Joseph S. Park, M.D. Silvia Blemker, PhD. University of Virginia Orthopaedic Surgery Clinical Problem: Fixation of FDL Tendon to Navicular Cut posterior.

Slides:



Advertisements
Similar presentations
R1.3 RESP1.3 RESPONSE OF CIVIL ENGIONEEONSE OF CIVIL ENGINEERING PROJECT 1.3 RESPONSE OF CIVIL ENGINEERING PROJECT 1.3 RESPONSE OF CIVIL ENGINEERING PROJECT.
Advertisements

In-Class Case Study: Determining the Mechanical Properties of Bone Using State-of-the-art Mechanical Testing System (MTS Bionix) Prepared by Prof. Deepak.
Tendon and Ligament. Roles of Ligaments and Joint Capsules u Assist in Stabilization of Joint u Restrict Movement u Prevent Excessive Motion.
A simple solution to a painful problem Warning: the following presentation contains unpleasant photographs.
Testing Your Device: What the FDA Looks For
EFFECTS OF HAMSTRING TENDON VS PATELLAR TENDON GRAFTS ON KNEE STABILITY FOLLOWING ACL RECONSTRUCTION Adrien Brudvig and Sha’ Howard ESS 265 A Research.
Coen A. Wijdicks, Ph.D. Chief Operating Officer Director of the Department of BioMedical Engineering Senior Staff Scientist Steadman.
Hypothesis Figure 1: Proximal end of human humerus bone fitted with the 3.5mm Proximal Humerus Plate before testing. Figure 2: Proximal end of human humerus.
Francine Goulet, Ph.D., pht Nanomedical Biological Device in Development for Torn ACL Replacement.
Introduction – Concept of Stress
Department of Bioengineering Instron Uniaxial Tensile Testing: Mechanical Failure Properties of Suturing and Steri-Strips GROUP #5 Seungyon Kim – Background.
In-vivo Evaluation of Round Breast Implant in a Stand-Up MRI
Introduction – Concept of Stress
Principles and Applied Anatomy for Arthroscopic Anterior and Posterior Instability Surgery of the Shoulder Edward Tillett, M.D. Department of Orthopedic.
PTP 521 Musculoskeletal Disorders and Dysfunctions
Biocompatibility of Titanium Implants in Beagle Dogs Chuck Rosenwasser Mentors: Frank Raia & Mel Rosenwasser Columbia Presbyterian Medical Center.
Department of Bioengineering Modeling of Wound Closures Under Uniaxial Tensile Loading 101A3 Tefesehet Mesfin – Background & Hypothesis Ryan Stuckert –
Distal Biceps Injury: Surgery and Rehabilitation Caroline Chebli, MD Kennedy-White Orthopaedic Center.
Ligaments and Tendons Part 3 David Flanigan, MD Assistant Professor of Clinical Orthopaedics Team Physician The OSU Sports Medicine Center.
Biomechanics and biology: bridging the gap Sam Evans School of Engineering
The design of an in-vivo rotator cuff measuring tool PROJECT PROPOSAL Kathleen Bieryla, Katie Fronczak, Martha Loehr, Eric Rainis University of Pittsburgh.
University of Pittsburgh Vascular Bioengineering Laboratory Departments of Surgery and Bioengineering and the McGowan Institute for Regenerative Medicine.
Lessons from Retrieval Analysis of Joint Replacements Tim Wright, PhD 3 rd ISOC Meeting - Bologna.
Characterization of porous scaffold materials for bone tissue engineering - Saartje Impens - Micro-CT symposium 31/05/07.
May 2013 NDCM-XIII Le Mans1 Materials Evaluation.
Bryant Roberts Supervisors: Karen Reynolds, Egon Perilli.
MECHANICS OF MATERIALS Third Edition Ferdinand P. Beer E. Russell Johnston, Jr. John T. DeWolf Lecture Notes: S.A.A.Oloomi CHAPTER © 2006 Islamic Azad.
Load-to-Failure, Contact Area and Contact Pressure of Three Rotator Cuff Repair Methods: A Comparative Biomechanical Analysis Josianne Lépine and Frédéric.
Hemiarthroplasty for Fracture Design Rationale and Surgical Technique Reza Omid, M.D. Assistant Professor Orthopaedic Surgery Shoulder & Elbow Reconstruction.
Continuous Loop Double Endobutton Reconstruction for AC Joint Dislocation Steven Struhl, MD 1, Theodore Wolfson, MD 1 1 Department of Orthopaedic Surgery,
