Platzhalter Bild Vacuum Transfer System for loading the Sartorius Prototype Mass Comparator CCL1007 Thomas Fehling, NCSLI-Conference, Washington D.C.,

Slides:



Advertisements
Similar presentations
Suspension Systems - 1 Topics covered in this presentation:
Advertisements

Load Cell &DP Cell 2007-CHEM-17.
Mass Metrology, April 2003Mass Metrology - Susceptometer, June 2007 Sartorius Susceptometer - for Precise Measurement of: Susceptibility and Magnetization.
1 Ann Van Lysebetten CO 2 cooling experience in the LHCb Vertex Locator Vertex 2007 Lake Placid 24/09/2007.
Purpose Body Making module is designed for bending the laminated foil film in the shape of a tube, for welding the side seam and for cutting bodies with.
HYDRA-PNEUMATIC HAMMERS. Hydra-Pneumatic Hammer 1 Basic working principles of the Hydra- Pneumatic Hammer 2 Technical Characteristics of the Hydra-Pneumatic.
Mate Grinder MATE European Dealer Meeting Advantages of Automatic Controlled Punch and Die Grinding More regrinds, accurate material removal Protect.
Sputter Stand Safety Specifics Electrical Hazards High Voltage : Electrical power is required for the high voltage supply, gauging, system controller and.
Objective of the session.
Bellow valve (trap&pump) Inside glove box. (Note: Ar glove box is not necessary, if you work with single crystalline organic materials like rubrene that.
31/03/11FV 1 CEDAR from flammable gas safety point of view.
Overview of Vacuum Systems Tejas Deshpande 24 July, 2014.
Experiment 8 : Minor Losses
Components for the low- maintenance switch Components for the low maintenance track Schwihag RBH system.
Wel Handy Mini For horizontal and vertical (down) fillet welding operations.
Heinz Grote1 Presentation to NSCX WENDELSTEIN 7-X Assembly Max-Planck- Institut für Plasmaphysik KKS-Nr.: 1-AD Dok-Kennz.: -Txxxx.0 Heinz Grote October.
Progress and Plan for Superconducting RF Cavity RF Group.
NITRO SHOCK ABSORBERS.
EASYCLEAN EASYCLEAN Available in 2 sizes Top Cover Safety Function Automatic Start/Stop Cleans and Dries the plate 2 Brushes Water and Gum Recirculation.
AW Rayment & TW Clyne Department of Materials Science & Metallurgy University of Cambridge, UK Design and Commissioning of a Chamber for Controlled Atmosphere.
MICE RFCC Module Update Allan DeMello Lawrence Berkeley National Lab MICE CM26 at Riverside California March 26, 2010.
Unit 206: Domestic hot water systems
Installation. Indoor Unit Installation Typical Installation.
MilkTech International Web-assisted Training in Milk Harvesting An educational initiative by: University of Wisconsin - Madison (USA) Milking Research.
Higher Physics – Unit – Density and Pressure.
Assisted Bench Press Machine JARRED MORALES JUNKUN MA SPRING 2014 SOUTHEASTERN LOUISIANA UNIVERSITY.
Engineer Training Mechanical Overview. Engineer Training Confidential 2 XL1500 is both Roll-to-Roll and Roll-to-Sheet Printer MachineXL1500-2mXL1500-3mXL1500-5m.
Introduction to Operation of the XL- 30 Scanning Electron Microscope Tutorial # 2 Introduction to Operation and Imaging.
Hydronic Mechanical Controls
ZQNA Electrostatic Quadrupoles for ELENA Transfer Lines 1.Conceptual design 2.Performance 3.Engineering details 4.Interfaces 5.Production planning D. Barna,
Fluid Statics.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
1 Cryostat assembly, integration and commissioning procedures M.Olcese Version: 07 May 2008.
HVAC523 Circulator Pumps.
GERDA collaborationmeeting, Ringberg castle Béla MajorovitsTG5 Review: Infrastructure on top of the tank1.
VC Training Table Setup and Floating Agenda General –Air Supply Requirements Assembly –Assembling the System –Leveling the Table –Isolating.
Majorana collaboration meeting, Seattle, Aug.7 - Aug. 9 Béla MajorovitsGERDA detector mounting 1 GERDA Detector Mounting The Detector Holders Detector.
1. Presentation Gorosabel Group is a modern and innovative business group with a steady expansion path and has an experience of over 50 years in business;
Standard Weights and Classes of Balances
Gusev Konstantin, Kurchatov Institute / JINR , Gerda meeting Some technical aspects of testing and adaptation of existing detectors.
A PRESENTATION on “ SUSPENSION SYSTEM ”
Vacuum system.
CLASSE prototype: mechanical concepts G. De Michele, EPFL-PSI-CERN on behalf of CERN team SLAC, 16 th April, 2012.
Ch Ch.15 Term 061. Ch-12  T061  Q16. The volume of a solid Aluminum sphere at the sea level is V = 1.0 m3. This sphere is placed at a depth of.
Polarized GaAs photo cathode development and the preparation of Gatling Gun cathodes at BNL The Single Cathode Activation Chamber.
1m 3 SDHCAL Mechanic Structure M.C Fouz 8/10/2010 The 1m 3 prototype Mechanical Structure is financed by: Spanish HEP National Program by the project FPA
Pressure in a gas Lesson Outcomes: To know and to be able to explain a demonstration that proves that air exerts a pressure. (C/B) Describe the simple.
Introduction to Fluid Mechanics Engineering 1h Prof Bill Easson.
Flex Cam – Training This shows one version of a complete FlexCam system including Power Unit HCP and Compact Cam CC for piercing operation.
M. Gilchriese Module Assembly and Attachment at LBNL M. Gilchriese for F. Goozen April 2000.
RICH1 Gas Enclosure Installation. Experimental Area Meeting at CERN on 21st June 2006 Bill Cameron (Imperial College London) on behalf of the RICH1 team.
Chapter 1.2 Notes Pressure. All matter is made up of atoms and molecules. All matter is made up of atoms and molecules. Matter can exist in four states:
Fluid Mechanics - Hydrostatics AP Physics B. States of Matter Before we begin to understand the nature of a Fluid we must understand the nature of all.
1 Product Presentation January Normal BinROXELL Bin Old feed Normal bin: ‘centerflow’ feed flows first in center  bridging ‘mass flow’ feed.
Presentation Orcon HRC 300 and 400
A WEIGHT EXCHANGE SYSTEM FOR AN ABSOLUTE PRESSURE BALANCE Authors: H. Kajastie, J. Manninen, M. Rantanen, K. Riski and S. Semenoja, Centre for Metrology.
Pacific school of Engineering Sub: I.P.C Topic: Pressure measurement Guided by Piyush modi Mayani Chintak Sudani Dhrutik Bhikadiya.
Platzhalter Bild Design and Performance of a Fully Automatic Robot System for Mass Determination Thomas Fehling, NCSLI–Conference, Orlando/Florida, August.
Air condition installation
Development of Cryo-Module Test Stand (CMTS) for Fermi Lab (R.L.Suthar, Head,CDM, BARC) Cryo-Module Test stand (CMTS) is a very sophisticated equipment.
The HiLumi LHC Design Study is included in the High Luminosity LHC project and is partly funded by the European Commission within the Framework Programme.
Sartorius Volume Comparator VD1005 A new Method for highly accurate Density Determination Benno Gatzemeier, Market Manager Mass Metrology, Sartorius AG.
Two-beam module layout
Product Presentation January 2010.
Physics Support Materials Higher Mechanics and Properties of Matter
INSTALLATION SEQUENCE
Sphere Option for Helical spring CF16 Bellows Adjustment bolts (horizontal plane) CF38.
© 2004 – 2011 PAVAC Industries Inc. All rights reserved
 Define: The stirring heating plate or heated stirring heating plate has been developed to heat and mix fluids contained in laboratory receptacles such.
Suspension Systems - 1 Topics covered in this presentation:
Presentation transcript:

Platzhalter Bild Vacuum Transfer System for loading the Sartorius Prototype Mass Comparator CCL1007 Thomas Fehling, NCSLI-Conference, Washington D.C., August 24, 2011

Platzhalter Bild Contents Introduction Design of VTS Vacuum Transport Container Modes of Operation Loading Procedure Control Software Vacuum Pumping System Conclusion

Page 3 Introduction Two experiments for a new definition of the SI-unit „kg“ based on a natural constant are in process: Avogadro-project -> Watt-balance With the aim to fullfill mass comparisons with a silicon sphere under vacuum conditions Sartorius developed in cooperation with the BIPM/France the so called Prototype Balance CCL1007 -> Introduction at NCSLI in A next step in the Avogadro-project and a challenge for Sartorius is the storage and handling of the silicon sphere under vacuum conditions to avoid any contamination. For this purpose Sartorius developed the Vacuum Transfer System (VTS).

Page 4 Introduction The Vacuum Transfer System was developed in cooperation with competent partners in the field of high accuracy mass determination with the aim to realize a loading procedure of the 1kg-Prototype Mass Comparator CCL1007 under vacuum or neutral gas conditons. Cooperation Agreement with “IPMS of Technical University of Ilmenau“ and “SIOS Messtechnik GmbH”

Page 5 Introduction The Vacuum Transfer System (VTS) is designed for fully automatic loading of weights into the Sartorius Prototype Mass Comparator CCL1007. The system enables the user to transfer weights from air to air/neutral gas, air to vacuum and back, as well as from vacuum to vacuum conditions. Schematic drawing of the VTS in connection with vacuum enclosure of CCL1007 The Vacuum Transfer System (VTS) is directly connected to the mass comparator vacuum chamber via a DN200 high vacuum gate valve.

Page 6 Introduction To connect the VTS to CCL1007 the original quick loading door of the CCL1007 main vacuum chamber as well as the standard air to air loading mechanism have to be dismounted. Air to air standard loading mechanism mounted outside the main chamber of CCL1007 VTS mounted on vacuum enclosure of CCL1007 hier ein Bild vom angekoppelten VTS...??

