Mass spectrometry 8/23/12 What are the principles behind MS?

Slides:



Advertisements
Similar presentations
Instrumental Analysis
Advertisements

FC-MS from Teledyne Isco CombiFlash ® a Name You Can Rely On.
Ion Sources Some characteristics of ion sources (especially in high precision work): It should have high efficiency in generating ions of the element of.
Atomic Mass Spectrometry Yongsik Lee Introduction ► Atomic mass spectrometry  Versatile and widely used tool  All elements can be determined ►
Mass spectroscopy. In a typical MS procedure:  1- a sample is loaded onto the MS instrument, and undergoes vaporization.  2- the components of the sample.
Mass Spectroscopy Skyline IB Chemistry HL Mass Spectroscopy.
Ion Sources Some characteristics of ion sources (especially in high precision work): It should have high efficiency in generating ions of the element of.
AAS and FES (Ch 10, 7th e, WMDS)
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
12-1 Molecular Mass Spectroscopy Molecular structure Composition of mixtures Molecular mass spectra Ion Source Mass Spectrometers Applications.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Flame photometry.
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Chem. 133 – 4/28 Lecture. Announcements Lab Report 2.3 due Today Pass back graded materials (lab reports 2.2, Q5, and AP3.1) Today’s Lecture Mass Spectrometry.
Chapter 20 Molecular Mass Spectrometry. Introduction... Mass spectroscopy is perhaps one of the most widely applicable of all the analytical tools available.
Instrumental Chemistry Chapter 11 Atomic Mass Spectrometry.
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
Atomic Mass Spectrometry
Molecular Mass Spectroscopy Chem Introduction In Mass Spectroscopy (MS), atomic and molecular weights are generally expressed in terms of atomic.
Atomic Mass Spectrometry
Mass Spectrometry.
Mass Spectroscopy 1Dr. Nikhat Siddiqi. Mass spectrometry is a powerful analytical technique that is used to identify unknown compounds, to quantify known.
6. Mass Spectrometry Adv. Inst. Techs. How does it work? a very small amount of sample is bombarded by a beam of high energy (usually electron beam) produces.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Types of Analyses Single Collector –Uses only one collector or detector –This is the case with a Daly or EM Advantages: –Need only one detector –Peaks.
Gas Chromatography And Mass Spectrometry
Mass Spectrometer Mass spectrometere is a very powerful method to analyse the structure of organic compounds.
BALZ S. KAMBER Laurentian University Ultra-high purity ICP-MS.
Agilent 7500 ICP-MS Date: 28JUL2005.
Lecture 1 INTRODUCTION TO INSTRUMENTAL ANALYSIS Copyright ©The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Typical chronometers. LA-ICPMS and SIMS challenges from ~
Secondary Ion Mass Spectrometry (SIMS)
Atomic Emission Spectroscopy
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
GCMS: gas chromatography and mass spectrometry
PC4250 Secondary Ion Mass Spectrometry (SIMS). What is SIMS? SIMS is a surface analysis technique used to characterize the surface and sub-surface region.
Secondary ion mass spectrometry (SIMS)
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Molecular mass spectrometry Chapter 20 The study of “molecular ions” M + e -  M e -
1 Chemical Analysis by Mass Spectrometry. 2 All chemical substances are combinations of atoms. Atoms of different elements have different masses (H =
Mass Spectroscopy 1 Mass Spectroscopy (Mass Spec) Applying Atomic Structure Knowledge to Chemical Analysis.
Measurement of “Difficult” Elements and Isotopes Using a Hexapole ICPMS Zenon Palacz, Simon Meffan-Main. Micromass U.K. Ltd.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Chemistry Topic: Atomic theory Subtopic : Mass Spectrometer.
7-1 Atomic Mass Spectroscopy General Features Mass Spectrometers §Sources Atomic mass spectroscopy determines elements by mass §Mass to charge ratio §Lower.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
Eliminating Molecular Interferences in ICP-MS for the Simplest Method Development Dr. Torsten Lindemann.
Chromatography and Instrumentation. Chromatography Separate Analyze Identify Purify Quantify Components Mixture Chromatography is used by scientists to:
THE MASS SPECTROMETER describes how a mass spectrum is produced using a mass spectrometer.
Mass Spectrometry Relative atomic masses and the mass of individual isotopes can be determined using a mass spectrometer. The principle behind mass spectrometry.
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
1 In-house Training on ICP-MS. ICP-MS??? Inductively Coupled Plasma Mass Spectrometry or ICP-MS is an analytical technique used for elemental determinations.
CHEM133 Mass Spectrometry: Lecture 1
Atomic structure L.O. To be able to recall definitions of relative atomic, isotopic and molecular mass. To demonstrate an understanding of the basic.
Components of Mass Spectrometer
Continuous Flow Isotope Ratio Mass Spectrometry
Atomic structure L.O. 1. To be able to recall definitions of relative atomic, isotopic and molecular mass. 2. To learn about the key principles of mass.
Chem. 133 – 4/13 Lecture.
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Instrumental Chemistry
How do we get those numbers? Or What’s in the “Black Box”?
The Mass Spectrometer.
Molecular Mass Spectroscopy
CHROMATOGRAPHY.
Suppose we make a new compound containing of C,H, and N
Presentation transcript:

Mass spectrometry 8/23/12 What are the principles behind MS? What do all MS instruments have in common? What are the different types of MS? Lecture outline: Introduction to mass spectrometry sample introduction systems, mass analyzers popular combinations in geosciences JJ Thomson’s cathode ray tube, 1897

Introduction to Mass Spectrometry Sample introduction Count ions Separate masses Collect results Ionization Minimize collisions, interferences Nier-type mass spec

Basic equations of mass spectrometry Ion’s kinetic E function of accelerating voltage (V) and charge (z). Centrifugal force Applied magnetic field balance as ion goes through flight tube Combine equations to obtain: Fundamental equation of mass spectrometry Change ‘mass-to-charge’ (m/z) ratio by changing V or changing B. NOTE: if B, V, z constant, then:

If: B in gauss r in centimeters m in amu V in volts z in electronic charge then…. What magnetic field strength would be required to focus a beam of CO2+ ions on a collector of a mass spectrometer whose analyzer tube as a radius of 31.45cm, assuming a voltage of 1000V? Change your magnetic field strength by -10%, what voltage puts the CO2 ions into the collector?

Examples of mass spec data output Ex: B You can scan in B or V to sweep masses across a single detector. OR You can put different masses into multiple cups without changing B or V.

Sample Introduction Systems (aka “front ends”) 1) Gas source (lighter elements) dual inlet - sample purified and measured with standard gas at identical conditions precisions ~ ±0.005% continous flow - sample volatized and purified (by EA or GC) and injected into mass spec in He carrier gas, standards measured before and after, precisions ~ 0.005-0.01% 2) Solid source (heavier elements) TIMS - sample loaded onto Re filament, heated to ~1500°C, precisions ~0.001% laser ablation - sample surface sealed under vacuum, then sputtered with laser precisions ~0.01%? 3) Inductively coupled plasma (all elements, Li to U) ICPMS - sample converted to liquid form, converted to fine aerosol in nebulizer, injected into ~5000K plasma torch

Ionization occurs in the ‘source’ Electron Ionization Gas stream passes through beam of e-, positive ions generated. Thermal Ionization Plasma: Gas stream passes through plasma maintained by RF current and Ar. Themal: Filament heated to ~1500C

Mass Analyzers - the quadrupole vs. magnetic sector Changes DC and RF voltages to isolate a given m/z ion. PRO: cheap, fast, easy Magnetic Sector: Changes B and V to focus a given m/z into detector. PRO: turn in geometry means less ‘dark noise’, higher precision

A) Faraday collector - long life, stable, for signals > 2-3e6 cps Two types of ion detectors A) Faraday collector - long life, stable, for signals > 2-3e6 cps B) Electron multiplier - limited life, linearity issues, high-precision, signals < 2e6 cps

Popular combinations Gas source Solid source ICP 1) Dual inlet isotope ratio mass spec (at GT, Lynch-Steiglitz and Cobb) - O, C, H ratio analyses 2) Elemental analyzer IRMS (at GT, Montoya) - N, C, S ratio analyses 3) Gas chromatograph IRMS (at GT, Chemistry) - compound-specific ratio analyses Solid source 1) Thermal Ionization mass spec (multi-collector) - heavy metals, REE ICP 1) ICP quadrupole mass spec (at GT, Taillefert) - trace metal analysis 2) Single collector magnetic sector ICPMS - higher-precision trace metal analysis 2) Multi-collector ICPMS (nearest at USC) - U/Th dating, TIMS replacement Micromass IsoProbe - MC-ICPMS

Inductively Coupled Plasma Mass Spectrometry detector Shared components of all ICPMS machines mass/charge discriminator high vacuum 10-7 bar sample cone skimmer cone “fore” vacuum 10-4 bar instrument housing atmospheric pressure

and ion counter (electron multiplier) Quadrupole ICPMS - measure concentrations as low as several ppt - no fuss sample preparation (dissolve in 5% HNO3) - get beam intensity vs. mass/charge ratio or magnetic sector Faraday cup and ion counter (electron multiplier)

The torch box of an Agilent 7500 ICPMS spray chamber Ar feed torch RF coil The sample cone isolates the torch from the interior.

ICPMS plasma torch schematic plasma components

High-resolution ICPMS aka double-focusing ICPMS aka magnetic sector ICPMS - same front end as Q-ICPMS - combines magnet w electrostatic analyzer electrostatic analyzer separates ions by charge magnet separates ion by mass Faraday cup and EM

Multi-collector ICPMS 3. MC-ICPMS - same front end as other ICPMS - same magnet and ES as HR-ICPMS - multiple detectors spaced 1amu apart enable simultaneous measurement of many (~7) isotopes -good for what kinds of systems?

