Development of ‘multi-color’ optical soft X-ray arrays for MHD and transport diagnostics in fusion experiments L. F. Delgado-Aparicio, D. Stutman, K. Tritz,

Slides:



Advertisements
Similar presentations
Studying the Physical Properties of the Atmosphere using LIDAR technique Dinh Van Trung and Nguyen Thanh Binh, Nguyen Dai Hung, Dao Duy Thang, Bui Van.
Advertisements

J. Boedo, UCSD UCSD Program at NCSX J. Boedo for The UCSD and NCSX Teams.
High speed images of edge plasmas in NSTX IEA Workshop Edge Transport in Fusion Plasmas September 11-13, 2006 Kraków, Poland GPI outer midplane – shot.
Design and tomography test of edge multi-energy soft X-ray diagnostics on KSTAR PPPL, Feb. 18, 2014 Juhyeok Jang*, Seung Hun Lee, H. Y. Lee, Joohwan Hong,
V. A. Soukhanovskii (LLNL) Acknowledgements: J. Abramson, R. E. Bell, A. L. Roquemore, R. Kaita, H. W. Kugel, G. Tchilinguirian, P. Sichta, G. Zimmer (PPPL),
Page 1 © J. Paul Robinson, Purdue University BMS 602/631 - LECTURE 8 Flow Cytometry: Theory Purdue University Office: Fax
Crystals and related topics J. Gerl, GSI NUSTAR Calorimeter Working Group Meeting June 17, 2005 Valencia.
Magnetic Reconnection Rate and Energy Release Rate Jeongwoo Lee 2008 April 1 NJIT/CSTR Seminar Day.
Lecture 2-Building a Detector George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
Page 1 © J.Paul Robinson, Purdue University BMS 631 – LECTURE007.PPT BMS 602/631 - LECTURE 8 Flow Cytometry: Theory J. Paul Robinson Professor.
Liquid Helium Scintillation T. Wijnands EN/HDO Candidate for detecting beam losses in the LHC ?
V. A. Soukhanovskii Lawrence Livermore National Laboratory, Livermore, CA Acknowledgements: R. Kaita a, A. L. Roquemore a, K. Tritz b a Princeton Plasma.
Jungmin Jo, Jeong Jeung Dang, Young-Gi Kim, YoungHwa An, Kyoung-Jae Chung and Y.S. Hwang Development of Electron Temperature Diagnostics Using Soft X-ray.
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
Fast imaging of global eigenmodes in the H-1 heliac ABSTRACT We report a study of coherent plasma instabilities in the H-1 plasma using a synchronous gated.
Photon detection Visible or near-visible wavelengths
Vacuum Photodiodes for Soft X-Ray ITER Tomography Yu.Gott, M.Stepanenko 10th ITPA Meeting, Moscow, 2006.
Nils P. Basse Plasma Science and Fusion Center Massachusetts Institute of Technology Cambridge, MA USA ABB seminar November 7th, 2005 Measurements.
PMTs & APDs, Components Of An "Optical" SXR Diagnostics For MFE Plasmas Luis F. Delgado-Aparicio V. The Plasma Spectroscopy Group The Johns Hopkins University.
2D Position Sensitive Detector for Plasma diagnosis
10th ITPA TP Meeting - 24 April A. Scarabosio 1 Spontaneous stationary toroidal rotation in the TCV tokamak A. Scarabosio, A. Bortolon, B. P. Duval,
Si Nanocrystaline Diamond Foil Hibachi Window Testing and Development Background and Theory Pulsed Power System Electron Beam Electron Transmission Window.
V. A. Soukhanovskii 1 Acknowledgements: M. G. Bell 2, R. Kaita 2, H. W. Kugel 2, R. Raman 3, A. L. Roquemore 2 1 Lawrence Livermore National Laboratory,
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
V. A. Soukhanovskii 1 Acknowledgement s: R. Maingi 2, D. A. Gates 3, J. Menard 3, R. Raman 4, R. E. Bell 3, C. E. Bush 2, R. Kaita 3, H. W. Kugel 3, B.
First results from Transmission Grating Imaging Spectrometer D. Kumar, D. Stutman, K. Tritz, M. Finkenthal Plasma Spectroscopy Group, Department of Physics.
1 B. C. Stratton, S. von Goeler, J. Robinson, and L. E. Zakharov Princeton Plasma Physics Laboratory, Princeton, New Jersey, USA D. Stutman and K. Tritz.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
1 Results and analysis of Gas Puff Imaging experiments in NSTX: turbulence, L-H transitions, ELMs and other phenomena R.J. Maqueda Nova Photonics S.J.
Characterization of core and edge turbulence in L- and H-mode Alcator C-Mod plasmas Outline: Alcator C-Mod tokamak Fluctuation diagnostics Low to high.
T.M. Biewer, Oct. 20 th, 2003NSTX Physics Meeting1 T. M. Biewer, R.E. Bell October 20 th, 2003 NSTX Physics Meeting Princeton Plasma Physics Laboratory.
Prototype Multi-Energy Soft X-ray Diagnostic for EAST Kevin Tritz Johns Hopkins University NSTX-U Monday Physics Meeting PPPL, Princeton, NJ June 25 th,
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