Page 7 Introduction  The VTS chamber can be evacuated independently from the CCL1007 main chamber if the gate valve is closed.  The gate valve is operated manually according to the load/unload procedure  Inside the VTS chamber a fully automatic transfer system receives the weights and transfers them to the load alternator of the Prototype Mass Comparator CCL1007 Top view of internal transfer system and CCL1007 vacuum enclosure

Page 8 Design of VTS  all components are high vacuum compliant  free of oil  optimized for low magnetic properties  two z-axis manipulators  dovetail guide with spindle on the air side and vacuum bellows  Vacuum chamber offers several ISO-KF vacuum flanges for measuring instruments like vacuum gauges or the connection of a vacuum pump system

Page 9 Design of VTS  horizontal guiding for the feed arm movement is an oil free UHV compliant recirculating ball guide  depending on the mode of operation the weight is placed directly on the feed arm of the transfer system or alternatively a vacuum transport container with the weight inside is placed on a vertical moveable base plate.

Page 10 The Vacuum Transport Container Features of VTC:  The Vacuum Transport Container is designed to load OIML-shaped weights, as well as national prototypes or silicon spheres up to 1kg  storing weights under vacuum or keep them in neutral gas.  the container can be loaded to the VTS through a wide rectangular door and can be opened inside the closed VTS  use under air, vacuum or neutral gas atmosphere by using special vacuum manipulators mounted on the VTS.

Page 11 The Vacuum Transport Container  guided spring mechanism to fix the weight  contact material at the bottom and at the top of the weight is high vacuum compliant PEEK  base plate and upper holder with the spacer can be changed to suit the different shapes and heights

Page 12 The Modes of Operation Cylindrical 1kg test weight standing on feed arm, bell hanging and lifted up, table with VTC base plate fixed moved down to lowest position Loading weights to and unloading weights from the CCL1007 main chamber filled with moist air can be done using the standard air to air loading mechanism as well as with the VTS. opened VTS for loading a weight directly or loading the Vacuum Container

Page 13 The Modes of Operation  Moist air - means ordinary air with water, oxygen and some hydrocarbons contained in air.  Neutral gas - means dry nitrogen, argon or any gas without undesirable contamination under normal or reduced pressure.  Vacuum - means high vacuum between 0.1Pa and Pa. Weight stored in: CCL1007 filled with/condition Moist airNeutral GasVacuum Moist air147 Neutral Gas258 Vacuum369 Operation mode number depending on weighing and storing conditions The VTS has several modes of operation depending on the conditions under which the weight is stored and how the CCL1007 main chamber is filled.

Page 14 The Modes of Operation  The VTS is absolutely essential for loading and unloading weights stored under moist air if the CCL1007 main chamber is operated under neutral gas or evacuated (operation mode numbers 4 and 7)  The use of VTS is absolutely essential for operation mode numbers 5, 6, 8 and 9 (the weights have to be stored in the Vacuum Transport Container VTC) Weight stored in: CCL1007 filled with/condition Moist airNeutral GasVacuum Moist air147 Neutral Gas258 Vacuum369 Operation mode number depending on weighing and storing conditions The loading and unloading procedure varies for all operation modes and is described in detail in the VTS operation manual.

Page 15 The Loading Procedure for example Mode 9: vacuum to vacuum CCL1007 VTS

Page 16 The Control Software  The complete operation of the VTS system is controlled by the software  Gate valve and the vertical guide for lifting the bell and table are manually operated  During the automatic loading procedure the eccentricity of the weight will be adjusted on the X and Y axes by movement of the feed arm and by the rotation of the carousel.  Cylindrical shaped test weights are pre centered using a system with 3 strain gauge sensors.

Page 17 The Vacuum Pumping System  The pumping system for the VTS is completely independent of the pumps for the CCL1007 main chamber.  The pumping system consists of the pre vacuum scroll pump and the turbo molecular pump  The primary pressure of 100Pa necessary for starting the turbo molecular pump is reached after less than 10 minutes. A vacuum of 0.1Pa is normally reached 10 minutes after starting the turbo molecular pump.  There are several valves to control the evacuation process.  It is also possible to connect the Vacuum Transport Container to the pumping system for separate evacuation. separate scroll-pump turbo-molecular pump mounted at VTS

Page 18 Conclusion  The VTS was jointly developed by Sartorius, the Institute of Process Measurement and Sensor Technology at Ilmenau Technical University and SIOS Messtechnik GmbH.  It allows the CCL1007 to run permanently under vacuum or neutral gas conditions avoiding the opening of the quick loading door for changing the test weights.  Furthermore, it is now also possible to keep the test weights outside the CCL1007 under vacuum or neutral gas by using the Vacuum Transport Container.  This container can be opened inside the VTS to keep normal atmosphere away from the test weights.  The VTS will open up many application possibilities for high level mass metrology.  One VTS system is installed at the BIPM/France another one at PTB/Germany.

Platzhalter Bild Thank you for your Interest in Sartorius Weighing Technology Thomas Fehling, NCSLI-Conference, Washington D.C., August 24, 2011