Dynamic Light Scattering

Slides:



Advertisements
Similar presentations
Viscosity of Dilute Polymer Solutions
Advertisements

The Refractive Index of a Solid An unusual application of spectroscopy.
Introduction to Light Scattering A bulk analytical technique
Dynamic Light Scattering Theory Simplified theoretical background Issues Problems faced during experiments Soln Suggested solutions S. Ramanathan, Dept.
Seminar PCF “Lightscattering”. 1. Light Scattering – Theoretical Background 1.1. Introduction Light-wave interacts with the charges constituting a given.
The Asymptotic Ray Theory
Lecture 17. Light Scattering/Viscometry. What is light scattering? In the lab…
Introduction to DYNAMIC LIGHT SCATTERING (DLS) Christer Svanberg or PHOTON CORRELATION SPECTROSCOPY (PCS)
The Wave Nature of Light
CHEMISTRY ANALYTICAL CHEMISTRY Fall
BIOP – Center for Biomedical Optics and New Laser Systems Light scattering from a single particle Peter E. Andersen Optics and Fluid Dynamics Dept. Risø.
Molecular Fluorescence Spectroscopy
The use of light scattering in characterizing lignin.
Optical Tweezers F scatt F grad 1. Velocity autocorrelation function from the Langevin model kinetic property property of equilibrium fluctuations For.
CHEM Lecture #9 Calculating Time-dependent Properties June 28, 2001 MM 1 st Ed. Chapter MM 2 nd Ed. Chapter [ 1 ]
Basic Questions Regarding All Analytical & Instrumental Methods (p 17-18) What accuracy and precision are required? How much sample do I have available,
December 15, 2002Proterion Corporation. ©1 DynaPro Data Interpretation Guide Understanding Results Obtained from the DynaPro Light Scattering Instrument.
Nanoparticles Characterization: Measurement of the particles size by the PCS technique MSc. Priscyla D. Marcato Dr. Nelson Durán.
Atomic Absorption Spectroscopy (AAS)
Fiber-Optic Communications James N. Downing. Chapter 2 Principles of Optics.
Fluctuations and Brownian Motion 2  fluorescent spheres in water (left) and DNA solution (right) (Movie Courtesy Professor Eric Weeks, Emory University:
The Electromagnetic Spectrum
Lecture 3 INFRARED SPECTROMETRY
Chapter 5 Signals and Noise  Signal carries information about the analyte that is of interest to us.  Noise is made up of extraneous information that.
Atomic Absorption Spectroscopy
1 L U N D U N I V E R S I T Y Methods to determine particle properties Chapter 7.
UGC-DAE Consortium for Scientific Research, Mumbai Light Scattering studies on Colloids & Gels Goutam Ghosh.
Unit 2, Part 3: Characterizing Nanostructure Size Dr. Brian Grady-Lecturer
Chemometrics Method comparison
Chapter 5ELE Adaptive Signal Processing 1 Least Mean-Square Adaptive Filtering.
Chapter 6 Random Error The Nature of Random Errors
Created with MindGenius Business 2005® Performance parameters (Advanced) Theoretical Plate Model Performance parameters (Advanced) Theoretical Plate Model.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Dr. Richard Young Optronic Laboratories, Inc..  Uncertainty budgets are a growing requirement of measurements.  Multiple measurements are generally.
Static & Dynamic Light Scattering First quantitative experiments in 1869 by Tyndall (scattering of small particles in the air – Tyndall effect) 1871 –
EM propagation paths 1/17/12. Introduction Motivation: For all remote sensing instruments, an understanding of propagation is necessary to properly interpret.
02/25/05© 2005 University of Wisconsin Last Time Meshing Volume Scattering Radiometry (Adsorption and Emission)
INTRODUCTION TO ANALYTICAL CHEMISTRY ERT 207 ANALYTICAL CHEMISTRY SEMESTER 1, ACADEMIC SESSION 2015/16.
RamanRaman. Scattering Tyndall scattering – if small particles are present During Rayleigh scattering (interaction of light with relatively small molecules)
Instrument Components Signal Generator (Energy Source) Analytical Signal Transducer Signal Processor Display Can you identify these components in the following.
Optical methods for in-situ particle sizing
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
 a mathematical procedure developed by a French mathematician by the name of Fourier  converts complex waveforms into a combination of sine waves, which.
Sedimentation.
Sedimentation of a polydisperse non- Brownian suspension Krzysztof Sadlej IFT UW IPPT PAN, May 16 th 2007.
FIG. 5.1 Multiple scattering is viewed as a random walk of the photon in diffusing wave spectroscopy (DWS)
Congresso del Dipartimento di Fisica Highlights in Physics –14 October 2005, Dipartimento di Fisica, Università di Milano An application of the.
1 UV-Vis Absorption Spectroscopy Lecture Measurement of Transmittance and Absorbance: The power of the beam transmitted by the analyte solution.
LEAST MEAN-SQUARE (LMS) ADAPTIVE FILTERING. Steepest Descent The update rule for SD is where or SD is a deterministic algorithm, in the sense that p and.
Pursuing the initial stages of crystal growth using dynamic light scattering (DLS) and fluorescence correlation spectroscopy (FCS) Takashi Sugiyama Miyasaka.
CALCULATIONS IN NANOTECHNOLOGY
Background Subtraction and Likelihood Method of Analysis: First Attempt Jose Benitez 6/26/2006.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
1.1 What’s electromagnetic radiation
Theory of dilute electrolyte solutions and ionized gases
Kinetic Properties (see Chapter 2 in Shaw, pp ) Sedimentation and Creaming: Stokes’ Law Brownian Motion and Diffusion Osmotic Pressure Next lecture:
Milling II Dr. Myasr Alkotaji.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Saturation Roi Levy. Motivation To show the deference between linear and non linear spectroscopy To understand how saturation spectroscopy is been applied.
Static Light Scattering Part 2: Solute characteristics
786 Static Light Scattering Part 1: Aggregate Structure & Internal Dynamics.
786 Data Analysis Options.
Suspended Nanomaterials
The Refractive Index of a Solid
Really Basic Optics Instrument Sample Sample Prep Instrument Out put
Light scattering method Introduction: The illumination of dust particles is an illustration of light scattering, not of reflection. Reflection is the deviation.
Optical Spectroscopy: UV/Vis
Particle Size Analysis
8.8 Properties of colloids
Dynamic Light Scattering. Introduction In 1869 J.Tyndall performed the first experimental studies on light scattering from aerosols. He explained the.
Presentation transcript:

Dynamic Light Scattering ZetaPALS w/ 90Plus particle size analyzer Also equipped w/ BI-FOQELS & Otsuka DLS-700 (Rm CCR230)

Dynamic Light Scattering (DLS) Photon Correlation Spectroscopy (PCS) Quasi-Elastic Light Scattering (QELS) Measure Brownian motion by … Collect scattered light from suspended particles to … Obtain diffusion rate to … Calculate particle size

Brownian motion Velocity of the Brownian motion is defined by the Translational Diffusion Coefficient (D) Brownian motion is indirectly proportional to size Larger particles diffuse slower than smaller particles Temperature and viscosity must be known Temperature stability is necessary Convection currents induce particle movement that interferes with size determination Temperature is proportional to diffusion rate Increasing temperature increases Brownian motion

Brownian motion Random movement of particles due to bombardment of solvent molecules Solvent frequency Gas frequency

Stokes-Einstein Equation dH = hydrodynamic diameter (m) k = Boltzmann constant (J/K=kg·m2/s2·K) T = temperature (K) η = solvent viscosity (kg/m·s) D = diffusion coefficient (m2/s)

Hydrodynamic diameter Particle diameter Hydrodynamic diameter The diameter measured by DLS correlates to the effective particle movement within a liquid Particle diameter + electrical double layer Affected by surface bound species which slows diffusion Double layer is extended in a low ionic strength liquid (DI water) so the diameter appears larger

Nonspherical particles = Rapid Equivalent sphere Slow Hydrodynamic diameter is calculated based on the equivalent sphere with the same diffusion coefficient

Experimental DLS Measure the Brownian motion of particles and calculate size DLS measures the intensity fluctuations of scattered light arising from Brownian motion How do these fluctuations in scattered light intensity arise?