1 C. E. Bush (ORNL), B. C. Stratton, S. von Goeler, J. Robinson, L. E. Zakharov, E. Fredrickson (PPPL) D. Stutman and K. Tritz (JHU) and the NSTX Team.
Tangential multi-color “optical” soft X-ray array for fast electron temperature and transport measurements L. F. Delgado-Aparicio, D. Stutman, K. Tritz,
Pellet Charge Exchange Measurement in LHD & ITER ITPA Tohoku Univ. Tetsuo Ozaki, P.Goncharov, E.Veschev 1), N.Tamura, K.Sato, D.Kalinina and.
Advances In High Harmonic Fast Wave Heating of NSTX H-mode Plasmas P. M. Ryan, J-W Ahn, G. Chen, D. L. Green, E. F. Jaeger, R. Maingi, J. B. Wilgen - Oak.
Supported by Imaging the Pedestal Island Structure during the Application of 3D Magnetic Perturbations Office of Science D.J. Battaglia 1*, M.W. Shafer.
Brent Stratton for the NCSX Team Princeton Plasma Physics Laboratory Oak Ridge National Laboratory NCSX Program Advisory Committee Meeting #8 Princeton.
VVS Prototype Construction at Fermilab Erik Ramberg 26 February,2002 Design issues for VVS Details of VVS prototype design Schedule and Budget Testing.
‘Multi-color’ optical soft X-ray arrays for MHD and transport diagnostics L. F. Delgado-Aparicio, D. Stutman, K. Tritz G. Suliman and M. Finkenthal The.
PHYSICS 225, 2 ND YEAR LAB NUCLEAR RADIATION DETECTORS G.F. West Thurs, Jan. 19.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
1 Imaging X-Ray Crystal Spectrometer with Fast Detector for Fast Measurement of Profiles of Ti and Intrinsic Plasma Rotation Velocity without Perturbation.
Comparison between X-ray measurements with the GEM detector and EFIT calculations Danilo Pacella Present address: JHU, Baltimore, MD Permanent address:
Edge Turbulence in High Density Ohmic Plasmas on NSTX K.M. Williams, S.J. Zweben, J. Boedo, R. Maingi, C.E. Bush NSTX XP Presentation Draft 5/25/06.
El-Mul Technologies Ltd – Confidential & Proprietary El-Mul Technologies El-Mul Technologies Ltd – Confidential & Proprietary Prof. Eli Cheifetz, Chairman.
V. A. Soukhanovskii Lawrence Livermore National Laboratory H. W. Kugel, R. Kaita, A. L. Roquemore Princeton Plasma Physics Laboratory NSTX Research Team.
1 Progress of the Thomson Scattering Experiment on HSX K. Zhai, F.S.B. Anderson, D.T. Anderson HSX Plasma Laboratory, UW-Madison Bill Mason PSL, UW-Madison,
T. Biewer, March 3 rd, 2003NSTX Physics Meeting Measurements of Edge Impurity Ion Dynamics During RF Heating T. M. Biewer, R.E. Bell March 3 rd, 2003 NSTX.
Scaling experiments of perturbative impurity transport in NSTX D. Stutman, M. Finkenthal Johns Hopkins University J. Menard, E. Synakowski, B. Leblanc,R.
APS, 44th Annual Meeting of the Division of Plasma Physics November 11-15, 2002; Orlando, Florida Hard X-ray Diagnostics in the HSX A. E. Abdou, A. F.
Initial Results from the Scintillator Fast Lost Ion Probe D. Darrow NSTX Physics Meeting February 28, 2005.
53rd Annual Meeting of the Division of Plasma Physics, November 13 – November 18, 2011, Salt Lake City, UT Laser Blow-Off Impurity Injection Experiments.
Pedestal Characterization and Stability of Small-ELM Regimes in NSTX* A. Sontag 1, J. Canik 1, R. Maingi 1, J. Manickam 2, P. Snyder 3, R. Bell 2, S. Gerhardt.
Neutral beam ion loss measurement and modeling for NSTX D. S. Darrow Princeton Plasma Physics Laboratory American Physical Society, Division of Plasma.
1 B. C. Stratton, S. von Goeler, and R. Feder PPPL J. Lowrance, V. Mastrocola, and G. Renda Princeton Scientific Instruments NSTX Physics Meeting June.
52nd Annual Meeting of the Division of Plasma Physics, November 8 – November 12, 2010, Chicago, IL Development of Laser Blow-Off Impurity Injection Experiments.
T. Biewer, Sep. 20 th, 2004 NSTX Results Review of 11 Edge Ion Heating by Launched HHFW in NSTX T.M. Biewer, R.E. Bell, S. Diem, P.M. Ryan, J.R.
Gamma Ray Spectrometry System Design for ITER Plasma Diagnostics
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
Associazione EURATOM-ENEA sulla Fusione
Preliminary study for Soft X-ray Spectroscopy in VEST
2013 KAPRA & KPS/DPP Conference
Impurity Transport Research at the HSX Stellarator
BMS 602/631 - LECTURE 7 Flow Cytometry: Theory
Review of spectroscopic diagnostic at COMPASS tokamak
D. S. Darrow Princeton Plasma Physics Laboratory
PbWO4 Cherenkov light contribution to Hamamatsu S8148 and Zinc Sulfide–Silicon avalanche photodiodes signals F. KOCAK, I. TAPAN Department of Physics,
Presentation transcript:

Development of ‘multi-color’ optical soft X-ray arrays for MHD and transport diagnostics in fusion experiments L. F. Delgado-Aparicio, D. Stutman, K. Tritz, G. Suliman and M. Finkenthal The Plasma Spectroscopy Group The Johns Hopkins University R. Kaita, L. Roquemore and D. Johnson Princeton Plasma Physics Laboratory American Physical Society (APS), Division in Plasma Physics (DPP), November, , 2004 Savannah, GA, USA

Abstract We are developing fast (  100kHz), “multi-color” (multi-energy) optical soft x-ray arrays as an improved alternative to conventional photodiode arrays for MHD and transport diagnostic. Tests of a “single-color” array on NSTX show that the optical device has SNR and immunity to noise, superior to those of conventional diode arrays, while having similarly fast time response [1]. In addition, the optical design enables improved plasma access and spatial coverage at reduced cost, making possible large channel- count, “multi-color” tomographic systems. Due to the “layered” structure of the plasma emissivity, such systems would enable simultaneous imaging from the plasma edge to the core. A re-entrant “multi-color” OSXR array will be prototyped on NSTX, where it will also augment the coverage of the existing diode system. The optimization of this diagnostic is discussed and applications of the “multi-color” technique illustrated with NSTX results and numerical simulations. [1] Luis F. Delgado-Aparicio, et al., Rev. Sci. Instrum, 75, 4020, (2004).

