where can they be found? – Substations (downstream from medium voltage electrical equipment and transformer) and inside electrical equipment rooms such as in hospitals, power plants, and oil and gas refineries. © BU 3101 Low Voltage Systems April 19, 2017 | Slide 5

Product Overview Rated Main bus current 2000, 3200, and 4000A Description Value Rated Main bus current 2000, 3200, and 4000A Rated Vertical bus 2000A Rated tested maximum voltage 254Vac, 508Vac, 635Vac Rated voltage 240Vac, 480Vac, 600Vac Phases 3 phase 3 wire, 3 phase 4 wire Neutral 100% rated Frequency 50/60 Hz Short circuit current 65 kA, 100 kA Max peak short circuit current 149.5 kA, 230 kA Enclosure NEMA 1 (with Gasket doors), and N3R Walk In © BU 3101 Low Voltage Systems April 19, 2017 | Slide 6

Product Overview Standards SWITCHGEAR ANSI C37.20.1 -Metal Enclosed LV Power Circuit Breaker Switchgear ANSI C37.51 -Testing of Metal Enclosed LV AC Power Circuit Breaker Switchgear UL 1558 -Switchgear Assemblies CSA -Canadian Standard Assemblies IBC-2006 - Seismic Qualification & CBC-2007 CIRCUIT BREAKER ANSI C37.13 – LV AC Power Circuit Breakers Used in Equipment ANSI C37.16 – Preferred Rating, Related Requirement, Application Recommendations For LV Power Circuit Breakers and AC Power Circuit Protectors ANSI C37.50 – Testing of Low Voltage AC Power Circuit Breakers UL 1066 – Low Voltage Power Circuit Breakers © BU 3101 Low Voltage Systems April 19, 2017 | Slide 7

MaxSG Product Overview Features and Benefits Construction Instrumentation Applications Summary © BU 3101 Low Voltage Systems April 19, 2017 | Slide 8

Key Features and Benefits Emax Power Circuit Breakers – Best of the Breed Trademark, size of CB Trip unit PB for manual opening PB for manual closing Lever to manually charge closing spring Label with electrical characteristics Mechanical device to signal CB open “O” and Closed “I” Signal for springs charged or discharged Mechanical indication of trip Key lock in open position Key lock and padlock in racking-in, racking-out position 12. Racking-in, racking-out device Terminal box Sliding contacts CB position indicator © BU 3101 Low Voltage Systems April 19, 2017 | Slide 9

Key Features and Benefits Three Trip Units PR121 Protection Features Only PR122 Protection Features LCD Display Current Measurement Contact Wear Communications option PR123 PR122 Features Harmonic Measurements © BU 3101 Low Voltage Systems April 19, 2017 | Slide 10

Key Features and Benefits Safety Features Safety shutters (standard) © BU 3101 Low Voltage Systems April 19, 2017 | Slide 11

Key Features and Benefits Safety Features Breaker compartment keyed cells © BU 3101 Low Voltage Systems April 19, 2017 | Slide 12

Key Features and Benefits Safety Features Padlocking provisions Anti-insertion lock Disconnect, connect, and test position © BU 3101 Low Voltage Systems April 19, 2017 | Slide 13

Key Features and Benefits Maintenance Switch Option Provides option to dial down to a lower instantaneous setting on trip unit for performing instantaneous REA Relay Arc Flash System Detects an arc anywhere in the bus compartment and cable compartment utilizing long-fiber sensor system, tripping upstream main breaker in order to provide minimal damage to equipment © BU 3101 Low Voltage Systems April 19, 2017 | Slide 14

MaxSG Product Overview Features and Benefits Construction Instrumentation Applications Summary © BU 3101 Low Voltage Systems April 19, 2017 | Slide 15

Construction Front doors, rear doors, left and right side panels, rear panels (Carbon) 14 GA Internal Sheet Metal (Galvanized) (Instrument compartment, breaker compartment, protection panel, truck rail, overhead lift device, riser support) 11 GA Shipping Frame (Galvanized) 12 GA © BU 3101 Low Voltage Systems April 19, 2017 | Slide 16

Construction Available Widths E2/E3 800 – 2000 E4 3200 Amp E2/E3 800 – 2000 E2 800 - 1600A E6 4000 Amp (65 & 100 kA) (65 & 100 kA) (65 kA) Available Widths 39.4” 31.5” 23.6” 19.7” © BU 3101 Low Voltage Systems April 19, 2017 | Slide 17

Construction Depth Standard – 68.9” Optional 59.1” Height 104.2” Depth Standard – 68.9” Optional 59.1” 91.7” Height 91.7” without overhead lifting device 104.2” with overhead lift device 68.9” 59.1” © BU 3101 Low Voltage Systems April 19, 2017 | Slide 18

