Volumetric Airflow Gauge M. Chakan, J. Kiswardy, M. Nilo Introduction The United States 911 emergency call center receives an average of 500,000 calls.

Slides:



Advertisements
Similar presentations
Initial Assessment of the Mechanically Ventilated Patient
Advertisements

Model 754 Portable Ventilator
Haptic Glove Hardware Graduation Project Prepared by Yaman A. Salman Eman M. Masarweh 2012.
Developing a tool to monitor and help prevent concussions Instrumented Football Helmet Development Team Joseph Jackson (ME) Adam McCauley (ECE) Shawn Kachnowski.
Experiment 8 : Minor Losses
Chemical Source Localization Using Electronic Nose Sensors Joy Chiang, Vanessa Tidwell, Patricio S. La Rosa, Arye Nehorai Department of Electrical and.
© 2008 Masimo Corporation Includes a review on Carbon Monoxide Poisoning For Emergency Responders V.8 1 May 2011 Monitoring CO Poisoning with the Rad-57.
Case Tools Trisha Cummings. Our Definition of CASE  CASE is the use of computer-based support in the software development process.  A CASE tool is a.
1 LIFECARE PLV-100 by Bryce Younger. 2 Classification ► Electrically powered  microprocessor controlled ► Volume-control, time cycled ► Rotary drive.
Interpretation of Ventilator Graphics
Simulation Proposed Device Modified Helium Dilution 1 Standard Helium Dilution Conclusion Above: Schematic Diagram of the proposed device. Right: Image.
Hardware-in-the-Loop Testbed Team 186. Project Collaborators Team Members: o Aaron Eaddy – EE o Ken Gobin – EE/COMPE o Douglas Pence – ENGR PHYS/EE Team.
Solution Preparation Solvent Mixing. The foundation of analytical chemistry is accurate, documented solution preparation and solvent mixing.
Administering Emergency Oxygen
Design of new speed and acceleration measurement device for wheelchair testing Caitlyn Corey 1, Zachary Mason 2 1 Department of Mechanical Engineering,
New Orleans EMS Airway Lecture Series: Lecture 2 Oxygenation and Bag-Mask Ventilation Jeffrey M. Elder, M.D. Deputy Medical Director.
In Order of Presentation: Ishaan Sandhu DannY Kang Arslan Qaiser Eric Otte Anuar Tazabekov Capacitive Rain Sensor for Automatic Wiper Control.
20 10 School of Electrical Engineering &Telecommunications UNSW UNSW 10 Author: James Carrapetta Supervisor: Dr Vijay Sivaraman Wireless.
ABSTRACT About half a million premature births – one- eighth of all live births – occur in the United States each year. Researchers at the Children’s Hospital.
Lecture161 Instrumentation Prof. Phillips March 14, 2003.
of Experimental Density Data Purpose of the Experiment
Ventilator.
AccuMax Multi-Point Injection Mechanics
Volumetric Airflow Gauge Guy Guimond, UPMC Center for Emergency Medicine Eric Reiss, Systems Manager, Swanson Institute Matthew Chakan Michael Nilo Justin.
Infant Respiratory Rate Monitor Group 11 Sean Ermer Tim Lau Leo Li Mentor: Dr. Daniel Moran.
Second Chance Automated External Defibrillator Pads Defib Task Force Lisa Jiang, Justin Lin, Joanna Nathan, Carl Nelson, Brad.
PIC Evaluation/ Development Board Dec02-12 December 10, 2002 Client: ECpE Department Faculty Advisors: Dr. Rover, Dr. Weber Chad Berg, Luke Bishop, Tyson.
Respiratory Function, Breathing, Respiration
1 In Order of Presentation: Ishaan Sandhu Danny Kang Arslan Qaiser Eric Otte Anuar Tazabekov Capacitive Rain Sensor for Automatic Wiper Control.
Marcos Esterman, Associate Professor Industrial and Systems Engineering Department Rochester Institute of Technology Multidisciplinary.
Group Members: Brad Cox Kevin Burkett Tera Cline Arthur Perkins CS10 Battery Management System.
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
Smart transmitters.
LMA Supreme™ Training LMA North America Inc..
NANS I 3 Steve Adler December 6, Indications for Use U.S. –Infumorph Europe –Morphine and Baclofen.
Team Welcome to Woop Woop Project WiFi Clock. Introduction Team Members  Rosemary Peters  Kirby Wigton  Nate Perkins  Joe Haggberg Advisor Dr. Aziz.
Without reference, identify principles about volume/pressure and high frequency ventilators with at least 70 percent accuracy.
INTRODUCTION TO MEASUREMENT
Effect of different cycling off criteria and positive end-expiratory pressure during pressure support ventilation in patients with chronic obstructive.
