Similar presentations
UNIVERSITY of NORTHERN COLORADO HOT WORK PROGRAM.
Advertisements

Fired And Unfired Pressure Vessels
East Carolina University Compressed Gas Safety Training Program
Waste Management CNG Vehicles. Objectives The student will be able to… Define CNG and it’s Hazards Understand CNG Cylinder Limitations Identify CNG WM.
Biodiesel & Fire Permits Presented by the Seattle Fire Department for the Department of Ecology Biodiesel Permitting Workshop Seattle, Washington February.
1926 Subpart J Establishes the requirements for welding and cutting in the construction industry Establishes requirements for equipment, fire protection,
N.F.P.A. 13R Justin Bohlmann FIR-204.
Welding, Cutting, and Brazing
1 Hot Work Permits Corporate Environment Safety & Health.
NATURAL GAS & LNG AS ENGINE FUEL Jim Lewis, PE, PEng LNG Expertise, LLC May 21, 2014 Great Lakes Maritime Research Institute 1.
World Forum for Harmonization of Vehicle Regulations (WP.29) Working Party on Pollution and Energy (GRPE) 66 th session, 4-7 June 2013 Information about.
Site Planning and Layout  In the design phase of a facility, fire protection requirements are considered in the site layout  Water supply, traffic and.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
Hydrogen Workshop for Fleet Operators. Module 3, “Vehicle Operations and Maintenance Facilities”
Safety Standards for LNG Fueled Vessels Marine Chemist Qualification Board Baltimore, MD October 23, 2014 CAPT John W. Mauger Office of Design & Engineering.
MVFRI 1 Fire Safety of Hydrogen-Fueled Vehicles: System-Level Bonfire Test by R. Rhoads Stephenson Motor Vehicle Fire Research Institute
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Liquid Fuel Safety Cummins Southern Plains, Ltd..
Partner for progress Kiwa Nederland B.V. Automotive department Paul Dijkhof Informal document GRSG (103rd GRSG, 2-5 October 2012 Agenda item 7)
A Look at Natural Gas FAPT– 2/21/14 1.
National Alternative Fuels Training Consortium Automotive Shop Preparation for Gaseous Fuel Vehicles August 6, 2014 Presenter: Bill Davis, Director.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
OVERVIEW COMBUSTIBLE DUST QUIZ: Management Level Produced under OSHA Susan Harwood Grant SH
Sohail Ghanchi Energy Technology and Policy The University of Texas at Austin.
CNG & LNG Fleet Facility Modifications 101 Your Speaker: Stephe Yborra Director, Markets & Technology Development NGV America Your Host: David Orton Senior.
Standard 29 CFR Part Flammable & Combustible Liquids.
Patrick Thornton, SNS/FPE June 9, 2008
Illumination for Industrial Painting Projects Presented by: William Hansel, Caltrans.
1 Fire risk assessment Samuel Nii Tettey (Ergonomist)
Flammable and Combustible Liquids
Process Safety Management
NFPA 31 Standard for the installation of Oil- Burning Equipment
Flammable and Combustible Liquids Presented by Martina Schmeling Adapted From OSHA.
HAZARDOUS MATERIALS. OSHA Office of Training and Education - Revised by TEEX 12/05/07 2 Terminal Objective Describe the hazards and requirements of working.
Fire Prevention for Construction. Four classes of fires  A, B, C, and D 1a.
Safe Operation of Storage Tanks: Decommissioning and Repair
AC Transit Hydrogen Energy Station / Oakland Fire Department Project AC Transit Hydrogen Energy Station / Oakland Fire Department Project You want to do.
Updated Space Heater Policy For Weatherization -- Draft National Weatherization Training Conference Orlando, FL December 10, 2007.
Basic Awareness Training for all Staff
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
MODULE 6 Vehicle Parking, Servicing, and Security.
1 | Weatherization Assistance Program: The Federal Perspective (Part 1)eere.energy.gov NASCSP 2011 Mid-Winter Training Conference Weatherization Assistance.
Student Book © 2004 Propane Education & Research CouncilPage Performing Gas Distribution System Leak Checks Requirements for vapor distribution.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
What is a safe work permit? A safe work permit is a written record that authorizes specific work, at a specific work location, for a specific.
NFPA 2 Overview Susan Bershad, Staff Liaison, NFPA.
Confined Spaces. Definition: Are large enough that an employee can bodily enter them Are not designed for continuous occupancy. Have limited or restricted.
FLAMMABLE AND COMBUSTIBLE LIQUIDS 1 Bureau of Workers’ Comp PA Training for Health & Safety (PATHS) OSHA 29CFR PPT
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
Fire Sprinkler System Presentation By Harold Stewart City Manager November 17, 2014.
Flammable and Combustible Liquids Standard 29 CFR Part City of Council Bluffs Presented by: SilverStone Group © 2006, 2012 Zywave, Inc. All rights.
Welding, Cutting, and Brazing
JLAB Pressure Systems Considerations Ed Daly. Outline Introduction Federal Law - 10CFR851 Compliance JLAB Pressure Systems Program –Complies with 10CFR851,
© National Fire Protection Association. All rights reserved. NFPA Consensus Standards at Work What is NFPA 59A and how does it apply April 12, 2016 Guy.
BY FRANS WILBRINK WILBRINK & ASSOCIATES. OUTLINE Classify the different types of hazardous areas Identify the risks associated with each of these areas.
Fundamental Concepts for Design of Special Hazard and Fire Alarm Systems Chapter 1.
Hot Work Permit Osan AB Fire Emergency Services.
Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Flammable Liquids Directorate of Training and Education
Process Safety Management Soft Skills Programme Nexus Alliance Ltd.
UNIT-III MAINTENANCE OF SAFETY
Chapter 9 Safety Permit Systems
THUM Adapter Impact on Hazardous Area Classification
Flammable and Combustible Liquids
East Carolina University Compressed Gas Safety Training Program
Wildfire Development Permit UPdate
Understanding the Space Park Requirements
Global Safety Standard Orientation Line and Equipment Opening
Community Practice Asset Management.
Presentation transcript:

Director of Market Development - NGVAmerica Determining Modifications Required for Adding CNG or LNG Vehicles to Existing Maintenance Facilities Stephe Yborra Director of Market Analysis, Education & Communications - Clean Vehicle Education Foundation Director of Market Development - NGVAmerica

Today’s Agenda Define the Problem/Opportunity Review Applicable Codes & Standards Intent /Rationale/Assumptions Behind Codes’ Development Assess Current Activities in Facility, Potential Practices and Approaches to Reduce Modification Requirements Discuss Applicable Code Requirements for CNG and LNG in “Major Repair” Facilities Maintenance Facility “Best Practices” When Incorporating CNG/LNG Vehicle into Your Fleet

Defining the Problem/Opportunity NGV deployment is accelerating quickly, especially in fleet sector. Economies of scale favor RTB and P2P fleets’ adoption; most have centralized service facilities Regional/long haul trucking and fueling operations will necessitate more ubiquitous CNG-/LNG-capable service garages Lack of familiarity with NGV technology and applicable codes among fleets, design consultants and AHJs Codes are “performance” docs, relying on hazard assessment, mitigation Diversity of facility designs/construction leads to variable interpretations Conflicting codes, outdated government guidance and vendor misinformation exacerbate confusion and over-cautiousness, leading to overly expensive retrofits Opportunity: Knowledge/light on subject can avoid costly errors and facilitate wider adoption of NGVs more quickly

Properties of CNG and LNG Natural gas: 88-99% methane (nat’l avg: 93%) Methane is CH4 (low carbon, energy-dense fuel) Lighter than air (specific gravity: .55-.65) Limited combustion ratio (5-15%) High ignition temperature: 1000+F Colorless, odorless, non-toxic substance Compressed Natural Gas (CNG) Onboard fuel storage: 3600psi Mercaptan is added to L/CNG Liquefied Natural Gas (LNG) Cryogenic liquid @ -260F; Methane content: ~95+% 1 cu ft of LNG = 600 cu ft of natural gas @ atmospheric pressure; 3.5 lbs/gallon Liquid LNG is not ignitable; vaporizes @ approx ~ -155F (lighter than air). Methane Molecule

Applicable Codes to Vehicle Maintenance Facilities International Code Council’s Intl Fire Code (IFC 2012) International Mechanical Code (IMC 2012) International Building Code (IBC 2012) National Fire Protection Assoc. (NFPA) 30A (2012) Code for Motor Fuel Dispensing Facilities and Repair Garages NFPA 52 (2010) Vehicular Gaseous Fuel Systems Code NFPA 88 (2007) Standards for Parking Structures These national codes are voluntarily adopted by states and local jurisdictions. Local codes often are not the most recent versions of national model codes (adoption often lags behind). Local AHJ is final decision-making authority and may enforce additional requirements.