“Classical” soft x-ray (SXR) photodiode arrays Basic diagnostic: A SXR system (based on filters & photodiode arrays) does 2D tomographic reconstructions in a well defined (and limited) energy range, mainly for diagnostics of core and edge MHD activity. Current USXR system in NSTX Why only at a well defined & limited energy range?  FILTER’s TRANSMISSION

“Classical” soft x-ray (SXR) photodiode arrays Limitations: 1. Due to “layered” structure of the plasma emissivity as a function of energy, important core perturbations are “hidden” by strong peripheral edge emission  need to peel off the peripheral contribution (onion model)! Current USXR system in NSTX 2/1 + 1/1 E > 0.4 keV (5 µm Be filter) Mid-plane Z (cm) 1/1 t(ms) m/n modes E > 1.4 keV (100 µm Be filter)

“Classical” soft x-ray (SXR) photodiode arrays Current USXR system in NSTX Limitations: 2. Tomographic reconstruction of complex structures requires a very large # of integration chords (  300), therefore, such an array would be prohibitively expensive. 3. Lack of plasma access due to a tight fitting vacuum vessel, access to ports, port space and geometry, and # of ports become an engineering issue. 4. In-vacuum diode SXR cameras have to be designed accordingly, in order to sustain elevated bake-out temperatures (300 o C) and UHV conditions (10 -7 torr). 5. The NBI-high neutron flux induced noise and fast electromagnetic activity (or current ramp up/down), impair the silicon-based diode arrays with transients “triangularly shaped peaks” and permanent defects.

Classical” soft x-ray (SXR) photodiode arrays Current USXR system in NSTX Solution: In order to solve the above problems we proposed to REPLACE the filtered diode system with a multi-color (multi-energy) re-entrant (in-vacuum) “optical” SXR system. Such system enables simultaneous time, space and energy resolved ‘multi-color’ tomographic measurements. Concepts to have in mind: Multi-color : technique with different filters (or cutoff energies) so MHD phenomena from the core to the peripheral edge can be simultaneously recorded in time using the SAME integration chords (observed from the same toroidal locations, for instance). Re-entrant : system witch satisfies bake-out temperatures (300 o C) and UHV (10 -7 torr) requirements. “Optical” : system that uses columnar (crystal growth procedure) thallium doped cesium iodine thallium (CsI:Tl) to efficiently convert SXR photons to visible light!

What is an “optical” soft x-ray (OSXR) array system? OSXR array head tested on CDX-U & NSTX spherical tokamaks [1] It’s a system that uses a fast (  1  s) and efficient scintillator (CsI:Tl) in order to convert soft x-ray photons (0.1<E ph <6 keV) to visible green light (  550 nm). [1] Luis F. Delgado-Aparicio, et al., Rev. Sci. Instrum, 75, 4020, (2004). CsI:Tl deposited on a FOP Vacuum side Air side

Components of the “optical” SXR Array  m Ti and 0.5, 5, 50 and 100  m Be foils 2.Columnar (crystal growth) CsI:Tl (30  m) deposited on a 2mm fiber optic plate (FOP, NA  1) mm in diameter, 1/3” thickness UHV fiber optic window (6” CF). 4.Hi throughput, multi-clad, non- scintillating, 1.5 m long fiber optics (NA  0.7  T  40%). 5.Current pre-amplifiers ( V/A). 6.Current detector: Bi-alkali (Sb- Rb-Cs, Sb-K-Cs), multi-anode, low cross talk, high gain (  10 6 ) Hamamatsu photo-multiplier tube (PMT). Magnetic shielding is necessary! 7.Future candidate: Advanced Photonix’s large area avalanche photodiode (APD). One channel, 5 mm in diameter, modified, hi quantum efficiency (  90%), high internal gain (  300), internally amplified, cooled (-20 to 0 o C) module. NOTE: NaI (hygroscopic scintillator) has been used for 1D ion heating studies in a magnetic reconnection current sheet (N. Ohyabu, PoF, 17, 2009, 1974).

“Optical” array installation in NSTX (PPPL) Fiber optic window, 5  m Be filter and CsI:Tl scintillator, mounted on an 8” gate valve. Hi throughput, multi-clad, non-scintillating, 1.5 m long fiber optics (NA  0.7  T  40%). PMT aluminum box with: a)0.05” thick  -metal, and 1/4”- 2.0 kg iron cylinder and lids for magnetic shielding. b)Delrin-based structure for fiber optics support and alignment. c)Attached electronics.