In-Vivo Device for Measuring and Adjusting Lap-Band Pressure Mark Fritz 1, John Huidekoper 1, Andrew Koivuniemi 1, David Mayhew 1, Chris Schroeder 1 Robert.
Team Members Cara Dunn Farshad Fahimi Sujan Bhaheetharan Nipun Yamdagni UW/VA Hospitals – Geriatric psychiatrist/Sleep specialist Assistant Professor,
Respiratory Function, Breathing, Respiration BI 233 Exercise 40.
Electronic Circuit Diagrams
Solar Powered Blood Pressure Assist Device Laura Allen 1, James Berry 2, Casey Duckwall 2, David Harris 1 Advisor: Dr. Franz Baudenbacher 2 Department.
Handheld Flow Calibrator for Aerosol Observing System Jonathan Ma, Dung (Yung) Hoang Nguyen, Mario Zuniga Department of Mechanical and Aerospace Engineering,
Portable Patient Training Device for Lung Cancer Treatment Thomas Chia Jason Ethington Brent Geiger Kawai Chan Client: Bhudatt Paliwal, PhD Advisor: Willis.
Chapter 17 Emergency Procedures. Copyright © 2007 Thomson Delmar Learning. ALL RIGHTS RESERVED.2 Protecting the Airway Airway –Structure through which.
Senior Design Craig A. Greiner Senior Design Craig A. Greiner Bioactive Knee Brace Craig Greiner Richard Stoner Jason Woods Zach Mason March 15, 2005.
Presented by: Mark Fraysier Richard Jennings 11/28/2012.
CARDIOHELP TRAINING June 18-19, 2013
Non-Invasive Blood Pressure Device for Use in fMRI Imaging Applications February 18, 2005 Jose Alvarado Benjamin Huh Sanjeet Rangarajan Dr. André Diedrich.
Fault Tree Analysis Volumetric Airflow Gauge Failure Modes Administrator Error Failure to create seal Electrical Failure Design/Casing Failure Improper.
COSTING Blood Glucose watch ComponentPart No.Weight (kg)MaterialMaterial Cost £/kgPart Cost £/kg Plastic casing ABS Plastic casings ABS
EKT 314/4 WEEK 2 : CHAPTER 1 INTRODUCTION TO EI ELECTRONIC INSTRUMENTATION.
Chapter 1: The Nature of Analytical Chemistry
ABSTRACT We present and evaluate a dynamic model to predict blood oxygen saturation from respiration signals for use in automated sleep apnea detection.
Intrapulmonary Percussive Ventilation Carl W. Israel*, Tim Weaver*, James Grotting*, Joshua Gess^, Ryan Winter^, Dr. Paul King * *Department of Biomedical.
ISR: Interrupt Service Routine Program will be interrupt driven.
Taper DPI FeatureImpact Efficacy Safety Compliance Cost High Efficiency  Equivalent lung dose achieved in- vitro with approximately 50% lower delivered.
Small Animal Ventilator for Hyperpolarized Helium MRI Ashley Anderson III, Micah Brown, Matt Smith, Chris Wegener Client: Dr. Sean Fain Advisor: Dr. Willis.
Pressure Ulcer Reducing Wheelchair Pad
Hemodialysis Lecture 3.
Monaghan 225 Ventilator Use Under Hyperbaric Conditions
Improving Simulations in the Post Anesthesia Care Unit
LEC Incorporated 8 February 2005 Group Members: Jen Bacior Amine Hallab Hiroki Meguro Kevin Mihelc Advisors: Kelly Dympna, MD Jack Patzer, PhD Biopsy.
