Index Velocity Best Practices ADVMs Victor Levesque USGS FISC - Tampa.

Slides:



Advertisements
Similar presentations
Quality control tools
Advertisements

In-situ ADCP.
Water Survey Of Canada Presentation to WMO Meeting on The Assessment of the Performance of Measurement Instrumentation Geneva, Switzerland April 25, 2007.
Operating the Harmonizer
SECONDARY VALIDATION OF WATER LEVEL DATA (1) PRIMARY VALIDATION: –BASED ON KNOWLEDGE OF INSTRUMENTATION AND METHODS OF MEASUREMENT WITH ASSOCIATED ERRORS.
Introduction to Acoustic Measuring Equipment
Maine Water Science Center
U.S. Department of the Interior U.S. Geological Survey Effective Review of FlowTracker Measurements OSW WebinarMike Rehmel August 27, 2013 (Please Mute.
CHAPTER FOUR Stream flow measurement
RD Instruments Home of the ADCP Measuring Water in Motion and Motion in Water THETIS Waves Data QA RD Instruments Home of the ADCP.
Chapter 10 Control Loop Troubleshooting. Overall Course Objectives Develop the skills necessary to function as an industrial process control engineer.
US Army Corps of Engineers BUILDING STRONG ® Methods for Determining Maximum Flood Elevations Landward of Failed Levees: An Example from the Great Missouri.
Abstract We quantified turbulent dissipation in the Raritan river using both conventional methods and a novel technique, the structure function method.
1 ADCP Primer OC679: Acoustical Oceanography. 2 Outline ► Principles of Operation   The Doppler Effect The Doppler Effect   BroadBand Doppler Processing.
All critical-flow devices determine flow rate by measuring one or more water levels and computing flow from a calibration equation. Water Level Sensors.
River Studies. Outline of Events During your river field work you will be visiting two different sites in the lower course of the river. At each site.
Measuring Water Velocity and Streamflow in Open-water and Under Ice John Fulton and Steve Robinson U.S. Geological Survey Joe Ostrowski Middle Atlantic.
Dan Wagner Hydrologist Arkansas Water Science Center
Review and Rating Discharge Measurements David S. Mueller Office of Surface Water March 2010.
Improved Water Resource Management Using an Acoustic Pulsed Doppler Sensor in a Shallow Open Channel MIKE COOK, PHD Irrigation Australia July
1 4 th International Symposium on Flood Defence: Managing Flood Risk, Reliability and Vulnerability, Toronto, Ontario, Canada, May 6-8, 2008 J. Chen, J.
Tsunamis Detection The Mission  Tsunamis Detection can help to minimize loss of life and property from future tsunamis. Mission Introduction Mechanism.
Discharge Measurements Created by: Jake Jacobson, ID WSC Modified by: Jeff Kitchen, CA WSC.
Chapter 9 Chapter 9: Managing Groups, Folders, Files, and Object Security.
Victor Levesque U.S. Geological Survey Florida Water Science Center Tampa, Florida Documenting Regression Analysis for Index Velocity Ratings.
How do we measure how much water is in a stream?
QARTOD II Currents and Waves In-Situ Currents: Breakout Group Report Out QARTOD II February 28 – March 2, 2005.
Software Design Project
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering AguaRed.
Modeling River Ice and River Ice Jams with HEC-RAS
Evaluating river cross section for SPRINT: Guadalupe and San Antonio River Basins Alfredo Hijar Flood Forecasting.
Discharge Measurement Concepts September 2011 – Glen Hess,TESNAR, Oregon (Many slides from USGS Surface Water Field Techniques May 2008 Class)
Principle of Index-Velocity Method and its Application Randy Marsden Teledyne RD Instruments.