Code Intent/Rationale/Assumptions Most CNG-/LNG-related codes developed in mid-late1990s based on perceived hazards based on experience of code committees Primary CNG concern: Unintended release in enclosed space. Early PRD’s designs were flawed and/or they were improperly selected and the result was unintended venting of CNG cylinders (most were transit applications). Codes developed based on 150% of largest CNG cylinder (50% safety factor). US FTA issued facility “guidance” tied to funding (1996-97) that went far beyond current codes. PRD standards were revised but FTA guidance still in place Not a single premature PRD failure/release in 10+ years.

Code Intent/Rationale/Assumptions Most CNG-/LNG-related codes developed in mid-late1990s based on perceived hazards based on experience of code committees Primary CNG concern: Unintended release in enclosed space. Primary LNG concerns: Venting due to pressure build-up, and liquid release due to puncture Vacuum insulated LNG tanks will still absorb energy and thus a 15psig/day energy gain leads to hold time of 6-7 days before venting. There are various operational procedures to minimize potential for release during planned maintenance activity. No record of a LNG liquid spill in a maintenance facility Empirical/CFD research underway to better model NG behavior

Evaluate Shop Activities, Segregate, Modify IFC and NFPA 30A exempt minor repair facilities from code requirements specific to CNG and LNG. IFC 2211.7 exempts garages that do not work on fuel systems or do not use open flames or welding from all additional requirements NFPA 30A exempts garages that do not perform: Engine overhauls, painting, body & fender work, any repairs requiring draining of vehicle fuel tanks NFPA 30A define minor repair facility maintenance activity as: Lubrication, inspection, engine tune-ups, replacement of parts, fluid changes, brake system repairs, tire rotations and similar routine maintenance work

Evaluate Shop Activities, Segregate, Modify IFC and NFPA 30A exempt minor repair facilities from code requirements specific to CNG and LNG. To avoid costly modifications, consider: Segregating major repair and minor maintenance activities into separate physical areas; adding NGV-specific bay(s) for major repairs Defueling CNG and/or LNG vehicles before entering major repair area Diesel and gasoline vehicle repair / maintenance CNG/LNG minor maintenance and (defueled NGV) major repair CNG/LNG major repair

Existing Code Requirements by Category (as it relates to maintenance/repair and parking* facilities) Modification Category Code Reference Ventilation Category IMC (2012) Table 403.3; NFPA 88A (2007) 5.3.2 IFC (2009) 2211.7.1, 2211.1.1, 2211.7.1.2; NFPA 30A (2012) 7.5.1, 7.5.2, 7.5.3, 7.5.4, 7.4.7.2, 7.4.7.3 Ventilation in Pits IFC (2009) 2211.3; NFPA 30A 7.4.5.4 Gas Detection IFC (2009) 2211.7.2, 2211.7.2.1, 2211.7.2.2, 2211.7.2.3; NFPA 30A (2012) 7.4.7, 7.4.7.1, 7.4.7.2, 7.4.7.3, 7.4.7.4 Sources of Ignition NFPA 30A (2012) 7.6.6 Electrical Classification NFPA 30A (2012) 8.2.1 Preparation of vehicles For Maintenance IFC (2009) 2211.5 Maintenance and Decommissioning of containers NFPA 52 (2010) 6.13, 6.14

Facility Modifications to Accommodate Work on CNG/LNG Vehicles Ventilation Rate = 1 cu ft/sq ft No Bring ventilation rates up to code Yes Minor Repairs Only No modifications required by the codes Garage Type Major Repair Garage Approval by AHJ required Natural LNG or both fuels CNG only Natural Approval by AHJ required Type of ventilation Fuel Type to add to garage Type of ventilation Mechanical LNG or CNG Mechanical Inspect and prepare NGV prior to performing maintenance Ventilation rate should be 5 ACH Ventilation rate should be 5 ACH Install Fuel Appropriate Defueling System Install gas detection system as required by codes No gas detection system required Electrical Classification Open flames and +750°F Surfaces Space is a Class 1 Division 2 Classified location Less than 4 ACH Remove the sources of ignition in areas subject to ignitable mixtures Ventilation rate within 18” of ceiling Sources of ignition 4 ACH or more Space is not considered a classified location