What causes light scattering from (small) particles? Explained by JW Strutt (Lord Rayleigh) Electromagnetic wave (light) induces oscillations of electrons in a particle This interaction causes a deviation in the light path through an angle calculated using vector analysis Scattering coefficient varies inversely with the fourth power of the wavelength Incident photon induces an oscillating dipole in the electron cloud. As the dipole changes, energy is radiated or scattered in all directions Really based upon the Tyndall effect Differs from Mie theory in particle size

Interaction of light with matter Rayleigh approximation For small particles (d ≤ λ/10), scattering is isotropic Rayleigh approximation tells us that I α d6 I α 1/λ4 where I = intensity of scattered light d = particle diameter λ = laser wavelength

Mie scattering from large particles Used for particles where d ~ λ0 Complete analytical solution of Maxwell’s equations for scattering of electromagnetic radiation from spherical particles Assumes homogeneous, isotropic and optically linear material Stratton, A. Electromagnetic theory, McGraw-Hill, New York (1941) www.lightscattering.de/MieCalc

Brownian motion and scattering Constructive interference Destructive interference

Brownian motion and scattering Multiple particles

Instrument layout

Intensity fluctuations Apply the autocorrelation function to determine diffusion coefficient Large particles – smooth curve Small particles – noisy curve

Determining particle size Determine autocorrelation function Fit measured function to G(τ) to calculate Γ Calculate D, given n*, θ, and Γ Calculate dH, given T* and η* *User defined values.

How a correlator works Small time increments Random motion of small particles in a liquid gives rise to fluctuations in the time intensity of the scattered light Fluctuating signal is processed by forming the autocorrelation function Calculates diffusion

How a correlator works Large particles – the signal will be changing slowly and the correlation will persist for a long time Small, rapidly moving particles – the correlation will disappear quickly

The correlation function For monodisperse particles the correlation function is Where A= baseline of the correlation function B=intercept of the correlation function Γ =Dq2 D=translational diffusion coefficient q=(4πn/λ0)sin(θ/2) n=refractive index of solution λ0=wavelength of laser θ=scattering angle

The correlation function For polydisperse particles the correlation function becomes where g1(τ) is the sum of all exponential decays contained in the correlation function

Broad particle size distribution Correlation function becomes nontrivial Measurement noise, baseline drifts, and dust make the function difficult to solve accurately Cumulants analysis Convert exponential to Taylor series First two cumulants are used to describe data Γ = Dq2 μ2 = (D2*-D*2)q4 Polydispersity = μ2/ Γ2

Cumulants analysis The decay in the correlation function is exponential Simplest way to obtain size is to use cumulants analysis1 A 3rd order fit to a semi-log plot of the correlation function If the distribution is polydisperse, the semi-log plot will be curved Fit error of less than 0.005 is good. 1ISO 13321:1996 Particle size analysis -- Photon correlation spectroscopy

Cumulants analysis Third order fit to correlation function b = z-average diffusion coefficient 2c/b2 = polydispersity index This method only calculates a mean and width Intensity mean size Only good for narrow, monomodal samples Use NNLS for multimodal samples

Cumulants analysis

Polydispersity index 0 to 0.05 – only normally encountered w/ latex standards or particles made to be monodisperse 0.05 to 0.08 – nearly monodisperse sample 0.08 to 0.7 – This is a mid-range polydispersity >0.7 – Very polydisperse. Care should be taken in interpreting results as the sample may not be suitable for the technique (e.g., a sedimenting high size tail may be present)

Non-Negatively constrained Least Squares (NNLS) algorithm Used for Multimodal size distribution (MSD) Only positive contributions to the intensity-weighted distribution are allowed Ratio between any two successive diameters is constant Least squares criterion for judging each criterion is used Iteration terminates on its own

Correlation function Correlograms Correlograms show the correlation data providing information about the sample The shape of the curve provides clues related to sample quality Decay is a function of the particle diffusion coefficient (D) Stokes-Einstein relates D to dH z-average diameter is obtained from an exponential fit Distributions are obtained from multi-exponential fitting algorithms Noisy data can result from Low count rate Sample instability Vibration or interference from external source

Correlation function Correlograms What does the intercept tell us?

Data interpretation Correlograms Very small particles Medium range polydispersity No large particles/aggregrates present (flat baseline)

Data interpretation Correlograms Large particles Medium range polydispersity Presence of large particles/agglomerates (noisy baseline)

Data interpretation Correlograms Very large particles High polydispersity Presence of large particles/agglomerates (noisy baseline)

Upper size limit of DLS DLS will have an upper limit wrt size and density When particle motion is not random (sedimentation or creaming), DLS is not the correct technique to use Upper limit is set by the onset of sedimentation Upper size limit is therefore sample dependent No advantage in suspending particles in a more viscous medium to prevent sedimentation because Brownian motion will be slowed down to the same extent making measurement time longer