1 Determining How to Calculate River Discharge HOW MUCH WATER IS FLOWING IN THE RIVER? Quantifying discharge gives us an understanding of the hydrologic.
Acquisition and Interpretation of Water-Level Data Travis von Dessonneck.
USGS Procedures for High-Flow Measurement using the Price AA Meter Annual Tri-Agency Coordination Meeting Memphis, TN Mark E. Smith USGS.
Hydrology and Water Resources RG744 Institute of Space Technology December 11, 2013.
ChannelMaster Horizontal ADCP
Module 10/11 Stream Surveys Stream Surveys – February 2004 Part 3 – Hydrologic Assessment.
Distribution System Control Strategies.  Tank Management/Operations  Flushing  Rerouting Water  Others  optimizing existing booster chlorination.
David S. Mueller U.S. Geological Survey Office of Surface Water
Discharge Measurement Concepts September 2012 – Glen Hess,TESNAR, Oregon (Many slides from USGS Surface Water Field Techniques May 2008 Class)
HydrometJanuary AMS Short Course on Instrumentation1 HydrometeorologicalMeasurements Melanie A. Wetzel Desert Research Institute University of.
Tower SystemsJanuary AMS Short Course on Instrumentation 1 Installation and Use of Meteorological Tower Systems Melanie A. Wetzel Desert Research.
Presented by Amira Ahmed El-Sharkawy Ibrahim.  There are six of eight turtle species in Ontario are listed as endangered, threatened or of special concern.
Lower Saluda River Instream Flow Study TWC Study Team Workshop December 11, 2007.
Site Selection and Security Considerations Mark Heggli Innovative Hydrology, Inc. Consultant To The World Bank Expert Real-Time Hydrology Information Systems.
Phases from Sea Echo! Why Should I Care?? Nearly ALL Current Map Velocity Errors Come from Inaccurate Bearing Estimates Three failures or sources in antennas/cabling.
LC and SMBA Updates Office of Surface Water Hydroacoustics Webinar January 6 and 9, 2008 David S. Mueller.
Copyright © 2010, 2007, 2004 Pearson Education, Inc. Chapter 6 The Standard Deviation as a Ruler and the Normal Model.
Site Selection and Security Considerations Mark Heggli Innovative Hydrology, Inc. Consultant To The World Bank Expert Real-Time Hydrology Information Systems.
ISPOL Ocean Turbulence Project Miles McPhee McPhee Research Co. Naches WA USA.
Sediment Yield and Channel Processes. Definitions Suspend Sediment – sediment (orgranic or inorganic) which remains in suspension in water for a considerable.
Mathematical Background
U.S. HYDRO 2007 TIDES WORKSHOP May 17, 2006 UNCERTAINTY WORKSHOP SKGILL SLIDES.
Bradshaw Model. Upstream Downstream Discharge Occupied channel width Channel depth Average velocity Load quantity Load particle size Channel bed roughness.
Hydrological Information System
Research and Development US Army Corps of Engineers ACOUSTIC CURRENT DOPPLER PROFILERS (ADCP’s)
DREDGEPACK® Basics.
Why use Index-Velocity Methods? Traditional Sites – Stage vs Discharge is predictable.
Hydrology and Water Resources RG744 Institute of Space Technology November 13, 2015.
RD Instruments Home of the ADCP Measuring Water in Motion and Motion in Water AVOIDING BIASED DATA DURING REAL TIME HADCP DATA COLLECTION.
Company LOGO Technology and Application of Laser Tracker in Large Space Measurement Yang Fan, Li Guangyun, Fan Baixing IWAA2014 in Beijing, China Zhengzhou.
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
U.S. Geological Survey Office of Surface Water.
A Closer Look at CODAR HF Radar Spectra
Determining How to Calculate River Discharge
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
River Channels CE 397 Flood Forecasting David R. Maidment
swingo XP Firmware, Service Tool & Error Codes
Presentation transcript:

Index Velocity Best Practices ADVMs Victor Levesque USGS FISC - Tampa

Overview Configuring SonTek ADVMs Configuring SonTek ADVMs Servicing SonTek ADVMs Servicing SonTek ADVMs Use of the Internal Data Recorder Use of the Internal Data Recorder Beam Checks Beam Checks Data to Transmit and Store Data to Transmit and Store Quality Assurance of Data Quality Assurance of Data Common Problems Common Problems

Configuring the Instrument Use SonUtils (v4.20) Use SonUtils (v4.20) Initial Setup Initial Setup Use Theoretical Flow Disturbance Estimate for Cell Begin and Blanking Distance Use Theoretical Flow Disturbance Estimate for Cell Begin and Blanking Distance Use Beam Check Signal Intensities for Cell End Use Beam Check Signal Intensities for Cell End Refine the Setup Refine the Setup Use multi-cell velocity data to verify and check for flow disturbance for Cell Begin Use multi-cell velocity data to verify and check for flow disturbance for Cell Begin Use multi-cell velocity data to verify and check for appropriate Cell End Use multi-cell velocity data to verify and check for appropriate Cell End

Configuring the Instrument Theoretical Flow Disturbance for Cell Begin and possibly Cell End Structure turbulence must be considered when establishing start of sample volume Structure turbulence must be considered when establishing start of sample volume b = c(dx) 0.5 b --lateral distance from pier centerline to edge of wake zone b --lateral distance from pier centerline to edge of wake zone d --pier width x -- distance to upstream face of pier c -- factor for pier shape round nosed 0.81 – rectangular nosed x b d

Configuring the Instrument Initially Use Beam Check for Setting Cell End Remember that scatterers in the water will change over time affecting signal strength. Cell Begin Marker Cell End Marker Instrument Noise Floor Marker Decay Curve

Configuring the Instrument Use SonUtils and SI units (meters) Set Blanking Distance (BD) = Cell Begin (CB) Set Blanking Distance (BD) = Cell Begin (CB) Enable Profiling Mode (ProfilingMode Yes) Enable Profiling Mode (ProfilingMode Yes) Choose Cell Size (CS) and Number of Cells (Ncells) to at least equal Cell End (CE) Choose Cell Size (CS) and Number of Cells (Ncells) to at least equal Cell End (CE) Example: CB = 1 meter => BD = 1 meter Example: CB = 1 meter => BD = 1 meter CE = 11 meters based on Beam Check CE = 11 meters based on Beam Check CS = 1 meter and Ncells = 10 CS = 1 meter and Ncells = 10 So multi-cell data starts at 1 meter and ends at CS * Ncells + BD = 1 * = 11 meters

Configuring the Instrument Enable Dynamic Boundary Adjustment (DynamicBoundaryAdjustment Yes) Enable Dynamic Boundary Adjustment (DynamicBoundaryAdjustment Yes) XR uses non-vented pressure sensor to set CE XR uses non-vented pressure sensor to set CE Pressure sensor is affected by atmospheric pressure changes and temperature changes. Pressure sensor can drift or fail over time Pressure sensor is affected by atmospheric pressure changes and temperature changes. Pressure sensor can drift or fail over time SW uses vertical beam level (distance) to set CE SW uses vertical beam level (distance) to set CE Note: CE = Cell End Special Considerations for XR and SW

Configuring the Instrument Enable Power Ping (PowerPing Yes) Enable Power Ping (PowerPing Yes) 1.5 MHz and 3 MHz systems 1.5 MHz and 3 MHz systems What about Sample Interval (SI) and Averaging Interval (AI)?

Configuring the Instrument Averaging Interval (AI) Averaging Interval (AI) What do you want to measure and what are the flow conditions? What do you want to measure and what are the flow conditions? Rapidly changing flow may require shorter averaging interval Rapidly changing flow may require shorter averaging interval General rule Increased averaging time => lower velocity standard deviation General rule Increased averaging time => lower velocity standard deviation Recommend 60 seconds AI and SI during discharge measurements Recommend 60 seconds AI and SI during discharge measurements

Configuring the Instrument Sampling Interval (SI) Sampling Interval (SI) 900 seconds maximum for tidally affected sites 900 seconds maximum for tidally affected sites Could be as short as 60 seconds Could be as short as 60 seconds SI >= AI SI >= AI

Configuring the Instrument Example: Steady state stream with backwater affects Example: Steady state stream with backwater affects AI = 600 seconds AI = 600 seconds SI = 900 seconds SI = 900 seconds Note: Actual settings may vary Note: Actual settings may vary Remember that if stream is flashy, shorter AI and SI may be required to measure the peak Remember that if stream is flashy, shorter AI and SI may be required to measure the peak Make sure you have enough battery and solar capacity to meet power demands Make sure you have enough battery and solar capacity to meet power demands May or may not change averaging interval during discharge measurements May or may not change averaging interval during discharge measurements

Configuring the Instrument Example: Tidally affected flow Example: Tidally affected flow AI = seconds AI = seconds SI = 60 to 900 seconds SI = 60 to 900 seconds Set AI = SI = 60 seconds during discharge measurements Set AI = SI = 60 seconds during discharge measurements Data times are extremely important Data times are extremely important

Configuring the Instrument Example: Unsteady flow due to seiche in small tributary of a larger river Example: Unsteady flow due to seiche in small tributary of a larger river What are you trying to measure? Daily flow? Short term fluctuations? What are you trying to measure? Daily flow? Short term fluctuations? AI = 60 to 780 seconds AI = 60 to 780 seconds SI = 60 to 900 seconds SI = 60 to 900 seconds Set AI = SI = 60 seconds during discharge measurements Set AI = SI = 60 seconds during discharge measurements Data times are extremely important Data times are extremely important

