Lecture 31 Sinsuoidal steady state power Instantaneous and average (real) power Reactive power Complex power Power factor Related educational modules:

Slides:



Advertisements
Similar presentations
Since Therefore Since.
Advertisements

Lecture 32 Review: AC power analysis Power factor correction
Each of the circuit elements will have a different ac current response to an applied ac voltage. We need to look at each of these elements. Resistor:
Complex Power – Background Concepts
We have been using voltage sources that send out a current in a single direction called direct current (dc). Current does not have to flow continuously.
Sinusoidal Steady-State Power Calculations
CH5 AC circuit power analysis 5.1 Instantaneous Power 5.2 Average Power 5.3 Effectives values of Current & Voltage 5.4 Apparent Power and Power Factor.
AC Power: instantaneous and average power
Lecture 71 EEE 302 Electrical Networks II Dr. Keith E. Holbert Summer 2001.
ECE 201 Circuit Theory I1 Complex Power Designate as S Magnitude of S = Apparent Power Units are Volt-Amperes The complex sum of Real Power (P) and Reactive.
STEADY STATE AC CIRCUIT ANALYSIS
Lect19EEE 2021 AC Power Dr. Holbert April 9, 2008.
AC Power Discussion D9.3 Chapter 5. Steady-State Power Instantaneous Power Average Power Effective or RMS Values Power Factor Complex Power Residential.
Announcements Be reading Chapters 1 and 2 from the book
Lesson 24 AC Power and Power Triangle
Lesson 18 Phasors & Complex Numbers in AC
Lecture 26 Review Steady state sinusoidal response Phasor representation of sinusoids Phasor diagrams Phasor representation of circuit elements Related.
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
SINGLE PHASE A.C CIRCUITS
8. AC POWER CIRCUITS by Ulaby & Maharbiz. Overview.
Chapter 7 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
ENGR-43_Lec-09-2_Complex_Power.ppt 1 Bruce Mayer, PE Engineering-43: Engineering Circuit Analysis Bruce Mayer, PE Registered Electrical.
Power Triangle.
Circuits II EE221 Unit 4 Instructor: Kevin D. Donohue Complex Power, Power Conservation, Power Factor Correction, and Applications.
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
Alexander-Sadiku Fundamentals of Electric Circuits
Fundamentals of Electric Circuits Chapter 11
Lecture 27 Review Phasor voltage-current relations for circuit elements Impedance and admittance Steady-state sinusoidal analysis Examples Related educational.
ECE 2300 Circuit Analysis Dr. Dave Shattuck Associate Professor, ECE Dept. Lecture Set #25 Complex Power W326-D3.
INC 112 Basic Circuit Analysis Week 12 Complex Power Complex Frequency.
Circuits II EE221 Unit 3 Instructor: Kevin D. Donohue Instantaneous, Average, RMS, and Apparent Power, and, Maximum Power Transfer, and Power Factors.
Average Power and Power Factor ET 242 Circuit Analysis II Electrical and Telecommunication Engineering Technology Professor Jang.
Fundamentals of Electric Circuits Chapter 11
Solid State Electricity Metrology
EGN 3373 Introduction to Electrical Systems I A Systems Approach to Electrical Engineering Graphics Adapted from “Physical, Earth, and Space Science”,
1 Chapter 11 AC Power Analysis 電路學 ( 二 ). 2 AC Power Analysis Chapter Instantaneous and Average Power 11.2Maximum Average Power Transfer 11.3Effective.
AC POWER ANALYSIS Instantaneous & Average Power
Chapter 7 AC Power Analysis
Circuits II EE221 Unit 11 Instructor: Kevin D. Donohue Complex Power, Power Conservation, Power Factor Correction, and Applications.
Chapter 11 AC Power Analysis
1 Figure 7.1, 7.2 Chapter 7: AC PowerCurrent and voltage waveforms for illustration of AC power.
Lab 13 – Complex Power EE 188L. Instantaneous Power Time domain.
1 Lecture #9 EGR 272 – Circuit Theory II Read: Chapter 10 in Electric Circuits, 6 th Edition by Nilsson Chapter 10 - Power Calculations in AC Circuits.
Lecture 19 Review: First order circuit step response Steady-state response and DC gain Step response examples Related educational modules: –Section
1 ELECTRICAL TECHNOLOGY EET 103/4  Define and explain sine wave, frequency, amplitude, phase angle, complex number  Define, analyze and calculate impedance,
Unit 8 Phasors.
Chapter 10 Sinusoidal Steady- State Power Calculations
8. AC POWER CIRCUITS by Ulaby & Maharbiz All rights reserved. Do not copy or distribute. © 2013 National Technology and Science Press.
1  Explain and calculate average power, apparent power, reactive power  Calculate the total P, Q and S and sketch the power triangle. ELECTRICAL TECHNOLOGY.
E E 2415 Lecture 9 Phasor Circuit Analysis, Effective Value and Complex Power: Watts, VAR’s and Volt-Amperes.
AC POWER ANALYSIS. 2 Content Average Power Maximum Average Power Transfer Complex Power Power Factor Correction.
 Circuits in which the source voltage or current is time-varying (particularly interested in sinusoidally time-varying excitation, or simply, excitation.
AC POWER & POWER FACTOR. Lesson Objectives  Compute and define apparent, reactive, and average power for capacitors, inductors, and resistors.  Compute.
CHAPTER 2: DC Circuit Analysis and AC Circuit Analysis Motivation Sinusoids’ features Phasors Phasor relationships for circuit elements Impedance and admittance.
1 Eeng 224 Chapter 11 AC Power Analysis Huseyin Bilgekul Eeng224 Circuit Theory II Department of Electrical and Electronic Engineering Eastern Mediterranean.
FUNDAMENTAL OF ELECTRICAL POWER SYSTEMS (EE 270)
Chapter 11 AC Power Analysis
Lesson 21: AC Power and Power Triangle
Chapter 11 AC Power Analysis
Lecture 07 AC POWER & POWER FACTOR.
AC POWER & POWER FACTOR.
Sinsuoidal steady state power
Lecture 31 Sinsuoidal steady state power Related educational modules:
ECE 2202 Circuit Analysis II
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
The instantaneous power
EEE 3230 POWER SYSTEM ANALYSIS
E E 2415 Lecture 9 Phasor Circuit Analysis, Effective Value and Complex Power: Watts, VAR’s and Volt-Amperes.
Engineering Circuit Analysis
Presentation transcript:

Lecture 31 Sinsuoidal steady state power Instantaneous and average (real) power Reactive power Complex power Power factor Related educational modules: –Section 2.9.0, 2.9.1

AC power Power is still the product of voltage and current: We are now interested in the case in which the voltage and current are sinusoids:

v(t) and i(t) are related Keep in mind that power is delivered to a load The amplitude and phase of the voltage and current are not independent – They are related through the load impedance  and

Instantaneous AC power Our previous (time domain) definition of power is called the instantaneous power In terms of our sinusoidal voltage & current: After some trigonometry and algebra: – The power consists of a DC (constant) part and an AC (sinusoidal part)

Graphical representation of p(t)

Alternate representation for p(t) Which can be decomposed into two plots: – Average (real) power and reactive power

Average Power We are generally more interested in the average power delivered to a load: Average power is: – This is also called the real power (it’s the power that’s provided to the resistive part of the load over time) – Units are watts

RMS values We want to assess the power delivered by different types of time-varying signals – The power delivered to a resistive load: Find a DC (constant) value which delivers the same average power as the time-varying signal – Called the effective or RMS value of the signal – Used to “compare” different time-varying signals

Note: we want our average power to look like an “average” current squared times resistance or an “average” voltage squared divided by resistance – We want to define these “effective” values Note why it’s called “RMS”

RMS values – continued Average power: Effective DC value: Equating to time-average value:,

Annotate previous slide to show VRMS, IRMS notation (RMS = “effective”)

Definition of RMS values The effective (or RMS) value of a signal is equal to the DC value which provides the same average power to a resistor For sinusoidal signal with no DC offset:, Average power in terms of RMS values:

Apparent power and power factor Power in terms of RMS values: The average (real) power is the product of apparent power and the power factor – Apparent power: (units = volt-amps = VA) – Power factor (pf): (unitless) Power factor is leading or lagging, to denote whether current leads or lags voltage

Interpretation of apparent power and pf Power factor is a property of the load – For a complex load, the power delivered to the load is not exactly the power supplied by the generator – If Z L is real  pf = 1 – If Z L is imaginary  pf = 0, and no average power is delivered to the load

On previous slide, mention reactive power again.

Complex Power Complex power is a way to conveniently expressing the various power parameters and their relationships  or:

Annotate previous slide to show real (average) power and reactive power

Power relationships Complex power: – Magnitude of S is the apparent power (units = VA) – The real part of S is the average power (units = watts) – The imaginary part of S is the reactive power (units = VAR)

Power Triangle

Example For the circuit below, (a) find the average power delivered by the source (b) find the powers absorbed by the resistor and capacitor (c) find the apparent and reactive powers delivered by the source (d) sketch a power triangle for the source

(a) find the average power delivered by the source

(b) find the powers absorbed by the resistor and capacitor

(c) find the apparent and reactive powers delivered by the source

(d) sketch a power triangle for the source Apparent power: 391VA Average power: 305W Reactive power: -244VAR