Upper size limit of DLS Need to consider the number of particles in the detection volume Amount of scattered light from large particles is sufficient to make successful measurements, but … Number of particles in scattering volume may be too low Number fluctuations – severe fluctuations of the number of particles in a time step can lead to problems defining the baseline of the correlation function Increase particle concentration, but not too high or multiple scattering events might arise

Detection volume Detector Laser

Lower particle size limit of DLS Lower size limit depends on Sample concentration Refractive index of sample compared to diluent Laser power and wavelength Detector sensitivity Optical configuration of instrument Lower limit is typically ~ 2 nm

Sample preparation Measurements can be made on any sample in which the particles are mobile Each sample material has an optimal concentration for DLS analysis Low concentration → not enough scattering High concentration → multiple scattering events affect particle size

Sample preparation Upper limit governed by onset of particle/particle interactions Affects diffusion speed Affects apparent size Multiple scattering events and particle/particle interactions must be considered Determining the correct particle concentration may require several measurements at different concentrations

Sample preparation An important factor determining the maximum concentration for accurate measurements is the particle size

Sample concentration Small particles For particle sizes <10 nm, one must determine the minimum concentration to generate enough scattered light Particles should generate ~ 10 kcps (count rate) in excess of the scattering from the solvent Maximum concentration determined by the physical properties of the particles Avoid particle/particle interactions Should be at least 1000 particles in the scattering volume

Sample preparation When possible, perform DLS on as prepared sample Dilute aqueous or organic suspensions Alcohol and aggressive solvents require a glass/quartz cell 0.0001 to 1%(v/v) Dilution media (1) should be the same (or as close as possible) as the synthesis media, (2) HPLC grade and (3) filtered before use Chemical equilibrium will be established if diluent is taken from the original sample Suspension should be sonicated prior to analysis

Checking instrument operation DLS instruments are not calibrated Measurement based on first principles Verification of accuracy can be checked using standards Duke Scientific (based on TEM) Polysciences

Count rate and z-average diameter Repeatability Perform at least 3 repeat measurements on the same sample Count rates should fall within a few percent of one another z-average diameter should also be with 1-2% of one another

Count rate Repeatability problems Count rate DECREASES with successive measurements Particle sedimentation Particle creaming Particle dissolution or breaking up Resolution Prepare a better, stabilized dispersion Get rid of large particles Coulter

Count rate Repeatability problems Count rate is RANDOM with successive measurements Dispersion instability Sample contains large particles Bubbles Resolution Prepare a better, stabilized dispersion Remove large particles De-gas sample

Z-average diameter Repeatability problems Size DECREASES with successive measurements Temperature not stable Sample unstable Resolution Allow plenty of time for temperature equilibration Prepare a better, stabilized dispersion

Repeatability of size distributions The sized distributions are derived from a NNLS analysis and should be checked for repeatability as well If distributions are not repeatable, repeat measurements with longer measurement duration

References http://www.bic.com/90Plus.html http://www.brainshark.com/brainshark/vu/view.asp?text=M913802&pi=62212 http://www.malvern.co.uk/malvern/ondemand.nsf/frmondemandview http://www.brainshark.com/brainshark/vu/view.asp?text=M913802&pi=96389 http://www.brainshark.com/brainshark/vu/view.asp?text=M913802&pi=73504 http://physics.ucsd.edu/neurophysics/courses/physics_173_273/dynamic_light_scattering_03.pdf http://www.brookhaven.co.uk/dynamic-light-scattering.html Dynamic Light Scattering: With Applications to Chemistry, Biology, and Physics, Bruce J. Berne and Robert Pecora, DOVER PUBLICATIONS, INC. Mineola. New York Scattering of Light & Other Electromagnetic Radiation, Milton Kerker, Academic Press (1969) Additional references that Riman mentioned

Evaluating the correlation function If the intensity distribution is a fairly smooth peak, there is little point in conversion to a volume distribution using Mie theory However, if the intensity plot shows a substantial tail or more than one peak, then a volume distribution will give a more realistic view of the importance of the tail or second peak Number distributions are of little use because small error in data acquisition can lead to huge error in the distribution by number and are not displayed

Correlogram from a sample of small particles

Correlogram from a sample of large particles

Extra Time-dependent fluctuations in the scattered intensity due to Brownian motion Constructive and destructive interference of light Decay times of fluctuations related to the diffusion constants --- particle size Fluctuations determined in the time domain by a correlator Correlation – average of products of two quantities Delay times chosen to be much smaller than the time required for a particle to relax back to average scattering