Configuring the Instrument Discharge measurements Discharge measurements AI = 60 seconds AI = 60 seconds SI = 60 seconds SI = 60 seconds Set StartTime (ST) hh:mm:ss Set StartTime (ST) hh:mm:ss Set StartDate (SD) YYYY/MM/DD Set StartDate (SD) YYYY/MM/DD Record Internally (disable SDI12 communication) Record Internally (disable SDI12 communication) Deploy (leave Molex plug connected) Deploy (leave Molex plug connected)

Collect Some Data

Evaluate the Configuration Use Multi-cell data to evaluate flow disturbance

Evaluating the Configuration

More obvious way to see flow disturbance is with plot of index velocity and mean velocity from measurements.

Servicing ADVMs

Servicing ADVMs with SonUtils Record a beam check (50 pings minimum) Record a beam check (50 pings minimum) Example: stationID_YYYYMMDD.bmc Example: stationID_YYYYMMDD.bmc Download ADVM internal data Download ADVM internal data Open a log file (click File in menu bar, open log file) Open a log file (click File in menu bar, open log file) Example: stationID_YYYYMMDD.log Example: stationID_YYYYMMDD.log Record instrument and watch date and time before changing (use a form) Record instrument and watch date and time before changing (use a form) Change AI and SI if necessary Change AI and SI if necessary Change StartDate (SD) and StartTime (ST) Change StartDate (SD) and StartTime (ST) Deploy ADVM Deploy ADVM Close log file Close log file

Use the Internal Recorder Valuable data set Valuable data set Use ViewArgonaut for data review Use ViewArgonaut for data review Select Processing Select Processing Open an Argonaut file Open an Argonaut file Look for anomalies in the data Look for anomalies in the data Check all available parameters Check all available parameters Check internal beam checks (DIAG) tab on menu bar Check internal beam checks (DIAG) tab on menu bar Look at signal strengths for each beam Look at signal strengths for each beam Look at multi-cell velocity data Look at multi-cell velocity data

Velocity and SNR Added QA Added QA Additional backup source Additional backup source Added understanding of site hydraulics over time Added understanding of site hydraulics over time XYZ components

Problem identified as Beam 2 issue Problem identified as Beam 2 issue …Ability To See Different Velocity Components Beam components

X/Beam 1 Relationship

Using the Internal Recorder Review the data after every site visit Review the data after every site visit Range-averaged cell velocity (X,Y, and Z) Range-averaged cell velocity (X,Y, and Z) Compare multi-cell to range-averaged velocity Compare multi-cell to range-averaged velocity Signal amplitude and instrument noise Signal amplitude and instrument noise ADVM temperature ADVM temperature Everything else Everything else Plot questionable record and add to review folder Plot questionable record and add to review folder Recommend storing internal data in ADAPS Recommend storing internal data in ADAPS

XR bio-fouling on Beams 2 and 3

XR Pressure Sensor Failure

Beam Checks Record every site visit Record every site visit Record 50 pings minimum Record 50 pings minimum Average the pings together Average the pings together Transfer and store on WSC server Transfer and store on WSC server

Beam Checks Initially Use Beam Check for Setting Cell End Remember that scatterers in the water will change over time affecting signal strength. Cell Begin Marker Cell End Marker Instrument Noise Floor Marker Decay Curve