Results from NSTX (PPPL) R o = 85 cm a = 68 cm A = R o /a ~ 1.25 B T (0) = T I p < 1.5 MA  (elongation)    discharge  1 s T e (0) ≤ 1.5 keV n e (0)   m -3 P NB  MW P HHFW  1 MW The “OSXR” array have been compared with the present SXR arrays used for tomographic reconstruction and MHD studies.

Test of a “single-color” array in NSTX (PPPL) MHD results with the “OSXR” shown at High Temperature Plasma Diagnostics meeting (San Diego, 2004) & Rev. Sci. Instrum, 75, 4020, (2004). Shot #:  Ohmic Shot Shot #:  H-mode

Benefits of the “OSXR” system (I) 1.Compactness & portability. 2.Almost unrestricted plasma accessibility (multiple toroidal & poloidal locations). 3.The initial photon statistics is conserved due to optimized scintillation (CsI:Tl) properties. 4.Electronics far away of the machine. 5.Less expensive than the diode system ($). 6.The gain of the system can be remotely changed by the use of a PMT and/or an APD.

Benefits of the “OSXR” system (II) 7.Optically thin to neutron bombardment. Shot #114022,  0.8 MA, 2-4 MW NBI, 1.0  n/s The NB-induced noise in the Si- based photodiode system seem to be due to elastic and inelastic scattering of 2.5 MeV DD neutrons in the photodiode’s silicon lattice. NSTX Shot # (2 - 4 MW NBI) Diode SXR Optical SXR Noise comparison between diode and “optical” SXR arrays NBI

Benefits of the “OSXR” system (III) 8.The time response of the OSXR system is comparable to that of the AXUV photodiodes (2-4  s). Fast ELM measured with H up diode array Chord# t (ms) Diode SXR Optical SXR The time difference from peak intensities is approximately 50  s, and only indicates that the mode passed in front of the detectors in its trajectory from the bottom divertor to NSTX's midplane. G amp = 10 7 V/A (400 kHz) Remote controlled Femto current pre-amplifier Hamamatsu H8711 Multi-anode TTS (FWHM)  0.4 ns +

What is a re-entrant (in vacuum) “optical” SXR array? Optimization OSXR array head tested on NSTX NSTX (2005) 1.Scintillator 2.Reflective coating 3.Fiber optic plates (FOP) 4.Filter transmission. 5.In vacuum fiber optics 6.Fiber optic window (FOW) 7.Atmosphere fiber optics 8.PMT and/or APD 9.Trans-impedance amplifier 10.DAQs It’s a system based on the OSXR concept with an optimized plasma access. The so-called “re-entrant” system will have the “FOP+scintillator” combo located INSIDE the tokamak, and the extraction of light will be done with a 1-D “ribbon” of UHV compatible fiber optic bundles!

What is a re-entrant “multi-color” OSXR system? OSXR array head tested on NSTX NSTX (2005) It’s a system based on the OSXR concept with an optimized plasma access and the capability of recording MHD phenomena from the core to the periphery SIMULTANEOUSLY!

What can a re-entrant multi-color OSXR can do? Multi-color (2-3 color) tomographic reconstructions. Time & space dependent transport measurements of intrinsic (e -, ions and C) and injected (neon) impurities; including SGI. MHD mode recognition (ELMs & RWMs) and their effects on core & edge plasma parameters. ELMs characterization & perturbative effects (see K. Tritz, et al., poster JP1.031). ‘Two -color’ modeling of T e perturbations during MHD events (NEXT SLIDE).

“Two -color” modeling of T e perturbations during MHD events The ratio of low to high energy USXR signals is T e sensitive (MPTS) USXR profiles modeled using C, O and B coronal equilibrium radiative coefficients. Chord # t (ms) T e (keV) R (cm) How sensitive is this method ? First assessment (proof of principle, using a type-I ELM) Using the diode-based SXR system in NSTX! MPTS USXR Compare with MPTS The correct application of the ‘multi-color’ technique requires imaging the SAME plasma region, rather than piecing together images from different plasma regions at different energies. METHOD

Tangential multi-color OSXR for NSTX Enhancement of radiation over bremsstrahlung due to free-bound (recombination) radiation; caused predominately by highly ionized carbon. Mid-plane tangential reconstruction Emissivity Brightness multi-energy cut m m

16 to 48 channels of a multi-color (2 or 3 cutoff filters) OSXR array, mechanically attached and optically coupled to FOP & FOW. PMT aluminum box with: a)0.05” thick  -metal, and 1/4”-2.0 kg iron cylinder and lids for magnetic shielding. b)Delrin-based structure for fiber optics support and alignment. c)Attached electronics with PMTs, trans-impedance amplifiers and RG-58 coaxial cables. Poloidal multi-color OSXR for NSTX Hi throughput, multi-clad, non-scintillating, 1.5 m long fiber optics (NA  0.7  T  40%).