Facility Modifications to Accommodate Work on CNG/LNG Vehicles Ventilation Rate = 1 cu ft/sq ft Facility Modifications to Accommodate Work on CNG/LNG Vehicles No Bring ventilation rates up to code Does existing maintenance facility meet ventilation code? IMC 403.3 requires repair garages (of all vehicle fuel types) to have minimum ventilation rate of .75 cfm/sqft NFPA 88A 5.3.2 requires 1.0 cfm/sqft for all parking structures. Would seem to indicate that all service garages be considered parking structures Result: 1cfm/sqft

Facility Modifications to Accommodate Work on CNG/LNG Vehicles Ventilation Rate = 1 cu ft/sq ft No Bring ventilation rates up to code Yes Garage Type Minor Repairs Only No modifications required by the codes Major Repair Garage Fuel Type to add to garage Operation of Ventilation in Major Repair Facility with CNG Vehicles IFC 2211.7.1 Continuous operation except when interlocked with with lighting circuit. NO METHANE DETECTION REQUIRED FOR ODORIZED CNG. Rate = 1cfm/12 cu ft of space (5 ACH) NFPA 30A Silent on operation requirements for CNG repair facilities (only for fuel dispensing facilities). NO METHANE DETECTION FOR ODORIZED CNG. Both allow AHJ to allow natural ventilation No mention by either code re CNG-specific ventilation rate for pits (Clue: lighter than air) Type of ventilation CNG only Mechanical Approval by AHJ required Natural Ventilation rate should be 5 ACH No gas detection system required

Facility Modifications to Accommodate Work on CNG/LNG Vehicles Ventilation Rate = 1 cu ft/sq ft No Bring ventilation rates up to code Yes Garage Type Minor Repairs Only No modifications required by the codes Major Repair Garage Fuel Type to add to garage Sources of Ignition IFC 2211.3 Only addresses liquid fuels re no ignition sources within 18” of FLOOR (also referenced in IBC, IMC, NFPA 70) NFPA 30A 7.6.6 Requires elimination of open flames and/or surfaces with temps of 750°F or more (e.g. , direct-fired unit heaters, infrared heaters). Typically means use of indirect heating systems with ductwork, etc Type of ventilation CNG only Mechanical Approval by AHJ required Natural Ventilation rate should be 5 ACH No gas detection system required Sources of ignition Open flames and +750°F Surfaces Remove the sources of ignition in areas subject to ignitable mixtures

Facility Modifications to Accommodate Work on CNG/LNG Vehicles Ventilation Rate = 1 cu ft/sq ft No Does HVAC system effectively ventilate at 4 ACH here? Bring ventilation rates up to code Yes Garage Type Minor Repairs Only No modifications required by the codes Sources of Ignition - Electrical IFC 2211 No specific reference to CNG, LNG NFPA 30A 8.2.1 Areas within 18” of CEILING are Class I, Division 2 unless that area has at least 4 ACH. AHJ will have to evaluate if roof type and construction methodology allows for effective ventilation to meet 4 ACH If < 4 ACH, then electrical must meet Class 1, Division 2 or be moved out of 18” ceiling zone Major Repair Garage Fuel Type to add to garage Type of ventilation CNG only Mechanical Approval by AHJ required Natural Ventilation rate should be 5 ACH No gas detection system required Sources of ignition Ventilation rate within 18” of ceiling Electrical Classification Open flames and +750°F Surfaces Remove the sources of ignition in areas subject to ignitable mixtures Space is a Class 1 Division 2 Classified location Less than 4 ACH Space is not considered a classified location 4 ACH or more