Construction Doors: Front doors - Semi-concealed hinges Rear doors – Bolted, optional hinge, Pad-locking handles available Infrared Windows (Optional) Paint ANSI 61 Electro static powder coat (standard) ANSI 70 (Optional) © BU 3101 Low Voltage Systems April 19, 2017 | Slide 19

Construction Rear cable area Mechanical Lugs (standard) Compression Lugs (optional) Main Bus Barriers separating bus compartment from cable compartment (Standard) Vertical Steel Barriers between sections in cable compartments (Optional) © BU 3101 Low Voltage Systems April 19, 2017 | Slide 20

Construction Bus Design Standard temperature rise Max 65ºC over 40ºC ambient Main bus amperages include: 2000A, 3200A, and 4000A with bus bracing at 65kA or 100kA. Vertical bus riser amperages include: 2000A for feeder sections and up to 5000A for Tie sections with bus bracing at 65kA or 100kA. Non-insulated silver plating bussing is standard; optional tin-plating is available. Optional insulated bussing consist of: thermal-contractile flame resistant non-hydroscopic tubing and boots on main horizontal and cable compartment runback bussing. © BU 3101 Low Voltage Systems April 19, 2017 | Slide 21

Construction Control Wiring Inter-cubical wiring made easy Terminal strips Located in wire way on top of enclosure © BU 3101 Low Voltage Systems April 19, 2017 | Slide 22

Construction Front door grounding Inter-cubicle wiring made easy © BU 3101 Low Voltage Systems April 19, 2017 | Slide 23

MaxSG Product Overview Features and Benefits Construction Instrumentation Applications Summary © BU 3101 Low Voltage Systems April 19, 2017 | Slide 24

Instrumentation Breaker door mounted lights, meters and control ABB Indicating Lights Volt, amp, and watt meters Electroswitch Series 20 and 24 control switch Multifunction Metering Electro Industries Others Relays ABB (provided standard when required) GE Multilin (Optional) Basler, Schweitzer, Others (Optional) Surge Protectors ABB TVSS (Standard) Others (Optional) © BU 3101 Low Voltage Systems April 19, 2017 | Slide 25

Instrumentation High Resistance Ground System Post Glover (Standard) Others I-Gard © BU 3101 Low Voltage Systems April 19, 2017 | Slide 26

Instrumentation Software SD-View 2000, PC-based software system enables communication Send opening/closing commands to circuit-breakers Read electrical installation values (current, voltage, power factor, etc.) Read and modify trip characteristics of protection units Log of history of installation Status of apparatus Abnormal operating situation Current, voltage, power measurements in real time © BU 3101 Low Voltage Systems April 19, 2017 | Slide 27

Instrumentation Software SD-Pocket Application designed to connect new protection releases to a PDA or PC Enables use of wireless communication to: Configure protection threshold function Monitor measurement functions Verify status of the circuit-breaker SD-Pocket application scenarios include: During start-up of switchgear, with rapid and error-free transfer of the protection parameters to the releases (also using the dedicated exchange file directly from Docwin); During normal installation service, gathering information on the circuit-breaker and load conditions (last trip information, runtime currents, and other information) © BU 3101 Low Voltage Systems April 19, 2017 | Slide 28

Instrumentation Testing and Calibration PR010/T Portable Test Unit ABB FT-1 Test Switch © BU 3101 Low Voltage Systems April 19, 2017 | Slide 29

MaxSG Product Overview Features and Benefits Construction Instrumentation Applications Summary © BU 3101 Low Voltage Systems April 19, 2017 | Slide 30

Applications MaxSG Market Segments Oil and Gas Mining and Metals Utility and co-generation Steel Mill Pharmaceutical Waste Water Semiconductor Manufacturing Power Generation Food and Beverage Aerospace Critical Power and Data Centers Health Care Critical power Oil and gas Industrial facilities © BU 3101 Low Voltage Systems April 19, 2017 | Slide 31 Utilities

Applications Main-Tie-Main transfer schemes (open and close) Relay controlled PLC Kirk Key Interlock Customized © BU 3101 Low Voltage Systems April 19, 2017 | Slide 32

Applications Communications DCS monitored Modbus (Standard) Profibus DeviceNet Ethernet SD-View 2000 © BU 3101 Low Voltage Systems April 19, 2017 | Slide 33

MaxSG Product Overview Features and Benefits Construction Instrumentation Applications Summary © BU 3101 Low Voltage Systems April 19, 2017 | Slide 34

ABB Competitive Aspects ABB MAXSG is designed, tested, and built per ANSI and UL1558 switchgear standards Key features include: Stability and strong structure Emax breaker Trip Units PR121P, PR122P, and PR123P Safety Features Communication Capabilities (SCADA, Modbus, Ethernet, etc.) Provided benefits include: Competitive Footprint Maintenance Switch Feature Available REA Relay Arc Flash System © BU 3101 Low Voltage Systems April 19, 2017 | Slide 35

© BU 3101 Low Voltage Systems April 19, 2017 | Slide 36 36