WFR-12~24 Product presentation

Slides:



Advertisements
Similar presentations
Medium-Voltage Switchgear - Then and Now -
Advertisements

Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
Inspection & Preventive maintenance of breakers
April 27, 2012 Presented by: Andy Justice SWEDE Southwest Electric Distribution Exchange “The Evolution of Distribution Switchgear”
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
SHS2 Gas insulated switch–disconnector / isolator
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
Premset : A New generation of MV Switchgear
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
FIPTMV Medium Voltage Technology
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
INTRODUCTION TO SWITCHGEARS
VHA PANEL WITH HPA12 CIRCUIT BREAKER
SF6 load-break switch-disconnector
SUBSTATION HIGH VOLTAGE COMPONENTS
MV SF6 circuit-breakers for secondary distribution
Multi-function apparatus for secondary distribution
Medium Voltage Switchgear
Welcome DIN Rail product training ISOLATOR/MCB/RCD/RCBO
Motor Control Center MNS iS with Condition Monitoring
Pole Mounted Switch Disconnector NPS
Electrical Installation 2
Frankfurt (Germany), 6-9 June 2011 V Ramesh – India – Session 1: Network components – 1096 Integrated Switching Devices (ISD) V.RAMESH ABB Limited, Nashik,
MNS Sprint - A Market Driven Solution
Transformer Taking the ratio of the two equations
All rights reserved Gas-insulated Switchgear (GIS)
Electrical Distribution Training
All rights reserved MV SWITCHGEAR.
1200 kV AC Substations - Products and Integrated Solutions International UHV Symposium New Delhi, 29. January 2009 Edelhard Kynast Siemens AG, Energy.
AQ 100 Series Arc Flash Protection System. Characteristics of arc protection Speed, no intentional delays Sensitive, current set-points just above loads.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
Medium Voltage Outdoor Apparatus Portfolio
SF6 load break fault make switches for overhead networks
PowerIT Air Insulated Cubicle Uniswitch
Consumer’s Main Switchroom & Main L.V. Switchboard
POWER HOUSE.
Introduction to switchgears
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
SEMINAR PRESENTATION ON 220 KV GSS UDAIPUR
ON 400 KV GSS RAISER JAIPUR ROAD ,BIKANER
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
1 Pacini IT Barcelona May 2003 Improvement in the Distribution Assets Management by the Exploitation of the Innovative Component Technology.
Disconnector Switches and Earth Switches
VACUUM CIRCUIT BREAKER. WHAT IS A CIRCUIT BREAKER A circuit breaker is an equipment that breaks a circuit either manually or automatically under all conditions.
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
Uninterruptible Power Supply Improves Reliability at The Australian Synchrotron Sean Murphy – ARW 2013 Melbourne.
HIMACHAL PRADESH STATE ELECTRICITY BOARD LTD.
This project on Primary sub station of Visakhapatnam port trust at Visakhapatnam. It is 132kv/11kv substation with incoming feeder from APTransco and 11.
PPU TERANG HATI PROJECT POWER DISTRIBUTION ENGINEERING (EPEB453)
6 Week industrial Training Presentation
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Sub Station.
Sectos NXB and NXBD.
Power distribution and UPS in a single, compact system
Name, department/event, date
Circuit Breakers & Reclosers
Overview of PowerCube Units and ANSI frames
MV vacuum circuit-breakers for secondary distribution
Overview Key diagram of 220 KV Sub station, Ablowal Cables
SION Vacuum Circuit-Breaker For Standard Applications
Engineering Project Cable Management.
Components of Substation
ELECTRICAL POWER-II Electrical engineering sixth semester
All rights reserved Gas-insulated Switchgear (GIS)
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
Its strengths, your benefits
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

WFR-12~24 Product presentation SF6 Gas Insulated Ring Main Unit &Compact Switchgear WFR-12~24 Product presentation 广州五合智能电气有限公司 GUANGZHOU F-UNITE SMART ELECTRIC CO.,LTD

Secondary distribution substation Distribution 400 kV 40-70 kV 130 kV 11/22 kV Transmission Main substation 400 V Transformer

RMU in network

Applicable standards IEC 60265 : Switching and operations IEC 60420 : Switch-fuse co-operation IEC 62271-200 : Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 1kV and up to and including 52kV IEC 62271-102 : High-voltage alternating current disconnectors and earthing switches IEC 62271-100 : High-voltage alternating current Circuit breakers GB3804: Alternating-current load switchgear for rated voltages above 3.6kV and up to and including 40.5kV GB1984: High-voltage alternating current Circuit breakers GB1985:High-voltage alternating current disconnectors and earthing switches GB16927: Switch-fuse co-operation GB3906:Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6kV and up to and including 40.5kV

RMU applications Compact secondary substations Wind power plants Small industries Buildings Mining Airports Underground installations