The HemoBlocker: An Innovative Solution Allowing Continuous Ventilation During Massive Respiratory Hemorrhage J. Ignacio Aguilera1, Cesar De la Garza1,
Presentation transcript:

Volumetric Airflow Gauge M. Chakan, J. Kiswardy, M. Nilo Introduction The United States 911 emergency call center receives an average of 500,000 calls daily; of these approximately 35% involve individuals with some type of cardiopulmonary failure. Most common method of initiating breathing in an individual suffering from cardiac arrest or pulmonary failure, aside from CPR, is through the use of a manual resuscitator or bag-valve-mask (BVM) system. Efficacy of resuscitation using a manual BVM is highly dependant on the training and skill level of the user and, as a result, many potential complications exist, the most significant involving over/under inflation of the patients airway. Well documented side-effects include: Lung tissue damage Decreased lung compliance Gastric distension Regurgitation These side-effects frequently lead to co-morbidities involving increased hospital stay and cost incurred by the patient. A solution needs to be presented that would allow the user to better estimate and thereby control the amount of air that is introduced to the patients airway while using a manual BVM system. Project objective was to design a gauge that could be easily incorporated into a manual resuscitation device, providing the user with a constant volumetric display of air introduced to the patient. The device will potentially minimize the undesired side-effects associated with under/over inflation mentioned previously. Materials and Methods The overall design involved two separate components: electrical circuitry (Figure 1), which measures and displays the inspiratory air volume of the BVM to the user, and a casing that houses the circuitry and provides a streamlined product that easily incorporates into existing manual resuscitators. Circuit Design Objectives: 1) Measure an airflow between 0 and 1.6 L/s 2) Sample, calculate, and display the air volume in near real-time 3) Display the volume with a precision of 10 mL 4) Calculate the effective volume of air that entered into the patient’s lungs, by compensating for temperature expansion: V 2 =V 1 *[T 2 /T 1 ] 5) Warn the user when to replace the batteries 6) Provide a rescue breathing rate metronome to aid proper ventilation technique Solutions: 1) Use a mass-flow sensor (AWM720P1, Honeywell) which measures an airflow between 0 and 3.3 L/s 2) Use a microcontroller (PIC18F2321, Microchip Technology) with 512 bytes RAM, 8 kbytes ROM, and a 40 MHz oscillator 3) Use a 3-digit LED display (LDT-C514RI, Lumex) to display volumetric readings 4) Incorporate a thermistor (MCP9700A, Microchip Technology) to measure ambient air temperature 5) Independently sample the battery voltages and display low battery voltages with LEDs 6) Include an independent timing program to control an LED Results A prototype of the Volumetric Airflow Gauge has been developed and constructed (Figure 2 for circuit; Figure 3 for casing). Initial battery-life tests indicated that the use of one 9V battery permitted a circuit life of 10 minutes, while the use of two 9V batteries increased the circuit life to 120 minutes. Discussion A prototype of the Volumetric Airflow Gauge has been successfully developed and constructed. Upon successful completion of the accuracy verification tests, the volumetric airflow gauge will be a proven, practical device that will provide the user with an accurate display of the volume of air introduced to the patient during resuscitation. An accuracy of +/- 50 mL will help minimize the potential for over/under inflation of patients’ airways during manual resuscitation with a BVM. In addition, the simple design of the device allows rapid user comprehension and ease of use. Further validation of the device will be performed by specialists in the Emergency Medicine field. These voluntary specialists will have an opportunity to test the device and provide feedback based on their observations, thus providing additional confirmation of the benefits of the device. Acknowledgments The authors thank Dr. Hal Wrigley, Dr. Linda Baker, the BioEngineering Department, Guy Guimond, and Eric Reiss for their generosity and support. Following completion of circuit assembly (Figure 2), a battery-life test was performed to determine the functional device time before battery warnings were indicated. A test was performed that powered the entire circuit from one battery, while another test was performed that used two batteries: one powering the airflow sensor and one powering the remaining components. Additionally, accuracy tests are planned to compare the volume measured by our device with the volume measured by a human simulator. The difference in volume will undergo statistical testing (i.e. a t-test) to determine the device error. Casing Design Objectives: 1) Interface the casing with existing BVM devices 2) Eliminate air leaks from the flow path 3) House and protect the circuitry from damaging environments and treatments (e.g. rain & device dropping) 4) Minimize device weight Solutions: 1) Input/output ports were designed to fit existing BVM hardware 2) The mass-flow sensor input/output ports were snugly fit into the input/output ports of the casing, and reinforced with rubber gaskets 3) A robust casing was designed to snugly fit the circuitry, while rubber gaskets were added between joints to repel water 4) The prototype was first developed in SolidWorks, where the casing mass was determined and altered through continual redesign Abstract Individuals suffering from cardiopulmonary failure and other types of respiratory distress are commonly treated with a manual resuscitation device in order to initiate breathing. In many instances, excessive or insufficient air volume delivery occurs as a result of the user incorrectly estimating the amount of air administered to the patient. As a result, side-effects including lung tissue damage, gastric distension, and regurgitation have been observed. A volumetric airflow gauge was developed that provides the user with an accurate display of the volume introduced to the patients’ airway with each inflation/deflation cycle of the resuscitator device. The gauge is comprised of an electric circuit board that directly measures the airflow volume powered through the use of two external 9V batteries. A non-reactive plastic was used to construct the housing for the electrical components, permitting the device to be incorporated with relative ease into most standard manual resuscitators. The device will provide a cost-effective method for the user to accurately determine and control the amount of air he/she is administering to the traumatized patient. Figure 2. Completed circuitry of the Volumetric Airflow Gauge. Front: Numerical volumetric display and LED indicators; Back: Mass airflow sensor; Top left: Thermistor Figure 3. SolidWorks model of the Volumetric Airflow Gauge casing Left: Battery compartment and door; Center: Void for the completed circuit; Right: Cap to enclose circuit and direct flow through airflow sensor Figure 1. Volumetric Airflow Gauge circuit schematic.