Low vs. High – resolution ICPMS and Interferences very low concentrations in environmental samples, but high interest (why?) Unfortunately, 56Fe has the same atomic wt as ArO (40Ar+16O) Quadrupole measurement = INTERFERENCE! HR-ICPMS measurement = can distinguish 56Fe from ArO NOTE: most elements can be distinguished with a low resolution quadrupole

The importance of standards in mass spectrometry ICPMS: Can determine concentration to ~1% R.E. using calibration curve (below) Can monitor Sensitivity (signal response for given solution concentration) over time unknown sample = 8.2e7 cps, conc ~ 10.5ppb

REMEMBER: all mass spectrometers are “black boxes”  we really have no idea what goes on from sample container to detector signal Ex: you measure a count-rate of 10,000 cps for a given element, but you need to know how many atoms of that element, or its concentration, were in your sample measuring isotope ratios is a powerful approach because we can measure samples against standards with known isotopic ratios (it’s much more difficult to change a material’s isotopic ratios than it is to change its elemental concentration!) isotope dilution takes advantage of ability to precisely measure ratios ALL measurements need to include blanks and standards (either concentration or ratio standards)

Isotope dilution principle Isotope dilution is an analytical technique used in combination with mass spectrometry to determine the concentration of element x in unknown samples. ex: Rb A known amount of “spike” with known elemental concentration and isotopic abundances (what’s the diff?) is added to sample with unknown elemental concentration but known isotopic abundances. Requirements: The sample has natural (or known) isotopic abundance (usually true). The spike and sample isotopic ratios are different.

More Commonly used ICPMS terms Nebulization efficiency – the amount of solution that reaches the plasma (~1%) - varies with sample matrix - surface tension, viscosity, and density of solution will affect neb. eff. - usually all standards, spikes, and samples are introduced as 2-5% HNO3 - an acid solution reduces complexation, surface adsorption Matrix effects – the changes in ICP characteristics with variable matrices - largely black box (we see these effects, cannot wholly explain/predict them) - you must carefully match the matrices of your standards/samples to obtain quantitative results Ionization efficiency – the amount of ions produced per atoms introduced - depends on matrix, focusing of beam through cones, lenses - usually no better than 1/1000

ICP detection limits for a variety of elements ICP-OES ICP-MS Detection limit – defined as 3 x the S.D. of the signal as the concentration of the analyte approaches 0 (measure stability at a variety of conc’s, extrapolate to 0; or measure 5% HNO3 blank solution)

Perkin Elmer Quadrupole ICPMS Instrument Detection limits, 3σ

Ion microprobe (or Secondary Ion Mass Spectrometry  SIMS) use an ion beam (usually Cs+1) to “sputter” a sample surface; secondary ions fed into mass spec 20μm

Accelerator Mass Spectrometry The AMS at University of Arizona (3MV) prior to AMS samples were 14C-dated by counting the number of decays - required large samples and long analysis times -1977: Nelson et al. and Bennett et al. publish papers in Science demonstrating the utility of attaching an accelerator to a conventional mass spectrometer Principle: You cannot quantitatively remove interferring ions to look for one 14C atom among several quadrillion C atoms. Instead, you destroy molecular ions (foil or gas) filter by the energy of the ions (detector) to separate the needle in the haystack. The AMS at LLNL (10MV)

c) ACCELERATOR generates 2.5 million volts, accelerates C- ions b) INJECTOR MAGNET separates ions by mass, masses 12, 13, and 14 injected d) TERMINAL C- ions interact with ‘stripper’ gas Ar, become C+ ions, molecular species CH destroyed e) ELECTROSTATIC DEFLECTOR specific charge of ions selected (3+) a) ION SOURCE generates negative carbon ions by Cs sputtering f) MAGNETIC SEPARATION 13C steered into cup, 14C passes through to solid detector g) Si BARRIER DETECTOR pulse produced is proportional to the energy of ion, can differentiate b/t 14C and other ions count rate for modern sample = 100cps http://www.physics.arizona.edu/ams/education/ams_principle.htm

Hurdles in mass spectrometry 1) Abundance sensitivity - ratio of signal at mass m to signal at m+1 - better with better vacuum - acceptable values: 1-3ppm at 1amu 2) Mass discrimination - heavier atoms not ionized as efficiently as light atoms - can contribute 1% errors to isotope values - can correct with known (natural) isotope ratios within run, or with known standards between runs

Hurdles in mass spectrometry (cont.) 3) Dark Noise - detector will register signal even without an ion beam - no vacuum is perfect and - no detector is perfect - must measure prior to run to get “instrument blank” if needed 4) Detector “gain” - what is the relationship between the electronic signal recorded by the detector and the number of ions that it has counted? - usually close to 1 after factory calibration - changes as detector “ages” - must quantify with standards Cardinal rule of mass spectrometry: Your measurements are only as good as your STANDARDS! Standards (both concentration and isotopic) can be purchased from NIST

Ex: NBS-19, O, C carbonate isotopic standard