Data centres are dynamic computer environments. In recent years the increasing mix of old and new computer technologies is causing the overall power factor.

Slides:



Advertisements
Similar presentations
Achieving Price-Responsive Demand in New England Henry Yoshimura Director, Demand Resource Strategy ISO New England National Town Meeting on Demand Response.
Advertisements

DC-DC Fundamentals 1.4 Charge Pump Regulator
G.E. UPS Productline.
11/27/2007ILC Power and Cooling VM Workshop Mike Neubauer 1 RF Power and Cooling Requirements Overview from “Main Linac Power and Cooling Information”
Surrey Fire & Rescue Service provides a 24/7 '999' call centre available to all residents and visitors to their county as well as supporting cover to neighbouring.
Increasing the Efficiency of UPS Systems – And Proving It!
Tesco PLC has awarded the contract to maintain its uninterruptible power supplies (UPS) at its nationwide distribution centres to Uninterruptible Power.
The battery plays a key role in the overall reliability and availability of a power protection system. It supplies the energy required by the critical.
IEA HPP Annex 28 Calculation method Workshop IEA HPP Annex 28 8 th International Heat Pump Conference, Las Vegas, 30 May 2005 Carsten Wemhöner, Operating.
LP33 Series UPS kVA 400Vac/CE
High availability is one of the most important issues in computing today. Understanding how to achieve the highest possible availability of systems has.
LHC UPS Systems and Configurations: Changes during the LS1 V. Chareyre / EN-EL LHC Beam Operation Committee 11 February 2014 EDMS No /02/2014.
Per Unit Representation Load Flow Analysis Power System Stability Power Factor Improvement Ashfaq Hussain.
Delta Confidential DES UPS introduction UPS training June 2006 Markus Schwab.
DC-DC Fundamentals 1.1 An Introduction
Buck Regulator Architectures
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
POWER SUPPILES LECTURE 20.
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
During a mains supply interruption the entire protected network is dependent on the integrity of the UPS battery as a secondary source of energy. A potential.
PARMENANT MAGNET SYNCHRONOUS GENERATOR BY JA’FAR R.A. AZIM Assem M.A. Al ighrair.
By: Professor Wilmer Arellano
Providing continuous power to critical processing and communication applications such as data centres, online banking and emergency services is essential,
UPS series PROTECT 1.M Scalable UPS in n+x technology Modularity with double conversion UPS modules True sine wave - output.
There are three distinct types of isolation in a UPS system: the galvanic isolation between input and output, the input isolation between mains and battery,
The primary objective in the implementation of a UPS system is to improve power reliability to the limits of technical capability, the ultimate aim being.
When Colt Data Centre Services decided to be among the first to manufacture the next generation of modular data centres it turned to Uninterruptible Power.
GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior.
SitePro UPS 400Vac / CE GE Consumer & Industrial August 2004.
SUSTAINABLE ENERGY REGULATION AND POLICY-MAKING FOR AFRICA Module 13 Energy Efficiency Module 13: SUPPLY-SIDE MANAGEMENT.
Uninterruptible Power Systems
POWER PLANT USED IN TELECOM
InnovationValueTeamwork SHENZHEN INVT ELECTRIC CO., LTD.
When AEGON decided to create a new power infrastructure including power protection at its Edinburgh facility, the company turned to Uninterruptible Power.
Whenever the public are involved, safety is always a primary concern. Theatres are no exception and require total reliability from their emergency applications.
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
CONCEPTPOWER DPATM Newave unique MODULAR power protection concept for mission critical applications Conceptpower DPA 28 March 2011.
UPS network perturbations in SX2 Vincent Chareyre EN-EL-SN ALICE Technical Coordination Meeting 7 May 2010.
By J DAVID MANOHAR (08A31A0232). NECESSITY OF SUPERCONDUSTOR  Damage from short circuit is constant threat in power systems  All the power systems components.
Re-Commissioning of the Water Cooling System at Université de Sherbrooke Department of Buildings June 2008.
UPS sizing rev Show information... Navigation links: Move the cursor across the links and wait for the “hand” symbol - then click left mouse key.
Management and Organisation of Electricity Use Electrical System Optimisation Belgrade November 2003.
Power Usage Effectiveness Index- Electrical Systems DATA CENTER Hareesha K Texas Instruments.
Dealing with Hotspots in Datacenters Caused by High-Density Computing Peter Hannaford Director of Business Development EMEA.
RACK Mountable & Modular Continuous Power Protection Availability
Power Protection Stowe Australia Welcomes QESTnet Data Centre Construction Workshop Seminar Stowe Australia Welcomes QESTnet Data Centre Construction Workshop.
Electrical Systems Efficiency Bill Tschudi, LBNL
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
Power Quality Product Overview
Predicting the In-System Performance of the CMS Tracker Analog Readout Optical Links Stefanos Dris CERN & Imperial College, London.
LP Series 400V CE GE Consumer & Industrial September 2004.
Delta Conversion Benefits rev Silcon DP300E Delta-conversion The future-proof UPS.
CERN - IT Department CH-1211 Genève 23 Switzerland t Power and Cooling Challenges at CERN IHEPCCC Meeting April 24 th 2007 Tony Cass.
1\ Backup system for solar on-grid installation 1 1pcs XTM inverter charger, nominal power 3.5KVA, 30min. Power 4KVA AC DC Load2 (secured power)
INVERTER TECHNOLOGY.
InfraStruXure Systems Alex Tavakalov
UPS SG-CE Series 300 kVA. SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 2 Product portfolio CE Marked, 3x380/400/415V.
A DSP based on on-line UPS R.Padamaja G.Mamatha Reddy EEE EEE S.V.C.E S.V.C.E BY.
Energy Conference and Exhibition 2007 Best Practices for Energy-Efficiency in Critical Power Applications Kit Killingsworth.
Power Factor Correction The Definitive power solution
SMPS.
Auxiliary power supply (APS) Hossein Harimi 2014
RACK Mountable & Modular Continuous Power Protection Availability
M.KARTHIK (10F41D4307) Under the esteemed guidance of
LV Safe Powering from UPS to Clients
RACK Mountable & Modular Continuous Power Protection Availability
Vita 83 Working Group proposal for Rugged packaging,
Best-in-class modular UPS ensuring business continuity
Presentation transcript:

Data centres are dynamic computer environments. In recent years the increasing mix of old and new computer technologies is causing the overall power factor of the computers/servers to shift towards unity. Furthermore with the introduction of powerful blade servers the overall power factor may even become leading. This server evolution is becoming a big challenge for IT managers as most of the installed legacy UPS systems, with PWM (pulse width modulated) inverter switching, are designed to provide maximum power at lagging power factors. These UPS systems are approaching their kW power limits due to the change of loads from lagging to leading power factors, or may even shift into an overload condition. The majority of legacy UPS topologies that are installed in IT environments experience a typical derating up to 30% compared with modern Transformerless topologies. Derating of UPS topologies with leading loads Legacy UPS topologies are designed to provide maximum kW power for lagging loads, typically at PF = 0.8. If the load shifts from lagging to leading PF, legacy double-conversion UPSs will derate substantially and hence reach or exceed their rated power. The PWM inverter switching in most transformer-based UPS systems is slower and does not manage to avoid derating when supplying loads with leading PF. Modern Transformerless UPSs with adaptive inverter switching experience a limited derating at unity and leading PF. White paper: The impact of leading power factor of blade servers on derating of UPS systems There is one solution to the power protection challenges posed by mixing new computer technologies with legacy IT equipment Figure 1 UPS derating versus leading loads (300kVA) UPS Transformerless UPS (typical) Legacy double conversion UPS with rated output PF = 0.8 (typical) kVA lead206kW152kW 0.85 lead220kW166kW 0.90 lead232kW182kW 0.95 lead240kW214kW kW 0.95 lag240kW 0.90 lag240kW 0.85 lag240kW 0.80 lag240kW

Figure 2 Power (kW) versus power factor If a legacy UPS is supplying a load with traditional servers and the IT manager decides to introduce blade servers to achieve higher computing density, the power demand will grow and the legacy UPS may reach its power limits or may even be in overload. In this case, there are various ways to overcome the problem. 1. Replace existing legacy UPS with a legacy UPS of higher output power rating. This may cause changes in the power distribution and installation, and is a high cost solution. 2. Add another parallel UPS to the existing legacy UPS. This may cause changes in the power distribution and installation and is a very high cost solution. 3. Replace legacy UPS with a Transformerless UPS which provides more power for leading loads. This is a lower-cost solution. When new data centre power requirements are assessed it is very important to evaluate the power that the specified UPSs can provide at leading power factors. The shift to leading power factors gives a clear advantage to Transformerless UPSs with respect to legacy UPSs. Due to the substantial derating of legacy UPSs when powering loads with leading power factors, it will be possible in many cases to specify a smaller Transformerless UPS against a larger legacy double-conversion UPS. UPS Figure 1 shows typical values of power versus load power factor for both modern Transformerless and legacy UPS topologies. Legacy UPS topologies (300kVA) typically provide 214kW at PF = 0.95 lead, which corresponds to 11% derating with respect to the rated power at PF = 0.8 lag, and 182kW at PF = 0.90 lead, which corresponds to 24% derating. Transformerless UPSs (300kVA) experience no derating up to PF = 0.95 lead with respect to the nominal power at PF = 0.8 lag, and have a derating of approximately 3% at PF = 0.90 lead. Figure 2 shows that the Transformerless UPS can provide substantially more power than equivalent legacy UPSs. The 300kVA Transformerless UPS provides up to 26kW more power for a 200kW load with PF = 0.95 lead, or up to 50kW more power for a 200kW load with PF = 0.90 lead, than equivalent legacy UPSs, which corresponds to 25% of the total load value.

Figure 3 Comparison of two UPS topologies’ performance in relation to blade servers (assuming a 200kW load and PF = 0.9 lead ) Uninterruptible Power Supplies Limited is currently involved in the development of data centres where the introduction of blade servers is presenting a challenge. With the company’s PowerWAVE Transformerless UPS topology, the data centre manager can respond to most of the power growth demand that cannot always be accommodated by legacy equipment. PowerWAVE Transformerless UPS topology offers these advantages for data centres: ■ low derating for leading computer power factors up to PF = 0.9 lead ■ lower installation costs than those associated legacy UPS ■ no need for over-sizing of the generator thanks to low THDi ■ less energy loss and less heat dissipation (meaning lower air conditioning costs) thanks to high efficiencies. Contact Uninterruptible Power Supplies Ltd Bacchus House Calleva Park Aldermaston Berkshire RG7 8EN Phone: Web: UPS Meeting the challenge Figure 3 shows how two typical UPS topologies cope with blade servers with leading input power factor, which represents a major challenge for legacy double-conversion UPS. The shift to data centres with leading power factors opens the door to the competitive advantages of Transformerless UPS, particularly in the output power range from 160 to 300kVA, single and parallel configurations. PowerWAVE Transformerless UPSTypical legacy UPS Rated UPS power300kVA Effective power at PF = 0.9 lead 232kW (86% of UPS rated power) 182kW 10% OVERLOAD! NEED FOR A LARGER UPS Losses at full load of 200kW 14kW (93% efficiency 22kW (89% EFFICIENCY HIGH LOSSES!) Genset over-sizing factor INCEASED GENESET COST