Flow Meters Flow: Volume of a fluid passing certain point over a given time Flow Rate. over a given time Flow Rate. Flow meters:sets used to measure flow.

Slides:



Advertisements
Similar presentations
Carburetion Systems Small Engines.
Advertisements

Safety / Intro The mains supply and batteries are sources of Electrical Energy Electrical Appliances are Energy Changers.
ANESTHETIC MACHINES.
Safety Requirements of the Anesthesia Workstation
Anesthesia Machine Presented by Gil Soto C.R.N.A.
INTERMEDIATE PRESSURE SYSTEM PRESENTED BY: Dr CHITTRA MODERATED BY: Dr JYOTI PATHANIA.
FLOW measurements.
The Poorman’s off Chassis Restoration. Com Copyright 2004 Click your tool bar BACK button to exit How to Navigate.
Aims and Objectives Aim To be able to recognize operation of a carburettor within an internal combustion engine Objectives Be able to describe the operation.
Mechatronics Department Graduation Project II. OutlineIntroduction. Methodology. Mechanical Design. Control Design.
Inhaled Anesthetic Delivery Systems
Regulators and Flowmeters
Thermo-energy audit Services for thermo-energy audit Flow measurement.
Check Valves and Manufacturer-Recommended Leak Test
Electric Charges & Current
Motion of particles trough fluids part 2
Presented by : Dr Rashmi Moderator: Dr Gian Chauhan.
Anesthetic Equipment.
NITRO SHOCK ABSORBERS.
 Understand the components & the operating principles of the anaesthesia machine, namely, gas supply, O 2 safety.
 The annular space. The clearance between the head of the float and the flow tube is known as the annular space.
Fuel Evaporation in Ports of SI Engines P M V Subbarao Professor Mechanical Engineering Department Measure of Useful Fuel …..
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
Lecture 3: Flow, Level, Temperature and Light Measurement
Actuators.
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
Sensors used in EFI (Electronic Fuel Injection)
Flow Sensors.
I.C. ENGINES Engine Testing Practical No: 3 (24 Mar, 2014)
HYDRAULICS & PNEUMATICS
Piston Engine Operations
Gas and Liquid Metering. Why Metering? Measuring flow rate and cumulative volume Selling System Control Losses detection Reservoir outlets Pumping stations.
CENTRE OF EXCELLENCE (CHEMICAL SECTOR)
Air Conditioning Metering Devices.
Introductory Lecture Series: The Anesthesia Machine
Gas volume measurement Benedict Roth Spirometer Vitalograph Dry gas meter Wright respirometer (calibration inaccurate if used for continuous flow)
Magnetic Contactor For handling large current and voltage.
Flow Measurement Muhajir Ab. Rahim School of Mechatronic Engineering
ENTC 4350 Modern Ventilators. Modern Ventillators Ventilation assistance is provided under either of two conditions: (1) breathing initiated by a timing.
Without reference, identify principles about Anesthesia Units with at least 70 percent accuracy.
The basic physical principle behind this accelerometer (as well as many others), is that of a simple mass spring system. Springs (within their linear.
$100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100 $200 $300 $400 $500 $100.
Electric Charges & Current Chapter 7. Types of electric charge Protons w/ ‘+’ charge “stuck” in the nucleus Protons w/ ‘+’ charge “stuck” in the nucleus.
Lesson Using Pneumatic Systems. Interest Approach Can you explain how air makes a pneumatic hand tool work?
PRESENTED BY : N.SRIKAUSIGARAMAN
1 Agricultural Power Systems Identifying Engine Systems and Their Components.
Electric Charges & Current. Types of electric charge _______________ w/ ‘+’ charge “stuck” in the nucleus _______________ w/ ‘+’ charge “stuck” in the.
Principles of Carburetion. Carburetors function The carburetor works on Bernoulli's principle: the faster air moves, the lower its static pressure, and.
Introductory Lecture Series: The Anesthesia Machine
Phil. U., M Eng Dep., Measurements, Chap#7 flow measurements is very important as it covers wide ranges of applications. The flow rate measurement devices.
G.H.PATEL COLLEGE OF ENGINEERING AND TECHNOLOGY
. Government Engineering College Bharuch GROUP : 5 TAILOR HARDIK ( ) MORSIYA JENISH ( ) VANZA DIVYESH ( ) CHEMICAL DEPARTMENT.
PRESENTATION ON MEASUREMENT OF FLUID VELOCITY Submitted by:  Prativa Giri (072bme628)  Sutishna Pokharel(072bme646)
Unit III Class II Pneumatic actuators.
MAKING HEALTH CARE SAFE ENGINEERING AND SAFE ANAESTHESIA
Piped gas supply Description
GOVERNMENT ENGINEERING COLLEGE, BHARUCH.
Pressure Regulator, Pressure Gauge, Flowmeters
Electric Charges & Current
Electric Charges & Current
Sophie Young 21st February 2007
Introduction of fuel feed system
Electric Charges & Current
Electric Charges & Current
Electric Charges & Current
Pressure regulators (reducing valves)
FLOWMETERS & FLOW MEASUREMENT DEVICES
Hydraulic Flow Control • Metering Fluid Flow
Presentation transcript:

Flow Meters Flow: Volume of a fluid passing certain point over a given time Flow Rate. over a given time Flow Rate. Flow meters:sets used to measure flow either gas or liquid

Gas Flow Measurements Rotameter:variable orifice constant pr.device to control the flow of fresh gas from the anesth.machine to the pt.breath.circ. Rotameter:variable orifice constant pr.device to control the flow of fresh gas from the anesth.machine to the pt.breath.circ. Consists of :Flow tube_Float(bobbin) _Control knob. Consists of :Flow tube_Float(bobbin) _Control knob.