Facility Modifications to Accommodate Work on CNG/LNG Vehicles Ventilation Rate = 1 cu ft/sq ft No Bring ventilation rates up to code Yes Minor Repairs Only No modifications required by the codes Garage Type Major Repair Garage Approval by AHJ required Natural Type of ventilation Mechanical Fuel Type to add to garage Ventilation in major repair facility with LNG Vehicles or both LNG and CNG Vehicles LNG or both fuels Ventilation rate should be 5 ACH IFC 2211 IFC 221.7.1 Continuous operation of ventilation system @ 1cfm/12cu ft (5 ACH) except when interlocked with gas detection system for LNG. NFPA 30A 7.4.7 Must interlock ventilation system and methane detection system Both permit AHJ to allow natural ventilation. Regardless of ventilation strategy, LNG requires methane detection system Install gas detection system as required by codes

Facility Modifications to Accommodate Work on CNG/LNG Vehicles Ventilation Rate = 1 cu ft/sq ft No Bring ventilation rates up to code Yes Minor Repairs Only No modifications required by the codes Garage Type Major Repair Garage Approval by AHJ required Natural LNG or both fuels Type of ventilation Fuel Type to add to garage Sources of Ignition Open flames and hot surfaces – same as CNG Electrical Classification – same as with CNG Mechanical Ventilation rate should be 5 ACH Install gas detection system as required by codes Electrical Classification Open flames and +750°F Surfaces Space is a Class 1 Division 2 Classified location Less than 4 ACH Remove the sources of ignition in areas subject to ignitable mixtures Ventilation rate within 18” of ceiling Sources of ignition 4 ACH or more Space is not considered a classified location

Facility Modifications to Accommodate Work on CNG/LNG Vehicles Ventilation Rate = 1 cu ft/sq ft No Bring ventilation rates up to code Yes Minor Repairs Only No modifications required by the codes Garage Type Major Repair Garage Regardless of ventilation system operation, methane detection requirements, interlocking, etc…. Inspect/prepare your NGV IFC 2211.5 – Isolate fuel container from rest of system Inspect for leakage NFPA 30A – No mention RP: Operate NGV until it stalls after isolating fuel source Fuel Type to add to garage Inspect and prepare NGV prior to performing maintenance LNG or CNG

Facility Modifications to Accommodate Work on CNG/LNG Vehicles Ventilation Rate = 1 cu ft/sq ft No Bring ventilation rates up to code Yes Minor Repairs Only No modifications required by the codes Garage Type Maintenance/decommissioning of fuel containers CNG cylinders have specific end-of-useful life date (see label). LNG tanks do not. NFPA 52.6.13 (2013): Written procedures should be in place for inspection and decommissioning of CNG cylinders. (Training of staff is recommended) NFPA 52.6.14 (2013): Major repair garage should install appropriate defueling apparatus (capture or direct atmospheric venting) Major Repair Garage Fuel Type to add to garage Inspect and prepare NGV prior to performing maintenance LNG or CNG Install Fuel Appropriate Defueling System

Shop Design/Modification Considerations Diesel and gasoline vehicle repair / maintenance CNG/LNG minor maintenance and (defueled NGV) major repair CNG/LNG major repair Interior walls will have a 2-hr fire rating and be continuous from floor to ceiling For major repair area, at least one wall shall be an exterior wall and primary access shall be from the outside Interior access between minor and major repair areas shall be through self-closing fire door with AHJ approved rating The minor and major repair areas shall have separate ventilation systems

Summary R&D underway to determine ppm levels, dispersion models, etc Current guidance is vague; many costly “myths” about requirements prevail; confusion within design, vendor and code enforcement community Guidance is based on assessing risks and modifying accordingly Modifications only if “major repairs” are to be performed If no CNG system work is to be performed, i.e., basic maintenance (e.g. brakes, etc) – no modifications required If CNG work is to be performed, modifications may be needed Consider segregating major repair and minor maintenance areas Key considerations in whether or not – and to what extent – to modify: Ventilation levels; properly designed ventilation should eliminate “ignitable mixture” Elimination of hot surfaces above 750⁰F (e.g. indirect heat or AHUs) Modification of electric only if within 18” of ceiling if minimum ACH is not achieved Methane detectors not needed for CNG; only for non-odorized gas (i.e., LNG) Not necessary to install “explosion proof” switches, sockets or redo all electrical systems R&D underway to determine ppm levels, dispersion models, etc