RMU - technical data * Requires 400 series bolted bushings ** 1 sec. ratings on request

RMU modules C- cable switch F-switch fuse disconnector V-vacuum circuit breaker Sl-busbar sectionaliser Sv-with vacuum circuit breaker D-direct cable connection De-with earthing switch Be-busbar earthing M-metering

C - cable switch Snap action or latched mechanism Three position load break switch Snap action or latched mechanism Cable test bushings in front available

F – switch fuse disconnector Switch fuse combination Three phase fuse tripping Mechanism pre-charged for tripping Up and downstream dual earthing switch No jammed fuse covers - open by handle Fuse tripping in front - real blown fuse indicator Fully submersible - unique for switch fuse 400 series cable bushings available

V – vacuum circuit breaker 630A or 200A vacuum circuit breaker Latched mechanism – close and open coil Separate isolator/earthing switch Protection as specified by our customers Tripping facilitated for a wide range of relays

Sl – busbar sectionaliser Three position load break switch Interlocked earthing switch Manual or motor operation Only 325mm wide when placed between other modules

Sv – with vacuum circuit breaker 630A vacuum circuit breaker Separate isolator/earthing switch

D – direct cable connection

De – with earting switch Direct cable connection Earthing switch with making capacity

Be – busbar earthing Earthing switch with making capacity

M - Metering Air insulated and factory assembled module Type tested with specific transformers 2 or 3 pcs DIN 42600 Narrow type CT’s with ribs. 3 pcs. DIN 42600 Narrow type single pole VT’s Fuses on VT primary (optional) 400series bushings for busbar connection Bottom cable entry available

Switchgear Design (C) Three position switch Switch, disconnector, earth Arc quenching by SF6 gas Rough and reliable with a minimum of parts

Switchgear Design (F) Fuse canisters isolated in gas Whole fuse system in one module to simplify layout No climatic deterioration Earthing on both sides - simultaneous upstream and downstream Fuse cover interlock - no hazardous access Fuse solution – fully submersible

Switchgear Design (V) Vacuum circuit breaker Vacuum tube from China Interruption in vacuum Insulation provided by gas Reliable and durable No consumable parts Sealed for life Separate earthing switch

Fused protection Switch fuse combination offers optimal short circuit protection: Fast interruption Current limiting - reduces stress Cost efficient Considerations: Fuses are consumables Availability of stock Transformer size Fuse selection table supplied with each switchgear - accounting for thermal de-rating.

Relays - Selfpowered CT powered protection relay (no external power supply necessary) Economical Easy adjustment Perfect for large distribution transformers Delivery range: Circutor MPRB 99: Easy to adjust, the classic solution WIC1: New flexible relay with several characteristics including definite time PR512: Relay with advanced earth fault functions

Relays – feeder protection Advanced protection schemes Possible use of sensors Auxiliary power required Delivery range: Short circuit and earth fault protection Offers current and voltage measurement with combisensors Others on request

Arc suppressor Closed rooms In the rare event of arc-fault 3 phase earthing switch Reacts on pressure No fatal pressure increase No arcing gases No need for ventilation All parts inside the tank Superior solution for: Crowded areas Closed rooms Underground installations

Mechanism and interlocks Rough and reliable mechanisms Minimum of moving parts High number of operations Latched snap action is availabe Mechanical interlocks - internally, not on the front covers - fuse compartment - cable compartment (option) - cable test compartment (option) True position indication Padlocking device C mod. F mod. V mod.

Cable termination - bushings Serie 600, bolted, 630A Serie 200, bolted, 200A

Cable connection All bushings - same height Simplified installation: Front dismantle Cable cut one length Revolving Adjustable cable support Double adapters (e.g.NKT) and surge arresters fits behind cable cover Double front covers available Arc proof cable compartment available

Remote control and monitoring Integrated solution with main components: RTU211: 16DI, 8DO, 6AI, 24-110VDC Additional I/O: 16DI (option) Battery charger (110 or 220VAC/24VDC or 48VDC) Batteries 2x12VDC (20Ah) Communication devices V23 fixed line modem Dial up modem RS-232 for external devices Heater (optional) Surge arresters (aux supply and communication interface)

Installation and maintenance Compact design Easy to install and connect Open front cable entry Commissioning - factory tested Maintenance - on demand only NO live parts exposed Minimum number of parts Fully sealed and screened unit Virtually maintenance free At site conditions decides

Production facilities 成套设施,一次完成抽真空、氦气检漏、充SF6气体多种功能。 成套设施,一次编程完气箱焊接功能。

Typical application(1) DF CF CFC CFF CCC CCF FCC CFFF CCFF CCVV

Typical application(2) CCCC CCCF CFFC CCCCC CCFFF CCCFF CFFFF CCCCF