Industrial Systems Introducing the L90 Universal Relay Advanced transmission line protection and control High-speed current differential protection for.

Slides:



Advertisements
Similar presentations
DAQMASTER Features and Benefits
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
1 Effective, secure and reliable hosted security and continuity solution.
SSE Remote Telemetry Unit SSE RTU
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
UR - The Universal Relay
The Widest Range of Bluetooth Barcode Scanners
VAMP 300 IED functionality Feeder relay Motor relay
1 GE Digital Energy Multilin Industrial Solutions for Energy Management and Energy Efficiency By John S. Levine, P.E. Levine Lectronics and Lectric, Inc.
Multi Functional Digital Fault Recorder
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
1 Industrial Systems Advanced Protection, Monitoring, Control, & Communications in One Integrated Package! Universal Recloser Control (URC) Reliable reclosing.
G GE Power Management DDS Integrated P&C System INTGRATED PROTECTION AND CONTROL SYSTEM DDS INTEGRATED PROTECTION INTEGRATED CONTROL.
1 GE Consumer & Industrial Multilin MultiLink Hardened Ethernet Communication Switches Ethernet Communication Solutions for the Industrial Automation,
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
W650 Wind Generator Protection System
Application & Configuration
EUT 1040 Lecture 10: Programmable Logic Controllers.
M Family Industrial Systems 1 M Family relays provide economical & reliable digital protection, metering, control and monitoring in an integrated package.
Applying Wireless in Legacy Systems
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 Chapter 1: Introduction to Switched Networks Routing and Switching.
Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900D L14 - Drive Programming with the New PowerFlex ® 520-Series AC Drives.
MIG II DIGITAL FEEDER PROTECTION
Providing Onboard and Onsite Ticketing Solutions to the Travel and Tourist Industry 1.
Make the most of your energy June 2008 Power Meter 800 PowerLogic ® Power Meter 8ECC.
International Scientific & Technical Conference
eAutomation Enabler – Advantech Industrial NETworking
AUT S.B.S. - Presentation name - Date - Language - Electronic File Name 1 SCHNEIDER ELECTRIC Solutions.
Join Us Now at: Enabling Interoperability for the Utility Enterprise And TESTING.
Smart Grid Research Consortium Conference Communications: Technologies Systems Future Trends Dr Rick Russell.
1 Industrial Systems A dvanced L ine P rotection S ystem.
Workflow Based Tools Simplifying All Job Functions.
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Confidential 1 MAP Value Proposition.
ZTE Series Automatic Transfer Switches (ATS)
Energetics with ELVAC.
G650 Generator Protection & Control System
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
April 2011 ezPAC SA320/330. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.
1 Sales Academy Training Inner Range Product Advantages, Competitors & The Future.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Make the most of your energy Make the most of your energy SM Add application photo in this area Need an easy to use, modular system for revenue metering?
Version 4.0. Objectives Describe how networks impact our daily lives. Describe the role of data networking in the human network. Identify the key components.
Line differential relay 7SD52
ACCESS CONTROL ExpansE - Distributed Access Control.
Web: tel: +44 (0) IEB Asset Maintenance System.
Need to enhance your network?
1 Monitor System Reliability alarm on demand, sag/surge, and etc. Perform Advanced Power Quality Analysis provide real-time trending. Centralized.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Sergey Khudyakov Data Transfer, Inc. Russia Large-scale RF mesh AMR implementation (experience in St.Petersburg)
1 Basic Star I Controller Sales Training Module 2 NexSentry Star I Controller What is the NexSentry Star I Controller? Multiple technology support Modular.
Workshop on Ethernet as fieldnetwork Presentation by:Werner Becherer SIEMENS Nürnberg Productmarketing A&D PT2 M Tel
New product introduction:
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 Chapter 1: Introduction to Switched Networks Routing And Switching 1.0.
1 Industrial Systems BUS2000 Busbar Differential Protection System Differential overcurrent system with percentage restraint protection.
Survey of Smart Grid concepts and demonstrations Smart substation Ari Nikander.
Copyright © 2010 Rockwell Automation, Inc. All rights reserved. Machine Condition Monitoring on ControlNet RSLogix5000 support for XM ®
By, Rakesh Das B.P.E-4 th yr. Roll No th August’ 2011.
COSEC ARC IP based Access Control Panel.
Peter Erning, PSP-T11, Power Gen 2010
Protection Philosophy
Water & Irrigation Control systems
PM9, PM9P and PM9C Power Meter
PowerLogic ION6200 Power and energy meter.
Presentation transcript:

Industrial Systems Introducing the L90 Universal Relay Advanced transmission line protection and control High-speed current differential protection for single or three-phase tripping applications

Industrial Systems L90: Line Differential Relay Monitoring & Metering URPC Software Communications Additional Features UR Advantages Applications Features and Benefits Protection and Control Block Diagram Summary How To Order

Industrial Systems Applications The L90 is suitable for diverse applications including: Transmission lines of any voltage level, including series compensated lines Stand-alone or component in automated substation control system Single-pole tripping and breaker-and-a-half installations

Industrial Systems UR Advantages The L90 is a member of the Universal Relay family FAMILY of relays built on a common platform Common “look & feel” for ease of use product to product All features, present and future, available to whole family Reduced training time and drafting costs MODULAR architecture Scaleable - accommodates a scaleable I/O architecture Flexible - accommodates different types of I/O Upgradeable - accommodates upgrading to new technologies COMMUNICATIONS High-speed networking capability (Ethernet - fiber, redundancy) Multiple Protocols - UCA 2.0, DNP 3.0, Modbus, IEC

Industrial Systems Features and Benefits Robust features put the L90 ahead of the competition: Innovative current differential scheme features adaptive restraint Programmable FlexLogic TM reduces device costs and simplifies wiring Non-volatile flash memory allows easy field upgrades Common draw out modules reduce spare part costs Charging current compensation for long lines or cable applications Channel asymmetry compensation (up to 10miliseconds) via Irig-B port (GPS) Scalable, flexible features that increase reliability

Industrial Systems Additional Features Cost-effective (up to 250 Microsecond) time synchronization for communications The L90 can synchronize and start protecting the line within 10 seconds A fine-tuned frequency tracking mechanism increases accuracy of the relay’s measuring and protection functions under off-normal frequency conditions User-programmable pushbuttons for secure and reliable custom control One of the best line current differential protection systems in the world

Industrial Systems Block Diagram Extensive range of device protection features

Industrial Systems Protection and Control Protection features include: Current differential protection, DTT (Direct Transfer Trip) Phase and ground distance Multiple current and voltage elements Directional phase and neutral FlexElement universal comparator Single-pole dual-breaker autoreclosure Control features include: Two Synchrocheck Elements Single-pole dual-breaker autoreclosure Comprehensive protection for all application specific functions and capabilities

Industrial Systems Monitoring and Metering Fault location and reporting – stored in non-volatile memory Breaker Arcing Current (I 2 t) – for maintenance on breaker wear User-programmable oscillography – data viewable via URPC software and can be stored in the oscillography record or data logger User-programmable data logger – captures events and time-stamps them for use with fault analysis Trip circuit monitoring Built in monitoring and metering open a window into your system

Industrial Systems URPC Software Settings Metering Configuration Single-Line Diagrams Oscillography Monitoring and control made easy

Industrial Systems Communications Modbus RTU over RS485 and over Ethernet TCP/IP DNP 3.0 Level 2 over RS485 and over Ethernet TCP/IP Peer-to-peer communications (GOOSE) via UCA/IEC61850 Direct I/O’s for Peer-to-Peer UR communications up to 100km on single-mode fiber Protocols: Open protocol facilitates communications with legacy devices

Industrial Systems Summary Integrated transmission line protection for series compensated lines Channel asymmetry, fast scheme syncronization, frequency tracking, and single-pole dual-breaker autorecloser Low overall installation costs saving the customer time and money Supports the open standard EPRI UCA TM MMS/Ethernet protocol Combines peer-to-peer high-speed communication capabilities with modularity, flexibility and field-programmable FlexLogix TM The L90 has the flexibility, connectivity and power to manage your system

Industrial Systems How to order To order the L90, contact your local GE Multilin sales office, or contact us directly: GE Multlilin Inc. 215 Anderson Ave., Markham, Ontario Canada L6E 1B3 Web: Tel: Fax: Order code available online or in the L90 product brochure:online