Beam Checks

Beam Checks—What To Look For Obstructions in the sample volume

Beam Checks—What To Look For Dead beam

Beam Checks—What To Look For Possible reflection off of the bed or surface

Hardware issues—high noise floor Beam Checks—What To Look For

Fouled transducers Beam Checks—What To Look For

Fouled Transducers

Data to Transmit and Store Minimum Minimum ADVM Temperature ADVM Temperature Cell End Cell End X velocity X velocity Y velocity Y velocity Average signal to noise ration Average signal to noise ration Ideally in addition to above data Ideally in addition to above data Mean pressure if applicable Mean pressure if applicable Level if applicable Level if applicable Archive all Argonaut internal data according to WSC data archival plan Archive all Argonaut internal data according to WSC data archival plan Stream velocity, feet per second Stream velocity, feet per second Stream velocity, meters per second Stream velocity, meters per second Stream velocity, tidally filtered, feet per second Stream velocity, tidally filtered, feet per second Stream velocity, tidally filtered, meters per second Stream velocity, tidally filtered, meters per second Acoustic Doppler Velocity Meter signal to noise ratio Acoustic Doppler Velocity Meter signal to noise ratio Location of Acoustic Doppler Velocity Meter cell end, feet Location of Acoustic Doppler Velocity Meter cell end, feet Acoustic Doppler Velocity Meter standard deviation, data element specified in data descriptor Acoustic Doppler Velocity Meter standard deviation, data element specified in data descriptor Acoustic Doppler Velocity Meter standard error of velocity, feet per second Acoustic Doppler Velocity Meter standard error of velocity, feet per second Location of Acoustic Doppler Velocity Meter cell end, meters Location of Acoustic Doppler Velocity Meter cell end, meters Acoustic Doppler Velocity Meter standard error of velocity, centimeters per second Acoustic Doppler Velocity Meter standard error of velocity, centimeters per second Acoustic signal strength, units specified in data descriptor Acoustic signal strength, units specified in data descriptor

Common Problems Beam Check hangs during recording Beam Check hangs during recording Communication to internal recorder fails Communication to internal recorder fails PowerPing disabled PowerPing disabled No multi-cell data measured No multi-cell data measured Argonaut-XR pressure sensor drift or failure Argonaut-XR pressure sensor drift or failure Beam fouling – No beam checks Beam fouling – No beam checks Sensor not level Sensor not level Cell End set too long Cell End set too long Cell Begin set too short Cell Begin set too short Internal clock never checked or reset Internal clock never checked or reset Internal recorder data not reviewed Internal recorder data not reviewed

Common Problems Poor Index-to-Mean Velocity Relation Poor Index-to-Mean Velocity Relation Stage affected velocity profile Stage affected velocity profile Try multiple-linear regression Try multiple-linear regression Poor site selection Poor site selection Streambed instability Streambed instability Unstable horizontal flow distribution Unstable horizontal flow distribution Improper instrument selection or configuration Improper instrument selection or configuration XR or SW instead of SL XR or SW instead of SL Cell begin and cell end not set properly Cell begin and cell end not set properly

Tomoka River at Ormond Beach Gage Flood tide Ebb tide

Original SonTek SL Second SonTek SL SonTek XR

Site Selection Keep in mind Fundamental question– will we be able to index the mean channel velocity over the range of flows at the selected site? Fundamental question– will we be able to index the mean channel velocity over the range of flows at the selected site? Keys for a successful site Keys for a successful site Stable stream bed Stable stream bed Well mixed flow will have long-term stable vertical velocity profiles and horizontal flow distributions Well mixed flow will have long-term stable vertical velocity profiles and horizontal flow distributions Stable profiles and distributions allow us to create index-velocity ratings Stable profiles and distributions allow us to create index-velocity ratings

Reconnaissance of Potential Sites Flow conditions recon with an ADCP Flow conditions recon with an ADCP Velocity profiles Velocity profiles Depths Depths Shoals Shoals Structures Structures Other Tools Other Tools Temporary ADVM Temporary ADVM Aerial Photos, Charts, and Maps Aerial Photos, Charts, and Maps

Common Problems Wrong firmware on instrument Wrong firmware on instrument Use v11.8 for all Argonaut-SL, SW, and XR Use v11.8 for all Argonaut-SL, SW, and XR Contact USGS Hydroacoustics Contact USGS Hydroacoustics Wrong software Wrong software SonUtils v4.20 SonUtils v4.20 ViewArgonaut v3.62 ViewArgonaut v3.62 Poor Equipment Mounts Poor Equipment Mounts Allow pitch and roll adjustment Allow pitch and roll adjustment Minimize dissimilar metals Minimize dissimilar metals Allow sensor to be replaced in exact position Allow sensor to be replaced in exact position

Sensor Installation Documentation

Document and Archive Everything /flalssr003/ data logger (work/temporary) ds.archive measurements (discharge and velocity) WY2003WY2004WY _040602_000w _040602_000w _040602_000r _.wrc txt _ ckg _ bmc _ log _ arg (See note below for file type explanation.) dis wad ctl dat sum ckg adcp argonautflowtracker sta # sta # aquacalc.aqu etc. data logger archiveWY2003WY2004 ds (station #_mmddyy) (station #. measurement #)

Questions?