Flow is affected by the viscosity&density Flow is affected by the viscosity&density At low flow : viscosity At low flow : viscosity At high flow: density. At high flow: density. So,each type of gas requires diff. calibrated flow tube. So,each type of gas requires diff. calibrated flow tube. The flow tubes designed for one gas should not be interchanged with another hypoxic mixtures. The flow tubes designed for one gas should not be interchanged with another hypoxic mixtures.

Flow tube :Conical glass tube. Flow tube :Conical glass tube. Low flow tube graduated/100 ml/min. up to one liter Low flow tube graduated/100 ml/min. up to one liter High flow tube graduated/1L/min.up to 10L/min. High flow tube graduated/1L/min.up to 10L/min.

Control knob :when it is turned needle valve is opened. Control knob :when it is turned needle valve is opened. Gas flows into the bottom of the flow tube & moves upward around the bobbin upward force pushes the bobbin up in the tube. Gas flows into the bottom of the flow tube & moves upward around the bobbin upward force pushes the bobbin up in the tube.

Float (bobbin) It may be balls or cylindrical with slots in its upper part & tapered base to make it to rotate in the gas stream. It may be balls or cylindrical with slots in its upper part & tapered base to make it to rotate in the gas stream. Non spinning bobbin that may indicate O 2 is flowing while the bobbin is stucked with no adequate flow hypoxic mixture. Non spinning bobbin that may indicate O 2 is flowing while the bobbin is stucked with no adequate flow hypoxic mixture.

The density of a gas is dependent on the ambient pr. The density of a gas is dependent on the ambient pr. Large diff. in atmosph. Pr. alter the calibrat.of flow tube. Large diff. in atmosph. Pr. alter the calibrat.of flow tube. At high altitudes with hypobaric condit. Flow meter setting is less than the actual At high altitudes with hypobaric condit. Flow meter setting is less than the actual At hyperbaric condition flow setting is more than the actual hypoxic mixture At hyperbaric condition flow setting is more than the actual hypoxic mixture

The spinning movement of the bobbin can be affected by dust, dirt & static electric charges. The spinning movement of the bobbin can be affected by dust, dirt & static electric charges. Static charges can be dealt with by bimetallic strip. Static charges can be dealt with by bimetallic strip. Dirts & dusts by air filter proximal to the needle valve. Dirts & dusts by air filter proximal to the needle valve. Slots on the bobbin to spin resist the effect of static charges & dust. Slots on the bobbin to spin resist the effect of static charges & dust.

The twist required to turn the knobs must be sufficient to prevent accidental readjustment from casual knock. The twist required to turn the knobs must be sufficient to prevent accidental readjustment from casual knock. If axial push _ pull forces are applied to the needle valve spindle the flow change must not exceed 10%. If axial push _ pull forces are applied to the needle valve spindle the flow change must not exceed 10%.

O 2 /N 2 O Ratio Controllers In modern anesth.,there is interconnect. Of N 2 O & O 2 flowmeters to ensure delivery of a conc.of at least 25% O 2. In modern anesth.,there is interconnect. Of N 2 O & O 2 flowmeters to ensure delivery of a conc.of at least 25% O 2. There are 2 systems :- There are 2 systems :- 1. Pneumatic syst. ORMC (designed by Drager). 2. Chain _link 25 proportion (by Ohmeda )

Safety Measures (additional) 1. The flow tube for oxygen has been on the extreme rt. Side O 2 is the last gas to be added to the fresh gas supply. 2. A color _coded flow control knob is located under its respective flow tube.

3. A color_coded cylinder pr. gauge for the gas entering the flowmeter & located under its respective flowmeter. 4. A plastic screen used to prevent damage to the flowmeters. 5. In some machines, protective bar placed infront of the flow meters to protect from accidental bumping.

6. Lighting system for the flow meter is valuable when the op.room light is dimmed. 7. Flow tube pin _indexing syst. to prevent interchange of flow meter units hypoxic mixture.

O 2 flow can not be completely turned off. A minimum flow rate of 200_450 ml/min is delivered to provide sufficient O 2 for the basal metabolic needs by : O 2 flow can not be completely turned off. A minimum flow rate of 200_450 ml/min is delivered to provide sufficient O 2 for the basal metabolic needs by : 1. Applicat. Of resistor in the oxygen pipeline. 2. OR/stop screw on O 2 control valve.

The control knob of O 2 has esp. shape: The control knob of O 2 has esp. shape:  Octagonal  Greater diameter  Project beyond the other knobs

Other types of flow meters 1. Electronic flow meter a. Oscillations of pr. Drop across an orifice is proportional to the flow rate b. Thermister flow meter : Gas flow affects thermocouple attached to either end of flow tube Gas flow affects thermocouple attached to either end of flow tube

2. Coxter flow meter 3. Bubble flow meter 4. Rotor meter Wright’s spirometer 5. Pneumotachographs (Vitalograph) 6. Ultrasonic flowmeters 7. Electronic magnetic flowmeter