Introduction – Concept of Stress
Overview of Mechanical Engineering for Non-MEs Part 2: Mechanics of Materials 6 Introduction – Concept of Stress.
Reconstruction of Massive Rotator Cuff Tear Using Embroidered Polyester Cuff Reinforcement Nottingham Shoulder and Elbow Unit I-H Jeon, WA Wallace, L Neumann,
Statistical Analysis of the Tensile Properties of Various Polymers Processed through 3D Printing Introduction Additive Manufacturing is a new processing.
Probabilistic Analysis: Applications to Biomechanics Students: Saikat Pal, Jason Halloran, Mark Baldwin, Josh Stowe, Aaron Fields, Shounak Mitra Collaborators:
Biomechanical comparative study of the JuggerKnot™ soft anchor technique with other common mallet finger fracture fixation techniques Jason Pui Yin Cheung,
Effect of Short-Duration Low-Magnitude Cyclic Loading Versus Immobilization on Tendon-Bone Healing After ACL Reconstruction in a Rat Model by Robert H.
The design of an in-vivo rotator cuff measuring tool PROJECT UPDATE Kathleen Bieryla, Katie Fronczak, Martha Loehr, Eric Rainis University of Pittsburgh.
Effect of Early and Delayed Mechanical Loading on Tendon-to-Bone Healing After Anterior Cruciate Ligament Reconstruction by Asheesh Bedi, David Kovacevic,
Surgical and Laboratory Instruments and Devices. Ward Engineering is a provider of quality medical device design, development, and manufacturing services.
SHOULDER: Dislocation / Instability John W. Gibbs, DO Orthopaedic Surgeon Rochester Regional Health Orthopaedics at Red Creek.
ADDITIVE MANUFACTURING PROJECT CLUSTER MEETING AM for Polymers, ceramics and biomaterials Fundació CIM C/Llorens i Artigas, 12 Parc Tecnològic de Barcelona.
Objectives Biomechanical testing of bone. Case study on axial testing of bovine cortical bone on MTS Mechanical properties of bone and their use.
Olson EM, Sturm PF, Jain VV, Schultz LR, Glos DL, Bylski-Austrow DI
Implant: مادة سنية / د . زينة ثاني اسنان موصل 12 / 4 / 2016
Introduction – Concept of Stress
Concept of Stress.
Effect of Tunnel Position in Graft Failure with Single-Bundle Anterior Cruciate Ligament Reconstruction 1Soheil Sabzevari, MD; 1Amir Ata Rahnemai-azar,
Nicholas R. Pagani, B.S., Antonio Cusano, B.S., Xinning Li, M.D. 
Hélder Pereira, M. D. , Gwen Vuurberg, Nuno Gomes, M. D
ACL INTERFERENCE SCREW
Combined Reconstruction of the Medial Collateral Ligament and Anterior Cruciate Ligament Using Ipsilateral Quadriceps Tendon–Bone and Bone–Patellar Tendon–Bone.
Tutorial in Mechanical Properties
Suture Anchor Repair for a Medial Meniscus Posterior Root Tear Combined With Arthroscopic Meniscal Centralization and Open Wedge High Tibial Osteotomy 
Subpectoral Biceps Tenodesis Using an Expanding PEEK Device
George Sanchez, B. S. , Marcio B. Ferrari, M. D. , Anthony Sanchez, B
Philippe Colombet, M.D., Nicolas Bouguennec, M.D. 
Distal Triceps Knotless Anatomic Footprint Repair: A New Technique
Surgical Technique 5.5Anchor
Knotless Tissue Repair and Attachment Devices
Patrick J. Denard, M.D., Stephen S. Burkhart, M.D. 
A Technique of Superficial Medial Collateral Ligament Reconstruction Using an Adjustable-Loop Suspensory Fixation Device  Shaneel Deo, B.H.B.(Hons), M.B.Ch.B.,
Davide Edoardo Bonasia, M. D. , Federico Dettoni, M. D
Concept of Stress.
Equine Lung Function Testing
Open Gluteus Medius and Minimus Repair With Double-Row Technique and Bioinductive Implant Augmentation  Caleb M. Gulledge, B.S., Eric C. Makhni, M.D.,
Davide Edoardo Bonasia, M. D. , Federico Dettoni, M. D
The Lancet Digital Health
Combined Reconstruction of the Medial Collateral Ligament and Anterior Cruciate Ligament Using Ipsilateral Quadriceps Tendon–Bone and Bone–Patellar Tendon–Bone.
Presentation transcript:

Joseph S. Park, M.D. Silvia Blemker, PhD

University of Virginia Orthopaedic Surgery Clinical Problem: Fixation of FDL Tendon to Navicular Cut posterior tibialis tendon Harvested FDL tendon Navicular bone Bone tunnel FDL tendon

University of Virginia Orthopaedic Surgery ~33-50% loss in moment arm ~33-50% loss in moment arm Consequence of shifting the effective insertion is loss of moment arm mm AP

University of Virginia Orthopaedic Surgery Aim 1 is to test strength of compression with: Aim 1 is to test strength of compression with: Suture anchor alone Suture anchor alone Suture anchor plus suture button prototype Suture anchor plus suture button prototype Suture anchor plus porous metal spiked button prototype Suture anchor plus porous metal spiked button prototype In rabbit achilles tendons and bone substitute Aim 2 is to characterize the biologic healing of the tendon-bone interface in surgically-repaired rabbit Achilles tendons Aim 2 is to characterize the biologic healing of the tendon-bone interface in surgically-repaired rabbit Achilles tendons -2a: characterize with H&E staining (1/2 animals) -2b: characterize healing tendon with MRI -2c: perform biomechanical testing of healed tendon Research Aims

University of Virginia Orthopaedic Surgery Study Funded by the Wallace H. Coulter Foundation Translational Research Award ($100,000) Study Funded by the Wallace H. Coulter Foundation Translational Research Award ($100,000) Funding

University of Virginia Orthopaedic Surgery ● Repair Method for Small Bones: Suture anchor ● Problems: Problem: Imperfect Tendon Repair Risk of Reinjury Immobilization Scar Tissue

University of Virginia Orthopaedic Surgery Solution Goal Show that the suture button is an improvement to the suture anchor technique

University of Virginia Orthopaedic Surgery ● 3 Tests 1. Pressure Film 2. Cyclic Loading 3. Tensile Load-to-Failure Methods ● Validation of Hypothesis 1. Increased contact area 2. Stronger tendon-bone interface 2 Conditions: Control Device

University of Virginia Orthopaedic Surgery Use Fuji Pressure Film to characterize compressive force applied. Use Fuji Pressure Film to characterize compressive force applied. Button  3.8 x increase area of compression (P <0.002). Button  3.8 x increase area of compression (P <0.002). Contact Area No Button Button

University of Virginia Orthopaedic Surgery New Zealand White rabbit achilles tendons were attached to bone block substitute (Sawbones.com) via Biomet Juggerknot anchors New Zealand White rabbit achilles tendons were attached to bone block substitute (Sawbones.com) via Biomet Juggerknot anchors 25 N of force were applied for 50 cycles (0.5 Hz) 25 N of force were applied for 50 cycles (0.5 Hz) Control: 2.24 mm liftoff Control: 2.24 mm liftoff Device: 0.19 mm liftoff (0.99 mm at 500 cycles) Device: 0.19 mm liftoff (0.99 mm at 500 cycles) Cyclical Loading TABLE 2 Measurement of Liftoff After 50 Cycles Distance From Underside of Tendon to Bone Block, mm Device condition specimens Average2.24 SD0.12 Control condition specimens Average0.19 SD0.09

University of Virginia Orthopaedic Surgery Load to Failure Control Device Insertional footprint

University of Virginia Orthopaedic Surgery Pull to failure tests Pull to failure tests Looked at yield load and ultimate load Looked at yield load and ultimate load Yield load : begins to tear Yield load : begins to tear Ultimate load: complete failure Ultimate load: complete failure Tensile Failure Testing

University of Virginia Orthopaedic Surgery

Yield Load

University of Virginia Orthopaedic Surgery TABLE 3 Results of Load-to-Failure Tensile Test Yield Load, NUltimate Load, N Device condition specimens Average SD Control condition specimens Average SD Yield Load 72% increase in Yield Load with Device Condition

University of Virginia Orthopaedic Surgery Provisional Patent Filed 9/23/14 Provisional Patent Filed 9/23/14 Pursuing partnership for manufacturing of surgical grade buttons (titanium/PEEK). Pursuing partnership for manufacturing of surgical grade buttons (titanium/PEEK). Consideration for materials: titanium may allow for thinner implant for both cleated and spiked versions. (10x stronger versus flexion and 6x stronger versus compression) Consideration for materials: titanium may allow for thinner implant for both cleated and spiked versions. (10x stronger versus flexion and 6x stronger versus compression) Button Optimization: due to fracture of button during initial Instron trials, made holes smaller, centered to increase strength of implant. 3D printed buttons made of Acrylonite Butadiene Styrene (ABS) Button Optimization: due to fracture of button during initial Instron trials, made holes smaller, centered to increase strength of implant. 3D printed buttons made of Acrylonite Butadiene Styrene (ABS) Intellectual Property

University of Virginia Orthopaedic Surgery ACUC Animal Protocol approved for rabbit in-vivo study ACUC Animal Protocol approved for rabbit in-vivo study IRB being written for MRI study for human subjects s/p tendon reattachment with/with-out suture button (Blemker/Nacey/Miller) IRB being written for MRI study for human subjects s/p tendon reattachment with/with-out suture button (Blemker/Nacey/Miller) Intellectual Property-Future Directions

University of Virginia Orthopaedic Surgery Silvia Blemker PhD-Biomedical Engineering Silvia Blemker PhD-Biomedical Engineering Capstone BME Team: Lauren Baetsen, Cate Markert, John McNulty, Audra Sawyer Capstone BME Team: Lauren Baetsen, Cate Markert, John McNulty, Audra Sawyer Chris Li, PhD-Mechanical Engineering Chris Li, PhD-Mechanical Engineering Future Studies- Future Studies- Master’s Student? Master’s Student? Hilary Bart-Smith PhD? Hilary Bart-Smith PhD? Stephen Brockmeier MD? Stephen Brockmeier MD? Aim 2: In Vivo Rabbit Achilles Study Aim 2: In Vivo Rabbit Achilles Study MRI evaluation MRI evaluation Histology Histology Mechanical Testing Mechanical Testing Research Team

University of Virginia Orthopaedic Surgery Capstone Team

University of Virginia Orthopaedic Surgery Thank You!