Components 30  m CsI:Tl (RMD, Inc) deposition on a 2 mm FOP (Collimated Holes, Inc). Ti and Be filters (Lebow, Inc) Vacuum compatible fiber optic bundle (L= m) with epoxied NA=0.64, 50  m individual fiber optics (Collimated Holes, Inc). Fiber optic window (XRSINC) 1.5 m, NA=0.74, fiber optic canes (Bicron - Saint Gobain). AXUV (IRD, Inc) and/or PMT (Hamamatsu) In-vacuum fiber optic test k  x-rays from Manson SXR source CsI:Tl visible 550 nm green light CsI:Tl visible 550 nm green light Epoxied Fused Assembled fiber optics

In-vacuum fiber optic test (II) Manson source 90 o Anodes k  x-ray beam 1 Beam 2 Point-like Al-k  (1486 eV) emissivity:  5  photons/st  s 2-3/4” flange BNC ceramic break k  SXR lines 5  m Be foil Filter CsI:Tl FOP AXUV 100 We need to determine first how much visible light we can collect from the conversion of Al k  (8.35 Å) into green (550 nm) light from CsI:Tl a)Experiment with Be filter, and AXUV-100  I x-rays = 79 nA b)Experiment with Be filter, CsI:Tl + FOP and AXUV-100  I visible = 4.1 nA (next slide) CE CsI:Tl (E=1486 eV)  37   26/keV CsI:Tl conversion efficiency check  10 mm

In-vacuum fiber optic test (III) FO Bundle (Collimated Holes, Inc.) FO bundle active area SS ferrule Fiber optic window Filter CsI:Tl FOP (to be completed with experiments at Johns Hopkins)

Conclusions A single-color “OSXR” array has been successfully tested on NSTX. The time response of the system is in the order of  s, thus the system would be able to be sampled at frequencies in the order of kHz. The NB-induced noise in the diode system seems to be due to elastic and inelastic scattering of 2.5 MeV DD neutrons in the photo-diode’s silicon lattice. The “optical” SXR array appears to be “thin” to neutron bombardment in comparison to the photo-diode (silicon) based arrays. A re-entrant ‘multi-color’ OSXR array has been proposed to replace the photo- diode based USXR system in NSTX and thus, correctly apply the ‘multi-color’ technique for MHD mode recognition and transport measurements. Tests of in-vacuum fiber optic bundles have been done at the JHU laboratories for NSTX and NCSX applications.

Current applications Comparison between PMT and APD technologies. Time response and sensitivity for UV/visible light. Test with columnar CsI:Tl ( MHz). Development of optical array for turbulent SXR measurements (see G. Suliman, et. al. poster BP1.088). RWMs, ELMs and neutron impact studies. Correlation between the “optical” array (NSTX Bay J) and the diode arrays (NSTX Bay G). Future plans Test of new fast scintillator (LaCl 3 :Ce) for MFE applications. ( MHz system) Investigation of x-ray tangential imaging for current profile reconstructions. Construction of multi-color x-ray toroidal and poloidal arrays. Development of compact in-vacuum SXR cameras for future devices like NCSX

Acknowledgments The Johns Hopkins University: Scott Spangler and Steve Patterson. Princeton Plasma Physics Laboratory: Robert Majeski, Jeff Spaleta, Tim Gray, Jim Taylor, John Timberlake (CDX-U). James Kukon, Brent Stratton, Joe Winston and Bill Blanchard (NSTX). This work was supported by The Department of Energy (DOE) grant No. DE-FG02-86ER52314ATDOE

Preprints Name Name Name